DIN RAIL FIBER ENCLOSURE

Similar documents
Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

NEMA-Rated Fiber Optic Wallmount Enclosure. Protects your fiber cabling in a damp environment.

8400 Series Fiber Distribution System

BLACK BOX. Fully assembled, ready-to-use wallmount cabinets. Elite Wallmount Cabinet User s Manual. Customer Support Information

FIBER CONNECTOR SAFETY WARNINGS

Fiber Connector Shelf (CCS)

MKVI Jetta Fog Light Kit

INSTALLATION INSTRUCTIONS

Instructions for Use - Opt-X 1000i Enclosure

1 Part Number: Part Description: Mustang GT-Shelby Style Electric Exhaust Valve Wiring Installation Instructions

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

Low-profile, 11U high cabinets hold networking

INSTALLATION MANUAL AP60B INSTALLATION MANUAL

Reverse Camera Installation Instructions

MKVI Jetta Fog Light Kit

Magna Track Magnetic Mounting System for ECEX Air Intake Screens. Features / Benefits

Fully assembled, ready-to-use custom cabinets.

S/6EA CARRIAGE & ELECTRICAL INSTALLATION INSTRUCTIONS PART VI CARRIAGE ASSEMBLY ELECTRICAL WIRING PART III THE FESTOON RACKING ELECTRICAL HOOK-UPS

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

The economical 42U cabinet that s easy to transport and assemble on-site.

Upgrading the Sure Coat Modular Gun Control System

GENUINE PARTS INSTALLATION INSTRUCTIONS

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

COYOTE LCC (Low Count Closure)

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE AV7900 Dual Multimedia Headrest Replacement System

INSTALLATION GUIDE. AV8900H Dual Multimedia Headrest Replacement System

INSTALLATION GUIDE Car Show Dual DVD Headrest Replacement System

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Opticom Rack Mount Fiber Enclosures

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

Fiber Splice Panel Rack Mount User Manual

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

3D PRINTER. Pack 10. Anything you can imagine, you can make! 3D technology is now available for you at home! BUILD YOUR OWN

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Environmental Distribution Center (EDC-06P-NH)

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

INSTALLATION INSTRUCTIONS

Previa (RHD) - MMC PZ425-R PART NUMBER INSTALLATION INSTRUCTIONS TOYOTA NAVIGATION SYSTEM. (Production date 05/03)

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

McDonalds Installation Guide

Universal Splice Tray Installation Instructions

Prusa i3 Printer Assembly Guide

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

User and Fitting Manual June 2008

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Installation MKIV Headlight Housings with Fog Lamps (Procedures apply to both MKIV Jetta and Golf)

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

UNSIGNED HARDCOPY NOT CONTROLLED

READ ME! IMPORTANT WARNING! ENG. Auxiliary 80l Fuel Tank Toyota Hilux DC 2005-Current

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

GENUINE PARTS INSTALLATION INSTRUCTIONS

SCION tc 2014 FOG LIGHT KIT

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Fiber optic splice closure

1000 Park Drive Lawrence, PA Fax

INSTALLATION INSTRUCTIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

INSTALLATION INSTRUCTIONS

Corolla TNS600. RHD installation instructions. Model year: 2004 Vehicle code: **E12*R-****W

Supply Valve Replacement

PanView iq (PViQ) Fiber Tray

Hiace TNS600. LHD installation instructions. Model year: 2006 Vehicle code: KLH**L-**M**W

NUFORS-DC VALVE SERVICE

Installation Instructions Table of Contents

ASX / OUTLANDER SPORT / RVR REAR VIEW CAMERA MZ380552EX INSTALLATION AND HANDLING INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions for V&P Heat Block, Magnetic Tumble Stirrer and Table On a Tecan Liquid Handler. Magnetic Tumble Stirrer VP 710T-SM

CHEMINSTRUMENTS HOT ROLL LAMINATOR MODEL HL-100, HL-101 OPERATING INSTRUCTIONS

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

* * APPLICABLE MODELS: 2014 > Mazda 3

Toyota Prius Dual Player Headrest Video ATTENTION: SECURITY COVERS ARE NO LONGER INCLUDED IN THE HEADREST KITS AS OF 01/17/2011

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

SCION TC HANDS FREE BLU LOGIC Preparation

General Applicability Note: Recommended Tools. Personal & Vehicle Protection Safety Goggles Seat Covers Floor Covers Special Tools. Installation Tools

Lionel Hot Box Car Mini Commander Installation Guide

INDUS rail /

FORWARD-FACING USER MANUAL ECE R44 04 GROUP. WEIGHT 9-18 kg. AGE 9m-4y

* * APPLICABLE MODELS: 2014 > Mazda 6

SERVICE BULLETIN B. Tools Required: 7/32 & 1/8 Allen wrench Needle Nose Pliers 9/16 & 1/2 Sockets Adjustable Wrench

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

MY F150 CrewCab 1. Tools Required E F G. Page 1 of 10 9L3J-19A014-AA Copyright Ford 2013 FoMoCo

Desktop 5.5 Z Axis Retrofit

OIL COOLER KIT INSTALLATION INSTRUCTIONS PART NUMBER D

Fitting Instructions ECE. type-approved. 1 Component overview 2 Warnings 3 Assembling 4 Light bulb replacement. Info:

Snap Sampler Deployment Guide

Metal & Cable Corp., Inc.

* * APPLICABLE MODELS: 2017 > CX-5

Transcription:

USER MANUAL JPM397A, JPM398A DIN RAIL FIBER ENCLOSURE 24/7 AT OR VISIT BLACKBOX.COM

TABLE OF CONTENTS 1. SPECIFICATIONS... 3 2. OVERVIEW... 4 2.1 Description...4 2.2 What s Included...4 2.3 Part Numbers...4 3. PRE-INSTALLATION... 5 3.1 STEP 1: Enclosure Mounting...5 STEP 1A: Optional Mounting Solutions...6 3.2 STEP 2: Bulk Fiber Cable Entry...8 4. INSTALLATION... 10 4.1 STEP 1: Mounting the Enclosure to the DIN Rail...10 4.2 STEP 2: Cabling and Securing the Bulk Fiber to the Enclosure...10 4.3 STEP 3: Terminating the Fiber Cable... 11 2 BLACKBOX.COM

CHAPTER 1: SPECIFICATIONS TABLE 1. JPM398A SPECIFICATIONS SPECIFICATION Dimensions Weight Metal Thickness Color Cable Grommet Range Fiber Adapter Ports DESCRIPTION 2.01" H x 5.31" W x 5.51" D (5.1 x 13.5 x 14 cm) 1.15 lb. (0.52 kg) 18-gauge (1.0 mm) Black 4.0 mm to 8.0 mm One TABLE 2. JPM397A SPECIFICATIONS SPECIFICATION Dimensions Weight Metal Thickness Color Cable Grommet Range Fiber Adapter Ports DESCRIPTION 3.93" H x 5.31" W x 5.51" D (10.0 x 13.5 x 14 cm) 2.0 lb. (0.907 kg) 18-gauge (1.0 mm) Black 4.0 mm to 8.0 mm Two BLACKBOX.COM 3

CHAPTER 2: OVERVIEW 2.1 DESCRIPTION This inexpensive and very flexible DIN Rail Fiber Enclosure is an excellent choice when you need to run fiber terminations out on an open external wall or in an open manufacturing floor environment. The DIN Rail Fiber Enclosure is small and made of steel. It supports either one or two LGX fiber adapter panels with a side door that uses thumbscrews for easy access inside of the enclosure. There are also many DIN rail mounting options around the enclosure, along with three bulk fiber points of entry, when combined make this enclosure extremely flexible. 2.2 WHAT S INCLUDED Your package should include the following items for either the 1 or 2 port DIN Rail Fiber enclosure. If anything is missing or damaged, contact Black Box Technical Support at 877-877-2269 or info @blackbox.com. (1) DIN Rail Fiber Enclosure (4) 1 x ½ stick-on cable organizers (5) 4-inch cable ties (10) 3-inch cable ties (1) L -shaped rackmount bracket 4 BLACKBOX.COM

CHAPTER 3: PRE-INSTALLATION The pre-installation steps can be used for both the 1 and 2 ports DIN Rail enclosures. For illustration, we are only showing the 1 port DIN Rail enclosure. 3.1 STEP 1: ENCLOSURE MOUNTING First, determine where you wish to mount the enclosure. The DIN Rail Fiber Enclosures have several possible DIN rail mounting options that the user can select. From the factory, the DIN rail bracket is located on the rear of the enclosure (see photo). (2) screws on the DIN rail mounting plate FIGURE 3-1. DIN RAIL BRACKET ON THE ENCLOSURE But, to mount the DIN Rail Fiber Enclosure in alternate locations, remove the screws on the DIN Rail mount plate and relocate it to the new location. The alternate other mounting locations are on the top and bottom of the enclosure near the thumbscrews of the door plate and the back side of the enclosure. BLACKBOX.COM 5

CHAPTER 3: PRE-INSTALLATION Back side mounting locations Top and bottom mounting locations FIGURE 3-2. TOP AND BOTTOM AND BACK SIDE MOUNTING LOCATIONS STEP 1A: OPTIONAL MOUNTING SOLUTIONS The DIN Rail Fiber Enclosure has several other optional mounting solutions. There is an optional Magnetic Bracket (sold separately, part number ACC-MAGBRKT) and an L shaped Adapter bracket (included with the DIN Rail Enclosure) that can be used for the other non-din rail mounting installations. (See Photo below) These optional mounting solutions are supported on either the one or two port Din Rail Fiber Enclosure. part number ACC-MAGBRKT included FIGURE 3-3. OPTIONAL MAGNETIC BRACKET AND L -SHAPED BRACKET 6 BLACKBOX.COM

CHAPTER 3: PRE-INSTALLATION To use either one of these optional mounting solutions on your DIN Rail Fiber Enclosure, remove the green DIN Rail bracket from the fiber enclosure. Choose either the magnetic bracket or the L shaped bracket for your application. The Magnetic Bracket can be installed at the following locations on the DIN Rail Fiber Enclosure. Four screws must be used to property mount the magnetic bracket to the enclosure. One Port Enclosure Only on the side for flush mounting Two Port Enclosure On the side for flush mounting and the rear side opposite the fiber ports NOTE: The magnet bracket adapter uses four high-power rare earth magnets with a rubber coated base. These four magnets together have tremendous holding power and should be used on metal surfaces where you may want to mount your DIN Rail Fiber Enclosure. CAUTION: Always use care when handling. Follow the precautions listed below. Always wear safety goggles when handling large magnets. Always wear gloves when handling magnets to prevent pinching. Children should NEVER be allowed to play with Neodymium magnets. WARNING: Keep magnets at least 7.9 inches (20 cm) away from devices such as sensitive electronic and storage devices, mechanical watches, heart pacemakers, CRT monitors and televisions, credit cards, diskettes and other magnetically stored media such as video tapes. These devices are all affected by powerful magnets. FIGURE 3-4. APPLICATION #1, MAGNETIC BRACKET The L Shaped Adapter Bracket can be installed at the following locations on the DIN Rail Fiber Enclosure. Two screws are used for to correctly mount the L Shaped bracket to the enclosure. It has oversized cup head holes to allow the user some flexibility in mounting to a wide range of relay racks or cabinets. One Port Enclosure On the side for flush mounting and the rear side opposite the fiber ports Two Port Enclosure On all sides of the enclosure in various locations BLACKBOX.COM 7

CHAPTER 3: PRE-INSTALLATION NOTE: The L Shaped Adapter Bracket will not install on the top or bottom of the one-port enclosure. FIGURE 3-5. APPLICATION #2, L-SHAPED BRACKET 3.2 STEP 2: BULK FIBER CABLE ENTRY There are several points of entry where the incoming bulk fiber cable can enter the enclosure. From the factory, the point of entry is located at the bottom of the enclosure and the other access points are plugged. The bulk fiber cable is secured by a small angled bracket with a hand-tighten grommet and Kevlar clamp. If an alternate bulk fiber point of entry is desired, you can relocate the angled bracket to another available position. Bulk fiber entry Grommet nut Kevlar clamp Bulk fiber entry FIGURE 3-6. BULK FIBER CABLE ENTRY LOCATIONS 8 BLACKBOX.COM

CHAPTER 3: PRE-INSTALLATION To change the fiber point of entry: 1. Loosen the grommet nut and remove the angled bracket. 2. Find the new entry point and remove the plug cap and re-install the angled bracket. 3. Be sure to secure the angled bracket and re-install the plug cap in the previous location. NOTE: Make sure that you do steps 1 and 2 first. This will make your installation easier. BLACKBOX.COM 9

CHAPTER 4: INSTALLATION Now that you have made a DIN rail mounting and bulk fiber point of entry selection, you can begin to complete your installation. Completing the installation will require mounting the enclosure to the DIN rail, cabling and securing the bulk fiber cable to the enclosure, and making the fiber terminations. 4.1 STEP 1: MOUNTING THE ENCLOSURE TO THE DIN RAIL 1. Find a DIN rail bracket that is firmly secured to a wall. 2. Snap in the enclosure to the DIN rail on the wall until you hear a click (see photo). 3. Check that both green DIN rail brackets are locked and that the enclosure is firmly mounted. FIGURE 4-1. ENCLOSURE MOUNTING ON A DIN RAIL 4.2 STEP 2: CABLING AND SECURING THE BULK FIBER TO THE ENCLOSURE Now that the enclosure is firmly mounted to the wall, you can finish the installation. 1. Remove the two screws on the Kevlar clamp and remove the large grommet nut outside the enclosure. NOTE: Do this first (before you run bulk fiber cable in the enclosure). 2. Put the large grommet nut through the bulk fiber cable and feed the fiber cable end through the grommet on the enclosure. 3. Re-attach the large grommet nut to the grommet to firmly secure the fiber while you complete the installation. Make sure you feed enough fiber cable through the enclosure so you can terminate the fiber connectors. 4. Next, strip the cable jacket back close to the tip of the grommet end. Trim back the Kevlar yarn so just enough is available to firmly secure the Kevlar yarn to the clamp. 5. Attach the Kevlar yarn to the base and re-secure the 2 screws and tighten. This will hold the bulk fiber cable in the enclosure and will not put any stress on the fiber connection inside the enclosure. 6. Repeat for any other bulk fiber cable points of entry. 10 BLACKBOX.COM

CHAPTER 4: INSTALLATION Bulk fiber Big grommet nut Grommet end tip Kevlar yarn FIGURE 4-2. SECURING THE FIBER TO THE ENCLOSURE 4.3 STEP 3: TERMINATING THE FIBER CABLE Before you begin terminating the individual fiber strands, mount your fiber adapter panel to the front of the enclosure. The DIN Rail Fiber Enclosure accepts only LGX style fiber adapter panels. 1. Install your LGX fiber adapter panel. 2. Begin to individually terminate each fiber strand. Make sure that you provide enough slack inside the enclosure. This is usually done by providing a service loop. 3. Install and use the stick-on cable management organizers inside the enclosure to keep the fiber neat and manageable. 4. Terminate each fiber strand one at a time, dress the excess fiber with the stick-on cable organizers, and connect them to the inside of the fiber adapter panel. BLACKBOX.COM 11

CHAPTER 4: INSTALLATION FIGURE 4-3. FIBER CABLE TERMINATED 12 BLACKBOX.COM

NOTES \ BLACKBOX.COM 13

NOTES \ \ 14 BLACKBOX.COM

NOTES \ \ = BLACKBOX.COM 15

COPYRIGHT 2018. BLACK BOX CORPORATION. ALL RIGHTS RESERVED. JPM397A_JPM398A_USER_REV2.PDF