Mobile Diesel Heaters TOR / MIR Technical Training Course

Similar documents
Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

HVF110, 210, 310, 410HD

VAL6 KBE5S. Service Manual

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

Kerosene - oil burner

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

Light oil - kerosene burner

XL9 E-S Serial number N for XL9 E Edition 2005

HVF110, 210, 310, 410HD

Oil - kerosene burner

Trouble Shooting Guide EWA, 3-phase (D2422)

XL9E-S Edition2005. Serial numbern forxl9e

CODE MODEL TYPE PRESS GW 605 T80

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Installation and Maintenance Manual Please retain this manual for future reference.

SERVICE MANUAL (INTERNATIONAL)

AHE S - 12 VDC AHE X - 12 VDC AHE X - 12 VDC

Troubleshooting Manual

Modulating Furnace Information. Warning on Meter Setting - Read First!

Installation- and maintenance instruction B80-2/3

E Series CE Approved Intermittent Pilot Ignition Control

DIAGNOSIS AND TESTING

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Installation- and maintenance instruction BENTOFLEX ST 108 PL

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

Hayward error codes and troubleshooting

Installation- and maintenance instruction BENTOFLEX ST120KAV

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod

G600 Series Replacement Intermittent Pilot Ignition Controls

MAINTENANCE CHECKLIST & SCHEDULE FOR THE IDH RANGE

BLOWER VACUUM SWITCH FAILED OPEN

Installation- and maintenance instruction BENTOFLEX ST133KA/K

SECTION AIR INTAKE SYSTEM

Heating and Gas Installations - December 2014

MASTER DIRECT OIL HEATERS. MODEL 35 CED 10 kw Model ILLUSTRATED PARTS BREAKDOWN. Motor and Pump Assembly

RAYPAK ILLUSTRATED PARTS LIST

SER'IICING. CORlJAIR HEATER. the

Installation- and maintenance instruction ST120 S75/21

Installation- and maintenance instruction B20KAV/KV

RAYPAK ILLUSTRATED PARTS LIST

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

CREATIVE EQUIPMENT CC 18 Main Road, Fishers Hill, Germiston, 1401 Tel: Fax:

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B20K-2

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

ENGINE COOLING SYSTEM

KEY. Gas. Air. Aspiration. High Voltage. Low Voltage. Data. Light. BWB-1 Parts Interconnect. Mixing Chamber. Nebuliser. Ignitor. Pump.

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B45A2.2

13. FUEL SYSTEM/CARBURETOR/

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

TECHNICAL INFORMATION S2 Canister Vacuums

Fig Blast tube 2.Asbestos gasket 3.Flange 4.Body gasket 5. Brake plate. 6. Oil n ozzle 7.Heater 8.Rubber block 9. Transformer 10.

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

SERVICE MANUAL (INTERNATIONAL)

Installation- and maintenance instruction BENTOFLEX ST133K

Parts & Accessories INDEX

MODEL MC1500 Installation and Operation Manual Important:

Parts & Accessories INDEX

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

PARTS & SERVICE MANUAL

Heater Troubleshooting Guides

SPARE PARTS MANUAL VAL HEATERS

Routine Burner Service

SERVICE INSTRUCTIONS,HOOVER - BAGLESS CLEANERS

Portable Oil Free Silent Series Compressor Operating Instructions

RAYPAK ILLUSTRATED PARTS LIST

en Hydronic Surface Heater S 3000 REPAIR MANUAL

Troubleshooting:Passenger Car

G72x Series Direct Spark Ignition Controls

COMMERCIAL and POOL MODELS: 302C THROUGH 902C

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

Updated technical data can be found in this document, supplemented by the Riello BX Burner Manual regarding commissioning checks and adjustments.

Section 3 Technical Information

M-3025CB-AV Fuel Pump

Maintenance of Pleasureboat Diesel Engine GM Series

SERVICE MANUAL. K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - NOTICE - K40GL Shown

by TELEFLEX SERVICE MANUAL M50/M80/M105

RAYPAK ILLUSTRATED PARTS LIST

ONE STAGE GAS BURNERS RDBS SERIES

2.0 Burner Operating Parameters and Requirements

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

Training Bulletin New Model Introduction

Troubleshooting the Transmission Hydraulic System

TFL Gas Log Lighter (TFLGLL)

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

INSTALLATION OPERATION/ MAINTENANCE INSTRUCTIONS AND PARTS LIST

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES

TC Series Cooling Systems

PRECISION UK Ltd DUPLEX AGSS PLANT

Medium and high pressure pumps

Transcription:

Mobile Diesel Heaters TOR / MIR Technical Training Course 1 Rev. No. 0 March 3 rd, 2010

MIR Indirect-fired Diesel Heaters MIR 37 WE MIRAGE 37 H MIR 55 WE MIRAGE 55 H (EURO MODELS) MIR 85 WE MIRAGE 85 H MIR 37 WU MIRAGE 125 H MIR 55 WU MIRAGE 180 H (USA MODELS) MIR 85 WU MIRAGE 290 H 2

TOR Direct-fired Diesel Heaters TOR 67 WE TORNADO 67 TOR 115 WE TORNADO 115 (EURO MODELS) TOR 67 WU TORNADO 230 TOR 115 WU TORNADO 400 (USA MODELS) TOR 175 WU TORNADO 610 3

MIR General Assembly Exhaust Duct Burner Head Fuel Pump Combustion Chamber (closed) Fuel Tank Motor Fan 4

TOR General Assembly Front Flame Shield Burner Head Fuel Pump Combustion Chamber (open) Fuel Tank Motor Fan 5

FAN MOTOR ASSEMBLY EU Motors 430W 2700 rpm 2 poles 16 µf MIR 37 WE - MIR 55 WE - TOR 67 WE 750W 1400 rpm 4 poles 20 µf MIR 85 WE - TOR 115 WE US Motors 430W 3300 rpm 2 poles 50 µf MIR 37 WU - MIR 55 WU - TOR 67 WU 750W 1650 rpm 4 poles 80 µf MIR 85 WU - TOR 115 WU 1100W 1650 rpm 4 poles 100 µf TOR 175 WU 6

FUEL CIRCUIT The fuel circuit is basically composed of : fuel tank suction and return hoses fuel filter (normal or heated) fuel pump fuel solenoid valve high pressure microhose burner head nozzle 7

Fuel Tank Available Tank Capacities 51 l (13.5 US gal) MIR 37 WE/WU - MIR 55 WE/WU - TOR 67 WE/WU 100 l (26.5 US gal) MIR 85 WE/WU - TOR 115 WE 139 l (36.7 US gal) TOR 175 WU 8

Fuel Filter Standard Filter Heated Filter 9

Fuel Pump Danfoss BFPC fuel pump (front view) Fuel pump filter BFPC 21R3 MIR 37 MIR 55 TOR 67 BFPC 21R5 MIR 85 TOR 115 TOR 175 10

Fuel Cutoff Valve 11

BURNER ASSEMBLY Swirl disc Ignition electrodes Fuel Nozzle Air Shutter Nozzle Holder Flame Sensor 12

BURNER ASSEMBLY The burner assembly includes : nozzle holder air shutter swirl disc fuel nozzle 13

BURNER ASSEMBLY ignition electrode air shutter 14

BURNER ASSEMBLY Removing burner head for maintenance and service 15

CHAMBER INLET Removing chamber inlet for maintenance/cleaning 16

COMBUSTION CHAMBER Combustion chamber (MIR) Combustion chamber inside (MIR) TOR Combustion Chamber Protection Shield (TOR) 17

TOR 175 WU Special Features Special swirl disc Special BCU with shortened safety time: 5 s 18

TOR 175 WU Special features 19

WIRING DIAGRAM (TOR/MIR EU) 20

WIRING DIAGRAM (TOR 67/MIR 37/MIR55) 21

WIRING DIAGRAM (TOR 115/TOR 175/MIR 85) 22

ELECTRICAL BOARD The electrical board consists of: Control panel Protection casing (against water/dust) Power cable with strain relief and plug ON/OFF switch Room thermostat receptacle and cap with inner jumper (to close circuit for operation without thermostat) Reset pushbutton with built-in warning lamp High voltage ignition transformer Fuse with fuseholder Electronic burner (flame) control unit (BCU) Power Lamp 23

Control Panel and Protecting Cover Room Thermostat Socket Power Cable ON-OFF Switch Reset Pushbutton Power Lamp Protection Cover (IPX4) 24

Electronic Burner Control Unit Solenoid Valve (line) Motor (line) Transformer (line) Neutral Wires Photocell Contacts Switch Contacts 25

SAFETY DEVICES Flame Sensor (photoresistor) Detects false flame signal or anticipated ignition Monitors flame at ignition Monitors flame failure during operation Safety Thermostat (limit control, EU models only) Prevents unit overheating Requires manual reset Line Fuse Protects unit from overcurrents 26

SAFETY DEVICES Air Pressure Switch (US models only) Monitors fan pressure Shuts burner off in case of reduced pressure/airflow 27

TOR-MIR OPERATIONAL SEQUENCE 28

BASIC SERVICE PROCEDURES 29

Line Fuse Check 30

Fan motor/capacitor check 31

Smoke Index Test (Bacharach-Shell, indirect only) 1 IMPORTANT : 10 TIMES EXACTLY 32

Air Shutter Adjustment 33

Fuel Filter Maintenance 34

Burner Nozzle Maintenance 35

Burner Head Maintenance 36

Fuel Pump Replacement 37

Fuel Pressure Adjustment Pump pressure setting for all TOR/MIR: 12 bar (175 psi) 38

Ignition Electrode Service 39

Flame Sensor Service Typical sensor resistance values Light Dark ~ 100 ~ 100 k or more, tending to 40

Limit Control Reset Thermostat Settings Indirect Heaters: 170 C (338 F) Direct Heaters: 100 C (212 F) 41

Installation Guidelines Exhaust Pipe Design CORRECT INCORRECT 42

Installation Guidelines Air Ducting 43

Installation Guidelines Air Ducting Accessories MIR 37/55 MIR 85 max duct length: 40 ft max duct length: 60 ft 44

TROUBLESHOOTING SWITCH ON Check mains voltage (see data plate) Check that the green warning lamp on control panel is alight If heater is not powered: Check all electrical connections Check warning lamp Check fuse (burn-outs, damages, etc.) If fuse is burnt: Replace, use same type/rating THE HEATER STARTS no Check burner control unit See Service Manual Replace burner control unit yes 45

Check that lock-out warning lamp (red) is not alight Lock-out from previous operation: Wait 30 seconds and press reset button Check that overheat thermostat has not been activated Safety thermostat action from previous operation: Open inspection cover and push thermostat reset button Check that room thermostat is properly connected and adjusted Check connections Set on a temperature higher than room temperature For operation without remote thermostat: check that thermostat socket cap is correctly inserted Check electric jumper inside cap Reinsert and lock cap 46

Check that fuel tank is full Fill tank with proper clean fuel Check for air bubbles or leaks in fuel lines Tighten fuel line fittings Check for damages/cracks in fuel hoses THE HEATER STARTS, THE PREPURGE SEQUENCE STARTS BUT THEN THE HEATER STOPS WITHOUT IGNITION no yes Check that nozzle is clean Check that swirl disc is clean Check that flame sensor is not damaged, clean and properly fixed in its seat See Service Manual Cleaning the combustion head See Service Manual Cleaning the combustion head Clean flame sensor with a soft cloth and ethylic alcohol Replace flame sensor if damaged or burnt Check air shutter adjustment See Setting Chart Check presence of external false flame signals (sunlight, lamps, etc.) during prepurge time Check - and remove - light reflections due to sunrays, lamps etc. that could reach and disturb the flame sensor Look for flames inside chamber 47

Check nozzle size Check for correct nozzle size on setting chart. Replace nozzle if necessary Check air shutter adjustment See setting chart HEATER STARTS, FLAME IGNITES BUT COMBUSTION IS NOT GOOD yes Check that nozzle is clean Check that fuel filter is clean Clean or Replace nozzle See Service Manual chapter 3.8 See Service Manual chapter 3.7 no Check that pump filter is clean See Service Manual chapter 3.12 48

Check that there are no air bubbles in the fuel lines Tighten fittings Replace faulty pipes/hoses Incorrect fuel pressure Measure and adjust fuel pressure Replace pump (see Service Manual chapter 3.12) Fuel of incorrect type, dirty, polluted or containing water Empty tank and refill with clean fuel of proper type 49

THE BURNER SHUTS OFF DURING OPERATION AND THE FAN CONTINUES TO ROTATE (US MODELS ONLY!) yes Trip of air pressure switch Check air inlet/outlet for blockage, restrictions, etc. Check supply voltage, motor fan rpm, fan blades, fan/shaft coupling no 50

Excessive overheating of combustion chamber (overheat thermostat correctly activated) Wrong (too large) nozzle size Wrong (too high) fuel pressure Insufficient ventilation air due to motor fault Insufficient ventilation air due to fan failure Blockage of air inlet/outlet due to dirt or foreign objects Exhaust pipe obstruction Combustion chamber clogged by soot. (see chapter.3.10) THE HEATER SUDDENLY STOPS yes no Overheat thermostat incorrectly activated Wrong location of overheat thermostat (after incorrect service, repairs etc.) Wrong thermostat setting/type Faulty thermostat OK 51

MIR WE (EU) - SETTING CHART CHAMBER INLET FAN SWIRL DISC FUEL PUMP FUEL PRESSURE BURNER NOZZLE AIR LOCK OPENING OVERHEAT THERMOSTAT MIR 37 WE (EU) # 8 holes 6 mm dia. dia.=350mm 3 blades 22 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R3 12 bar DANFOSS 0.65 60 H 3 mm lock position 1 170 C (red markings) MIR 55 WE (EU) # 8 holes 6 mm dia. dia.=350mm 4 blades 18 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R3 12 bar DANFOSS 1.00 60 H 6 mm lock position 1.5-2 170 C (red markings) MIR 85 WE (EU) # 8 holes 10 mm dia. dia.=500mm 4 blades 33 out. dia.=76mm in. dia.=22mm 10 blades DANFOSS R5 12 bar DELAVAN 1.50 80 W 20 mm lock position 5.5 170 C (red markings) 52

TOR WE (EU) - SETTING CHART CHAMBER INLET FAN SWIRL DISC FUEL PUMP FUEL PRESSURE BURNER NOZZLE AIR LOCK OPENING OVERHEAT THERMOSTAT TOR 67 WE (EU) # 8 holes dia. 6 mm dia.=350mm 4 blades 18 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R3 12 bar DANFOSS 1.25 60 H 10 mm lock position 2.5 100 C (black markings) TOR 115 WE (EU) # 8 holes dia. 10 mm dia.=500mm 4 blades 33 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R5 12 bar DELAVAN 2.25 80 W 28 mm lock position 8.5 100 C (black markings) 53

MIR WU (USA) - SETTING CHART CHAMBER INLET FAN SWIRL DISC FUEL PUMP FUEL PRESSURE BURNER NOZZLE AIR SHUTTER SETTING OVERHEAT THERMOSTAT MIR 37 WU USA # 8 holes 6 mm dia. dia.=350mm 3 blades 18 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R3 12 bar 175 psi DANFOSS 0.65 60 H 3 mm lock position 1 170 C (red markings) MIR 55 WU USA # 8 holes 6 mm dia. dia.=350mm 3 blades 18 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R3 12 bar 175 psi DANFOSS 1.00 60 H 7 mm lock position 2 170 C (red markings) MIRAGE 85 WU USA # 8 holes 10 mm dia. dia.=500mm 4 blades 33 out. dia.=76mm in. dia.=22mm 10 blades DANFOSS R5 12 bar 175 psi DELAVAN 1.50 80 W 14 mm lock position 3.5-4 170 C (red markings) 54

TOR WU (USA) - SETTING CHART CHAMBER INLET FAN SWIRL DISC FUEL PUMP FUEL PRESSURE BURNER NOZZLE AIR SHUTTER SETTING OVERHEAT THERMOSTAT TOR 67 WU USA # 8 holes dia. 6 mm dia.=350mm 3 blades 18 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R3 12 bar 175 psi DANFOSS 1.25 60 H 4 mm lock position 1.5 100 C (black markings) TOR 115 WU USA # 8 holes dia. 10 mm dia.=500mm 4 blades 33 out. dia.=76mm in. dia.=27mm 10 blades DANFOSS R5 12 bar 175 psi DELAVAN 2.25 80 W 13 mm lock position 3.5 100 C (black markings) 55

SERVICE & MAINTENANCE TOOLS 56