Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Similar documents
Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report No

Test report No

Test report No

Test report no

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

FIRE TEST REPORT FH 5078

FIRE TEST REPORT FH 5728

Test report No

Classification report No K1

FIRE TEST REPORT FH 5154

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

MITRAS MATERIALS GMBH

PRODUCT EVALUATION REPORT

Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5

Test report no

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

Test report no

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

National Standard of People s Republic of China

Determination Of Fire Effluents From Products On Railway Vehicles

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Oxygen Bomb Calorimeter

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

Test Report. No. SHAHG Date: 11 Nov Page 1 of 7.

The Furniture Retail Quality Group Best Practice Guide

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Test Report. CHTC JIAHUA NONWOVEN CO.,LTD No.99,WaGou New Village, Pengchang,Xiantao,Hubei, CHINA

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

Test Report No.: SHHG MD Date: FEB. 26, 2016 Page: 1 of 17

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Test Report. No. SHAHG Date: 07 Nov Page 1 of 9.

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

Urban Wildfire Interface: Exterior Wall Wildfire Testing

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

INTERNATIONAL STANDARD. Download aus SNV-Livelink, Schweiz. Normen-Vereinigung SNV. Max Peter

Test Report No

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

ST/SG/AC.10/C.3/2017/3. Secretariat. United Nations. Stability tests for industrial nitrocellulose. Introduction

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

EU Mutual Recognition Technical Requirements

Durable Goods Labelling Compliance

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia

Ignition Temperatures of R1234yf

FIBRE UKANOL ES REACTIVE FLAME RETARDANT ADDITIVE FOR POLYESTER

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

SFI SPECIFICATION 3.3 EFFECTIVE: AUGUST 26, 2016 *

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Test Report. No. SHAHG A01 Date: 10 May Page 1 of 6.

E/ECE/324/Rev.2/Add.117/Amend.1 E/ECE/TRANS/505/Rev.2/Add.117/Amend.1

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

SGS TEST REPORT. Page: 1 of 8 Date: April 15,2010. itech Company LLC Christy Street, Fremont CA USA

Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4

NFPA 1951 Standard on Protective Ensembles for Technical Rescue Incidents

Test Report. No. NGBHG Date: 28 Jun Page 1 of 6.

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, FLEXIBLE, CROSSLINKED

Report Number BTC 12024F

InnoBYG small scale demonstration tests - Part 2

Cast Resin Transformers

CERTIFICATE of QUALITY TEST

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Prototype Test Report Quadri*Sil 300 Line Post Insulators Report Number: R

Lab services for aircraft interior components

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

Reliability Test Report

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

Designed to prevent condensation and energy losses

Laboratory Report. U. S. Department of Justice

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

OSU Rate of Heat Release Apparatus

Transcription:

Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 1 of 6 IGEPA GROUP GmbH & CO., KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description: MASTERJET S MESH PRO 370 B1 HURRICANE / XXL 270 B1 TAIFUN Style/Item No.: SBI-MPR* / SBI-MPXXLR* Composition: PVC AND POLYESTER Test Requested: To determine the flammability (building materials class B1) in accordance with DIN 4102-1 (May 1998) Fire behaviour of building materials and elements Part 1: Classification of building materials, Requirements and testing Test Results: -- See attached sheet -- Classification: The tested sample meets class B1 building materials requirements of DIN 4102-1 (May 1998). Test Period: Sample Receiving Date : JUN.06, 2016 Test Performing Date : JUN.06, 2016 TO JUN.20, 2016 Signed for and on behalf of SGS-CSTC Co., Ltd. Anji Branch Allen Zou Technical Manager

Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 2 of 6 I. Test conducted This test was conducted as per DIN 4102-15:1990, DIN 4102-16:1998 and DIN 4102-1:1998 Clause 6.2, and Classification in according to DIN 4102-1 (May 1998) Clause 6.1-Class B1 materials. II. Sample details General description Color MASTERJET S MESH PRO 370 B1 HURRICANE / XXL 270 B1 TAIFUN White Density About 254 g/m 2 Size of sample 1000mm 190mm & 190mm 90mm Conditioning Prior to testing, the sample was conditioned at least 14 days to constant mass at a temperature of 23 ± 2 C, III. Test results and a relative humidity of 50 ± 6 %. 1) Brandschacht Test according to DIN 4102-15 &16 Exposed surface: The front face Line No. 1 Results of Brandschacht Test (part 1) Specimen fixings according to DIN 4102 part 15, table Unit - 1 2 Max. flame height above lower sample edge; cm 30 3 Time 1) min:s 0:12 Melting/burning through 4 Time 1) min:s 0:06 Back of specimen 5 Flaming/glowing, Time 1) min:s 0:08 6 Discolouring, Time 1) min:s 0:05 Test assemblies No. A B C D Burning droplets 7 Begin 1) min:s / Amount / 8 Specimen material falling off in separate droplets / 9 Specimen material falling off continuously /

Line No. Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 3 of 6 Burning parts Results of Brandschacht Test (part 2) Unit 10 Begin 1) min:s / 11 Parts of sample falling off separately / 12 Parts of sample falling off continuously / 13 Duration of continued combustion on mesh base (max.) Burner flame impairment by dripping/falling material min:s 14 Time 1) min:s / Premature ending of test / 15 End of burning at specimen 1) min:s / 16 Time when test terminated (if applicable) 1) min:s / Burning after end of test 17 Duration min:s / 18 Number of specimens / 19 Front of specimen / 20 Back of specimen / 21 Height of flame cm / Glowing after end of test 22 Duration min:s / 23 Number of specimens / 24 Front of specimen / 25 Back of specimen / 26 Top half of specimen / 27 Bottom half of specimen / Test assemblies No. A B C D

Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 4 of 6 Results of Brandschacht Test (part 3) Line No. Unit Test assemblies No. A B C D Residual length 28 Single results cm 71 68 65 75 29 Average of the single results cm 69.8 Smoke temperature 30 Max. of average 136.2 31 Time 1) min:s 06:45 Note: 1) time from start of testing *Reduction in number of test (DIN 4102 Part 16, clause 5.2) Class B1 materials: If the residual length measured after the first test is 45cm or greater, further tests are not required. 2) Normal Flammability Test according to DIN 4102-1 Clause 6.2 Flame application: [ ] bottom edge ignition, [ ] surface ignition Specimen No. 1 2 3 4 5 Reaching the measuring mark within 20 seconds No No No No No Self extinguishing of the flame (s) 15 15 15 15 15 Max. flame height (cm) 9 10 8 9 9 End of afterflaming (s) 15 15 15 15 15 End of afterglowing (s) 15 15 15 15 15 Molten dripping No No No No No Smoke developments (visual impression) Slight All timings are from start of testing.

Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 5 of 6 IV. DIN 4102-1:1998 Criteria for classification 1) All materials, except flooring, may be classed as B1 materials if they meet the following requirements a) and b): a) The test using the Brandschacht apparatus described in DIN 4102-15 (cf. subclause 6.1.3.1) shall be deemed passed if The mean value for the residual length (portion of specimen that has not burned or charred; cf. subclause 9.1 of DIN 4102-16) of each specimen is at least 15 cm and no individual values are lower than 0 cm, The mean effluent temperature does not exceed 200 C in any test, The requirement for the residual length of each specimen is met even where there is afterflame, afterglow, or smouldering. b) Pass DIN 4102-1: 1998 sub-clause 6.2.3 Ignitability Test if For each specimen, flaming doesn t reach the gage mark within 20s after flame application. 2) Materials may be classed as B2 materials if they pass the ignitibility test specified in DIN 4102-1: 1998 subclause 6.2.5. For each specimen, flaming doesn t reach the gage mark (150mm marks) within 20s after flame application. 3) Combustible materials which cannot be classed as B1 or B2 materials shall be classed as B3 materials. STATEMENTS: This test report does not replace any mandatory certification of the product that may be required. The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire and smoke hazard of the product in use.

Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 6 of 6 Photo Appendix: SGS authenticate the photo on original report only ***End of Report***