FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

Similar documents
FL B. Halogen light generator for Fibre optic lighting systems

FL 150 XT-2 B, F, and C

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

FL 1000 XT C DMX. User manual

RobLight FL User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

Ara 4. Mounting and installation instructions. Item no.: Ara K black. User manual

FL Roblon Lighting. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn

Light Source User Guide

Light Source User Guide

USER MANUAL LUX-LD30W LED MOVING HEAD

HyperFlex 12G.

LED Twister II. User manual UK Version 1.0

User Guide for Logo Projector

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

USER MANUAL PAR56 LED PAR CANS

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Navigator ORDERCODE 40410

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED Pinspot 2. Snapshot. User Manual

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

CH-158 Color Bank 8 USER MANUAL

LyteLaunch Dry - Wet and DMX Models. Operation Manual

LED Pinspot 2. Snapshot. User Manual

Mania EF1 user manual

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (24V)

Mini Aquatic ORDERCODE 30844

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Measurements are expressed in millimeters.

Mass Sine 24/10000 Mass Sine 24/15000

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

STATIC DAYLIGHT PAR 575 VF

GC SERIES HORTICULTURAL LIGHTING SYSTEM

GC SERIES HORTICULTURAL LIGHTING SYSTEM

Installation Instructions

Snapshot. Hurricane 1300 USER MANUAL F-1300

P/N Wheeler. user manual

FiberSource Q150. user manual P/N

Installation Instructions

Stereo Microscopes Instruction Manual

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

Fiber Optic Illuminator. Model 21AC Model 21DC

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Maintenance Adjustments

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

Preface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT

Indoor high bay. Industrial and Commercial High Bays

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Snapshot. SkyScan 4000 USER MANUAL

INSTALLATION TEMPLATE

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Owner s Manual Currency Counter

AvaLight-DHS Deuterium Halogen Light Source Operating manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

CX-SERIES ADVANCED BATTERY CHARGER

Installation Instructions

User s Manual Power Supply IM E. 5th Edition

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

LARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions

USER S MANUAL TUBE SEALER. Model SE450. No. CAT.SE45010Ce

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

Installation Instructions

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

HLS Watt Halogen Illuminator Service Manual

CI 3000 Coil Inserter

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Microscope light manual

ECO Spot 2500 User Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

ECO Spot 2500 User Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

TOYOTA AVALON INTERIOR LIGHT UPGRADE Section TOYOTA II - Installation AVALON Procedures

OWNER S MANUAL POWER INVERTER

Register your instrument! HeatSealer S100. Operating manual

MOVING HEAD. User manual CAUTION!

3. Operating instructions: Minor 200

MAINTENANCE SPECIFICATIONS LEGISLATION WARRANTY

Floodlights. XL-LED Performance IP66 Mini Floodlights 58 LED Weatherproof Floodlights 60

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Manual Calibrator PCE-IC1

GENUINE PARTS INSTALLATION INSTRUCTIONS

Operation Manual. 355 Lighting System. Safety 2. Features 4. Component Overview 5. Controls & Indicators 6. Operation 7.

MEDICAL LIGHTING. LED-lighting. green efficiency

Gavita HortiStar 1000 DE EU/US

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

Two Stage Rotary Vane Vacuum Pumps Operation and Maintenance Manual

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

Bubble King. User Manual

1.2.5 kw POSITION POSITION

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

Transcription:

FL 20-2 Halogen light generator for use with fibre optic lighting User Manual Mounting and installation instruction. Item no.: 0120 0001 FL 20-2 Ø9 230V +99082106 rev. 25.09.2106

1. Introduction This manual serves you as a guideline to how the system is operated in the safest way. Following the recommendations in this guideline all contributes to: Enhanced functionality Extended lifetime of components Uninterrupted illumination Your Roblon halogen light generator, type FL 2001 is intended for indoor use in fibre optic lighting systems using either glass or PMMA fibres. This light generator is prepared for use in cabinets or showcases, either closed or semi closed compartments. Contents 1. Introduction... 1 2. Product overview and packing list... 3 3. Technical info... 3 4. Installing the light generator... 4 5. Fixating the light generator to the surface... 4 6. Trouble shooting... 7 7. Spare parts and accessories... 7

2. Product overview and packing list Contents of the box: - FL 20-2 - User manual 3. Technical info Light port size: Ø9 mm. Fibre type: PMMA/Glass Supply voltage: 230 V / 50-60 Hz Lamps: 20W Philips type 13861, 12V Halogen. Power consumption: 23 VA Fuse: Integrated auto Power cord: Supply cord w/2 conductors. Ballast: Electronic Thermal protection: Auto reset. Cooling system: Natural convection Ambient temperature: -15 - +40 C Lamp type: Halogen Lamp life time: 4,000 hours Lamp colour temp: 3,000K Operating environment: Indoor/dry locations Protection rating: IP 20 Material: Steel Powder coated. Dimensions: (L x H x W) 172 x 90 x 91 mm. Weight: 1.2 kg. Safety approvals: CE, F, EMC

4. Installing the light generator 1. Insert the harness' common end fully into the light port on the light generator. 2. Tighten the finger screw at the light port. 3. Check that the requirements of installation and ventilation are met. 4. Connect the supply cord to the main power supply. Fibre types FL 20-2 can be used with both plastic (PMMA) and glass fibre. 5. Fixating the light generator to a surface 1. Loosen the screw at the one side of the light generator to open the cover. 2. Be careful not to damage the lamp. Remove it if necessary. 3. Mount the light generator with one or two screws (not included) through two holes in bottom of the light generator. 4. Reinstall the lamp and close the cover again.

Maintenance The outside of the cabinet may be cleaned with a damp cloth. If the environment is very dusty, it is recommended that the interior be inspected and cleaned every 3 month or with suitable intervals. If it is necessary to clean the lamp and reflector, do so using a lint-free cloth. Do not touch the cleaned surfaces with the fingers as this will reduce the performance on lamp life. The best results may be ensured by fitting a new lamp under such conditions.!!! Never apply detergents containing alcohol to PMMA fibres!!! Changing a lamp: 1. Switch of disconnect unit from power. 2. Open the top cover 3. Lift the lamp out of the lamp holder 4. Disconnect the lamp 5. Fit a new lamp (type Philips no 13861). Take care not to touch the lamp or reflecting surfaces with bare fingers. Should this accidentally happen, remove the lamp & clean as previously described. 6. Close the cover.

6. Trouble shooting Symptom Cause Solution No light Light switches ON and OFF The light output has diminished Is the power ON? Is the power cord properly connected? Is the light generator too hot? Is the lamp blown? Is the light generator too hot while operating? Is the fan blocked? Is the lamp old? Is the fibre harness common end dirty? Turn ON the power. Reinsert the power cord. Check with the installation instructions. Cool off for 10 minutes and try again. Replace lamp with new one. Check with installation instructions. Clear the airways. Secure airflow is not blocked. Replace the lamp with a new one. Clean the harness common end with a damp cloth. Finish by wiping off with a dry lint-free cloth. 7. Spare parts and Accessories Description Roblon item no.: Model designation Image Lamp +65124200 13861 from Philips 12V Halogen Trafo +68002121 +68001212 230V / 12V 60W, electronic 120V / 12V 60W, electronic

Roblon accepts no responsibility for possible errors in printed and electronic material. Roblon reserves the right to alter or discontinue products without notice. 2012, Roblon A/S Roblon Lighting Tel: +45 9620 3366 Nordhavnsvej 1 Fax: +45 9620 3396 9900 Frederikshavn info@roblon.com Denmark www.roblon.com