AR circuit breaker - Hydraulic magnetic,

Similar documents
FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

ER circuit breaker - Hydraulic magnetic,

FR circuit breaker - hydraulic magnetic,

CR circuit breaker - hydraulic magnetic,

RBR circuit breaker - Remote operated

PDR circuit breaker - Ground fault Datasheet

G-Series. Circuit Breaker.

N.S1-P relay - Signalling, post

AG 400 relay - Gold plated, 4 contacts

F-Series. Circuit Breaker

F-Series. Circuit Breaker

J-Series CIRCUIT BREAKER

PB-Series. GFCI/ELCI & Panel Seal

G-Series DIN-RAIL CIRCUIT BREAKER

Description The EA 112 socket has crimp contacts to allow rear connection on the socket.

PD-Series Ground Fault Circuit Protection

Renewable Energy. Circuit Breakers and Disconnects

L-Series. Circuit Breaker

CX-Series. Circuit Breaker

MS-Series. Circuit Breaker

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic Overcurrent Circuit Breaker

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

DD Frame - Series Circuit Breakers

AP/UP, AP/MIL Series Magnetic Circuit Protectors

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Electronic Circuit Breaker ESS20-0..

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

H-Series. Circuit Breaker.

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker

209 Series. Magnetic Circuit Protectors

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Products :: Circuit Protection :: Thermal Circuit Breakers

Thermal-Magnetic Circuit Breaker M1-...

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

209/219/229/249/279 Series Magnetic Circuit Protectors

Carling Circuit Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

QF(13) - Series Miniature Circuit Breakers

F-Series General Specifications

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

Thermal Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-..

Energy and traction control solutions

Series KTU7 UL489 Molded Case Circuit Breakers

QF(19) - Series Miniature Circuit Breakers

Thermal-Magnetic Circuit Breaker 201/-WA

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Electronic Circuit Breaker ESS20

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Catalog Issued 3-03 (PDF Rev )

Series KTU7 UL489 Molded Case Circuit Breakers

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

UMBW-UL489 and UL1077 Listed

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Table of Contents. HCC Contactor Nomenclature

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

TECHNICAL DESCRIPTION

Transfer switch OTEC open or delayed transition

OTEC Transfer switch open transition

Essential equipment for all your requirements

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Thermal Overcurrent Circuit Breaker 3130

Product Line Overview. The Most Logically Designed Contact Assembly

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Technical data for manual motor starters Type MS325

01 Spectra Plus - Introduction

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Model Number Structure

Circuit Breakers Series AM/S

Control Circuit Protection

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Electronic overload relays EF205 and EF370

High Performance Thermal-Magnetic Circuit Breakers 410/520/

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

L Frame - Series Moulded Case Circuit Breakers

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Transfer switch GTEC open or delayed transition

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Miniature Circuit Breakers

Thermal overload relays Type TA Class 10

Series L9 UL-489 Miniature Circuit Breakers

Transcription:

AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against unintended high currents. Optional with integrated auxiliary contacts to monitor the circuit. The trip point is always at maximum allowable current, independent of ambient temperature. Mid-trip handle to indicate clearly a breaker operation caused by electrical fault. With unique arc chute design which results in high interrupting capacities. Up to 6 poles which all break its electronic circuits when breaker trips, for optimal protection of the system. Wide range of currents and options available. Application To be used in every application where electrical systems, circuits or components must be protected against too high currents. This situation can occur, when under strained or heavy use a motor or other load-generating component within the equipment will draw additional current from the power source. High currents cause the wires or components to overheat and ultimately burn up. A circuit protection device should be employed at any point where a conductor size changes. Many electronic circuits and components like transformers have a lower overload withstand threshold level than conductors such as wires and cables. These components require circuit protection devices featuring very fast overload sensing and opening capabilities. The AR circuit breaker can be used in all Railway applications where protection against overload and short circuit is necessary, for example HVAC systems, (door) control systems, braking systems, passenger information systems, etc. DS-AR circuit breaker V2.7 Feb 207 Precise, temperature independent operation Panel mount Integrated auxiliary contacts (optional) Small design Up to 6 poles configuration High interrupting capacities due to unique arc chute method Mid-trip handle for electrical trip indication (optional) Immediate resetting possible Wide current range: 0. - 50 A Wide choice of time delays Maximum voltage 90 VDC / 277 VAC High contact pressure & longer contact life due to wiping self-cleaning contacts Flexibility by many options Benefits Proven reliable Long term availability Low life cycle cost No maintenance Railway compliancy All our circuit breakers are designed according: IEC 60077-/2/3/4 IEC 60947-2 NF F62-00 - /2/3 NF F6-/2 EN 45545-2 EN 5055 EN 6373 EN 5024- IEC 60068-2-30 IEC 60068-2-52 NF F6-0 MIL-STD-202G, method 6D MIL-STD-202G, method 7D, test condition A

Technical specifications Electrical characteristics Application voltage Rated voltage Min. operating voltage Max. operating voltage DC for -6 poles 2-72 VDC 8.4 VDC 90 VDC Remark: 8.4-80 VDC: max 50 A 80-90 VDC: max 40 A AC for -6 poles 2-25 VAC.8 VAC 277 VAC Current ratings Voltage coils Dielectric strength Insulation resistance Operating frequency 50/60 Hz, DC Max. interrupting cap. UL 77 Auxiliary switch 0. 50 A. Other ratings on request 6-65 VDC, 6-240 VAC. Other ratings on request 500 VAC, 60 Hz for minute between all electrically isolated terminals Minimum of 0 MΩ @ 500 VDC IEC 60934 7500 A @ 80 VDC, 0. - 50 A 3000 A @ 250 VAC, 0. - 50 A 5000 A @ 250 VAC, 0. - 50 A (with backup fuse) 5000 A @ 277 VAC, 0. - 30 A (with backup fuse) 3000 A @ 65 VDC, 0. - 50 A 5000 A @ 65 VDC, 0. - 50 A (with backup fuse) 500 A @ 80 VDC, 0. - 50 A 3000 A @ 80 VDC, 0. - 50 A (with backup fuse) 3000 A @ 250 VAC, 0. - 50 A 5000 A @ 250 VAC, 0. - 30 A (with backup fuse) Integrated, load side. SPST. Auxiliary switch senses the on-off position of circuit breaker handle, as well as the open-closed position of breaker contact. AC min. switching cap. Silver auxiliary contacts 5-20 VAC: 0 ma > 20 VAC: ma Gold auxiliary contacts 5 ma / 5 VAC AC max. switching cap. 5 A / 25 VAC 0 ma / 25 VAC DC min switching cap. DC max. switching cap. < 20 VDC: 0 ma > 20 VDC: ma 3 A / 32 VDC 0 ma / 25 VDC (max. 2000 cycles) All loads mentioned are resistive loads. 5 ma / 5 VDC 0 ma / 32 VDC 2 ma / VDC (max. 2000 cycles) 2 DS-AR circuit breaker V2.7 Feb 207

Technical specifications General characteristics Number of poles, 2, 3, 4, 5 or 6 poles For DC and AC applications: -2 poles 50 A 3-6 poles 30 A Terminals Auxiliary contacts Mounting Body Actuator handle Int. circuit configuration Weight (average, depending on configuration) Width per pole Mechanical characteristics Stud / screw / double faston, see circuit & terminal diagrams Faston or solder type, see circuit & terminal diagrams The hydraulic-magnetic circuit breakers of Mors Smitt can be mounted in any position. A hydraulic-magnetic breaker is designed to must hold at 0% of the breaker s current rating and is calibrated to must trip at 25% of the breaker s current rating. If the mounting position is +90 degrees from a vertical panel mount (handle facing down, ceiling mount position) the trip and must hold rating is reduced by %. In ceiling mount position % should be added to the rated current. In table mount position (handle facing up) the same rated current can be used as in wall mount position. Blue colour Several colours with I O and On-off legends Series trip, shunt trip & switch only 65 g per pole 9.2 mm Material Half shell - BMC 605 Handle - Valox 420SEO UL94V0 Terminals - Brass with acid tin plate Endurance Trip free mechanism Trip indication: Standard (no mid-trip) Mid-trip Mid-trip with alarm switch.000 ON-OFF operations @ 6 per minute with rated current & voltage. Trips on short-circuit or on overload, even when the actuator is forcibly held in the ON position. When manually moving the operating handle from OFF to ON position, an auxiliary switch is actuated. When an overload or a short circuit causes the circuit breaker to trip, the operating handle moves positively to the OFF position and the auxiliary switch is actuated. When manually moving the operating handle from OFF to ON position, an auxiliary switch is actuated. When an overload or a short circuit causes the circuit breaker to trip, the operating handle moves positively to the mid position and the auxiliary switch is actuated. When manually moving the operating handle from OFF to ON position, an auxiliary switch is not actuated. When an overload or a short circuit causes the circuit breaker to trip, the operating handle moves positively to the mid position and the auxiliary switch is actuated. In this case the auxiliary switch is only actuated by an electrical trip, not by manually operating the handle. Remark: It is possible to manually switch the circuit breaker to the mid-trip position when the handle is switched from OFF to ON position quickly and with strong upwards force. Normally this won t occur in standard use. This is a normal phenomenon related to the design of the product. DS-AR circuit breaker V2.7 Feb 207 3

Technical specifications Environmental characteristics Environmental Complies to EN 5025- and IEC 60077- Operating temperature -50 C...+85 C Vibration Shock Thermal shock IEC 6373, Category, class B body mounted IEC 6373, Category, class A & B body mounted Complies to MIL-STD 202 G method 7D, test condition A Salt mist Complies to IEC 60068-2-52 severity level 3 Damp heat Complies to IEC 60068-2-30 test method Db variant Fire & smoke Complies to NFF 6, NFF 62 Protection Moisture resistance / humidity IEC 60529, IP40 when a panel is mounted over the circuit breaker Complies to MIL-STD 202G method 6D Resistance, impedance Resistance, impedance values from Line to Load terminals (Values based on series trip circuit breaker) 00 0 Current (amps) Tolerance (%) 0. - 5.0 5.- 20.0 + 5% + 25 % 20. - 50.0 + 35 % Ohms 0. 0.0 0.00 0.0 0. 0 Ampere rating 4 DS-AR circuit breaker V2.7 Feb 207

Technical specifications Inrush pulse tolerance Table of time delay values DELAY 0% 25% 35% 50% 200% 400% 600% 800% 00% 200% No Trip May Trip ---.032 MAX.024 MAX.020 MAX.08 MAX.06 MAX.05 MAX.03 MAX No Trip.03 -.25 ---.0 -.070.008 -.032.006 -.020.005 -.020.004 -.020.004 -.020.004 -.020 2 No Trip.500-6.50 ---.300-3.00.30 -.20.03 -.220.0 -.20.004 -.090.004 -.060.004 -.040 4 No Trip 2.00-60.0 ---.20-40.0.600-20.0.50-3.00.030 -.30.004 -.600.004 -.0.004 -.0 6 No Trip 45.0-345 --- 20.0-50 9.00-60.0.40 -.4.50-5.80.009-3.70.005 -.70.005 -.500 20 No Trip May Trip ---.040 MAX.035 MAX.030 MAX.025 MAX.020 MAX.07 MAX.05 MAX 2 No Trip.04 -.50 ---.0 -.095.008 -.055.006 -.035.005 -.027.005 -.02.004 -.08.004 -.07 TRIP 22 No Trip.700-2.0 ---.350-4.00.30 -.30.027 -.220.008 -.30.004 -.090.004 -.045.004 -.040 TIME 24 No Trip.0-60 --- 6.00-60.0 2.20-20.0.300-3.00.050 -.30.007 -.500.005 -.060.005 -.040 (SECONDS) 26 No Trip 50.0-700 --- 32.0-350.0-90.0.50-5.0.500-7.00.020-3.00.006-2.00.005 -.00 42 No Trip.700-2.0 ---.400-6.00.80-2.30.050 -.600.026 -.300.08 -.200.04 -.50.02 -.30 44 No Trip 7.00-0 --- 3.00-50.0. - 8.0.220-3.00.20 -.70.075 -.20.050 -.850.042 -.720 46 No Trip 50.0-700 --- 3.0-350 2.0-50.50-20.0.700 -.0.404-7.90.260-6.50.98-5.80 52 No Trip.500-6.50 ---.340-4.50.80-2.30.05 -.600.030 -.320.08 -.220.04 -.200.02 -.30 54 No Trip.50-50.0 ---.750-35.0.350-8.0. - 3.00.070 -.70.045 -.40.039 -.30.035 -.30 56 No Trip 45.0-345 --- 9.0-70 8.50-0.24-5.0.4-9.00.256-8.00.2-5.50.98-2.90 Notes: Delay curves, 2, 4, 6, 2, 22, 24, 26, 42, 44, 46, 52, 54, 56: Breakers to hold 0% and must trip at 25% of rated current and greater within the time limit shown in this curve. Delay curves, 20: Breakers to hold 0% and must trip at 50% of rated current and greater within the time limit shown in this curve. All curves: Curve data shown represents breaker response at ambient temperature of 25 C (77 F) with no preloading. Breakers are mounted in standard wall-mount position. Delay times may vary at different temperature, the trip current rating remains unchanged. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 2 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz /2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads. DS-AR circuit breaker V2.7 Feb 207 5

Time delay values AC Instantaneous Medium 000 00 50/60 Hz INSTANTANEOUS CURVE NO. 20 000 00 50/60 Hz MEDIUM DELAY CURVE NO. 24 0. 0..0.0.00 0 200 300 400 500 600 700 800 900 25 50 00 0 200.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 Ultrashort Long 000 00 50/60 Hz ULTRASHORT DELAY CURVE NO. 2 000 00 50/60 Hz LONG DELAY CURVE NO. 26 0. 0..0.0.00 0 200 25 50 300 400 500 600 700 800 900 00 0 200.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 Short 000 00 50/60 Hz SHORT DELAY CURVE NO. 22 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 6 DS-AR circuit breaker V2.7 Feb 207

Time delay values High Inrush AC Short 000 00 50/60 Hz - HI-INRUSH SHORT DELAY CURVE NO. 42 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 Medium 000 00 50/60 Hz - HI-INRUSH MEDIUM DELAY CURVE NO. 44 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 Long 000 00 50/60 Hz - HI-INRUSH LONG DELAY CURVE NO. 46 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 DS-AR circuit breaker V2.7 Feb 207 7

Time delay values DC Instantaneous Medium 000 00 D.C. INSTANTANEOUS CURVE NO. 000 00 D.C. MEDIUM DEL AY CURVE NO. 4 0..0 T R IP TIME INSECONDS 0..0.00 0 200 300 400 500 600 700 800 900 00 50 0 200.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 Ultrashort Long 000 00 D.C. ULTRASHORT DELAY CURVE NO. 000 00 D.C. LONG DELAY CURVE NO. 6 0. 0..0.0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50.00 0 200 300 25 50 400 500 600 700 800 900 00 0 200 Short 000 00 D.C. SHORT DELAY CURVE NO. 2 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 8 DS-AR circuit breaker V2.7 Feb 207

Time delay values High Inrush DC Short 000 00 D.C. - HI - INRUSH SHORT DELAY CURVE NO. 52 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 Medium 000 00 D.C. - HI - INRUSH MEDIUM DELAY CURVE NO. 54 0..0.00 0 200 300 25 50 400 500 600 700 800 900 00 0 200 Long 000 00 D.C. - HI - INRUSH LONG DELAY CURVE NO. 56 0..0.00 0 200 300 400 500 600 700 800 900 00 0 200 25 50 DS-AR circuit breaker V2.7 Feb 207 9

Circuits & terminal diagrams A B A B DS-AR circuit breaker V2.7 Feb 207

Form & fit drawings Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.020 [0.5] unless otherwise specified DS-AR circuit breaker V2.7 Feb 207

Form & fit drawings Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.020 [0.5] unless otherwise specified 2 DS-AR circuit breaker V2.7 Feb 207

Form & fit drawings Terminal barriers 2X.64[4.66] 2.60[54.86].235[5.97] 2X.64[4.66].83[20.64] 2.60[54.86] 2X.375[9.53].500[2.70].235[5.97] 3X.76[4.47].609[5.48] Mounted cover auxiliary switch 2.00[5.08].83[20.64].500[2.70] 2X.375[9.53] 2X.266[6.75] 2X.4[2.90] 3X.76[4.47].00[25.40].609[5.48] 3X.272[6.9].64[4.66] 2.00[5.08] 2.6[54.86].00[25.40] 2X.4[2.90] 2X.266[6.75] 3X.272[6.9].64[4.66] 2.6[54.86] Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.020 [0.5] unless otherwise specified DS-AR circuit breaker V2.7 Feb 207 3

Ordering scheme AR - 6-24 - B - A - 3-3 - 3 2. Series 2. Poles 3. Current rating 4. Frequency 5. Circuit 6. Actuator 7. Actuator 8. Auxiliary 9. Terminal. Mounting. Agency & delay colour switch & barriers approval & legend Series AR 2 Poles One 4 Four 2 Two 5 Five 3 Three 6 Six 3 Current rating (amperes) 2 0.0 25 0.50 220 0.200 225 0.250 230 0.300 235 0.500 240 0.400 245 0.450 250 0.500 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 4.000 52.250 45.500 57.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 Or voltage coil (nominal rated voltage) 2 A06 6 DC J06 6 AC A2 2 DC J2 2 AC A8 8 DC J8 8 AC A24 24 DC J24 24 AC A32 32 DC J48 48 AC A48 48 DC J65 65 AC A65 65 DC K20 20 AC L40 240 AC Other values on request 485 8.500 490 9.000 495 9.500 6.000 65 5.000 66 6.000 67 7.000 68 8.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 4 Frequency & delay 03 DC, 50/60 Hz, switch only DC instantaneous DC ultra short 2 DC short 4 DC medium 6 DC long 20 50/60 Hz instantaneous 2 50/60 Hz ultra short 22 50/60 Hz short 24 50/60 Hz medium 26 50/60 Hz long 42 3 50/60 Hz short, hi-inrush 44 3 50/60 Hz medium, hi-inrush 46 3 50/60 Hz long, hi-inrush 52 3 DC, short, hi-inrush 54 3 DC, medium, hi-inrush 56 3 DC, long, hi-inrush 5 Circuit A 4 Switch only (no coil) B Series trip (current) C Series trip (voltage) D 5 Shunt trip (current) E 5 Shunt trip (voltage) H 5,6 Dual coil with shunt trip voltage coil 6 Actuator 7 A B S T Handle, one per pole Handle, one per multipole unit Mid-trip handle, one per pole Mid-trip handle, one per pole & alarm switch 7 Actuator colour & legend Actuator colour I-O ON-OFF Dual Legend colour White A B Black Black C D 2 White Red F G 3 White Green H J 4 White Blue K L 5 White Yellow M N 6 Black Grey P Q 7 Black Orange R S 8 Black White V W 0 Black (short handle) 8 4 DS-AR circuit breaker V2.7 Feb 207

Ordering scheme 8 Auxiliary switch 9 0 Without auxiliary switch 2 SPDT, 0. QC term. 3 SPDT, 0.39 solder lug 4 SPDT, 0. QC term. (gold contacts) A SPDT, 0. QC term. with mounted cover B SPDT, 0. QC term. (gold contacts) with mounted cover Mounting & barriers Mounting style Barriers threaded insert, 2 per pole 6-32 x 0.95 inch No A 6-32 x 0.95 inch Yes (between poles only) 2 ISO M3 x 5 mm No B ISO M3 x 5 mm Yes (between poles only) 9 Terminal Push on, 0.250 tab (Q.C.) 2 Screw 8-32 with upturned lugs 3 2 Screw 8-32 (bus type) 4 Screw-32 with upturned lugs 5 2 Screw -32 (bus type) 6 Screw 8-32 with upturned lugs and 30 o bend 7 2 Screw 8-32 (bus type) and 30 o bend 8 Screw -32 with upturned lugs and 30 o bend 9 2 Screw 8-32 (bus type) and 30 o bend B Screw M5 with upturned lugs C Screw M4 with upturned lugs E 2 Screw M4 (bus type) F Screw M5 with upturned lugs and 30 o bend G 2 Screw M5 (bus type) and 30 o bend H 2 Screw M5 (bus type) M 2 M6 threaded stud Q Push-in stud R Screw M4 with upturned lugs and 30 o bend T Screw M4 (bus type) and 30 o bend U Double faston 0.25 / 6.3 mm V M6 threaded stud 7 mm long with NFF washers and nut 2 Agency approval 2 3 TUV certified, UL recognized Notes:. Available up to two poles with AC or DC delays 2. Separate pole type voltage coils not rated for continuous duty. Available only with delay codes, 20 & 30 3. Available with circuit codes B & D only 4. For 0. - 30 A: select current code 630 For 35-50 A: select current code 650 5. Available with terminal codes, 2 & 3.Current rating limited to 30 A maximum 6. Consult Mors Smitt for available dual coil options, as special catalogue number is required. With shunt construction, dual coils will trip instantaneously on line voltage. Dual coils require 30 VA minimum power to trip and are rated for intermittent duty only 7. Actuator code: S: Handle moves to mid-position only upon electrical trip of the breaker, available with all circuit codes, except switch only T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker, available with circuit codes B & C 8. Single pole only 9. On muli-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole (rear view). Screw terminals are recommended on ratings higher than 20 A Ratings over 30 A are only available with terminals codes 5, 9, G and H. Terminal code ; up to 30 A, but not recommended over 20 A 2. Terminal codes 3, 5, 7, 9, E, G and H (bus type) are supplied with lock washers Terminals code M (M6 threaded stud) is supplied with lock and flat washers 3. TUV certified: not for switch only circuit and only for actuator legend I-O and dual legend UL recognized: for most applications, not all Special applications without approvals: agency approval code A DS-AR circuit breaker V2.7 Feb 207 5

DS-AR circuit breakers-v2.7 Feb 207 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 938 Rosny-sous-Bois Cedex, FRANCE T +33 (0) 482 440, F +33 (0) 4855 900 E sales.msf@wabtec.com Mors Smitt Asia Ltd. 29/F., Fun Towers, 35 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E sales.msa@wabtec.com Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +3 (0)30 288 3 E sales.msbv@wabtec.com Mors Smitt Technologies Inc. Johnson Drive, Buffalo Grove, IL 60089-698, USA T + 847 777 6497, F + 847 520 2222 E salesmst@wabtec.com Mors Smitt UK Ltd. Graycar Business Park, Barton under Needwood, Burton on Trent, Staffordshire, DE3 8EN, UK T +44 (0)283 722650 F +44 (0)283 72265 E sales.msuk@wabtec.com RMS Mors Smitt 6 Anzed Court, Mulgrave, VIC 370, AUSTRALIA T +6 (0)3 8544 200 F +6 (0)3 8544 20 E sales.rms@wabtec.com (c) Copyright 207 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. Mors Smitt does not warrant that any of the information contained herein is complete, accurate, free from potential errors, or fit for any particular purpose. Mors Smitt does not accept any responsibility arising from any party s use of the information in this document.