Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Similar documents
Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Return Line Filter RF

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Pressure Filter DF...K P, DF...M P, Flange Mounted

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Change-Over Pressure Filter DFDK

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Return Line Filter RF

Return Line Filter RFM with 4-Hole Mounting

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Change-Over Inline Filter RFLD Welded Version

Return Line Filter RFM with 4-Hole Mounting

Change-Over Inline Filter RFLD Weld Version

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Change-Over Inline Filter AFLD to API 614

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

Return line and Suction Boost Filter RKM

HIGH PRESSURE FILTERS

Return Line Filter RFM with 2-Hole Mounting

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

HIGH PRESSURE FILTERS

MultiRheo Filter MRF 1/2/3/4/5/6/7

Series RFLD Duplex In-Line Filter

MultiRheo Filter MRF 1/2/3/4/5/6/7

High-pressure inline filter, flangeable

Series RFL In-Line Filter

MEDIUM PRESSURE FILTERS

Block mounting filter, lateral flange-mounting possible

Plastic Tank Systems Standard models

SPIN-ON FILTER - LOW PRESSURE LINE

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Stainless Steel Pressure Filters

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Process Inline Filter Medium / High Pressure PFM / PFH

High Pressure Filter Pi 4230

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Duplex Pressure Filters

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

Line filter with filter element according to DIN 24550

NFH Low Pressure Filters

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

HIGH PRESSURE FILTERS Series HF2P

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

Block mounting filter, for lateral flange-mounting

Inline filter with filter element according to DIN 24550

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

High Pressure Filter Pi 4230

Block mounting filter, for vertical flange-mounting

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

LowViscosity Housing Filter LVH-F

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

FILTER ELEMENTS. Overview of Elements PN# / / FIL

Inline filter with filter element according to DIN 24550

High Pressure Filter Pi 4000

Innovative Element Technology for installation in HYDAC filters E / Quick Selection -

Medium Pressure Filter Pi 360

Block mounting filter, for lateral flange-mounting

Low Pressure Filter Pi 200

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min

Low Pressure Filter Pi 2300

High Pressure Filter Pi 420

Medium Pressure Filter Pi 3000

Low Pressure Filter Pi 200

Series TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface

Return line filter for direct tank mounting Type ABZFR

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Low Pressure Filters

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Medium Pressure Filter Pi 340

Reservoir oil filler/breather

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

Inline filter with filter element according to DIN 24550

High Pressure Filter Pi 410

Suction Filter Pi 200

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

Low Pressure Filter Pi 2000

Low Pressure Filters

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e

Block mounting filter, for sandwich plate mounting

High Pressure Filter Pi 422

Transcription:

Manifold Mounted, Rear Flanged Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 5 l/min Pressure range up to 35 bar Material: SG Iron/ADI, Steel

. DESCRIPTION.. FILTER HOUSING Construction The filter housings have been designed in accordance with international regulations. They consist of a filter head and a screw-in filter bowl. Standard specification: Mounting holes in the head -piece bowl for size 66 and above Suitable for HFA/HFC fluids Oil drain plug with automatic pressure relief (for size 33 and above) Interface DF 6-8 M A / DF 6-8 MHA: Outlet above inlet DF 3-8 Q E: Inlet above outlet option (size 6, 4, 8): Outlet above inlet ( /-OAI) DF 33-3 Q E / DF 33-3 MHE: Outlet above inlet.. FILTER ELEMENTS Original HYDAC filter elements guarantee reliable function and protect hydraulic components and systems which are sensitive to contamination from wear and tear. Performance and quality tests in accordance with international standards guarantee reliable operation of the filter. Hydac filters are validated and their quality is continuously monitored according to the following standards. ISO 94: Verification of collapse / burst resistance ISO 94: Verification of fabrication integrity and determination of first bubble point test ISO 943: Verification of material compatibility with fluids ISO 374: Verification of flow fatigue characteristics ISO 3968: Evaluation of differential pressure versus flow characteristics ISO 6889: Multi-pass method for evaluating filtration performance of a filter element In addition to guaranteeing retention and flow rate characteristics, the filter elements have excellent structural stability. The careful construction and mechanically stable support of the filter media guarantee aboveaverage beta value stability and flow fatigue characteristics of the filter elements. The filter elements are available with the following collapse/burst stability values: Betamicron (BH3HC) : 5 bar Betamicron (BN3HC) : bar Wire mesh (W/HC) : 3 bar Stainless steel fibre (V) : bar

.3. CLOGGING INDICATORS VD 5 D. /-L. GENERAL Mounting Manifold mounted rear flanged Type of indicator VD differential pressure indicator up to 45 bar operating pressure VM differential pressure indicator up to bar operating pressure Pressure setting 5 5 bar = standard (others on request) Indicator type code (options) B. = visual C. = electrical D. = visual/electrical Modification number the latest version is always supplied Supplementary details -V Viton -LED light-emitting diodes up to 4 volt -L.. light with corresponding voltage (4, 48,, volt) -W only for oil-water emulsions HFA, HFC (only possible for version "VD") For further details on clogging indicators, please see: brochure no.: E 7.5../.. Temperature range - C to + C (-3 C to - C: only is permissible) p max Pressure setting of the clogging indicator p a = 5 bar -.5 bar Other pressure settings on request Cracking pressure of bypass valve p O = 6 bar +.6 bar Other cracking settings on request (only for DF MA/DF QE) Circuit diagram.4. SEALS Perbunan (= NBR)..5. SPECIAL MODELS AND ACCESSORIES bypass valve (only for DF MA/DF QE) oil drain plug up to size 8 seals in FPM, EPDM test and inspection certificates differential pressure indicator.6. SPARE PARTS See Original Spare Parts List and Maintenance Instructions..7. COMPATIBILITY WITH OPERATING FLUIDS TO DIN ISO 943: Hydraulic oils H to HLPD to DIN 554 Lubrication oils to DIN 557, APJ, ACEA, DIN 555, ISO 6743 Compressor oils to DIN 556 Rapidly biodegradable operating fluids to VDMA 4568 HETG, HEES, HEPG Non-flam operating fluids HFC and HFD Operating fluids with high water content (>5% water content) on request For further details on filter elements: Brochure no.: E 7.../.. 3

3. MODEL CODE (also order example) 3.. COMPLETE FILTER Filter type DF BN/HC 6 MHE D. X -L4 Filter material BN/HC Betamicron (BN3HC) BH/HC Betamicron (BH3HC) W/HC Stainless steel wire mesh V Stainless steel fibre Size: filter and element M A: 6,, 4, 6, 4, 8 Q E: 3, 6,, 4, 6, 4, 8, 33, 5, 66, 99, 3 MHA:6, 4, 8 MHE:33, 5, 66, 99, 3 Operating pressure M: 5 bar Q: 35 bar Application No details: 6 cycles H: high dynamic for 8 cycles (only for 5 bar operating pressure) Type of connection / Connection size A: mounting holes E: 4 mounting holes Filtration rating in µm BN3HC, BH3HC, V : 3, 5,, W/HC : 5, 5,, Type of clogging indicator Y = plastic blanking plug in indicator port A = steel blanking plug in indicator port for other clogging indicators, B = visual indicator see brochure no. E 7.5../.. C = electrical indicator D = combined visual/electrical indicator Type code version with -piece bowl: up to size 66 version with -piece bowl: size 66-3 Modification number X the latest version is always supplied Supplementary details V FPM seals, filter suitable for rapidly biodegradable oils and phosphate ester (HFD-R) W suitable for oil-water emulsions HFA, HFC (only necessary when using a clogging indicator and/or V or W/HC elements) L... light with corresponding voltage (4V, 48V, V, V) only on clogging LED light-emitting diodes up to 4 volt indicators type D B. special cracking pressure of bypass (B3 = 3 bar, B6 = 6 bar; only on DF...M A / DF...Q E) SO84 pressure release / oil drain plug (up to size 8) OAI outlet above inlet (only for DF 6, 4, 8 Q E) SO348 for operating pressure p max bar (see point 4.) 4

3.. REPLACEMENT ELEMENT 33 D BN3HC /-V Size 3, 6,, 4, 6, 4 8, 33, 5, 66, 99, 3 Type D Filtration rating in µm BN3HC, BH3HC, V : 3, 5,, W/HC : 5, 5,, Filter material BN3HC, BH3HC, V, W/HC Supplementary details V = FPM seals, filter suitable for rapidly biodegradable oils and phosphate ester (HFD-R) W = element suitable for oil-water emulsions HFA, HFC (only necessary for V and W/HC elements) 4. FILTER SPECIFICATIONS Version M A Q E MHA MHE p max 5 bar 35 bar 5 bar Cycles 6 8 Temperature range -3 C to C (see point ) Pressure setting of 5 bar the clogging indicator (Standard) Type of Standard: VD clogging indicator For S 348: VM Material of filter head GGG 4 (SG iron) ADI Material of filter bowl steel Cracking pressure of bypass 6 bar no bypass valve Sizes 6-8 3-3 6-8 33-3 5

5. FILTER CALCULATION/SIZING The total pressure drop of a filter at a certain flow rate is the sum of the housing p and the element p. The pressure drop can either be determined with the aid of our Filter Sizing Program, which is available free of charge, or by using the following graphs. 5.. P-Q HOUSING GRAPHS TO ISO 3968 The housing graphs apply to mineral oil with a density of.86 kg/dm 3 and a kinematic viscosity of 3 mm²/s. In this case, the differential pressure changes proportionally to the density. DF 6//4 M A DF 6//4 Q E DF 6/4/8 M A / MHA DF 6/4/8 Q E (also /-OAI) DF 3 Q E DF 33/5/66/99/3 Q E / MHE 6

5.. P-Q GRAPHS - FILTER ELEMENTS The element graphs apply to mineral oil with a kinematic viscosity of 3 mm²/s. The pressure drop changes proportionally to the change in viscosity (see Example 5.3.).,8.8,6.6,4.4 BN3HC Size 33 Size 5 Size 66,.,8.8,6.6,4.4,. 3 4 5 BN3HC Size BG 3,8.8.9,9 BN3HC Size 99 Size 3,6.6.8,8,4.4.7,7,.,8.8,6.6,4.4.6,6.5,5.4,4.3,3.,,.., 3 4 5 6 3 4 5.8,8.6,6.4,4.,.8,8.6,6.4,4 BN3HC Size 6 Size Size 4,4.4,.,8.8,6.6,4.4 BH3HC Size 3,8.8,6.6.,,. 5 3 45 6 75 9 5 3 4 5 6.8,8.6,6.4,4 BN3HC Size 6 Size 4 Size 8,8.8,6.6,4.4 BH3HC Size 6 Size Size 4.,.8,8.6,6.4,4.,,.,8.8,6.6,4.4,. 5 5 5 5 3 45 6 75 9 5 7

,8.8,6.6,4.4,.,8.8,6.6,4.4,. BH3HC Size 6 Size 4 Size 8,6.6,4.4,.,8.8,6.6,4.4,. V Size 6 Size Size 4 5 5 5 5 3 45 6 75 9 5,8.8,6.6,4.4,.,8.8,6.6,4.4,. BH3HC Size 33 Size 5 Size 66 V.9,9.8,8.7,7.6,6.5,5.4,4.3,3.,., Size 6 Size 4 Size 8 3 4 5 5 5 5.9,9 BH3HC Size 99 Size 3,9.9 V Size 33 Size 5 Size 66.8,8.7,7.6,6.5,5.4,4.3,3.,,8.8,7.7,6.6,5.5,4.4,3.3,..,,. 3 4 5 3 4 5 V,. Size 3,8.8 V,4.4,35.35.3,3.5,5 Size 99 Size 3,6.6,4.4,..,.5,5.,.5,5 3 4 5 6 3 4 5 8

W/HC.5,5 Size BG 3.4,4.3,3 Size BG 6., Size BG., BG 4 Size Size BG 6 4 Size BG 4 Size BG 8 5 5 5 5.3. EXAMPLE General viscosity (mm²/s) p total = p housing + p element 3 mm²/s p housing = to be determined from point 5.. p element = element pressure drop according to point 5.. Example System data: Q = l/min; DF 66 Q E with BN3HC element ( µm); viscosity = 68 mm²/s p housing =.5 bar (DF 66 Q E) 68 mm²/s p element =.5 bar =.57 bar 3 mm²/s p total = p housing + p element =.8 bar.8,9,8.7,7.6,6.5,5.4,4.3,3.,., W/HC BG 33 Size 33 BG 5 Size 5 BG 66 Size 66 BG 99 Size 99 BG 3 Size 3 For ease of calculation, our Filter Sizing Program is available, and can be ordered via our website www.hydac.com. 3 4 5 9

6. DIMENSIONS 6.. DF Q E : SIZES 3-3 DF MHE : SIZES 33-3 filter mounting Size 6-8 Version /-OAI outlet inlet inlet outlet Detail X filter mounting outlet inlet For Model DF...MHE - sizes 33-3 the dimensions differ as follows: b4 = 8.5 d = 56 Type b b b b3 b4 b5 d d d d3 d4 d5 h h h3 h4 h5 h6 h7 h8 h9 h h SW O- Weight ring ) incl. element in kg 3 8 8 57 56 37 38 67 5 3 4 97 76 78 48 76 45 5.5 3.5 8 75 4 8 x.5.9 6 7 66 45 48 6 84 68 8 7 8 83 45.5 94 55 9.5 34.5 35 75 7 4 x 3 5. 7 66 45 48 6 84 68 8 84 48 5 45.5 94 55 9.5 34.5 35 75 7 4 x 3 6. 4 7 66 45 48 6 84 68 8 38 9 94 45.5 94 55 9.5 34.5 35 75 7 4 x 3 6.7 6 3 4 95 89 59 69 3 6 95 3 8 7 6 6 5 3 5 85 3 4 x 3.5 9.6 4 3 4 95 89 59 69 3 6 95 3 34 8 77 6 6 5 3 5 85 3 4 x 3.5.6 8 3 4 95 89 59 69 3 6 95 3 5 464 359 6 6 5 3 5 85 3 4 x 3.5 5.9 33 3 4 95 79.5 3 54 3 3 3 353 357 57 94 58 6 3 5 5 36 4 x 3.5.9 5 3 4 95 79.5 3 54 3 3 3 446 45 5 94 58 6 3 5 5 36 4 x 3.5 7.3 66 3 4 95 79.5 3 54 3 3 3 53 57 39 94 58 6 3 5 5 36 4 x 3.5 3.9 66 ) 3 4 95 79.5 3 54 3 3 3 5 57 5 3 94 58 6 3 5 35 36 4 x 3.5 34. 99 ) 3 4 95 79.5 3 54 3 3 3 5 673 677 477 94 58 6 3 5 5 36 4 x 3.5 4. 3 ) 3 4 95 79.5 3 54 3 3 3 5 839 843 643 94 58 6 3 5 67 36 4 x 3.5 5.3 Version: /-OAI (outlet above inlet) 6 3 4 95 83 84 59 3 6 95 3 84 39 9 64 58 6 3 5 85 3 4 x 3.5.7 4 3 4 95 83 84 59 3 6 95 3 344 99 79 64 58 6 3 5 85 3 4 x 3.5.7 8 3 4 95 83 84 59 3 6 95 3 56 48 36 64 58 6 3 5 85 3 4 x 3.5 7. ) supplied ) -piece bowl version

6.. DF M A : SIZES 6-8 DF MHA : SIZES 6-8 outlet filter mounting inlet Type b b b b4 b5 d d d d3 d4 h h h3 h4 h5 h6 h SW O-ring ) Weight incl. element in kg 6 5 83 58 4 8 68 5 85 9 83 45 58 6 75 7 9 x.5 3.5 5 83 58 4 8 68 5 5.5 59.5 5.5 45 58 6 75 7 9 x.5 4.4 4 5 83 58 4 8 68 5 96 33 94 45 58 6 75 7 9 x.5 5. 6 83 58 6 6 6 95 3.5 5 3 39 7 79 58 6 85 3 9 x.5 8. 4 83 58 6 6 6 95 3.5 5 9 99 67 79 58 6 85 3 9 x.5 9.6 8 83 58 6 6 6 95 3.5 5 474 48 349 79 58 6 85 3 9 x.5 4. ) supplied 7. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications.