Fire/smoke damper EKO-SRBG1

Similar documents
Smoke damper EKO-SRB1

Fire/smoke damper EKO-JBG2

Combustion gas damper EKO-SRB

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBL

Combustion gas damper EKO-JB

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK Fire /04/2017

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Fire damper FK120/FK90 TECHNICAL DATA

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Fire dampers ETCE and ETCS TECHNICAL DATA

PKIR3G, PKIS, PKIS3G and PKIS3GA

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

PKI-C Cartridge Fire Dampers

KSOF Fire damper valve

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

M A D E L. FOK-EIS-180 Fire dampers CE

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Ceiling swirl diffusers

series RVV Variable flow rate controllers

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

CRP. Commissioning damper, Ductwork Leakage Class 0

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

Rectangular fire damper TFER 30. pag. C-10

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Ceiling swirl diffusers

Fire Dampers Catalogue

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction

Systemair Fire Dampers

Heights up to 1000 mm Fire resistance period up to 120 minutes

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

BRC

Systemair Fire Dampers

WGA Long throw nozzle grille

CFSD Series. Product Description

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Volume Flow Limiters Type VFL

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

ESAS Smoke control damper

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Apartment ventilation

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

Fire, Smoke, and Combination Fire Smoke Dampers

Apartment ventilation

Slot diffusers, Round duct diffusers. IMP Klima

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Ceiling swirl diffusers

CONTROL SMOKE AND BALANCING DAMPERS

Smoke control damper RKI-90 Test certificate Z

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Regulation and shut-off damper SPB and SPC

FlowBar High Capacity Slot Diffuser

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

Wall and Ceiling Grille

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.

TYPE EK-EU SMOKE CONTROL DAMPER

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

Climate Recovery Duct System Technical Specifications

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

CURTAIN TYPE FIRE DAMPER

Transcription:

Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations. The damper is designed in compliance with current regulations. The damper is intended for in-wall installation in fire-containment sections conforming to fire-technical class up to EI 60. The ventilation duct can be left without any fire insulation whatever. A wire mesh grille should always be fitted when the damper is not connected to the ducting. CE-approval The EKO- fire/smoke damper has been tested by SP and approved by SP Certifiering and CE-marking 0402-CPR-SC0845-13. Design The EKO- fire/smoke damper is available with circular duct connection as standard. The damper has a factory-mounted electrical motor with spring return, end position contacts and thermal sensor. The standard EKO- is manufactured of galvanized sheet steel (C2) with damper blades and casing of fire-resistant material. Alternatively, the damper can be made of aluzinc (C4) or stainless steel for a higher corrosivity class. The damper is fitted with a gasket to seal the air side. There is also a sealing strip on the damper that expands and seals if the damper is exposed to heat. Temperature Since the EKO- damper frame is fitted with sealing strips that expand to seal off in the event of fire, the operating temperature must not exceed 70 C. Sizes The EKO- fire/smoke damper is manufactured in seven standard sizes from Ø 100 to Ø 400 mm. For diameters between 400 mm and 630 mm use EKO-SRBG2. For diameters over 630 mm use EKO- JBG2 with circular duct connection. Product data EKO- Sizes Ø 100 Ø 400 mm (EKO-). Sizes Ø 500 Ø 630 mm (EKO-SRBG2). Nipple connection in accordance with Swedish standard. Material of manufacture: galvanized, aluzinc coated or stainless sheet steel. Fire-technical class in compliance with SS-EN 15650:2010 EI 60 (ve ho i < > o) SC 20000 Testing and classification in compliance with EN 1366-2 and EN 13501-3. CE-marking 0402-CPR-SC0845-13. The damper conforms to air tightness class 2 and the casing conforms to air tightness class B according to EN 1751:1998. The damper conforms to air tightness class 2 and pressure class B according to AMA VVS & Kyl 12. The differential pressure over a closed damper can be 2500 Pa, corresponding to pressure class B. Conforms to environmental class C2. AMA VVS code QJC.2 Fire/smoke damper EKO-. EI 60 S Tel +46 40 42 16 00, Fax +46 40 421 25 18, info@ekovent.se, www.ekovent.com 2017-10 1 (9)

Motors The EKO- is supplied with a 24 V or 230 V electrical safety motor supplemented with a thermal sensor and test button for manual testing of functioning in situ. If the temperature exceeds 70 C inside or outside the damper, the sensor cuts off the power to the motor and the fire damper is closed. The same thing happens in the event of a power cut. A 24 V motor is always used together with the monitoring units EKO-KE 2-16 and EKOTME/TSE. A 230 V motor is used for the EKO-MKE/SKE monitoring unit. Note that the damper must always be delivered with a factory-mounted safety motor if P-certification is to be valid. Maintenance External and internal inspection Check electricity cables to the motor, smoke detectors and thermal sensor to ensure that they are not damaged. Check the damper casing, the motor attachment, damper blades and sealing strip to ensure that no damage has occurred. Function control Check that the damper is fully open when operating, closes and opens fully when tested, and closes completely when power is cut off. Otherwise follow the instructions for the EKO MKE/SKE/KE/TME/ TSE control and monitoring system. Note After inspection the fire damper should be left in normal working position. Installation Installation must always be done in accordance with the supplied installation instructions. An installation device for attaching the damper to a wall and angle brackets for ducts are included in the damper delivery. Other components, such as couplings and fire collars, must be ordered separately. The size of the hole is always the dimension of the damper + 55 mm. The pivot shaft of the damper can be installed in any position. Accessories EKO-GIS Plasterboard wall sleeve, excl. fire sealant kit. EKO-KER Fire sealing kit for wall. EKO-FNS Extension adapter with wire mesh grille. EKO-KPB Junction box. EKO-RE Smoke detector (duct). EKO-RET Smoke detector (ceiling). EKO-KE Control and monitoring system. EKO-MKE/SKE Control and monitoring system. EKO-TK Test button. EKO-TME/TSE Control and monitoring system. EKO-NRS Wire mesh grille. Cleaning We recommend preventive maintenance of the damper according to the needs of the installation. Damper blades and body (interior) should be cleaned by brushing, vacuum cleaning or wiping down. NOTE! No water or other liquid may be used. How to order the EKO- Designation: Fire/smoke damper EKO--A-B-C A B C SIZE MATERIAL MOTOR 1 = Galvanized (C2) 5 = Motor 24 V Ø 2 = Aluzinc (C4) 6 = Motor 230 V 3 = Stainless EN 1.4301 4 = Stainless EN 1.4404 Example: 1 Fire/smoke damper EKO--160-1-5 Tel +46 40 42 16 00, Fax +46 40 422 25 18, info@ekovent.se, www.ekovent.com 2017-10 2 (9)

Technical data EKO- Dimensions EKO- C 200 B Dimensions EKO-SRBG2 B 230 (100-400) 260 (500-630) B EKO EKO SRBG2 70 55 OA 70 55 OA 38 90 53 181 41 120 41 202 Standard sizes and weights EKO- ØA B C Weight* 100 100 3.3 125 125 3.6 160 160 14 4.1 200 200 35 4.7 250 250 15** 60 5.7 315 315 48** 93 7.1 400 400 91** 136 8.8 * Weight in kg, including motor ** Extension adapter required for short connection sleeve EKO-SRBG2 ØA B C Weight* 500 500 150** 12.8 630 630 215** 16.2 Electrical data Dimensioning effect VA Max running time s EKO- Damper motor Safety class ** 24 V AC/DC 230 V Motor Spring 100-400 BLF 7 7 40-75 20 IP54 Dimensioning effect VA Max running time s EKO-SRBG2 Damper motor Safety class ** 24 V AC/DC 230 V Motor Spring 500-630 BF 10 12.5 140 16 IP54 Other data see separate product information. ** Applies only when cable bushing is installed downward. Circuit diagram Tel +46 40 42 16 00, Fax +46 40 423 25 18, info@ekovent.se, www.ekovent.com 2017-10 3 (9)

Dimensioning diagram 1000 500 100 125 160 200 250 Total pressure drop Pa 100 50 10 30 40 50 60 315 400 60 50 5 40 30 L WA (db) 1 0,5 10 50 100 1000 10000 Air velocity m/s (damper area) Correction of sound power level in octave bands. L WAOK = L WA + K OK 90 EKO- Centre frequency (Hz) Octave band 63 125 250 500 1k 2k 4k 8k Correction, K OK 90 6 6 2-4 -8-10 -13-20 Tolerance ± db 2,5 1,5 1 1 1 1 2 Sound power levels, pressure drop and air flow measured on a fire/smoke damper according to ISO 5135. Standard deviation (tolerance) in accordance with EN ISO 3741:2010. Tel +46 40 42 16 00, Fax +46 40 424 25 18, info@ekovent.se, www.ekovent.com 2017-10 4 (9)

Installation accessories EKO- Plasterboard wall sleeve EKO-GIS Installation Installation kit EKO-MOV* * Included in EKO- delivery bracket 4 pcs For attaching duct Damper bracket 4 pcs For mounting fire damper 90 Wire mesh grille EKO-NRS Used for EKO- 100 250 Extension adapter EKO-FNS with wire mesh grille Used for EKO- 250 400 and for all sizes when mounting to sleeve in wall. T Wire mesh grille Wire mesh grille Tel +46 40 42 16 00, Fax +46 40 425 25 18, info@ekovent.se, www.ekovent.com 2017-10 5 (9)

Mounting instructions EKO- Mounting plasterboard wall sleeve EKO-GIS Mounting damper bracket EKO-MOV 1. Bend the damper bracket 90 at the groove. Sheet metal screw or steel pop rivet 1. Squeeze the EKO-GIS sleeve and insert it in the opening. 2. Attach the sleeve at the overlap with a sheet metal screw or pop rivet. 2. Stick the tip of the bracket between the sheet metal jacket and the insulation. 180 3. Bend the bracket 180 over the damper jacket. 4. Attach the bracket to the wall. Tel +46 40 42 16 00, Fax +46 40 426 25 18, info@ekovent.se, www.ekovent.com 2017-10 6 (9)

Mounting instructions EKO- Structural element wall of plasterboard or equivalent in fire-technical class EI 60. Sheet metal screw or pop rivet of steel Damper bracket Gap min 25 mm Gap min 25 mm O A+55 EKO- EKO-GIS wall sleeve bracket Fill with EKO-KER fire sealant or similar and seal with fire protection sealant. needs no fire insulation Mounting. See special mounting instructions for EKO-MOV mounting kit. 1. Make an opening in the wall equivalent to the nominal dimensions of the damper + 55 mm, i.e. with a gap of at least 25 mm all round. 2. Attach the EKO-GIS plasterboard wall sleeve to support the fire sealant between the structural element and the ventilation duct. The EKO-GIS is not needed for mounting in a concrete/brick wall. 3. Mount the damper in the wall, centre the damper in the opening and attach with the supplied EKO- MOV sheet metal brackets (damper brackets). 4. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 5. Mount the duct and fill the gap between the duct and the wall with fire sealant EKO-KER or similar and seal with fire protection sealant. 6. Mount the accompanying EKO-MOV sheet metal brackets (duct brackets). 7. The suspension devices for the damper and ducting must meet the requirements for the firetechnical class of the aperture. 8. In cases where the damper is mounted as a transfer air device or end plate, an EKO-NRS wire mesh grille or EKO-FNS extension adapter must be mounted. 9. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. NOTE! On damper EKO- 250 400 the extension adapter EKO-FNS with wire mesh grille must be used since the damper blade protrudes beyond the damper sleeve in open position. Tel +46 40 42 16 00, Fax +46 40 427 25 18, info@ekovent.se, www.ekovent.com 2017-10 7 (9)

Mounting instructions EKO- Load-bearing structural element wall or floor of concrete, brick or aerated concrete of fire-technical class EI 60. Sheet metal screw or pop rivet of steel Damper bracket Gap min 25 mm Gap min 25 mm O A+55 EKO- bracket Fill with EKO-KER fire sealant or similar and seal with fire protection sealant. needs no fire insulation Mounting. See special mounting instructions for EKO-MOV mounting kit. 1. Make an opening in the wall equivalent to the nominal dimensions of the damper + 55 mm, i.e. with a gap of at least 25 mm all round. 2. Mount the damper in the wall, centre the damper in the opening and attach with the supplied EKO- MOV sheet metal brackets (damper brackets). 3. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 4. Mount the duct and fill the gap between the duct and the wall with fire sealant EKO-KER or similar and seal with fire protection sealant. 5. Mount the accompanying EKO-MOV sheet metal brackets (duct brackets). 6. The suspension devices for the damper and ducting must meet the requirements for the firetechnical class of the aperture. 7. In cases where the damper is mounted as a transfer air device or end plate, an EKO-NRS wire mesh grille or EKO-FNS extension adapter must be mounted. 8. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. NOTE! On damper EKO- 250 400 the extension adapter EKO-FNS with wire mesh grille must be used since the damper blade protrudes beyond the damper sleeve in open position. Tel +46 40 42 16 00, Fax +46 40 428 25 18, info@ekovent.se, www.ekovent.com 2017-10 8 (9)

Mounting instructions EKO- Structural element wall or floor structure of fire-technical class EI 60. Suspension Ø A+55 EKO- EKO- EKO- Fire sealant* Fire sealant* 1. The duct system should be suspended and insulated in accordance with the fire resistance of the structural element in which the hole is made (EI 60). Insulation of the ventilation duct must be done in accordance with Installationsbrandskydd Ventilation Rör section 21.3.4 (ISBN: 978-91-633-1723-1) corresponding to the fire resistance of the structural element in which the hole is made (EI 60). NOTE! The insulation does not need to cover the damper. 2. Mount the damper in the duct. No gaps between the damper and a fire-containing structural element. Screw the damper to the duct with self-drilling screws. Check that the movement of the blade is not obstructed by the screws. 3. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 4. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. * Fire sealing must be done using an approved method that complies with the relevant firetechnical class, e.g. EKO-KER, EKO-GIS and fire protection sealant. Tel +46 40 42 16 00, Fax +46 40 429 25 18, info@ekovent.se, www.ekovent.com 2017-10 9 (9)