Select from 3 product types and 14 protocols.

Similar documents
Fieldbus System Variations

Reduced-wiring Fieldbus System (Serial Transmission)

Fieldbus System (Output device for driving 5 port solenoid valves)

Gateway Type Serial Transmission System

Fieldbus System (Gateway Decentralized Type)

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

New Concept Connector Type Manifold

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

A K 3 E D G

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

503 series. GENERAL Operating pressure

SV1000/2000/3000/4000

FIELDBUS ELECTRONICS 580 Electronics (Series : M7 to 1/2 (G or NPT) or with push-in fittings Ø4 to 10 mm)

Series ITV1000/2000/3000

Standard Product Program. AirLINE & AirLINE Quick Type 8640 & Type 8644

Series SY3000/5000/7000

SI unit for AS-Interface EX250-SAS#

ALL PRODUCTS CAT.E00-1I

Unidrive M700 Class leading performance with onboard real-time Ethernet

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Series SY3000/5000/7000

5 Port Solenoid Valve

Valve terminals MPA-F

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

ABB Drives ACS550-U1-059A-2, 20 HP, 3PH, 200 VAC, Wall Mount VFD

SI unit for EtherCAT. EX260 Series

PREVIEW. Fieldbus System for Distributed I/O NEW PRODUCTS

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Fieldbus Electronics. G3 Communication Node and I/O 580 Communication Node.

5 Port Solenoid Valve

5 Port Solenoid Valve

ACCESSORIES FOR GEFLEX SYSTEM

Valve terminals CPV, Compact Performance

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

SMC guide to ATEX compliant products

EUROPE RA-SERIES. Arc welding robots up to 10 kg payload

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Rexroth IndraDrive Cs

Zone Safety Manifold. Fielbus Electronics Availability, design and specifications are subject to change without notice. All rights reserved.

SI unit for Ethernet POWERLINK

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

EB 80 SUMMARY EB 80 DISTRIBUTORS P EB 80 ELECTRO-PNEUMATIC SYSTEM PAGE 4 P EB 80 BASIC PAGE 13 P EB 80 - SIGNAL MODULES - S PAGE 16

EX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series

Valve terminals MPA-L

Centralised Control Panel

2017 Advanced Energy Industries, Inc. THYRO-S DIGITAL THYRISTOR SWITCH 8 TO 350 A

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

Multipole and Fieldbus

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

The reliable choice for the Oil and Gas industries

White Paper Improved Diagnostics from Decentralized Solenoid Valves and I/O Systems

ABB micro drives Product guide

5 Port Solenoid Valve

5 Port Solenoid Valve

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

PRODUCTS AND CAPABILITIES ACTUATION & CONTROLS ACTUATION & CONTROLS PRODUCTS AND CAPABILITIES

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

* Evaluated by TÜV Rheinland (Report No. 968/FSP /16) in accordance with ISO and ISO

PNEUMATIC VALVE MANIFOLDS 11 mm - Series 501 M7 or with push-in fittings Ø6 mm

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

2005 / 2012 / 2035 Series

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

SI unit for DeviceNet TM PRODUCT NAME. SI unit EX250-SDN1 EX250-SDN1-X102

503 series. Level C to +50 C spool & sleeve metal-to-metal sealing. Aluminium, E-coating treatment

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Valve terminals MPA-L

Valve terminal CPA, Compact Performance

5 Port Solenoid Valve

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

Valve Manifolds Series

Valve terminals MPA-S

ST AND SW TORQUE ROTARY UNITS

High performance Vector Control. Ratings. System configuration

SOLUTIONS FOR THE TEXTILE INDUSTRY DRIVES AND CONTROLLERS FOR TEXTILE MACHINERY

Valve terminals CPV-SC, Smart Cubic

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Sitras SCS, -RCI, -FFP, -TTU

DISTRIBUTORS. n o p q. hdm + multi-pole connection TECHNICAL DATA COMPONENTS

Latest News ECDriveS 24 V drive system for roller conveyors

Keeping up with Industry 4.0. By Frederik Langenhoven

PICK & PLACE ROBOTS. Full line-up of 6 models in all from 2 axes type to 4 axes type. Structure X axis Y axis Z axis R axis

Altivar 31 AC Drives. Simply Smart! For 3-phase asynchronous motors from 0.25 to 20 HP

Say hello to better web control.

Linear Motor Series P10-70

Пневмоострова Burkert

Series SY3000/5000 How to Order Manifold

Series SV1000/2000/3000/4000

VDCI mixproof valve technical description

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

EX510 Series Serial System Technical Specifications

HIGH-CURRENT POWER SUPPLIES

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

Transcription:

Fieldbus System Select from 3 product types and 14 protocols. * Some protocols are not UL-compliant. Type 1 Type 2 Type 3 Output type for solenoid valves Gateway type Integrated input-output type CAT.E02-27A

What is a Fieldbus (Serial Transmission)? A Fieldbus (serial transmission) is a network communications system that uses a single communication cable to send and receive ON/OFF signals from numerous solenoid valves (from here forth valves ), signals from auto switches, etc. Fieldbus Master unit EX260 + Valve manifold (Plug-in type) PLC*1 Power supply/ CPU Communication cable Input unit*1 Fieldbus network Auto switch Parallel wiring PLC*1 Output card Input card Power supply/ CPU Valve manifold (Plug lead type) Junction terminal block*1 Multi-core cable*1 Junction terminal block*1 Auto switch A 1 *1 Commercially available

Advantages of Using a Fieldbus Reduced wiring labor and required wiring space Valves can be successfully controlled by connecting the PLC and valve manifold with a single cable. The combining of multiple cables into a single cable supports equipment downsizing and simplification. When wiring the lead wire to the terminal of a D-sub connector, etc., there s no need to check pin arrangements or perform any other time-consuming tasks. Improvement of maintenance workability Reduced wiring labor allows for the easy replacement of faulty units, cables, etc., leading to reduced maintenance labor as well. Increased flexibility when increasing the number of I/O points Even when increasing the number of I/O points, there is no need for an additional PLC input/output card. Error diagnostic function Error diagnosis is possible. The error contents can be checked not only on the touch panel (PLC) but also on the product s LED display screen. When a problem occurs, a local diagnosis can provide even more detailed information. Main control panel Error contents that can be displayed on the LED screen Network state state Power supply state The disconnection/short-circuit of input devices (auto switches, etc.) and output devices (valves, etc.) Local diagnosis 1 Green ON Normal Red ON Short circuit Red flashing Open circuit *1 Display of the EX600 series For details, refer to page 94 and onwards. Comprehending the number of times the device used by the equipment has been operated By using the counter function*1, it is possible to measure the number of times an auto switch, valve, etc., has been turned ON and OFF. This allows for the easy prediction of when maintenance should be carried out and the easy identification of which areas are in need of maintenance. Preventive maintenance and the advanced preparation of error countermeasures will allow you to reduce the amount of time the equipment will need to be out of service. 2,000 cycles 100,000 cycles Replacement! 500 cycles *1 Function of the EX600 series For details, refer to page 94 and onwards. (When the counter reaches the pre-determined number, the LED display will flash in red.) 2

Advantages of the Fieldbus Compatible Valve Manifold (with SI Unit) The is a product that makes use of the Fieldbus to control valve manifolds, etc. When using an to control valves As the Fieldbus interface () is linked with the valve manifolds, an output unit is not necessary. Also, there is no need to prepare multi-core cables (D-sub connector, MIL connector, multi-connector) and branch connectors separately. Fieldbus network M12 connector cable No output unit is necessary. Reduction of installation space Since an output unit is not necessary, the space required for installation can be greatly reduced. <Example: EX260 series> Approx. 77 mm Approx. 103 mm Approx. 28 mm Reduced product selection/ordering labor Valve manifolds and s can be ordered together. The required cables, connectors, accessories, etc., can also be ordered together. For details on cables, connectors, and other types of accessories, refer to page 216 and onwards. Valve manifold + Communication cable Power supply cable 3

When using a Fieldbus compatible output unit to control valves Fieldbus compatible output unit*1 Fieldbus network Multi-core cable*1 Valve manifold Branch connector*1 *1 Commercially available Now with an improved enclosure: IP65/67 M12 connector type products Enclosure: IP65/67 D-sub connector type products Enclosure: IP40 The product does not need to be stored in a waterproof case, and it can be installed even in locations where water splashing occurs. The enclosure may differ according to the Fieldbus. For details, refer to pages 13 and 14. Please confirm the enclosure of the valves as well. For details, refer to each individual product of the EX series. Output unit*1 Valve manifold *1 Commercially available 4 A

Product Series Featuring 3 Types Suitable to a Variety of Equipment/Facility Layouts Type 1 Output type for solenoid valves When decentralized arrangement of valve manifolds is desired When installing valve manifolds close to the cylinder/actuator due to minimal space Number of inputs/outputs: Small (Example: EX260 series [32 outputs]) Applicable products EX260 EX123 EX124 EX126 EX120 EX121 EX122 EX140 EX180 PLC Fieldbus network Power supply Supply air Input unit Valve 5

For selection, refer to pages 13 and 14. Features Number of nodes Wiring Piping Actuator responsiveness Address setting Digital input Analog input/output Change of protocol Effectiveness and Compatibility It s easy to install into equipment with a small number of I/O points, and it s possible to break up valve manifolds and input units. Increases according to the number of valve manifolds and input units Valve manifolds can be installed in the vicinity of an actuator. a Reduced wiring space It is necessary to provide both a communication cable and a power cable. Valve manifolds can be installed in the vicinity of an actuator. a Reduced piping space Reduced piping space a Increased actuator responsiveness due to shorter piping tubes Address setting is required for each individual and input unit. Using an input unit not manufactured by SMC Using a unit not manufactured by SMC All units must be replaced. Input unit Valve 6

Product Series Featuring 3 Types Suitable to a Variety of Equipment/Facility Layouts Type 2 Gateway type When the use of a GW unit is desired to further reduce the wiring of valve manifolds and input units Number of inputs/outputs: Medium (Example: EX500 series [128 outputs]) Applicable products EX500 PLC Fieldbus network Power supply Supply air GW SMC s dedicated communications network Valve Valve Input unit Input unit 7

For selection, refer to pages 13 and 14. Features Number of nodes Wiring Piping Actuator responsiveness Address setting Digital input Analog input/output Change of protocol Effectiveness and Compatibility It is possible to break up a large number of valve manifolds and input units for installation with the use of a GW unit. With 1 node of a GW unit, a large number of valve manifolds and input units can be used. Therefore, it is possible to reduce the number of nodes. Valve manifolds can be installed in the vicinity of an actuator. a Reduced wiring space A single cable can be used in place of a separate power cable and communication cable (for between the GW unit and the valve manifolds/input units). Valve manifolds can be installed in the vicinity of an actuator. a Reduced piping space Reduced piping space a Increased actuator responsiveness due to shorter piping tubes By conducting the address setting of the GW unit, there is no need to do so for the s, input units, etc. This makes plug and play possible. SMC s input units can be used. Using a unit not manufactured by SMC It is possible to make changes by simply replacing the GW unit. unit Valve Valve Input unit Input unit 8

Product Series Featuring 3 Types Suitable to a Variety of Equipment/Facility Layouts Type 3 Integrated input-output type When valve manifolds, input units, etc., are desired to be installed in the same place When there is sufficient wiring/piping installation space between the valve manifolds and the actuator Number of inputs/outputs: Large (Example: EX600 series [512 outputs]) Applicable products EX600 EX245 EX250 PLC Fieldbus network Supply air Power supply Output unit Input unit 9

For selection, refer to page 13. Effectiveness and Compatibility Features Number of nodes Wiring Piping Actuator responsiveness Address setting Digital input Analog input/output Change of protocol Valve manifolds, input units, etc., can be controlled together. While the number of nodes is increased according to the number of valve manifolds, the number of nodes can be reduced by linking with an input-output unit. When cables are concentrated in a single area, it s common for the wiring space between the valve manifolds and the actuator to get increasingly complex. It is necessary to provide both a communication cable and power cable. When tubes are concentrated in a single area, it s common for the piping space between the valve manifolds and the actuator to get increasingly complex. When the piping tubes are too long, it s common for the actuator s responsiveness to decline. Address setting for each individual is necessary. SMC s input units can be used. SMC s units can be used. It is possible to make changes by simply replacing the. Input unit Valve manifold 10

Latest Fieldbus System Technology Ring type PLC Ring supervisor 1 Switching hub is not required. EtherNet/IP /PROFINET Cable length can be shortened. q w e r 1 When using EtherNet/IP One or more ring supervisors are required. Even if a communication cable is disconnected or damaged at any location, communication can be continued. EtherNet/IP : DLR (Device Level Ring) PROFINET: MRP (Media Redundancy Protocol) With a ring supervisor, the cable segment that is causing the problem can be identified. PLC PLC Ring supervisor Ring supervisor Disconnected location q w e r q w e r Normal flow of data Data flow when the communication cable is disconnected Also applicable for other topologies (connection configuration) Star type Linear type PLC PLC Switching hub is not required. EtherNet/IP /PROFINET Switching hub EtherNet/IP / PROFINET Cable length can be shortened. q w e r q w e r 11

For applicable products, refer to Specifications for each product of the EX series. QuickConnect function (EtherNet/IP, DeviceNet ), Fast Start Up function (PROFINET) For the QuickConnect function, time from power ON to communication connection Approx. 10 sec. Times may vary according to model and system construction. For details, consult with SMC. Approx. 0.5 sec. In the case of a tool changer, it takes about 10 seconds for communication to be connected in some products after the power to the device installed on the tool is turned ON. For products which support the QuickConnect or the Fast Start Up function, communication can be operational even faster. Save time when connecting and improve productivity In order to use the QuickConnect or the Fast Start Up function, the PLC must be able to support the QuickConnect or the Fast Start Up function. Tool 2 Tool 3 Robot arm Tool 1 Example of use Web server function Status checks, parameter settings, and forced output are possible with the use of general-purpose web browsers such as Internet Explorer. This allows for efficient system start-up and maintenance. PLC EtherNet/IP EX q to e can be accessed via a web browser. Switching hub EX q EX w EX e Status check Parameter setting Forced output, etc. Connection example 12

Applicable Product Selection by Type IP67/65 specification models Type 1 Output type for solenoid valves Type 2 Gateway type Type 3 Integrated input-output type Number of valve outputs 32 16 EX260 EX124 Number of inputs 16 32 EX123*1, EX126*1 EX500 EX600 EX245 EX250 p. 24 p. 48 p. 54 p. 94 p. 134 p. 146 Applicable valve series Applicable protocols EtherNet/IP PROFINET Modbus TCP Ethernet POWERLINK EtherCAT CC-Link IE Field PROFIBUS DP DeviceNet CC-Link AS-Interface CANopen CompoNet INTERBUS IO-Link Series EX260 EX124 EX500 EX600 EX245 EX250 SY 3000 (Plug-in connector connecting 5000 base: 10/11/12 type) 7000 S0700 (Stacking base) 0700 1000 2000 SV 3000 4000 1000 2000 VQC 4000 5000 1000 2000 VQ 4000 5000 : Standard product : Made to order 1 For details, refer to the catalog of each product. 13

IP20 specification models Type 1 Output type for solenoid valves Type 2 Gateway type Type 3 Integrated input-output type Number of valve outputs Number of inputs 32 16 16 32 EX180 EX120 EX121 EX122 EX140 p. 172 p. 180 p. 184 Applicable valve series Applicable protocols EtherNet/IP TM PROFINET Modbus TCP Ethernet POWERLINK EtherCAT CC-Link IE Field PROFIBUS DP DeviceNet TM CC-Link AS-Interface CANopen CompoNet TM INTERBUS IO-Link Series EX120 EX121 EX122 EX140 EX180 (Plug-in connector 3000 connecting base: 5000 10/11/12 type) 7000 SY 3000 (Plug-in metal base: 50/51/52 type) 5000 7000 2000 SJ 3000 S0700 (Bar stock) 0700 3000 (Bar stock: 42SA type) 5000 SY (Stacking base: 45S6/43SA type) SV VQ 7000 3000 5000 7000 9000 1000 2000 3000 4000 1000 2000 4000 5000 SQ 1000 2000 SZ 3000 VQZ SYJ 1000 2000 3000 3000 5000 7000 : Standard product : Made to order 1 For details, refer to the catalog of each product. 14

Reduced-wiring Fieldbus System (Serial Transmission) Applicable Valve Series q SJ2000/3000 Series Plug-in Type EX180 p. 184 SJ2000/3000 Connector connecting cassette type manifold Pneumatics No. 1-1. SY3000/5000/7000 Series Plug-in Type Connector connecting base Side ported/bottom ported/ Top ported EX120 p. 172 Connector connecting base Side ported/bottom ported/ Pneumatics No. 1-1. Top ported EX126 p. 48 Connector connecting base Side ported/bottom ported/ Top ported EX260 p. 24 Connector connecting base Side ported/bottom ported/ Top ported EX245 p. 134 EX250 p. 146 EX600 p. 94 Gateway Decentralized System 2 (128 Points) EX500 p. 54 Gateway Decentralized System (64 Points) EX500 p. 54 15 SY3000/5000/7000 Catalog. Connector connecting base Side ported/bottom ported/ Top ported Connector connecting base Side ported/bottom ported/ Top ported Connector connecting base Side ported/bottom ported/ Pneumatics No. 1-1. Top ported Connector connecting base Side ported/bottom ported/ Top ported Metal base Side ported/bottom ported/ Top ported

Reduced-wiring Fieldbus System (Serial Transmission) Applicable Valve Series w SY3000/5000/7000/9000 Series Plug-in Type Stacking type separate type EX121 p. 172 EX122 p. 172 SY3000/5000 Stacking type integrated type Pneumatics No. 1-1. Stacking type Non Plug-in Type (Plug Lead Type) EB P SY3000/5000/7000 Body ported/base mounted Bar stock type SY3000/5000 Stacking type SY9000 Body ported/base mounted Stacking type PE EB EA X EA P Pneumatics No. 1-1. S0700 Series Plug-in Type EX260 p. 24 Pneumatics No. 1-1. EX250 p. 146 EX245 Catalog. p. 134 EX600 S0700 p. 94 Gateway Decentralized System 2 (128 Points) EX500 p. 54 Pneumatics No. 1-1. Gateway Decentralized System (64 Points) EX500 p. 54 16

Reduced-wiring Fieldbus System (Serial Transmission) Applicable Valve Series e S0700 Series Non Plug-in Type (Plug Lead Type) S0700 Pneumatics No. 1-1. Slim Compact (Plug-in Type) EX180 p. 184 S0700 Pneumatics No. 1-1. SV1000/2000/3000/4000 Series Plug-in Type EX120 p. 172 SV1000/2000 Connector type manifold Cassette base SV1000/2000/ 3000/4000 Connector type manifold Tie-rod base Pneumatics No. 1-2. EX126 p. 48 EX260 p. 24 EX245 Catalog. p. 134 EX250 SV1000/2000/3000 Connector type manifold Tie-rod base p. 146 EX600 p. 94 Pneumatics No. 1-2. Gateway Decentralized System 2 (128 Points) EX500 p. 54 Gateway Decentralized System (64 Points) SV1000/2000 EX500 Connector type manifold Cassette base SV1000/2000/ 3000/4000 Connector type manifold Tie-rod base p. 54 17

Reduced-wiring Fieldbus System (Serial Transmission) Applicable Valve Series r SYJ3000/5000/7000 Series Non Plug-in Type (Plug Lead Type) SYJ3000/5000/7000 Body ported Pneumatics No. 1-2. SZ Series Plug-in Type EX140 p. 180 SZ3000 Cassette type manifold Pneumatics No. 1-2. VQ Series Plug-in Type EX120 p. 172 VQ1000/2000 EX123 EX124 p. 48 VQ2000/4000/5000 IP65-compliant Pneumatics No. 1-2. VQ1000/2000 18

Reduced-wiring Fieldbus System (Serial Transmission) Applicable Valve Series t VQC Series Plug-in Type EX126 p. 48 Best Pneumatics No. 1-2 EX260 p. 24 EX245 Catalog. p. 134 EX250 p. 146 VQC 1000/2000/ 4000/5000 EX600 p. 94 Best Pneumatics No. 1-2 Gateway Decentralized System 2 (128 Points) EX500 p. 54 Gateway Decentralized System (64 Points) EX500 p. 54 VQZ Series Non Plug-in Type (Plug Lead Type) VQZ 1000/2000/ 3000 Body ported Pneumatics No. 1-2. SQ Series Plug-in Type EX140 p. 180 SQ1000/2000 19 Body ported Best Pneumatics No. 1-2