CEW SERIES CEILING EXPOSED HORIZONTL FN COIL UNITS MGIC IRE BMW SERIES FN COILS RE ETLC LISTED IN CCORDNCE WITH UL 1995 ND RE SSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPNY, L.P. 501 Galveston St. Wichita Falls, Texas 76301 940-397-20 Fax 940-397-2166 CEW- 1.2 www. magicaire.com PI 06/01 6M Page 1 CEW- 1.2
CEW MODEL Decorative, slim cabinet designed for exposed ceiling applications. Unit includes double deflection discharge grille. Cabinet is galvanealed steel with baked powder Polar Ice color coating for the ultimate in durability. ll panels are lined with acoustic and thermal glass fiber insulation. Filters are one inch throwaway and are accessed through the hinged bottom service panel. Optional mixed air damper for 0% outside air requirements. 6 KNOCKOUTS FOR PIPING RER MOUNTING HOLES X 4 KNOCKOUTS FOR PIPING RER B OPTIONL O DUCT COLLR 3 2 FRONT SUPPLY IR R/O DMPER SECTION 8.5 TOP VIEW HINGED SERVICE CCESS PNEL FILTER O DUCT COLLR STMPED RETURN IR GRILLE B1 12 SUPPLY IR FRONT VIEW HINGED SERVICE CCESS PNEL STMPED RETURN IR GRILLE & 1 FILTER DIMENSIONS MODEL B B1 SHIPPING WEIGHT FILTER SIZE OPTIONL DISC. DUCT CONN. OPTIONL RER DUCT CONN. CEW 33" 36" 28" 2 x 18 x 1 6.75 x 15 8.5 x 18 CEW 33" 36" 28" 9 x 18 x 1 6.75 x 18 8.5 x 18 CEW 42" 36" 28" 147 x 27 x 1 6.75 x 27 8.5 x 36 CEW 51" 36" 28" 155 x 36 x 1 6.75 x 36 8.5 x 36 CEW 60" 36" 28" 171 x 45 x 1 6.75 x 45 8.5 x 45 CEW 69" 36" 28" 225 x 54 x 1 6.75 x 54 8.5 x 54 LL COIL CONNECTIONS 5/8" O.D. SWT. LL DRIN CONNECTIONS 3/4" M.P.T. Page 2 CEW- 1.2
CE*- Series Electrical Data Model # Motor FL KW Heat @ 120 VC KW Heat @ 208 VC KW Heat @ 240 VC Miniumum Circuit mpacity @ 120 VC Maximum Fuse Size @ 120 VC Miniumum Circuit mpacity @ 208 VC Maximum Fuse Size @ 208VC Miniumum Circuit mpacity @ 240 VC Maximum Fuse Size @ 240VC CE* 0.50 0 0 0 0. 5 15 CE* *-1.5E 0.50 1. 5 0 0 16. 1 20 CE* *-2.0E 0.50 2.00 0 0 21. 3 25 CE* *-2.5E 0.50 2. 5 0 0 26. 5 30 CE* 1. 1 0 0 0 1. 1 15 CE* *-1.5E 1. 1 1. 5 0 0 16. 7 20 CE* *-2.0E 1. 1 2.00 0 0 21. 9 25 CE* *-2.5E 1. 1 2. 5 0 0 27. 1 30 CE* *-3E 0. 5 0 2.25 3 CE* *-4E 0. 5 0 3.00 4 CE* *-5E 0. 5 0 3.75 5 14. 2 20 16. 3 20 18. 7 25 21. 5 25 23. 2 30 26. 7 30 CE* 1. 4 0 0 0 1. 8 15 CE* *-3E 0. 6 0 2.25 3 CE* *-4E 0. 6 0 3.00 4 CE* *-5E 0. 6 0 3.75 5 CE* *-6E 0. 6 0 4. 5 6 CE* *-8E 0. 6 0 6.00 8 14. 3 20 16. 4 20 18. 8 25 21. 6 25 23. 3 30 26. 8 30 27. 8 35 32. 0 35 36. 9 45 42. 4 45 CE* 1. 0 0 0 0 1. 0 15 CE* *-3E 0. 8 0 2.25 3 CE* *-4E 0. 8 0 3.00 4 CE* *-5E 0. 8 0 3.75 5 CE* *-6E 0. 8 0 4.50 6 CE* *-8E 0. 8 0 6.00 8 CE* *-E 0. 8 0 7.50 14. 5 20 16. 6 20 19. 1 25 21. 8 25 23. 6 30 27. 0 30 28. 1 35 32. 3 35 37. 1 45 42. 7 45 46. 1 60 53. 1 60 CE* 1. 0 0 0 0 1. 1 15 CE* *-3E 0. 9 0 2.25 3 CE* *-4E 0. 9 0 3.00 4 CE* *-5E 0. 9 0 3.75 5 CE* *-6E 0. 9 0 4.50 6 CE* *-8E 0. 9 0 6.00 8 CE* *-E 0. 9 0 7.50 14. 7 20 16. 8 20 19. 2 25 22. 0 25 23. 7 30 27. 2 30 28. 2 35 32. 4 35 37. 2 45 42. 8 45 46. 3 60 53. 2 60 CE* 1. 5 0 0 0 1. 5 15 CE* *-6E 1. 2 0 4.50 6 CE* *-8E 1. 2 0 6.00 8 CE* *-E 1. 2 0 7.50 28. 6 35 32. 8 35 37. 6 45 43. 2 45 46. 6 60 53. 6 60 Page 3 CEW- 1.2
MODEL CEW Blower Performance with 3 Row Coil CFM VS EXTERNL STTIC PRESSURES (DRY COIL DT SHOWN) 0. 0.15 0.20 0.25 0.30 265 235 2 165 125 4 380 350 3 260 595 550 500 430 350 840 785 730 665 575 905 840 750 675 580 1190 10 00 860 700 MODEL CEW Blower Performance with 4 Row Coil CFM VS EXTERNL STTIC PRESSURES (DRY COIL DT SHOWN) 0. 0.15 0.20 0.25 0.30 255 225 190 155 120 385 360 325 280 235 565 530 460 395 320 800 745 680 6 535 850 785 705 635 550 1130 60 920 790 640 CEW Blower Performance with 5 Row Coil MODEL CFM VS EXTERNL STTIC PRESSURES (DRY COIL DT SHOWN) 0. 0.15 0.20 0.25 0.30 240 2 180 150 1 370 335 300 260 220 530 480 425 355 300 750 700 630 565 500 800 735 660 600 5 60 960 850 7 600 BLOWER CORRECTION FCTOR MED LOW. 90.80. 90.80. 95.91. 95.91. 90.80. 95.91 To get airflow data at medium and low speeds, multiply blower performance by correction factor. Page 4 CEW- 1.2
CEW-3 Coil Capacities LWT LWT LWT -CEW-3 -CEW-3 -CEW-3 -CEW-3 -CEW-3 -CEW-3 Page 5 CEW- 1.2
CEW-4 Coil Capacities LWT LWT LWT -CEW-4 -CEW-4 -CEW-4 -CEW-4 -CEW-4 -CEW-4 Page 6 CEW- 1.2
1 Row Heating 2 Row Heating -CEW-1HW -CEW-2HW -CEW-1HW -CEW-2HW -CEW-1HW -CEW-2HW -CEW-1HW -CEW-2HW -CEW-1HW -CEW-2HW -CEW-1HW -CEW-2HW Page 7 CEW- 1.2
3 ROW HETING -CEW-3 -CEW-3 -CEW-3 -CEW-3 -CEW-3 -CEW-3 Entering ir Temp (F) HOT WTER HETING CORRECTION FCTORS Entering Water Temp (F) o o 0 1 120 o 130 o 140 o o o o 150 160 170 80 50 o. 419. 838. 917 1.000 1.090 55 o. 376. 460. 544. 629. 708. 791. 873. 963 1.048 60 o. 335. 419. 838. 917 1.000 65 o. 290. 376. 460. 544. 629. 708. 791. 873.963 70 o. 251. 335. 419. 838.917 75 o. 205. 290. 376. 460. 544. 629. 708. 791.873 80 o. 167. 251. 335. 419.838 1 o Page 8 CEW- 1.2
4 ROW HETING -CEW-4 -CEW-4 -CEW-4 -CEW-4 -CEW-4 -CEW-4 Entering ir Temp (F) HOT WTER HETING CORRECTION FCTORS Entering Water Temp (F) o o 0 1 120 o 130 o 140 o 150 o 160 o 170 o 80 50 o. 419. 838. 917 1.000 1.090 55 o. 376. 460. 544. 629. 708. 791. 873. 963 1.048 60 o. 335. 419. 838. 917 1.000 65 o. 290. 376. 460. 544. 629. 708. 791. 873.963 70 o. 251. 335. 419. 838.917 75 o. 205. 290. 376. 460. 544. 629. 708. 791.873 80 o. 167. 251. 335. 419.838 1 o Page 9 CEW- 1.2
Model Size CEILING EXPOSED HORIZONTL FN COILS CEW 3 & 4 ROW CHILLED WTER COOLING WITH OPTIONL ELECTRIC OR HOT WTER HET S ERIES DESIGNTION ELECTRIC HET DDERS (KV)* s standard equipment all CEW series units are equipped with 3 speed Direct Drive 115v single phase motor. ll CEW series units with electric heat are equipped with contactor for 115v control (24v is available). 1.5 2.5 kw electric heaters are 120v. ll other electric heaters are 208-230v. Coil options are 3, 4, 3/1 split, 4/1 split, 1/3 split, 2/3 split, 1/4 split and 5 row (maximum). Split coils are for four pipe systems. Use 4/1 split for 5 row coil pricing. Consult Piping & Control Packages brochure for all factory selected thermostat and valve cluster combinations. See Control Pricing & Coding and Valve Pricing Clusters & Components for pricing of same. CEW OPTIONS (Contact factory for availability) HOT WTER HET DDERS CEW-3 CEW-4 1.5-2. 5 3-5 6-8 1 ROW 2 ROW N N N N N N N N N N N OPTIONS 220v/1 50Hz motor MODEL NUMBER -CE -CE -CE -CE -CE -CE WIRING DIGRM CEW SERIES DUL MOTOR ON MODEL ONLY BLCK BLUE RED H M FN C WHITE MOTOR L CONNECT TO N PPROPRITE LINE VOLTGE THERMOSTT ND FN SWITCH BLCK H BLUE M FN C WHITE MOTOR RED L L1 N BLCK WHITE Page CEW- 1.2
VLVE COMPONENTS WTER (2-WY) R COIL S WTER (3-WY) R FOR CEW FN COIL UNITS SERIES B C B C B C SERVICE VLVES CONTROL VLVES FLOW CONTROL (NOT BOTH T SME TIME) COMPONENTS BLL VLVES (BLNCE VL) GTE VLVES 2-WY MOTORIZED 3-WY MOTORIZED BLL VLVE W/ MEMORY STOP -OR- CIRCUIT SETTER (3 WEEKS) VOLTS SIZE 1/2 3/4 1/2 3/4 24 1/ 2 115 1/ 2 24 3/ 4 115 3/ 4 24 1/ 2 115 1/ 2 24 3/ 4 115 3/ 4 1/2 3/4 1/2 3/4 COIL S 1. VLVE SIZE: 5/8 (1/2) OR 7/8 (3/4). 2. CONTROL VOLTGE (24, 115). 3. 2-WY OR 3-WY MOTORIZED VLVES, TWO-POSITION, SPRING RETURN, NORMLLY CLOSED CONTROL VLVES WITH MNUL OPENING LEVER. CEW COIL CONNECTION DIMENSIONS LEFT HND COOLING (Heating opposite side) SHOWN (Right hand is mirror image) C B 3.688 3-1, 4-1, 3-2 Split Coil 3.688 E 1-3, 1-4, 3-2, 3-1, 4-1, 2-3 Split Coil 1.750 R 4.125 4.125 R 1.750 S R S R 2.250 S S 2.250 S SUPPLY R RETURN CHILLED WTER HOT WTER UNIT B C E --CHW-3-5.438 --CHW-4-6.313 --CHW-5-7.188 --CHW-31-4.500 6.250 --CHW-41-4.500 7.125 --CHW-32-5.375 7.125 --CHW-13-6.313 --CHW-14-7.188 --CHW-23-7.188 Page 11 CEW- 1.2
ENGINEERING SPECIFICTIONS Cabinets shall be fabricated of LFQ (min) steel. External parts are to be made with a polyurethane based powder coated 60 galvanealed, while internal parts are to be built from G90 galvanized steel. Units shall pass 500 hour salt spray test as described in STM B-117. Coils are to be tested at 500 PSI for operation at 400 PSI guage. ll water coils have air vents. Fan wheel bearings shall be self aligning, sealed cartridge, permanently lubricated ball bearings that provide dependable fan operation for an average life of 200,000 hours (belt drive only) Variable pitch motor sheaves. United Electric Company designs and builds its Magic ire products to comply and perform to one or more of the following standards: COIL IR FLOW CPCITY General Belt Drive Equipment Direct Drive Equipment Hydronic Direct Expansion MC 2 SHRE 51 RI 430 RI 440 RI 4 RI 2 IN DUCT SOUND RTINGS ir Moving Equipment SHRE 68 MC 330 SFETY MTERIL GENCY LISTINGS SPECIFICTIONS MJOR COMPONENTS Coils UL Report # Equipment ETL Report # Sheet Metal Copper Tubing luminum Motors Wire Electrical Filters Fiberglass Paint UL 207 S 3438 CCS C22.2 #236 NSI/UL-1995 491893 STM 525 STM 527 STM B68 STM B75 STM B88 STM B251 STM B209 UL/CS NEM UL/CS UL/CS UL SHRE 52 UL 181 UL 723 (25/50) STM E-84 STM B117 UNITED ELECTRIC COMPNY, L.P. 501 Galveston St. Wichita Falls, Texas 76301 940-397-20 Fax 940-397-2166 CEW- 1.2 www. magicaire.com PI 06/01 6M Page 12 CEW- 1.2