Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

Similar documents
Highbay Fluorescent - Six Lamp Flat Profile Design

Highbay Fluorescent - Six Lamp Low Profile Design

Fixture Spec Sheet HFB3 Series 4/15/2011

Fixture Spec Sheet HFA2 Series 4/15/2011

Vaporproof Strip - 4 Foot 1-3 Lamps

Linear Fluorescent Lighting. Energy-Saving Lighting Systems

TCPHB4UNI1250K10 4' 12, 000 Lumen Unv Volt Led High Bay 5000K


LED Stairwell Fixture

LED Flat Panel Luminaires

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

LED Flat Panel Luminaires

DESCRIPTION & APPLICATION

2 LED Designer Series

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

LED Flat Panel Luminaires

LED INDOOR Lighting Guide

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

LHBC Commercial-Grade High or Low Bay Luminaire

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

LED E-Series. we know light. LED Cents LED E-Series troffers gives you the appearance of fluorescent technology with a tube-like glow.

PDMHB Watt LED I-Beam High Bay

PHONE: (303) FAX: (970) WEBSITE:

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

LEN Series 2x2 / 2x4 LED

HBLEDLD524SEWUNV Hbledld524sewunvl850ed2u

LED Black Housing High Output Remote Capable

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

L CHTM. LCH Lensed LED Channel LED. Technical Specifications. LCH Lensed LED Channel Configuration. Project Catalog Number Type Date

LHBIP LED High Bay High Performance

PHONE: (303) FAX: (970) WEBSITE:

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Metalux HB LED STANDARD EFFICACY

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

HOME COMPANY LED PRODUCTS T5 PRODUCTS TECHNOLOGY FIND A REP FEATURED PROJECT PROJECTS LOGIN

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

Applications. Illustrated Features

Metalux HB LED STANDARD EFFICACY

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

PART #: PROJECT: NOTES: APPROVAL SIGNATURE: Color Rendering (CRI) QTY Series

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Metalux HB LED STANDARD EFFICACY

PHONE: (303) FAX: (970) WEBSITE:

Standard Grade 14 Inch Reflector. Ordering Information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Lighting Tables for Existing/Base Equipment 4/15/2011

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Test Sample Description Catalog Number: Description:

Model Size # Lamps Lamp Type Voltage Options RDI-C 2X MV. T5 Lamps 14= F14T5 24 = F24T5HO. T8 Lamps 17 = F17T8

T5 COOL BEAM FLUORESCENT HIGH BAY (6 LAMP FULL BODY SPECIFICATION GRADE) Up to 700 L. for T5 or T5HO (Blank) (Blank) Electronic Program Start

Calibration Due Date Chroma Programmable AC Source 61604

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

Lighting Tables for Existing/Base Equipment 4/15/2011

Luminaires - LED High Bay

HBL HIGH-BAY INDUSTRIAL LUMINAIRE

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

NIPPO Seamlessline LED PRODUCT LISTING

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

Calibration Due Date Chroma Programmable AC Source 61604

Lumination LED Luminaires

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

PROJECT INFORMATION. Catalog No.

RLP Edge-Lit 2X2, 2X4, 1X4

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

Lighting Systems Argus-7

FVT / LED Vapor Tight

FVH / LED Vapor Proof Highbay

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

DURA BAY LINEAR SERIES

DELIVERING QUALITY LIGHT BETTER. Linear LED LOW BAY HIGH BAY WET LOCATION

BEAM SPREAD NR = Narrow (36 degree) WD = Wide (56 degree) WW 2 = Wall Wash. REFLECTOR FINISH SD = Semi- Diffused

LINEAR LED. Delivering Quality Light Better LOW BAY HIGH BAY WET LOCATION EDGE LIT PANELS 2' HIGH BAY NOW IN STOCK INTRODUCING

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

PHONE: (303) FAX: (970) WEBSITE:

Lighting Tables for New Equipment 3/9/2016

PHONE: (303) FAX: (303) WEBSITE:

Areamaster LED Flood/High Bay Luminaires

Lighting Tables for New Equipment 7/16/2008

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5

Applications. Standard Materials

SIRIUS ON/OFF SU OF50SUS PRODUCT SPECIFICATION PRODUCT DESCRIPTION CERTIFICATIONS & QUALIFICATIONS E DIMENSIONS. Tolerance Range : ± 10%

L1EPH ECONO LED HIGH BAY LUMINAIRE FEATURES AND SPECIFICATIONS MOUNTING OPTIONS & ACCESSORIES OVERVIEW

Lighting: Explosionproof Area HID. Applications. Standard Materials

Industrial and Commercial Series LED Low / High Bays

RTR Gen 3/ LED Troffer Conversion Kit

Nema Head We light your world

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100

TUNABLE SPECTRUM/TUNABLE WHITE

Lighting Tables for New Equipment 2/24/2015

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

Transcription:

- 3 or 4 Lamp Curved Profile Design Description HFB3 series high-bay fluorescent fixture is a great energy saving alternative to traditional HID highbay fixtures. This fixture operates three or four lamps and as a standard feature comes equipped with Howard ballasts. Applications Warehouse Manufacturing Facility Features Gymnasium Cafeteria Auditorium Easy access to wiring compartment & ballast Access plate provides access to electrical wiring with-out the need to open the fixture Knock-outs for easy electrical wiring and assembly Factory Installed Occupancy Sensor option Factory Installed Emergency ballast option Factory Installed Wrap Lens option Lamp Installation option available Multiple power cord set options, (voltage, length, gage) Pendant mount kit provides a top J-box to simplify HID retrofit installations. Can be used with a hook or rigid conduit and fasteners (Fixture must be specified with J option) Choice of 86% Standard Specular Aluminum Reflector, 95% Specular Enhanced Aluminum Reflector or 91% White Reflector Heavy Duty pre-painted steel construction Wireguard available (not factory installed) Custom configurations available Can be easily mounted by a single person Suspended or Pendant mounting insures a quick painless install Chain and V-Clip Hanging option Wire cable hanging option. UL Listed for Damp Locations Curved design for better light distribution 3.6 Benefits Energy Saving Compared to HID systems Exceptional Color Rendering High System Efficacy Long Lamp Life Instant On/Re-strike Capability Howard Ballast and Howard Lamp as a system is covered by Howard Industries Warranty Quality Lamp holders Computer Designed Reflectors System Tested, Designed, Approved, and Manufactured by Howard Industries in Mendenhall Mississippi. Compliant with Safety and performance standards. 13.0 Six 3/4 knockouts for easy wiring access 4 on top and one on each end provides clean mounting for occupancy sensor 48 Chain and V-Clip mounting option (CV) Rigid heavy gage prepainted steel body Contractor friendly one screw access to electrical connections through this access plate removable from the outside Hinged reflector/socket bar assembly for easy two screw access to the ballast compartment Factory Installed Option J Pendant Mount Kit (PMK2) installs from the outside: no need to open the fixture Wire Cable Hanging mounting option (WCH) Pendant Mount lances included only if Factory Installed Option J is selected.

- 3 or 4 Lamp Curved Profile Design Ordering Information Model Family Reflector No. of Lamps Lamp Type/ CRI/CCT Ballast Input Volts Factory Installed Wattage (1) Options Cordset Options (consult customer service for other cordset options) T B A Pack. HFB3 E 4 32 A P8 MV 00A 07 0 I HFB3 E: Enhanced Specular Aluminum (95%) A: Specular Aluminum (86%) W: White reflective (91%) 3 4 T8 Lamps 28: F28T8 32: F32T8 T5 Lamps 28:F28T5 54: F54T5HO CRI CCT A: No Lamps B: C: D: E: F: G: H: I: J: K: L: M: N: 6500 High Lumen T8 T5 SE: SBF High Eff(2) HE: HBF High Eff (2) LE: LBF High Eff (2) PS: PRS T5 P8: PRS T8 (2) MV: 120-277v HV: 347-480v (T5HO) A: 480-277 (3) 000: No FIOs A: Occ Sensor (4) B: Emergency Ballast (5) D: Wrap Lens (6) I: Special Wiring Instructions J: J-box config. (7) T: Toggle switch bilevel lighting control (8) 00: Standard Disconnect 01: 6 SJT 18/3, no plug 02: 10 SJT 18/3, no plug 03: 6 SJT 18/3 L5-15, twist lock 120v 04: 10 SJT 18/3 L5-15twist lock 120v 05: 6 SJT 18/3 5-15non twist lock 120v 06: 10 SJT 18/3 5-15non twist lock 120v 07: 6 SJT 18/3 L7-15 twist lock 277v 08: 10 SJT 18/3 L7-15 twist lock 277v 09: 6 SJT 7-15 non twist lock 277v 10: 10 SJT 7-15 non twist lock 277v 11: 16/3, no plug spec len 12: 16/4, no plug spec len 16: 16 SJT 18/3 7-15, non twist lock 277v 17: 18/3, no plug spec len 18: 6 STW L8-20, twist lock 480v 19: 10 STW L8-20, twist lock 480v 20: 16 SJT 18/3 L5-15, twist lock 120v 21: 16 SJT 18/3 L5-15, twist lock 277v I: Single B: Bulk (1) Lamp installation available. (2) High Efficiency ballasts are CEE Listed. (3) Step-down autotransformer. Allows hook-up of standard MV ballast to 480v. (4) Occupancy Sensors should be used with programmed rapid start ballasts for maximum lamp life. Standard Occupancy Sensor requires neutral wired fixtures (ex. -120v or -277v). For phase-to-phase voltage applications (240v) advise Customer Service at time of request. (5) Please specify Emergency Ballast (120-277v only) lumen requirements at time of request. (6) Standard acrylic prismatic, pattern 12, 0.100 thick. Call for options. (7) Unless otherwise specified, fixture will include field installed J-box. Supply wires will exit the center of the fixture, not the access plate. J-box can be installed without entering the fixture. (8) Allows for separate control of two ballasts through simple toggling of a standard wall switch. Recommend use of programmed rapid start ballast with this control. SE Standard Ballast Factor High Efficiency Instant Start T8 Ballast HE High Ballast Factor High Efficiency Instant Start T8 Ballast LE Low Ballast Factor High Efficiency Instant Start T8 Ballast PS Program Rapid Start T5 Ballast P8 Program Rapid Start High Efficiency T8 Ballast Sample Ordering Number: HFB3 E 4 32 A P8 MV 00A 07 I Enhanced Specular Aluminum Reflector 4-lamps (none installed) F32T8 Program Rapid Start High Efficiency Ballast Multi-volt (120-277v) Occupancy Factory Installed Options 6 SJT 18/3 cord L7-15 277v twist lock plug Single Packaging

Field Installed Options Ordering HFB3-WG Wire Guard HFA-WCH Wire Cable Hanging Kit (2 pcs per kit) HF-PMK2 Pendant Mount Kit with 1.0 diameter through hole HF-2CV (2 foot) HF-3CV (3 foot) Hanging Chain & V-clips HF-SK1 Stabilizer Kit (Hub, color and wire cable) HFB3-WL Wrap Lens Energy Cost Estimator Existing System New System Hours burned per year Cost per kwh$ 4368 0.12 Energy Cost Estimation 250W MH Highbay Number of Fixtures Watts per Fixture (existing Energy used per year (existing 1 272 $143 HFB3E432AP8 Prog. Start High Eff Fluorescent Highbay Number of Fixtures Watts per Fixture (new Energy used per year (new 1 112 $59 Energy saving per year (per fixture) $84.00 $250 $200 $150 $100 $50 $0 59% Annual Savings $143 $59 Existing System New System

Photometric Data - 4 Lamp T8 (HFB3E432) Candela Polar Plot Luminaire Efficiencies* Reflector Type T8 Enhanced Specular 90.9% Specular 84% White % *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. Zonal Lumen Summary Zone Lumens %Lamp %Fix 0-30 2796.29 24.10 26.50 0-40 4443.61 38.30 42.10 0-60 7633.57 65.80 72.40 0-90 10415.48 89.80 110 0-180 10544.8 90.90 100.00 HFB3E432 Test Report: HFB3E432.ies Spacing Criteria (0-180): 1.28 Spacing Criteria (90-270): 1.12 Spacing Criteria (Diagnonal): 1.30 Maximum Candela = 3798.24 Located at Horizontal Angle = 70, Vertical Angle = 5 #1 = Vertical Plane Through Horizontal Angles (70-250) Through Max Cd. #2 = Vertical Plane Through Horizontal Angles (45-225) #3 = Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.) Coefficients of Utilization - Zonal Cavity Method Luminance Data (cd/sq.m) Angle In Degrees 0-deg 45-deg 90-deg 45 7999 5689 5384 55 17 5036 6938 65 6806 5279 5798 5619 4965 5566 24 3142 3597 Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 107 107 107 107 105 105 105 105 100 100 100 96 96 96 92 92 92 90 1 96 92 87 83 94 90 86 82 86 82 79 82 79 77 79 77 73 2 87 79 73 67 77 71 66 74 69 65 71 67 63 68 65 62 60 3 79 69 61 55 77 68 61 55 65 59 54 63 57 53 60 56 52 50 4 73 61 53 47 70 60 52 46 58 51 46 56 50 45 54 49 44 42 5 67 55 46 40 65 54 46 40 52 45 39 50 44 39 48 43 39 37 6 62 49 41 35 60 48 41 35 47 40 35 45 39 34 44 38 34 32 7 57 45 37 31 56 44 36 31 43 36 31 41 35 30 40 34 30 28 8 53 41 33 28 52 40 33 28 39 32 27 38 32 27 37 31 27 25 9 50 38 30 25 49 37 30 25 36 29 25 35 29 25 34 29 25 23 10 47 35 28 23 46 34 27 23 33 27 23 33 27 22 32 26 22 21

Photometric Data - 4 Lamp T5 (HFB3E454) Candela Polar Plot Luminaire Efficiencies* Reflector Type T5 Enhanced Specular 93% Specular 88% White 88% *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. Zonal Lumen Summary Zone Lumens %Lamp %Fix 0-30 5018.63 25.10 26.90 0-40 8217.01 41.10 44.00 0-60 14314.51 71.60 76.60 0-90 18683.6 93.40 100.00 0-180 18683.6 93.40 100.00 HFB3E454 Test Report: HFB3-454-MOD.ies Spacing Criteria (0-180): 1.26 Spacing Criteria (90-270): 1.30 Spacing Criteria (Diagnonal): 1.40 Maximum Candela = 6505.34 Located at Horizontal Angle = 60, Vertical Angle = 10 #1 = Vertical Plane Through Horizontal Angles (60-240) Through Max Cd. #2 = Vertical Plane Through Horizontal Angles (45-225) #3 = Horizontal Cone Through Vertical Angle (10) (Through Max. Cd.) Coefficients of Utilization - Zonal Cavity Method Luminance Data (cd/sq.m) Angle In Degrees 0-deg 45-deg 90-deg 45 15860 15289 14862 55 14682 13909 12227 65 13288 11505 13835 11396 12493 12773 9001 7421 7403 Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 111 111 111 111 109 109 109 109 104 104 104 99 99 99 95 95 95 93 1 101 96 92 88 98 94 90 87 90 87 84 84 86 81 83 81 79 77 2 92 84 77 71 89 82 76 70 78 73 69 71 67 72 69 66 64 3 83 73 65 59 81 72 64 59 69 63 58 66 61 57 64 59 56 53 4 76 65 56 50 74 64 56 50 61 54 49 59 53 48 57 52 48 46 5 70 58 49 43 68 57 49 43 55 48 42 53 47 42 51 46 41 39 6 65 52 44 38 63 51 43 37 50 42 37 48 42 37 46 41 36 34 7 60 47 39 33 58 47 39 33 45 38 33 44 37 33 42 37 32 30 8 56 43 35 30 54 42 35 29 41 34 29 40 34 29 39 33 29 27 9 52 40 32 27 51 39 32 27 38 31 26 37 31 26 36 30 26 24 10 49 37 29 24 48 36 29 24 35 28 24 34 28 24 33 28 24 22