Catalogue. FlowBar. High Capacity Slot Diffuser.

Similar documents
FlowBar High Capacity Slot Diffuser

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

Linear Floor Grilles Models FG, F20, F25 and FRO

Cell Ventilation Security Grille

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Perforated Face Ceiling Diffusers

Floor Swirls Models BZD and SZD

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Fire Block and Pressed Steel Grilles

LINEAR SLOT DIFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

LINEAR SLOT DUFFUSERS

SERIES GSL. Linear Slot Diffuser

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

SERIES HSL. High Capacity Linear

Wall and Ceiling Grille

Fire Block and Pressed Steel Grilles

fsfdfsdfsdfssfsf OMNI DIFFUSER

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

SERIES GB. Adjustable Slot Swirl Diffusers

IrisControlDamper. For Adjustment and Measuring of Airflow.

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

SERIES GZL. High Induction Linear Diffuser (Patented)

Blade Features. AirShield Control and Shut Off Dampers. AirShield

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

SDV Vane Swirl Diffusers

Ceiling swirl diffusers

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

LINEAR BAR GRILLES. GRILLES-Linear Bar

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

LINEAR SLOT DIFFUSERS PLENUMS

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

SERIES MBD. Multi-Blade Linear Diffuser

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

TBV - Terminal Unit. Halton TBV. Terminal Unit

SERIES PG. Perforated Face

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Aircell Polymer Range

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

Airline Linear Grilles

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Ceiling swirl diffusers with perforated face plate

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

Ceiling swirl diffusers with perforated face plate

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Type VSD35. Nominal length up to 1500 mm: one spigot

Series HCD Airfoil Control Damper

KLIMA Active Chilled Beams

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Slot diffusers for ceiling installation

SERIES GSF. Fixed Swirl Diffusers (Patented)

MODULAR CORE CEILING DIFFUSERS

Ceiling swirl diffusers

Total comfort control

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

C O L M A N. Air Distribution NOZZLE DIFFUSERS N SERIES SERIES

FIXED BLADE LOUVRE FACED CEILING DIFFUSER

CONTROL SMOKE AND BALANCING DAMPERS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

LINEAR DIFFUSERS AND BAR GRILLES

Air Handling Reference Catalogue

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

Slot diffusers, Round duct diffusers. IMP Klima

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

SERIES GD. Square and Circular Fixed Swirl Diffusers

ACTIVENT System. Specifications. Product code example ACTA

RPD ROUND PLAQUE DIFFUSER

series KFD-KLD Linear slot diffusers

Transcription:

Catalogue FlowBar High Capacity Slot Diffuser www.air-diffusion.co.uk sales@air-diffusion.co.uk

Content Introduction... 4 Diffuser Specification... 5 Air Patterns... 6 Flange Styles... 7 Curved Sections... 8 Corner Sections... 9 Performance Data... 10-25 Standard Fixing Details...26 Dimensions - Diffuser... 27-29 Installation Details...30-32 Ordering Information - Diffusers...33 Plenum Boxes...34-36 Accessories...37-38 Order Information - Plenum Boxes...39 2 Air Diffusion FlowBar

Swegon R&D Academy The Test Centre at Whitstable provides state of the art facilities for testing a complete range of products. It was designed in accordance with BSRIA recommendations and benefits from third party annual assessment. It has a well equipped demonstration area where tests can be witnessed by contractors, consultants and end clients. Third party witnessing by BSRIA is available if required. The test facility is fitted with the latest equipment and exceeds the requirements of BS EN 12238:2001 (for air terminal devices aerodynamic testing and rating for mixed flow applications) with a test room size of 7.5m long x 5.6m wide x 2.8m high. Ceiling heights and floor voids can also be adjustable depending on the test regime required. A purpose designed air handling system is able to supply conditioned air across a wide temperature range in both heating and cooling modes with volumes up to the equivalent of 20 air changes per hour being available. Sophisticated measuring and logging equipment is able to monitor air volumes, velocities, pressures and temperatures as well as airflow pattern visualisation via the use of smoke generation within the test laboratory. For bespoke testing please get in touch with us. www.air-diffusion.co.uk 3

Introduction FlowBar is an architecturally designed high capacity linear slot diffuser. It is designed to combine a high air handling capacity with maximum flexibility and is suitable for either ceiling or sidewall applications. The flexibility of the system can blend into a design or provide contrast with its striking but simple design. FlowBar is a flexible system that can provide straight lines or curves to blend with other architectural elements and enhance the overall concept of the project. Ceiling Mounted High Throw Key Features High capacity single slot diffuser available in five slot widths of 25mm, 38mm, 51mm, 63mm and 76mm Surface mounted and plaster frame border frames available Choice of HT (High Throw) series horizontal or JT (Jet Throw) series vertical air patterns Curved Sections Ceiling or Sidewall Applications Modular or Continuous s Mitred Corner Pieces Angled End Sections Adjustable Discharge Pattern Concealed Fixing Matching Plenum Boxes Wall Mounted Jet Throw 4 Air Diffusion FlowBar

Specification High Throw (HT) Series FL-10-HT 25mm Slot FL-15-HT 38mm Slot FL-20-HT 51mm Slot FL-25-HT 63mm Slot FL-30-HT 76mm Slot The High Throw series is primarily designed for ceiling applications and allows the air diffuser to become inconspicuous, whilst fully integrating into the ceiling system. The FlowBar systems satisfy both architectural and engineering requirements for designing an air distribution system that will maintain optimum room air conditions whilst being efficient yet inconspicuous. Integral pattern controllers are 600mm in length allowing the airstream to be directed left and right for horizontal and vertical airflow. Standard slot sizes are 25mm, 38mm, 51mm, 63mm and 76mm with single section lengths available up to 2400mm. Frame styles 66 (surface mounted), 22 and 55 (plaster frame border) and 11 flangeless are available as standard. Factory engineered plenum boxes are supplied to ensure a trouble free installation and to ensure published performance data is met. Specification Jet Throw (JT) Series FL-10-JT 25mm Slot FL-15-JT 38mm Slot FL-20-JT 51mm Slot FL-25-JT 63mm Slot FL-30-JT 76mm Slot The Jet Throw series has pattern flow controllers to allow the airstream to be jetted in a horizontal direction (sidewall mounted) whilst fully integrating into the wall system. The FlowBar systems satisfy both architectural and engineering requirements for designing an air distribution system that will maintain optimum room air conditions whilst being an integral component of the architectural concept of the project. Integral pattern controllers 600mm in length allow the airstream to be directed vertically left and right (ceiling application) and up and down (sidewall application) at a 45 angle. Jet Throw pattern controllers allow extended throws in typical high bay applications for heated and/or cooled air. Jet Throw pattern controllers are useful along perimeter walls where heated air can be directed downward. Standard slot sizes are 25mm, 38mm, 51mm, 63mm and 76mm with single section lengths available up to 2400mm. Frame styles 66 (surface mounted), 22 and 55 (plaster frames) and 11 flangeless are available as standard. Factory engineered plenum boxes are supplied to ensure a trouble free installation and to ensure published performance data is met. www.air-diffusion.co.uk 5

Air Patterns High Throw (H T) Ceiling Mounted Horizontal Left Horizontal Right Vertical Jet Throw (JT) Sidewall Mounted Horizontal Upward Downward 6 Air Diffusion FlowBar

Flange Styles Standard Types 11, 22, 55 & 66 Type 11 Flangeless Type 22 Shallow Plaster Frame Type 55 Deep Plaster Frame Type 66 Surface Mounting www.air-diffusion.co.uk 7

Curved Sections Curved Supply Key B = Overall Width T = Overall C = Overall Arc L = Slot Width Minimum Curve Radius HT High Throw - Border 11 Slot Width Min Radius (mm) FL10 25 800 FL15 38 1200 FL20 51 2100 HT High Throw - Border 22 Slot Width Min Radius (mm) FL10 25 1700 FL15 38 1700 FL20 51 45000 HT High Throw - Border 66 Slot Width Min Radius (mm) FL10 25 800 FL15 38 1200 FL20 51 2100 Curving is only possible with the HT model using border types 11/22/66. Please contact our technical team to discuss curved FlowBar in more detail including any special applications not covered in this catalogue. 8 Air Diffusion FlowBar

Corner Sections 90 Mitred Corner Multidirection Supply * Specify Angle 90 Mitred Corner Multidirection Supply Slot/Style Width T B Border 66 25 200 95 Border 22 25 200 107 Border 55 25 200 70 Border 11 25 200 70 Border 66 38 200 121 Border 22 38 200 133 Border 55 38 200 95 Border 11 38 200 95 Border 66 51 200 146 Border 22 51 200 158 Border 55 51 200 121 Border 11 51 200 121 Border 66 63 300 172 Border 22 63 300 172 Border 55 63 300 146 Border 11 63 300 146 Border 66 76 300 197 Border 22 76 300 197 Border 55 76 300 172 Border 11 76 300 172 Slot/Style Width T B Border 66 25 200 95 Border 22 25 200 107 Border 55 25 200 70 Border 11 25 200 70 Border 66 38 200 121 Border 22 38 200 133 Border 55 38 200 95 Border 11 38 200 95 Border 66 51 200 146 Border 22 51 200 158 Border 55 51 200 121 Border 11 51 200 121 Border 66 63 300 172 Border 22 63 300 172 Border 55 63 300 146 Border 11 63 300 146 Border 66 76 300 197 Border 22 76 300 197 Border 55 76 300 172 Border 11 76 300 172 www.air-diffusion.co.uk 9

Performance Data - High Throw (HT) Continuous Slot Plenum High Throw (HT) Data based on active section 1200 long FL-10 Air Flow, l/s-m 36 58 79 101 122 144 165 25mm Slot Width Static Pressure, Pa 7 18 34 55 81 112 148 NC (Noise Criteria) <10 16 26 33 39 44 49 Throw, m 1.5-2.5-4.3 2.8-4 - 5.5 3.8-4.5-6.5 4.3-5.3-7.3 4.5-5.8-8.3 5.3-6 - 8.8 5.5-6.8-9.5 FL-15 Air Flow, l/s-m 43 65 86 108 129 151 173 38mm Slot Width Static Pressure, Pa 8 18 32 51 73 99 129 NC (Noise Criteria) <10 14 24 31 37 42 48 Throw, m 1.8-3 - 5 3-4.3-5.8 4-5 - 6.8 4.3-5.5-7.5 5-5.8-8.3 5.3-6.5-8.8 5.5-6.8-9.8 FL-20 Air Flow, l/s-m 43 72 101 129 158 187 216 51mm Slot Width Static Pressure, Pa 5 14 28 46 68 95 127 NC (Noise Criteria) <10 11 22 30 36 41 46 Throw, m 1.5-2.8-5 2.8-4.3-6 4-5.3-7.3 5-5.8-8.3 5.3-6.5-9.3 5.8-7 - 10 6-7.5-10.8 FL-25 Air Flow, l/s-m 43 79 115 151 187 223 259 63mm Slot Width Static Pressure, Pa 3 10 22 38 58 82 110 NC (Noise Criteria) <10 11 23 31 38 43 48 Throw, m 1.3-2.5-5 3-4.5-6.5 4.3-5.5-8 5.3-6.5-8.8 5.8-7 - 10 6.5-7.5-11 6.8-8.3-12.8 FL-30 Air Flow, l/s-m 43 86 129 173 216 259 302 76mm Slot Width Static Pressure, Pa 3 11 25 44 69 99 135 NC (Noise Criteria) <10 <10 18 27 34 40 45 Throw, m 1-2.3-4.5 3-4.5-6.8 4.5-5.8-8.3 5.5-6.8-9.8 6-7.5-10.8 6.8-8.3-12 7.3-8.8-12.8 Table A. NC Correction for, mm 600 1200 1800 2400 3000 Supply -3 0 +2 +3 +5 Return 0 +3 +5 +6 +8 Table B. Correction Multiplier for, mm 600 1200 2400 3000 3600 Throw Correction 0.72 1 1.5 1.7 1.8 10 Pressures are given in Pascal (Pa) Pressure loss data assumes a duct velocity is less than 4m/sec in the inlet duct Isothermal throw values are given for terminal velocities of 0.8, 0.5 and 0.3m/sec respectively Air Diffusion FlowBar Throw data is based on 1200mm active section. For a 600mm section the throw values are 0.72 times those shown. For a 3000mm continuous length, the throw values are 1.7 times those shown and 1.8 for 3600mm units Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10dB, re 10-12 watts, for a 1200mm section. (See Table A for other lengths). For supply units used as a return, add 3 NC The tests were conducted with no Plenum effect for pressure or sound Throw values for High Throw units are based on a 1-way discharge from the slot Throws listed are for the 1-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slot

www.air-diffusion.co.uk 11

FlowBar with Air Diffusion Plenum Box - High Throw (HT) FL-10 with 150mm inlet 25mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 12 24 35 47 59 71 83 Total Pressure, Pa 2 8 18 32 50 72 98 Static Pressure, Pa 2 7 16 28 44 63 86 NC (Noise Criteria) <10 <10 <10 20 28 35 40 Throw, m 0.3-0.5-1.8 1-1.8-3 1.8-2.8-3.8 2.5-3 - 4.3 2.8-3.3-5 3-3.8-5.5 3.3-4 - 5.8 Air Flow, l/s 19 38 57 76 94 113 132 Total Pressure, Pa 2 7 16 28 44 64 87 Static Pressure, Pa 1 4 10 18 28 40 55 NC (Noise Criteria) <10 <10 <10 16 24 31 37 Throw, m 0.3-0.5-1.8 1-1.8-4 1.8-3 - 5 2.8-4 - 5.5 3.3-4.3-6 4-5 - 6.8 4.3-5.3-7.3 Air Flow, l/s 24 47 71 94 118 142 165 Total Pressure, Pa 2 9 19 34 53 77 104 Static Pressure, Pa 1 4 10 18 28 40 55 NC (Noise Criteria) <10 <10 <10 18 26 33 38 Throw, m 0.3-0.5-2.3 1-2.3-4.3 2.3-3.3-5.5 3-4.3-6 3.8-5 - 7 4.3-5.5-7.5 5-5.8-8.3 FL-15 with 150mm inlet 38mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 19 33 47 61 76 90 104 Total Pressure, Pa 4 13 26 45 68 96 128 Static Pressure, Pa 4 11 22 38 57 81 109 NC (Noise Criteria) <10 <10 16 25 33 40 46 Throw, m 0.5-1.5-2.8 1.5-2.5-3.8 2.5-3 - 4.3 2.8-3.8-5 3.3-4 - 5.5 3.3-4.3-6 3.8-4.5-6.5 Air Flow, l/s 38 57 76 94 113 132 151 Total Pressure, Pa 6 14 25 39 56 76 99 Static Pressure, Pa 4 8 14 22 32 44 57 NC (Noise Criteria) <10 <10 12 20 27 33 38 Throw, m 1-1.8-4 1.8-3 - 5 2.8-4 - 5.5 3.3-4.3-6 4-5 - 6.8 4.3-5.3-7.3 4.5-5.5-8 Air Flow, l/s 42 66 90 113 137 160 184 Total Pressure, Pa 6 15 28 44 64 88 116 Static Pressure, Pa 3 7 13 21 30 42 55 NC (Noise Criteria) <10 <10 12 20 27 33 39 Throw, m 1-1.8-4 1.8-3 - 5.3 2.8-4.3-6 3.3-5 - 6.8 4.3-5.3-7.3 4.5-5.8-8.3 5-6 - 8.5 FL-20 with 200mm inlet 51mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 24 40 57 73 90 106 123 Total Pressure, Pa 4 11 22 37 56 78 104 Static Pressure, Pa 4 10 20 34 51 71 95 NC (Noise Criteria) <10 <10 12 21 28 35 40 Throw, m 0.5-1.5-3 1.8-2.8-4 2.5-3.3-5 3-4 - 5.5 3.3-4.3-6 3.8-4.5-6.8 4-5 - 7 Air Flow, l/s 42 71 99 127 156 184 212 Total Pressure, Pa 4 11 21 35 52 73 97 Static Pressure, Pa 3 8 16 26 38 54 71 NC (Noise Criteria) <10 <10 20 29 36 42 48 Throw, m 1-1.8-4 2.3-3.3-5.5 3-4.5-6.5 4-5.3-7.3 4.5-5.5-8 5-6 - 8.5 5.5-6.8-9.5 Air Flow, l/s 47 78 109 139 170 201 231 Total Pressure, Pa 4 10 19 31 46 64 85 Static Pressure, Pa 2 6 12 20 29 41 54 NC (Noise Criteria) <10 <10 19 28 36 42 47 Throw, m 0.5-1.5-4 1.8-3 - 5.5 3-4.5-6.8 4-5.3-7.5 4.5-5.8-8.3 5.3-6.5-9.3 5.5-7 - 9.8 12 Air Diffusion FlowBar

FlowBar with Air Diffusion Plenum Box - High Throw (HT) FL-10 with 200mm inlet 25mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 24 35 47 59 71 83 94 Total Pressure, Pa 7 16 29 46 66 90 117 Static Pressure, Pa 7 16 28 44 63 86 112 NC (Noise Criteria) <10 <10 19 27 34 40 44 Throw, m 1-1.8-3 1.8-2.8-3.8 2.5-3 - 4.3 2.8-3.3-5 3-3.8-5.5 3.3-4 - 5.8 3.8-4.3-6 Air Flow, l/s 33 52 71 90 109 127 146 Total Pressure, Pa 4 10 19 30 44 60 80 Static Pressure, Pa 3 8 16 25 37 51 67 NC (Noise Criteria) <10 <10 13 22 29 35 40 Throw, m 0.5-1.5-3.3 1.8-2.8-4.5 2.5-3.8-5.5 3-4.3-6 3.8-4.5-6.8 4.3-5.3-7.3 4.5-5.5-7.5 Air Flow, l/s 38 61 85 109 132 156 179 Total Pressure, Pa 4 10 19 30 45 63 83 Static Pressure, Pa 3 8 15 24 35 49 65 NC (Noise Criteria) <10 <10 13 22 29 35 40 Throw, m 0.5-1.5-3.8 1.8-2.8-5 2.8-4 - 5.8 3.3-4.5-6.8 4.3-5.3-7.3 4.5-5.5-8 5-6 - 8.5 FL-15 with 200mm inlet 38mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 19 33 47 61 76 90 104 Total Pressure, Pa 4 12 24 40 61 86 115 Static Pressure, Pa 4 11 22 38 57 81 109 NC (Noise Criteria) <10 <10 14 24 32 38 45 Throw, m 0.5-1.5-2.8 1.5-2.5-3.8 2.5-3 - 4.3 2.8-3.8-5 3.3-4 - 5.5 3.3-4.3-6 3.8-4.5-6.5 Air Flow, l/s 38 61 85 109 132 156 179 Total Pressure, Pa 4 12 22 36 54 75 99 Static Pressure, Pa 4 9 18 30 44 61 81 NC (Noise Criteria) <10 <10 15 24 32 38 43 Throw, m 1-1.8-4 2.3-3 - 5 3-4.3-5.8 3.8-4.5-6.8 4.3-5.5-7.3 4.5-5.5-8 5-6 - 8.5 Air Flow, l/s 42 71 99 127 156 184 212 Total Pressure, Pa 4 11 21 35 53 74 99 Static Pressure, Pa 3 8 16 26 39 55 73 NC (Noise Criteria) <10 <10 14 24 31 37 43 Throw, m 1-1.8-4 2.3-3.3-5.5 3-4.5-6.5 4-5.3-7.3 4.5-5.5-8 5-6 - 8.5 5.5-6.8-9.5 FL-20 with 300mm inlet 51mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 24 42 61 80 99 118 137 Total Pressure, Pa 4 12 24 41 63 90 121 Static Pressure, Pa 4 11 24 41 62 88 119 NC (Noise Criteria) <10 <10 <10 13 20 27 32 Throw, m 0.5-1.5-3 1.8-2.8-4.3 2.8-3.8-5 3.3-4 - 5.8 3.8-4.5-6.5 4-5 - 7 4.3-5.3-7.3 Air Flow, l/s 42 78 113 149 184 219 255 Total Pressure, Pa 3 10 22 37 57 82 110 Static Pressure, Pa 3 10 20 35 54 76 103 NC (Noise Criteria) <10 <10 13 23 31 37 43 Throw, m 1-1.8-4 2.5-3.8-5.5 3.3-5 - 6.8 4.5-5.5-8 5-6 - 8.5 5.5-6.8-9.5 5.8-7.3-10 Air Flow, l/s 47 90 132 175 217 260 302 Total Pressure, Pa 3 9 20 34 53 76 103 Static Pressure, Pa 2 8 18 31 48 68 92 NC (Noise Criteria) <10 <10 15 25 33 39 45 Throw, m 0.5-1.5-4 2.5-3.8-6 3.8 -.5.3-7.3 5-6 - 8.5 5.5-6.8-9.5 5.8-7.3-10.3 6.5-8 - 11 www.air-diffusion.co.uk 13

FlowBar with Air Diffusion Plenum Box - High Throw (HT) FL-25 with 250mm inlet 63mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 47 68 90 111 132 153 175 Total Pressure, Pa 9 19 33 50 71 96 124 Static Pressure, Pa 9 18 31 47 67 90 117 NC (Noise Criteria) <10 <10 17 26 33 39 44 Throw, m 1.8-3 -4.3 2.8-3.8-5.3 3.3-4.3-6 4-5 - 6.8 4.3-5.3-7.3 4.5-5.5-8 5-6 - 8.5 Air Flow, l/s 66 104 142 179 217 255 293 Total Pressure, Pa 5 13 24 38 56 77 102 Static Pressure, Pa 4 10 19 31 45 62 82 NC (Noise Criteria) <10 <10 20 29 37 44 49 Throw, m 1.5-2.8-5.3 3-4.5-6.5 4.3-5.5-7.5 5-6 - 8.5 5.5-6.8-9.5 5.8-7.3-10 6.5-7.5-11 Air Flow, l/s 71 113 156 198 241 283 326 Total Pressure, Pa 4 11 21 33 49 68 90 Static Pressure, Pa 3 8 15 24 35 49 65 NC (Noise Criteria) <10 <10 18 28 36 43 49 Throw, m 1.3-2.8-5.5 3-4.5-6.8 4-5.5-8 5.3-6.5-8.8 5.8-7 - 9.8 6-7.5-10.8 6.8-8.3-11.5 FL-30 with 250mm inlet 76mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 59 80 101 123 144 165 186 Total Pressure, Pa 13 24 38 55 76 100 128 Static Pressure, Pa 12 22 35 52 71 94 119 NC (Noise Criteria) <10 <10 15 23 30 36 41 Throw, m 2.3-3.3-5 3-4 - 5.8 3.8-4.5-6.5 4-5 - 7 4.5-5.5-7.5 5-5.8-8.3 5.3-6 - 8.8 Air Flow, l/s 94 130 165 201 236 271 307 Total Pressure, Pa 10 18 30 44 61 81 103 Static Pressure, Pa 8 14 23 35 48 63 81 NC (Noise Criteria) <10 <10 17 25 32 39 44 Throw, m 2.5-4 - 6 3.8-5.3-7.3 4.5-5.8-8.3 5.3-6.5-9.3 5.8-7 - 9.8 6-7.3-10.3 6.5-8 - 11.3 Air Flow, l/s 104 146 189 231 274 316 359 Total Pressure, Pa 8 17 28 42 59 78 101 Static Pressure, Pa 6 12 20 29 41 55 71 NC (Noise Criteria) <10 <10 17 25 33 40 46 Throw, m 2.5-3.8-6.5 3.8-5.3-7.5 4.5-6 - 8.8 5.5-7 - 9.8 6-7.3-10.8 6.5-8 - 11.3 7-8.5-12.3 Pressures are given in Pascal (Pa) Isothermal throw values are given for terminal velocities of 0.8, 0.5 and 0.3m/ sec respectively Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10dB, re 10-12 watts The tests were conducted with the FlowBar and plenums as a composite assembly Throw values for High Throw units are based on a 1-way discharge from the slot Throws listed are for the 1-way air pattern. For divided air flow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slot Plenums not provided by Air Diffusion may demonstrate performance variations from the published data and therefore Air Diffusion would not be able to subsequently guarantee that performance matches our data 14 Air Diffusion FlowBar

FlowBar with Air Diffusion Plenum Box - High Throw (HT) FL-25 with 300mm inlet 63mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 47 68 90 111 132 153 175 Total Pressure, Pa 9 18 32 48 69 93 120 Static Pressure, Pa 9 18 31 47 67 90 117 NC (Noise Criteria) <10 <10 12 21 28 34 40 Throw, m 1.8-3 -4.3 2.8-3.8-5.3 3.3-4.3-6 4-5 - 6.8 4.3-5.3-7.3 4.5-5.5-8 5-6 - 8.5 Air Flow, l/s 66 106 146 186 227 267 307 Total Pressure, Pa 5 12 23 37 55 76 101 Static Pressure, Pa 4 11 20 33 49 68 90 NC (Noise Criteria) <10 <10 16 26 34 41 46 Throw, m 1.5-2.8-5.3 3-4.5-6.8 4.3-5.5-7.5 5.3-6 - 8.8 5.5-6.8-9.8 6-7.3-10.3 6.5-8 - 11.3 Air Flow, l/s 71 118 165 212 260 307 354 Total Pressure, Pa 4 10 20 33 49 68 91 Static Pressure, Pa 3 9 17 28 41 58 77 NC (Noise Criteria) <10 <10 16 26 34 41 47 Throw, m 1.3-2.8-5.5 3-4.5-7 4.3-5.8-8.3 5.5-6.8-9.5 5.8-7.3-10.3 6.5-8 - 11.3 7-8.5-12 FL-30 with 300mm inlet 76mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 59 80 101 123 144 165 186 Total Pressure, Pa 12 23 37 53 74 97 123 Static Pressure, Pa 12 22 35 52 71 94 119 NC (Noise Criteria) <10 <10 11 19 26 32 37 Throw, m 2.3-3.3-5 3-4 - 5.8 3.8-4.5-6.5 4-5 - 7 4.5-5.5-7.5 5-5.8-8.3 5.3-6 - 8.8 Air Flow, l/s 94 137 179 222 264 307 349 Total Pressure, Pa 9 18 31 48 68 92 119 Static Pressure, Pa 8 16 28 42 60 81 105 NC (Noise Criteria) <10 <10 16 26 33 40 45 Throw, m 2.5-4 - 6 3.8-5.3-7.3 5-6 - 8.5 5.5-6.8-9.5 6-7.3-10.3 6.5-8 - 11.3 7-8.5-12 Air Flow, l/s 104 156 208 260 311 363 415 Total Pressure, Pa 7 16 29 45 64 88 114 Static Pressure, Pa 6 13 24 37 53 73 95 NC (Noise Criteria) <10 <10 17 26 34 41 47 Throw, m 2.5-3.8-6.5 3.8-5.5-8 5-6.5-9.3 5.8-7.3-10.3 6.5-8 - 11.3 7-8.5-12.3 7.5-9.3-13 Pressures are given in Pascal (Pa) Isothermal throw values are given for terminal velocities of 0.8, 0.5 and 0.3m/ sec respectively Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10dB, re 10-12 watts The tests were conducted with the FlowBar and plenums as a composite assembly Throw values for High Throw units are based on a 1-way discharge from the slot Throws listed are for the 1-way air pattern. For divided air flow, select the airflow in each direction according to the number of slots aimed in that direction, with the total air flow apportioned between slot Plenums not provided by Air Diffusion may demonstrate performance variations from the published data and therefore Air Diffusion would not be able to subsequently guarantee that performance matches our data www.air-diffusion.co.uk 15

16 Air Diffusion FlowBar

www.air-diffusion.co.uk 17

Performance Data - Jet Throw (JT) Continuous Slot Plenum Jet Throw (JT) Data based on active section 1200 long FL-10 25mm Slot Width Air Flow, l/s-m 31 62 93 124 155 186 217 Static Pressure, Pa 2 7 15 27 42 61 83 NC (Noise Criteria) <10 <10 17 24 28 32 36 Throw, m 0.5-1 - 2.3 1.3-2.3-4 2.3-3 - 5.8 2.8-4 - 6.8 3.3-5.3-7.3 4-5.8-8 4.5-6 - 8.8 FL-15 38mm Slot Width Air Flow, l/s-m 46 93 139 186 232 279 325 Static Pressure, Pa 2 8 18 31 49 70 95 NC (Noise Criteria) <10 <10 17 22 28 34 40 Throw, m 0.5-1.3-2.3 1.5-2.3-4.5 2.3-3.3-6.8 3-4.5-8 3.8-5.5-9.3 4.5-6.8-9.8 5.3-7.5-10.8 FL-20 51mm Slot Width Air Flow, l/s-m 54 116 178 240 302 364 426 Static Pressure, Pa 1 7 15 28 44 64 88 NC (Noise Criteria) <10 <10 18 24 29 33 37 Throw, m 0.3-1 - 2.3 1.5-2.5-4.5 2.5-3.8-7 3-5.- 9.3 4-6 - 10.3 5-7.3-11.3 5.5-8.5-12.3 FL-25 63mm Slot Width Air Flow, l/s-m 62 147 232 317 402 488 573 Static Pressure, Pa 1 7 17 31 51 74 102 NC (Noise Criteria) <10 <10 18 25 30 35 39 Throw, m 0.3-1 - 2.3 1.8-2.5-5.3 2.8-4 - 8 3.8-5.5-10.8 4.5-7 - 12 5.5-8.5-13 6.8-10 - 14 FL-30 76mm Slot Width Air Flow, l/s-m 77 178 279 379 480 580 681 Static Pressure, Pa 1 7 17 31 50 73 100 NC (Noise Criteria) <10 <10 15 24 30 35 40 Throw, m 0.3-1 - 2.5 1.8-2.8-5.5 2.8-4.3-8.5 4-5.8-11.5 5-7.3-12.8 6-8.8-14.3 7-10.3-15.5 Table A. NC Correction for, mm 600 1200 1800 2400 3000 Supply -3 0 +2 +3 +5 Return 0 +3 +5 +6 +8 Table B. Correction Multiplier for, mm 600 1200 2400 3000 3600 Throw Correction 0.72 1 1.5 1.7 1.8 Pressures are given in Pascal (Pa) Pressure loss data assumes a duct velocity is less than 4m/sec in the inlet duct Isothermal throw values are given for terminal velocities of 0.8, 0.5 and 0.3m/sec respectively Throw data is based on 1200mm active section. For a 600mm section the throw values are 0.72 times those shown. For a 3000mm continuous length, the throw values are 1.7 times those shown and 1.8 for 3600mm units Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10dB, re 10-12 watts, for a 1200mm section. See Table A for other lengths For supply units used as a return, add 3 NC The tests were conducted with no Plenum effect for pressure or sound Throw values for Jet Throw units are based on the pattern controller set at 0 discharge vertical flow 18 Air Diffusion FlowBar

www.air-diffusion.co.uk 19

FlowBar with Air Diffusion Plenum Box - Jet Throw (JT) FL-10 with 200mm inlet 25mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 24 45 66 87 109 130 151 Total Pressure, Pa 3 11 23 41 63 90 121 Static Pressure, Pa 3 10 21 36 56 80 108 NC (Noise Criteria) <10 <10 16 23 29 34 39 Throw, m 0.5-1 - 1.8 1.3-1.8-3.3 1.5-2.5-4.3 2.3-3.3-5 2.8-4 - 5.5 3.3-4.3-6 3.8-4.5-6.8 Air Flow, l/s 47 83 118 153 189 224 260 Total Pressure, Pa 4 12 25 41 63 88 119 Static Pressure, Pa 3 8 17 28 42 60 80 NC (Noise Criteria) <10 <10 18 25 30 34 38 Throw, m 1-1.3-2.5 1.5-2.3-4.3 2.3-3 - 5.8 2.8-4 - 6.8 3.3-5.3-7.3 4-5.8-8 4.5-6 - 8.5 Air Flow, l/s 52 92 132 172 212 252 293 Total Pressure, Pa 4 11 23 40 60 85 114 Static Pressure, Pa 2 6 13 23 34 48 65 NC (Noise Criteria) <10 <10 17 24 29 33 37 Throw, m 1-1.3-2.5 1.5-2.3-4.3 2.3-3 - 6 2.8-4 - 7 3.3-5.3-8 4-6 - 8.5 4.5-6.5-9.3 FL-15 with 200mm inlet 38mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 28 52 76 99 123 146 170 Total Pressure, Pa 3 11 24 42 64 91 122 Static Pressure, Pa 2 7 14 24 37 52 70 NC (Noise Criteria) <10 <10 <10 16 24 31 37 Throw, m 0.3-1 -1.5 1-1.5-2.8 1.5-2.3-4.3 1.8-2.8-5.3 2.3-3.3-5.8 2.8-4 - 6.5 3-4.5-7 Air Flow, l/s 57 85 113 142 170 198 227 Total Pressure, Pa 8 17 31 48 70 95 124 Static Pressure, Pa 2 4 8 12 18 24 31 NC (Noise Criteria) <10 <10 <10 <10 16 22 27 Throw, m 0.5-1.3-2.3 1.3-1.5-3.3 1.5-2.3-4.5 1.8-2.8-5.5 2.3-3.3-6.8 2.5-4 - 7.5 3-4.5-8 Air Flow, l/s 66 94 123 151 179 208 236 Total Pressure, Pa 10 20 33 50 71 95 122 Static Pressure, Pa 2 3 6 9 13 17 22 NC (Noise Criteria) <10 <10 <10 <10 12 17 22 Throw, m 0.5-1.3-2.5 1.3-1.5-3.3 1.5-2.3-4.3 1.8-2.8-5.3 2.3-3 - 6.5 2.5-3.8-7.3 2.8-4.3-8.3 FL-20 with 200mm inlet 51mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 33 66 99 132 165 198 231 Total Pressure, Pa 2 8 18 33 51 74 100 Static Pressure, Pa 1 6 13 23 36 51 70 NC (Noise Criteria) <10 <10 14 21 27 33 38 Throw, m 0.3-0.5-1.5 1-1.5-3 1.5-2.3-4.5 2.3-3 - 6 2.5-3.8-7 3-4.5-7.5 3.8-5.3-8.3 Air Flow, l/s 66 113 160 208 255 302 349 Total Pressure, Pa 4 12 23 39 58 82 110 Static Pressure, Pa 1 4 8 14 21 30 40 NC (Noise Criteria) <10 12 21 27 32 36 40 Throw, m 0.3-1 - 2.3 1.3-1.8-3.8 1.8-2.8-5.3 2.3-3.3-6.8 2.8-4.3-8.3 3.3-5 - 9.3 3.8-5.8-10 Air Flow, l/s 71 123 175 227 278 330 382 Total Pressure, Pa 4 12 24 40 61 85 114 Static Pressure, Pa 1 3 6 11 16 23 30 NC (Noise Criteria) <10 13 21 27 32 36 40 Throw, m 0.3-1 - 2.3 1-1.8-3.8 1.8-2.5-5.3 2.3-3.3-6.8 2.8-4 - 8.3 3-5 - 9.5 3.8-5.5-10.3 20 Air Diffusion FlowBar

FlowBar with Air Diffusion Plenum Box - Jet Throw (JT) FL-10 with 250mm inlet 25mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 24 45 66 87 109 130 151 Total Pressure, Pa 3 10 22 38 59 84 114 Static Pressure, Pa 3 10 21 36 56 80 108 NC (Noise Criteria) <10 <10 16 22 28 33 38 Throw, m 0.5-1 - 1.8 1.3-1.8-3.3 1.5-2.5-4.3 2.3-3.3-5 2.8-4 - 5.5 3.3-4.3-6 3.8-4.5-6.8 Air Flow, l/s 47 85 123 160 198 236 274 Total Pressure, Pa 3 10 21 37 56 79 107 Static Pressure, Pa 3 9 18 31 47 66 89 NC (Noise Criteria) <10 <10 18 25 30 35 39 Throw, m 1-1.3-2.5 1.5-2.3-4.5 2.3-3.3-5.8 2.8-4.3-6.8 3.8-5.3-7.5 4.3-5.8-8.3 5-6.5-8.8 Air Flow, l/s 52 99 146 193 241 288 335 Total Pressure, Pa 3 10 21 37 58 82 112 Static Pressure, Pa 2 7 16 28 44 63 85 NC (Noise Criteria) <10 <10 19 26 31 35 40 Throw, m 1-1.3-2.5 1.5-2.5-5 2.5-3.3-6.5 3-4.5-7.3 4-5.8-8.3 4.5-6.5-9.3 5.5-7 - 9.8 FL-15 with 300mm inlet Air Flow, l/s 28 59 90 120 151 182 212 38mm Slot Width 600mm 1200mm 1500mm Total Pressure, Pa 2 9 20 37 58 84 115 Static Pressure, Pa 2 8 20 35 55 80 110 NC (Noise Criteria) <10 <10 <10 18 27 35 43 Throw, m 0.3-1 -1.5 1.3-1.5-3.3 1.5-2.5-5 2.3-3.3-5.8 2.8-4.3-6.8 3.3-5.3-7.3 4-5.5-8 Air Flow, l/s 57 113 170 227 283 340 396 Total Pressure, Pa 2 9 21 37 58 83 113 Static Pressure, Pa 2 8 18 31 49 70 95 NC (Noise Criteria) <10 <10 10 21 30 37 45 Throw, m 0.5-1.3-2.3 1.5-2.3-4.5 2.3-3.3-6.8 3-4.5-8 3.8-5.5-9.3 4.8-6.8-9.8 5.3-7.5-10.8 Air Flow, l/s 66 132 198 264 330 396 463 Total Pressure, Pa 2 9 20 35 55 79 107 Static Pressure, Pa 2 7 15 27 42 61 83 NC (Noise Criteria) <10 <10 10 21 29 36 43 Throw, m 0.5-1.3-2.5 1.5-2.5-4.5 2.5-3.3-7 3-4.5-8.8 4-5.8-9.8 4.5-7 - 10.8 5.5-8.3-11.5 FL-20 with 300mm inlet 51mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 33 76 118 160 203 245 288 Total Pressure, Pa 2 8 20 36 58 85 117 Static Pressure, Pa 1 7 8 34 54 79 108 NC (Noise Criteria) <10 <10 <10 17 25 31 36 Throw, m 0.3-0.5-1.5 1.3-1.8-3.3 1.8-2.8-5.5 2.5-3.8-6.8 3-4.5-7.5 3.8-5.5-8.3 4.3-6.5-9.3 Air Flow, l/s 66 137 208 278 349 420 491 Total Pressure, Pa 2 8 19 34 54 77 106 Static Pressure, Pa 1 6 14 25 40 58 79 NC (Noise Criteria) <10 <10 17 24 31 37 41 Throw, m 0.3-1 - 2.3 1.5-2.3-4.5 2.3-3.3-6.8 3-4.5-8.8 3.8-5.8-10 4.5-6.8-11 5.3-8 - 12 Air Flow, l/s 71 156 241 326 411 496 580 Total Pressure, Pa 2 8 19 34 54 79 108 Static Pressure, Pa 1 5 12 22 35 51 70 NC (Noise Criteria) <10 <10 19 26 32 38 43 Throw, m 0.3-1 - 2.3 1.5-2.3-4.5 2.5-3.3-7 3-5 - 9.5 4-6 - 11 5-7.3-12 5.5-8.5-12.8 www.air-diffusion.co.uk 21

FlowBar with Air Diffusion Plenum Box - Jet Throw (JT) FL-25 with 250mm inlet 63mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 38 85 132 179 227 274 321 Total Pressure, Pa 2 8 19 35 55 81 111 Static Pressure, Pa 1 6 15 27 43 63 87 NC (Noise Criteria) <10 <10 <10 13 21 28 34 Throw, m 0.3-0.5-1.5 1.3-1.8-3.3 1.8-2.8-5.3 2.5-3.8-7 3-4.5-8 3.8-5.5-8.8 4.3-6.5-9.5 Air Flow, l/s 71 142 212 283 354 425 496 Total Pressure, Pa 2 9 20 36 56 80 109 Static Pressure, Pa 1 4 9 17 26 38 52 NC (Noise Criteria) <10 <10 <10 17 24 30 36 Throw, m 0.3-0.5-2.3 1.3-2.3-4 2.3-3 - 6 2.8-4 - 8 3.3-5 - 10 4-6 - 11 4.5-7 - 12 Air Flow, l/s 76 156 236 316 396 477 557 Total Pressure, Pa 2 9 21 37 58 84 114 Static Pressure, Pa 1 3 7 13 21 31 42 NC (Noise Criteria) <10 <10 <10 16 24 30 36 Throw, m 0.3-0.5-1.8 1.3-1.8-4 2.3-3 - 6 2.8-4 - 8 3.3-5.3-10 4-6 - 11.5 4.5-7 - 12.5 FL-30 with 250mm inlet 76mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 47 101 156 210 264 319 373 Total Pressure, Pa 2 8 20 36 57 83 113 Static Pressure, Pa 1 6 14 26 41 59 81 NC (Noise Criteria) <10 <10 <10 <10 15 24 31 Throw, m 0.3-0.5-1.8 1.3-1.8-3.8 1.8-2.8-5.5 2.5-3.8-7.5 3-5 - 8.8 3.8-5.8-9.5 4.5-6.8-10.3 Air Flow, l/s 94 170 245 321 396 472 547 Total Pressure, Pa 3 11 23 39 60 85 114 Static Pressure, Pa 1 4 9 15 23 32 44 NC (Noise Criteria) <10 <10 <10 <10 13 21 27 Throw, m 0.3-1 - 2.5 1.3-2.3-4.3 2.3-3 - 6 2.8-4 - 8.3 3.3-5 - 10 4-6 - 11.5 4.5-7 - 12.5 Air Flow, l/s 113 193 274 354 434 514 595 Total Pressure, Pa 4 12 25 41 62 87 116 Static Pressure, Pa 1 3 7 12 18 25 33 NC (Noise Criteria) <10 <10 <10 <10 10 18 24 Throw, m 0.3-1 - 2.5 1.3-2.3-4.3 2.3-3 - 6 2.8-4 - 8 3.3-5 - 9.8 4-5.8-11.5 4.5-6.8-13 Pressures are given in Pascal (Pa) Isothermal throw values are given for terminal velocities of 0.8, 0.5 and 0.3m/ sec respectively Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10dB, re 10-12 watts The tests were conducted with the FlowBar and plenums as a composite assembly Plenums not provided by Air Diffusion may demonstrate performance variations from the published data and therefore Air Diffusion would not be able to subsequently guarantee that performance matches our data 22 Air Diffusion FlowBar

FlowBar with Air Diffusion Plenum Box - Jet Throw (JT) FL-25 with 300mm inlet 63mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 38 90 142 193 245 297 349 Total Pressure, Pa 1 8 19 36 57 84 116 Static Pressure, Pa 1 7 17 31 51 74 102 NC (Noise Criteria) <10 <10 <10 12 20 26 33 Throw, m 0.3-0.5-1.5 1.3-1.8-3.8 1.8-2.8-5.8 2.8-4 - 7.3 3.3-5 - 8.3 4-6 - 9.3 4.5-7 - 10 Air Flow, l/s 71 158 245 333 420 507 595 Total Pressure, Pa 2 8 19 36 57 83 114 Static Pressure, Pa 1 5 13 23 37 54 74 NC (Noise Criteria) <10 <10 <10 18 26 32 38 Throw, m 0.3-0.5-2.3 1.5-2.3-4.5 2.5-3.3-7 3-5 - 9.5 4-6 - 11 5-7.3-12.3 5.5-8.5-13 Air Flow, l/s 76 175 274 373 472 571 670 Total Pressure, Pa 1 8 19 34 55 81 111 Static Pressure, Pa 1 4 10 19 30 44 60 NC (Noise Criteria) <10 <10 <10 18 26 32 38 Throw, m 0.3-0.5-1.8 1.5-2.3-4.5 2.5-3.3-7 3-5 - 9.5 4-6 - 11.5 5-7.3-12.8 5.8-8.5-13.8 FL-30 with 300mm inlet 76mm Slot Width 600mm 1200mm 1500mm Air Flow, l/s 47 106 165 224 283 342 401 Total Pressure, Pa 2 8 19 35 56 81 112 Static Pressure, Pa 1 7 16 29 47 68 94 NC (Noise Criteria) <10 <10 <10 <10 15 24 31 Throw, m 0.3-0.5-1.8 1.3-1.8-3.8 1.8-3 - 5.8 2.8-4 - 8 3.3-5.3-9.3 4-6 - 9.8 5-7.3-10.8 Air Flow, l/s 94 189 283 378 472 566 661 Total Pressure, Pa 2 9 21 37 58 83 113 Static Pressure, Pa 1 5 12 21 32 47 63 NC (Noise Criteria) <10 <10 <10 <10 17 25 32 Throw, m 0.3-1 - 2.5 1.5-2.5-5 2.5-3.8-7.3 3-5 - 9.5 4-6 - 11.5 5-7.3-12.8 5.5-8.3-13.8 Air Flow, l/s 113 217 321 425 529 632 736 Total Pressure, Pa 3 10 21 37 58 82 112 Static Pressure, Pa 1 4 10 17 26 37 50 NC (Noise Criteria) <10 <10 <10 <10 15 24 30 Throw, m 0.3-1 - 2.5 1.5-2.5-5 2.5-3.8-7.3 3.3-5 - 9.8 4-6 - 12 5-7 - 13.5 5.5-8.3-14.8 Pressures are given in Pascal (Pa) Isothermal throw values are given for terminal velocities of 0.8, 0.5 and 0.3m/sec respectively Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10dB, re 10-12 watts The tests were conducted with the FlowBar and plenums as a composite assembly Plenums not provided by Air Diffusion may demonstrate performance variations from the published data and therefore Air Diffusion would not be able to subsequently guarantee that performance matches our data www.air-diffusion.co.uk 23

24 Air Diffusion FlowBar

www.air-diffusion.co.uk 25

Standard Fixing Details High Throw (HT) Details Dimensions FL-10-HT (25mm) W = 70mm Dimensions FL-15-HT (38mm) W = 95mm Dimensions FL-20-HT (51mm) W = 121mm Dimensions FL-25-HT (63.5mm) W = 146mm Dimensions FL-30-HT (76mm) W = 171mm Optional F6 Fixing (HT) Details Dimensions FL-10-HT (25mm) W = 78mm Dimensions FL-15-HT (38mm) W = 103mm Dimensions FL-20-HT (51mm) W = 129mm Jet Throw (JT) Details Dimensions FL-25-HT (63mm) W = 154mm Dimensions FL-30-HT (76mm) W = 179mm Flowbar Border 66 Installation Detail Dimensions FL-10-JT (25mm) W = 78mm Dimensions FL-15-JT (38mm) W = 103mm Dimensions FL-20-JT (51mm) W = 129mm Dimensions FL-25-JT (63mm) W = 154mm Dimensions FL-30-JT (76mm) W = 179mm Flowbar Border 66 Installation Detail 26 Air Diffusion FlowBar

Dimensions & Details - High Throw (HT) Type 11 FL-10/15/20/25/30 Type 22 FL-10/15/20/25/30 FL-10/15/20/25/30 - HT Border Type 11 F S W H 1 Slot (25mm) 22 25 70 43 1 Slot (38mm) 28.5 38 95 43 1 Slot (51mm) 35 51 121 43 1 Slot (63mm) 41 63 146 58.5 1 Slot (76mm) 47.5 76 171 58.5 FL-10/15/20/25/30 - HT Border Type 22 F S W H 1 Slot (25mm) 41 25 70 43 1 Slot (38mm) 48 38 95 43 1 Slot (51mm) 54 51 121 43 1 Slot (63mm) 54 63 146 61 1 Slot (76mm) 60 76 171 61 Type 55 FL-10/15/20/25/30 Type 66 FL-10/15/20/25/30 FL-10/15/20/25/30 - HT Border Type 55 F S W H 1 Slot (25mm) 14 25 70 61.5 1 Slot (38mm) 21 38 95 61.5 1 Slot (51mm) 27 51 121 61.5 1 Slot (63mm) 31 63 146 61.5 1 Slot (76mm) 38 76 171 61.5 FL-10/15/20/25/30 - HT Border Type 66 F S W H 1 Slot (25mm) 35 25 70 43 1 Slot (38mm) 41 38 95 43 1 Slot (51mm) 48 51 121 43 1 Slot (63mm) 54 63 146 59 1 Slot (76mm) 60 76 171 59 www.air-diffusion.co.uk 27

Dimensions & Details - Jet Throw (JT) Type 66 FL-10/15/20/25/30 Type 22 FL-10/15/20/25/30 H FL-10/15/20/25/30 - JT Border Type 66 F S W H O 1 Slot (25mm) 35 25 70 43 76 1 Slot (38mm) 41 38 95 43 102 1 Slot (51mm) 48 51 121 43 127 1 Slot (63mm) 54 63 146 59 152 1 Slot (76mm) 60 76 171 59 178 FL-10/15/20/25/30 - JT Border Type 22 F S W H 1 Slot (25mm) 41 25 70 43 1 Slot (38mm) 48 38 95 43 1 Slot (51mm) 54 51 121 43 1 Slot (63mm) 54 63 146 61 1 Slot (76mm) 60 76 171 61 Dimensions & Details - Slot Runs Border Type 11, 66 Slot Run Border Type 11, 22 & 55 Slot Run 28 Air Diffusion FlowBar

Dimension & Details - End Border Configurations Border Type 11 & 66 Border Type 11, 22 & 55 Optional Return Light Shield Painted Black Optional Blanking Plates - FBBO Blank-off FBR - 10 (25mm Slot) FBR - 15 (38mm Slot) FBR - 20 (51mm Slot) FBR - 25 (63mm Slot) FBR - 30 (76mm Slot) FBBO - 10 (25mm Slot) FBBO - 15 (38mm Slot) FBBO - 20 (51mm Slot) FBBO - 25 (63mm Slot) FBBO - 30 (76mm Slot) www.air-diffusion.co.uk 29

Standard Installation Details - High Throw (HT) & Jet Throw (JT) UHC Upper Hanger Clip The upper hanger clip is used to suspend the FlowBar assembly from the structure. The clip is designed to utilize standard ceiling hanger wire. UHC is for 1 slot only and FL-10, 15 and 20. H2 Hard Ceiling Clip The H2 hard ceiling clip is used to mount the FlowBar assembly with border type 55 when 25mm thick plasterboard ceiling is required. H3 Hard Ceiling Clip The H3 hard ceiling clip can be used to mount the FlowBar assembly with border type 22 when a standard plasterboard ceiling is required. Spline Support Clip The SS1 spline clip is also used to adjoin multiple sections of FlowBar when continuous lengths are desired. 30 Air Diffusion FlowBar

Standard Installation for Solid (Plasterboard) Type Ceiling Systems Standard Types 22 Plaster Frame Installation Standard Installation for Suspended Ceiling Systems Standard Plenum Box Installation System (HT Only) www.air-diffusion.co.uk 31

Standard Installation Details - Jet Throw (JT) only Bracket Diffuser Assembly Diffuser Installation without plenum Mounting Bracket Diffuser Flange Ceiling Concealed Fastening Plenum Installation Diffuser Installation with plenum Attach Hanger Wire/Rods to Plenum Support Brackets Ceiling Mounting bracket catches in Hemmed Edge of Plenum Opening Diffuser flange overlaps ceiling opening Hemmed Edge of Plenum Plenum FlowBar Model Ceiling Opening dimensions for border type 66 1-Slot FL - 10 76 FL - 15 102 FL - 20 127 FL - 25 152 FL - 30 178 32 Air Diffusion FlowBar

Ordering Information - FlowBar Slot Diffuser Example Frame Diffuser Model No. of Slots Slot Width End Flanges Fix Optional Fix Frame Finish Blade Finish HT 1 15 E1 F6 SP 3 66 4 JT 1 10 15 20 25 30 F6 F9 U Bracket fi xing Toggle Fix 3 Standard White matt. Type 66 border 4 Standard Black Type 22, 55 & 11 Border 6 Other colours available to special order 66 Surface Mounting 22 Plaster frame 55 Plaster frame (deep) 11 Flangeless E0 E1 E2 EP1 EP2 ME Open End End border one end End border two ends End plate one end End Plate two ends Mitred End SP H2 H3 UHC Special Fixing Hard Ceiling clip (25mm) Hard Ceiling clip (12.5mm) Upper hanger clip (Border Type 66) 4 Standard Black 6 Other colours available to special order The model described in the example above would be: 66 - HT -1-15 - E1 - F6-3 - 4 FlowBar Installation Manual For the comprehensive installation, operation and maintenance (IOM) manual, please visit our website: www.air-diffusion.co.uk where the manual can be downloaded as a PDF fi le. www.air-diffusion.co.uk 33

Plenum Boxes Supplied with 6mm lining as standard with side entry spigot. Plenum boxes can be supplied without lining or with 12mm lining as an option. Apply to sales office for price. Specifications Material/Finish Standard is a minimum of 0.7mm thick galvanised steel. Construction Plenum boxes are generally fabricated in 3 sections, which are either mechanically joined or spot welded to form an airtight seal. As standard, spigots are side entry and located centrally. All boxes are supplied with stepped edges. F9 (HT) or hemmed edges F6 (JT) as standard. Installation Options Fixing lugs can be factory fitted if preferred or special fi xing methods (by others) may be used. For plenum boxes having flush ends separate hanging brackets/fi xing lugs need to be fitted to allow independent support of diffuser and plenum box. Accessories Joggled style plenum boxes or pan adapters Spigot dampers include manual quadrant or cord operated Options for: Unlined; 6mm or 12mm thick Class O internal lining Equalising grids (50% free area perforated mesh) Fixing lugs or special fi xings (by others) High Throw (HT) Plenum Jet Throw (JT) Plenum 34 Air Diffusion FlowBar

Pressure Drops & Sound Rating The pressure drop given is for supply diffuser with damper fully open. When the diffuser is installed with plenum box, the pressure loss of the box has to be added to the diffuser. Spigot Velocity m/s 1.5 2.0 2.5 3.0 3.5 4.0 Pressure Drop Pa* 2 4 6 8 12 16 Sound Power Level NR* - - 25 30 35 40 *The figures given are approximate - dependent upon spigot entry conditions. Plenum Box Spigot Volumes (l/s) Spigot Velocity m/s Diameter (mm) 1.5 2.0 2.5 3.0 3.5 4.0 100 10 15 19 22 26 30 125 18 24 30 35 41 47 150 25 34 42 51 60 68 175 35 46 58 70 82 94 200 45 60 75 91 109 121 225 58 77 96 117 137 151 250 71 95 120 142 170 191 275 86 115 145 172 205 230 300 103 139 172 208 240 275 325 120 160 200 240 280 320 350 140 188 235 280 328 375 400 185 245 310 370 430 495 www.air-diffusion.co.uk 35

Plenum Box Dimensions Type PBL-1 Order Details C H L W D LH RH X - - - - - - - Angle Bracket fi xing available if required. Optional rectangular or flat oval spigots* available (minimum height 100mm). Type PBL-1 for F6 fixing Order Details C H L W D LH RH X - - - - - - - 36 Air Diffusion FlowBar

Accessories Manual Quadrant Control Damper 200 50 50 NDD 50 60 50 75 Model Ref Nominal Duct Diameter* Open Blade Protrusion (mm) DW144 Casing Leakage Class Weight (Kg) CB 100 C 0.56 CB 125 C 0.71 CB 150 C 0.85 CB 160 C 0.91 CB 200 C 1.17 CB 250 20.5 C 1.53 CB 300 45.5 C 1.92 CB 315 53 C 2.05 CB 350 70.5 C 2.35 CB 355 73 C 2.40 * NDD: Nominal duct diameter. Actual sizes are in accordance with BS EN 1506. www.air-diffusion.co.uk 37

Accessories Plenum Box Detail Lever Operated Damper Option Type PBL-1 65 65 38 Air Diffusion FlowBar

Ordering Information - Plenum Boxes Example Model Internal Lining Spigot Damper Options Dimensions PBL-1 U N 0 See example below PBL-1 Linear Plenum Box with either a circular or square side entry spigot PBL-2 Linear Plenum Box having either a circular or square top entry spigot PBL-3 Linear Plenum Box with joggle section having either a circular or square side entry spigot PBL-4 Linear Plenum Box with joggle section having either a circular or square top entry spigot N Q Z C Plain spigot no damper Quadrant damper Lever operated opposed blade damper Cord operated damper fitted to spigot 0 2 3 No options Equalising grid Fixing lugs fitted to side of plenum U L Standard Unlined Plenum Box 6mm Class O Internal Lining 4 5 6 Profi le ends on each end of plenum Hemmed Edge for concealed strap fi xing Plenum retaining clips (HT Only) Dimensions PBL-1, PBL-2, Example Neck Size Plenum Height Circular Spigot Diameter OR (Sq./Rect. Spigot Width x Height) Centre Line of Spigot L x W H Diameter C x E G 1000 x 95 350 250 0 0 www.air-diffusion.co.uk 39

actionair air diffusion airfiltrera airolution naco Stourbridge Rd, Bridgnorth, WV15 5BB, Shropshire, UK Tel: +44 (0)1746 761921 Email: sales@air-diffusion.co.uk Website: air-diffusion.co.uk The statements made in this brochure or by our representatives in consequence of any enquires arising out of this document are given for information purposes only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations, which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. LNNN00394 (1.3-07.18)