Direct-acting 3/2 way plunger valve

Similar documents
3/2-way Solenoid Valve, direct-acting, NC or NO

Direct-acting 2/2-way plunger valve

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

2/2- and 3/2-way solenoid valve for aggressive fluids

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Servo-assisted 2/2 way piston valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-way Rocker Solenoid Valve for pneumatic systems

2/2-way Solenoid Valve with servo diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Direct-acting 2/2- or 3/2-way pivoted armature valve

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

3/2-way Solenoid Valve for pneumatics

2/2-way Solenoid Valve for liquids and gases

2/2 or 3/2 way direct acting rocker solenoid valve

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Pneumatic control unit for decentralized automation of ELEMENT process valves

2/2 or 3/2-way Miniature Rocker Solenoid Valve

AirLINE and AirLINE Quick electrical/pneumatic Automation System

2/2-way Miniature Solenoid Valve

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

2/2 way Angle-Seat Valve for medium up to C, DN15-50

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

2/2-way Globe Valve for media up to +180 C, DN

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

2/2 or 3/2 way direct acting rocker solenoid valve

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Electrical position feedback for actuator sizes Ø mm

Cable Plug acc. to DIN EN , Form A

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Электромагнитные клапаны для пара Burkert

2/2-way Globe Valve for media up to +180 C, DN

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

2/2 and 3/2-way ball valve with pneumatic rotary actuator

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

2/2 or 3/2 way ball valve with pneumatic rotary actuator

The manifolds can be powered through various fieldbus systems, multipole or common terminals.

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

2/2-way servo assisted Solenoid Valve

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Type 6213 EV, 6281 EV

2/2- or 3/2-way- Rocker Solenoid Valve

INSERTION flow sensor for continuous flow measurement

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

Material pressure (bar) (Cv (US) kv x 1,2 Seat

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Technical Principles of Valves

Position Switches Series 8070/2

Position Switches Series 8060/2

2/2-way Diaphragm Valve, forged valve body, weld end and clamp connection, DN 8-100

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

2/2 Pressure operated valves

97105 Inline. Ordering information. Technical data. Accessories See page 5

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Solenoid coils VACF Type codes

Modular pneumatic valve unit

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Control Buttons / Switches for Panel Mounting Series 8003

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Электромагнитные клапаны для агрессивных и чистых сред Burkert

2/2-way Globe Control Valve, threaded port connection, DN 10-65

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Modular pneumatic valve unit

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Pneumatically operated zero dead volume T-Valve CLASSIC

Our policy is one of continued research and development. We therefore reserve the right

INSERTION flowmeter with paddle wheel, ELEMENT design

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Positive displacement flowmeter for continuous flow measurement

0322, 0324, Pilot Solenoid Valve, Plastic

Bürkert Select We make ideas flow

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

97100 NAMUR. Technical data

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

Transcription:

Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type 6014 can be combined with Service-friendly manual override Energy-saving impulse versions Type 2508 Type 6014 Type 2511 Type 2513 Cable Plug Multiple manifold (e.g. 6-fold) Cable plug Cable plug (ATEX Cat. 3 GD) Valve 6014 is a direct-acting plunger valve. The stopper and plunger guiding tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. A Bürkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold. The coils are moulded with polyamide or with chemically resistant epoxy. Pulse coils are available for the reduction of electrical power consumption during operation. Optional manual actuation enables quick commissioning and easy maintenance. In combination with a plug in accordance with DIN EN 17301-803 Form A, the valves satisfy protection class IP65. Stainless steel valves satisfy NEMA 4X. Circuit function C Circuit function D 3/2 way valve NC, outlet 2 relieved 3/2 way valve NO, outlet 2 normally pressurized Technical data Body material Seal material Medium Medium temperature Polyamide coil (FKM seal) Brass or stainless steel, polyamide (sub-base) FKM (EPDM on request) Neutral gases and fl uids (e.g. compressed air, town gas, natural gas, water, hydraulic oil, petrol). Suitable for technical vacuum -10 to +100 C (PA coil) to 120 C Epoxy coil Ambient temperature Max. +55 C Viscosity Max. 21 mm 2 /s Port connection G 1/8, G 1/4, sub-base (SFB) Operating voltage V DC, V/50 Hz, 230 V/50 Hz (other voltages on request) Voltage tolerance ±10% Duty cycle / single valve Assembly Electrical connection Installation Protection class Coil insulation class Coil material Orifice DN 1.5-2.5 100% continuous rating Intermittent operation 60% (30 min) or with 5 W coil (on request) DIN EN 175301-803 Form A for Cable Plug,Type 2508 (see Ordering chart for accessories) ATEX/IECEx version with 3 m moulded cable As required, preferably with actuator upright IP65 with cable plug, ATEX/IECEx junction box version and cable connection version NEMA 4x with cable plug 2508 or 2509 only for stainless steel versions (other versions on request ) Polyamide class B (Epoxy class H on request) Polyamide (Epoxy on request) 3/2 way, universal valve Circuit function T www.burkert.com p. 1/21

Technical data Power consumption Orifice Power consumption [mm] Inrush AC Hold AC (hot coil) DC hot / cold coil [VA] [VA] [W] [W] 1.5-2.5 17 8 8 / 9 Response times Orifice Response times AC and DC [mm] Opening [ms] Closing [ms] 1.5 10-15 15-20 2.0 10-15 15-20 2.5 15-20 10-22 Response times [ms]: Measured at valve outlet at 6 bar and +20 ºC. Opening: Pressure build-up 0-90%, to Closing: Pressure relief 100 to 10% Materials Locknut: St. st. (Thick-film passivated surface) (Brass version) Cable plug: PA (Polyamide) Flat seal: NBR Coil: PA (Polyamide) Epoxy (High temperature version) Sub-base: St. st. (Thick-film passivated surface) St. st. 1.4301 Spring: 1.4310 Stopper: 1.4105 Shading ring: Cu (brass version) Ag (stainless steel version) Plunger seal: FKM Spring: 1.4310 Magnetic core: 1.4105 Armature guide tube: 1.4303 O-rings: FKM Plunger seal: FKM Valve body: Brass Stainless steel 1.4305 (G 1/8") Stainless steel 1.4401 (G 1/4") p. 2/21

Dimensions [mm] Threaded version Sub-base version (SFB) 12 10 G1/8 27 18 ** 5.4 C 5.6 C 41 15 11.2 6.3 3.7 32 9 15 7 4x 4x8 deep A 32 35 * B 32.6 8 *** M4 29 F SW14 E Dimensions [mm] Version A B C Threaded without manual G 1/8 32 20.8 override G 1/4 46 26.8 Threaded with G 1/8 32 20.8 manual override G 1/4 46 26.8 Sub-base 32 14.3 Coil size E F 5 32 45 6 40 51 Utilisation in another circuit function Valves with circuit functions (WW) C, D and T are fitted with different springs. If used in some other circuit function, the permissible operating pressure may change (see table below). Valve Version Basic version DN Circuit function Max. operating pressure [bar] for valve application in circuit function A B C D T 1.5 C 16 22 16 2 2 D 2 2.5 2 16 2 T 10 16 10 6 6 2.0 C 10 14 10 1 1 D 1 1.5 1 10 1 T 6 10 6 4 4 2.5 C 6 9 6 0.7 0.7 D 0.7 1 0.7 6 0.7 T 3.5 6 3.5 2.5 2.5 Connections For the positions marked with *, ** or *** in the drawing, the connections are marked with the letters shown in the table above, depending on the circuit function. Unused connections in circuit functions A or B will be closed off with a blanking plug or cap nut. Circuit Connection Type function * ** *** A P blank off A B blank off B P C P R A D R P B T P R A see drawing on page 7 p. 3/21

Ordering chart for valves (other versions on request) 6014 Threaded valves with FKM seal, (class B) Delivered without cable plug (see accessories) Circuit function Orifice [mm] Port connection Kv value water [m 3 /h] 1) Pressure range [bar] 2) Effective coil power [W] per voltage / frequency 0/DC 0/50 230/50 Brass body C 3/2 way valve NC D 3/2 way valve, NO T 3/2 way Universal valve 1.5 G 1/8 0.07 0-16 8 125 329 125 331 125 332 2.0 G 1/8 0.11 0-10 8 125 333 125 334 125 336 G 1/4 0.11 0-10 8 125 348 126 138 126 140 2.5 G 1/8 0.16 0-6 8 125 341 125 340 125 342 G 1/4 0.16 0-6 8 126 142 126 143 126 145 1.5 G 1/8 0.07 0-16 8 126 195 126 196 125 355 2.0 G 1/8 0.11 0-10 8 125 357 125 358 125 360 G 1/4 0.11 0-10 8 126 198 126 199 126 201 2.5 G 1/8 0.16 0-6 8 125 363 126 202 126 204 G 1/4 0.16 0-6 8 126 205 126 206 126 208 1.5 G 1/8 0.07 0-7 8 126 150 126 151 126 153 with manual override C 3/2 way valve NC 2.0 G 1/8 0.11 0-10 8 125 337 125 338 125 339 G 1/4 0.11 0-10 8 125 349 126 147 126 149 D 3/2 way valve, NO 2.0 G 1/8 0.11 0-10 8 126 209 125 361 126 211 G 1/4 0.11 0-10 8 126 212 126 213 126 215 Stainless steel body C 3/2 way valve NC T 3/2 way, universal valve 1.5 G 1/8 0.07 0-16 8 126 216 126 217 126 219 2.0 G 1/8 0.11 0-10 8 126 220 126 221 126 223 2.0 G 1/4 0.11 0-10 8 126 2 126 225 126 227 1.5 G 1/8 0.07 0-7 8 126 228 126 229 126 231 1) Measured at +20 C, 1 bar 2) pressure difference 2) Measured as overpressure to the atmospheric pressure p. 4/21

Ordering chart for valves (other versions on request) 6014 Valves with FKM seal and sub-base body (SFB), (class B) Delivered without cable plug (see accessories) Circuit function Orifice [mm] Kv value water [m 3 /h] 1) Pressure range [bar] 2) Effective coil power [W] per voltage / frequency 0/DC 0/50 230/50 Brass body C 3/2 way valve NC 1.5 0.07 0-16 8 126 154 126 155 125 366 2.0 0.11 0-10 8 125 367 125 368 125 370 D 3/2 way valve, NO 2.0 0.11 0-10 8 126 161 126 162 125 383 with manual override C 3/2 way valve NC Polyamide body material C 3/2 way valve NC 1.5 0.07 0-10 5 126 403 126 404 126 406 1.5 0.07 0-16 8 126 157 126 158 126 160 2.0 0.11 0-6 5 126 407 126 408 126 410 2.0 0.11 0-10 8 125 371 125 372 125 374 1.5 0.07 0-10 5 126 390 126 391 126 393 with manual override C 3/2 way valve NC 1.5 0.07 0-10 5 126 396 126 397 126 399 1) Measured at +20 C, 1 bar 2) pressure difference 2) Measured as overpressure to the atmospheric pressure p. 5/21

Ordering chart for valves, impulse version (other versions on request) 6014 impulse valve with FKM seal material and brass body (class H) Circuit function C 3/2 way valve, output 2 exhausted Port connection Orifice [mm] Kv value water [m 3 /h] 1) Pressure range [bar] 2) Power consumption DC (hot/cold coil) [W] per voltage [V/] Brass body Threaded port G 1/8 1.5 0.07 0-16 7 209 280 209 284 Sub-base {SFB) 2.0 0.11 0-10 7 209 281 209 285 1.5 0.07 0-16 7 209 278 209 282 2.0 0.11 0-10 7 209 279 209 283 012/DC 0/DC 1) Measured at +20 C, 1 bar 2) pressure difference 2) Measured as overpressure to the atmospheric pressure Activation of the impulse version with inverse polarity operation The polarity is labelled on the valve Specifications Terminal connections - switch ON + valve will be opened (+) on terminal 2 and (-) on terminal 1 (see below) + switch OFF - valve will be closed (+) on terminal 1 and (-) on terminal 2 (see below) 1 2 Earth terminal The polarity is labelled on the valve - switch ON + + switch OFF - Impulse duration, min. 50 ms. Note: Only cable plug without circuitry should be used together with impulse version! p. 6/21

Materials for banjo version 1 2 3 4 5 6 7 8 9 Locknut Coil PA (Polyamide) Epoxy (high temperature version) Stopper 1.4105 Shading ring CU (brass version) Ag (stainless steel version) Armature guide tube 1.4303 Magnetic core 1.4105 Sub-base Spring 1.4310 Armature seal Steel (surface finish thick film passivated) (Brass version) Steel (surface finish thick film passivated) Stainless steel 1.4301 FKM 10 Valve body Aluminium 11 O-Ring FKM 12 13 14 15 Pressure connection P Pressure connection A Screw CuZn / 1.4301 Seal Usit ring (Aluminium/NBR ) 16 O-Ring NBR p. 7/21

Dimensions for banjo version 32 bei 2 W 40 bei 8 W 45 bei 2 W 51 bei 8 W G1/8 A SW19 A 10 55,4 11,7 G P M G1/4 31 L 45 G M L G 1/8 10 51 G 1/4 12 54 IXEF Banjo coupler, anodised aluminium banjo bolt p. 8/21

Ordering chart for banjo version (other versions on requests) All valves with FKM seal and manual override, delivered without cable plug Anodised aluminium banjo coupler, nickel-plated brass banjo bolt per voltage/frequency [V/Hz] Circuit function Pressure inlet P (banjo coupler) Service port A (banjo bolt) Orifice [mm] QNn value air [l/min] Material flange body Pressure range [bar] Power consumption [W] 0/DC 0/50 230/50 C 3/2 way valve NC G 1/4 G 1/8 1.5 75 PA 0-6 2 4 123 4 1 4 127 G 1/4 1.5 75 PA 0-6 2 4 118 4 119 4 122 G 1/8 2.0 120 Brass 0-10 8 4 113 4 114 4 117 G 1/4 2.0 120 Brass 0-10 8 4 103 4 104 4 107 Please note that the cable plug has to be ordered separately, see separate datasheet for Type 2508. Ordering chart for banjo version IXEF (other versions on requests) All valves with PA body, FKM seal and manual override, delivered without cable plug IXEF banjo coupler, anodised aluminium banjo bolt per voltage/frequency [V/Hz] Circuit function Pressure inlet P (banjo coupler) Service port A (banjo bolt) Orifice [mm] QNn value air [l/min] Material flange body Pressure range [bar] Power consumption [W] 0/DC 0/50 230/50 C 3/2 way valve NC G 1/8 G 1/4 1.5 75 PA 0-10 5 784 710 x x G 1/8 G 1/4 2.0 120 PA 0-10 8 784 706 784 707 784 709 G 1/8 G 1/4 2.5 174 PA 0-6 8 786 014 x 786 015 Please note that the cable plug has to be ordered separately, see separate datasheet for Type 2508. x on request p. 9/21

Materials for ATEX/IECEx m cable version Locknut: Stainless steel (surface finish thick film passivated) (Brass version) Cable: Polyolefin Copolymer electron beam crosslinked Coil: Epoxy Stopper: 1.4105 Shading ring: Cu (brass version) Ag (stainless steel version) Seal: FKM Spring: 1.4310 Magnetic core: 1.4105 Armature guide tube: 1.4303 O-Ring: FKM Sub-base: Stainless steel (surface finish thick film passivated) Stainless steel1.4301 Spring: 1.4310 Seal: FKM Valve body: Brass Stainless steel 1.4305 (G 1/8 ) Stainless steel 1.4401 (G 1/4 ) p. 10/21

Dimensions for ATEX/IECEx m cable version Threaded version Flange version (SFB) G1/8 F C 5.4 63 74 41 B H A 4x M4 x 8 deep D 32 35 E C 7 M4 5.6 SW14 Dimensions [mm] Version A B C D H Threaded G 1/8 32 20.8 32.6 8 G 1/4 46 26.8 49 12 Sub-base 32 14.3 32.6 Coil size E F 5 32 69 6 40 75 p. 11/21

Ordering chart for Ex m valves cable version 6014 valve, Ex m II T4, with FKM seal material and sub-base (SFB) connection with 3 m moulded cable approved for block mounting, ambient temperature from -10 C to +40 C Circuit function C Orifice [mm] Port connection 1.5 sub-base (SFB) 2.0 sub-base (SFB) Kv-value water [m 3 /h] Pressure range [bar] Body material Effective coil power [W] Voltage/ frequency [V/Hz] with manual override 0.07 0-10 PA 7 0/UC 278 651 230/UC 278 653 Brass 7 0/UC 278 655 230/UC 278 656 0.11 0-6 Brass 7 0/UC 278 658 230/UC 278 659 6014 valve, Ex m II T4, with FKM seal material and threaded connection with 3 m moulded cable approved for single mounting, ambient temperature from -10 C to +55 C Circuit function C T Orifice [mm] Port connection Kv-value water [m 3 /h] Pressure range [bar] Body material Effective coil power [W] Voltage/ frequency [V/Hz] without manual override with manual override 2.0 G 1/8 0.11 0-10 Brass 9 0/UC 278 637 278 645 230/UC 278 638 278 646 Stainless steel 9 0/UC 278 660 x 230/UC 278 661 x G 1/4 0.11 0-10 Brass 9 0/UC 278 639 278 647 230/UC 278 641 278 649 Stainless steel 9 0/UC 278 662 x 230/UC 278 663 x 2.5 G 1/8 0.16 0-6 Brass 9 0/UC x x 230/UC x x G 1/4 0.16 0-6 Brass 9 0/UC 278 643 278 673 230/UC 278 644 x 1.5 G 1/8 0.07 0-7 Brass 9 0/UC 278 650 x 230/UC x x Stainless steel 9 0/UC 278 664 x 230/UC 278 665 x G 1/4 0.07 0-7 Brass 9 0/UC x x 230/UC x x Stainless steel 9 0/UC 278 666 x 230/UC x x x on request The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 C, 100 C T5, T6 85 C), minus 5 K. ATEX and IECEx approval for coils with fixed cable outlet ATEX: PTB 14 ATEX 2023 X IECEx: IECEx PTB 14.0049 X II 2G Ex mb IIC T4 Gb Ex mb IIC T4 Gb II 2D Ex mb IIIC T135 ºC Db Ex mb IIIC T135 ºC Db p. 12/21

Materials for ATEX/IECEx m junction box version Locknut: Stainless steel (surface finish thick film passivated) (Brass version) Stopper: 1.4105 Shading ring: Cu (brass version) Ag (stainless steel version) Core seal: FKM Spring: 1.4310 Magnet core: 1.4105 Junction box: aluminium Coil: Epoxy Flange: Steel (surface finish thick film passivated) Stainless steel1.4301 Spring: 1.4310 Armature guide tube: 1.4303 O-Ring: FKM Core seals: FKM Valve body: Brass Stainless steel 1.4305 (G 1/8 ) Stainless steel 1.4401 (G 1/4 ) p. 13/21

Dimensions for ATEX/IECEx m junction box version F J I 68 G1/8 C 5.4 41.3 62.2 73.6 B D H 4x M4x8 deep A 32 35 51 E SW14 Dimensions [mm] Version A B C D H Threaded G 1/8 32 20.8 32.6 8 G 1/4 46 26.8 49 12 Flange 32 14.3 32.6 Coil size E [mm] F I J 5 32 120.3 20.5 69 6 40 126.3 23.5 70.7 p. 14/21

Ordering chart for Ex m valves junction box version 6014 valve, Ex m II T4, with seal material FKM and flange connection (SFB) Junction box for block mounting available, ambient temperature from -10 C to +40 C Circuit function C Orifice [mm] Port connection 1.5 sub-base (SFB) 2.0 sub-base (SFB) Kv value water [m 3 /h] Pressure range [bar] Body material Coil effective power Voltage/ Frequency [V/Hz] with manual override 0.07 0-10 PA 7 0/UC 288 562 230/UC 288 563 Brass 7 0/UC x 230/UC x 0.11 0-6 Brass 7 0/UC x 230/UC x x on request 6014 valve, Ex m II T4, with seal material FKM and threaded connection with junction box only for single mounting available, ambient temperature form -10 C to +55 C Circuit function C T Orifice [mm] Port connection Kv value water [m 3 /h] Pressure range [bar] Body material Coil effective power Voltage/ Frequency [V/Hz] without manual override with manual override 2.0 G 1/8 0.11 0-10 Brass 9 0/UC 288 470 288 491 230/UC 288 490 288 566 Stainless steel 9 0/UC 288 488 x 230/UC 288 497 x G 1/4 0.11 0-10 Brass 9 0/UC 288 471 288 475 230/UC 288 516 288 519 Stainless steel 9 0/UC 288 486 x 230/UC 288 500 x 2.5 G 1/8 0.16 0-6 Brass 9 0/UC 288 572 x 230/UC 288 505 x G 1/4 0.16 0-6 Brass 9 0/UC 288 498 288 476 230/UC 288 575 288 479 1.5 G 1/8 0.07 0-7 Brass 9 0/UC 288 511 x 230/UC x x Stainless steel 9 0/UC x x 230/UC x x G 1/4 0.07 0-7 Brass 9 0/UC x x 230/UC x x Stainless steel 9 0/UC 288 489 x 230/UC 288 506 x The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 C, 100 C T5, T6 85 C), minus 5 K. x on request ATEX and IECEx approval for the assembly of the coil and the junction box ATEX: EPS 16 ATEX 1046 X IECEx: IECEx EPS 16.0021 X II 2G Ex eb mb IIC T4 Gb Ex eb mb IIC T4 Gb II 2D Ex mb tb IIIC T130 ºC Db Ex mb tb IIIC T130 ºC Db p. 15/21

Ex-Cable glands (polyamide version included in delivery / surcharge applied for brass nickel plated version Ex Approvals Photo Description Certification Identification Item no Drawing Brass. nickelplated, 6-13 mm PTB 04 ATEX 1112 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68, 773 278 TL 29-37 mm L 6 mm D 20 SW mm E 27 mm TL 36-45 mm Polyamide, 7-13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 773 277 L 10 mm D 20 SW mm E 28 mm Special tool to turn the junction box (not included in delivery) Photo Description Set SC02-AC10 Special wrench Service Manual 293 488 p. 16/21

Materials for ATEX/IECEx ia Locknut: Stainless steel (surface finish thick film passivated) (Brass version) Cable plug: PA (Polyamide) Seal: NBR Spule: Epoxid Sub-base: Stainless steel (surface finish thick film passivated) Stainless steel1.4301 Stopper: 1.4105 Shading ring: Cu (Messing version) Ag (Edelstahl version) Seal: FKM Spring: 1.4310 Magnetic core: 1.4105 Armature guide tube: 1.4303 O-Ring: FKM Seal: FKM Valve body: Brass Stainless steel 1.4305 (G 1/8 ) Spring: 1.4310 p. 17/21

Dimensions for ATEX/IECEx ia [mm] Threaded version Flange version (SFB) 12 10 G1/8 27 18 32 41.4 9 15.1 20.8 14.5 5.4 11.2 32 32.6 8 4x M4x8 deep A 32 35 M4 27.5 SW14 40 23.3 6.3 3.7 7 6.5 29 51 Electrical data Type of protection EEx ia IIC T6 acc. to PTB-No. Ex-96.D.2010 PLC + 30 ma V DC Barrier/ Isolation module > 9.3 V DC + Note: The valve is designed to operate on V DC outputs through an intermediary intrinsically safe apparatus (isolating block or barrier).. Function values for switching valve at +20 C at +55 C Minimum switching current 30 ma 30 ma Nominal resistance coil 310 Ω 360 Ω Minimum terminal voltage 9.3 V 10.8 V Max. allowable values acc. to the certificate of conformity Ui 28 V li 120 ma Pi 1,1 W Ambient temperature +60 ºC at T6 +75 ºC at T5 p. 18/21

Technical data - ATEX/IECEx -ia Response times Response times Opening [ms] Closing [ms] 20 22 Response times [ms]: Measured at valve outlet at 6 bar and +20 ºC Opening: Pressure build-up 0 to 90%, Closing: Pressure drop 100 to 10% Ordering chart - ATEX/IECEx -ia 6014 valve; Ex ia II T6 with FKM seal material only for approved single mounting, cable plug acc. to DIN EN 175301-803 Form A, ambient temperature from -10 C to 60 C for T6, -10 to -75 C for T5 Circuit function Orifice [mm] QNn-value air [l/min] Pressure range [bar] Body material Port connection with manual override C 0.9 30 Vac. to 10 Stainless steel Bürkert sub-base (SFB) 144 540 G 1/8 147 226 Brass Bürkert sub-base (SFB) 147 227 G 1/8 146 214 The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 C, 100 C T5, T6 85 C), minus 5 K. Explosion-proof approvals ATEX: PTB 01 ATEX 2101 0102 II 2G Ex i IIC T6 Gb II 2D Ex i IIIC T85 ºC Db PTB IECEX12.0040 Ex ia IIC T6 Gb Ex ia IIC T80 C Db Ordering chart for accessories Cable plug Type 2508 acc. to DIN EN 175301-803 Form A Circuit Voltage / frequency without circuitry 0-250 V 438 574 p. 19/21

Ordering chart for Manifolds Accessory parts Features Single manifold in aluminium black anodized Multiple manifold in aluminium Hole spacing A [mm] Total length B [mm] Hole spacing C [mm] 005 020 2 valves 57 65 005 023 3 valves 90 98 005 286 4 valves 123 131 005 287 5 valves 156 164 57 005 035 6 valves 189 197 57 005 038 8 valves 255 263 90 005 386 10 valves 321 329 90 005 764 Covering plate with plugs and O-ring, for closing off unused valve positions 005 630 Manifolds in Brass or stainless steel on request Manifold mounting With manifold mounting, please comply with the permissible duty cycle (5 W models with 100% continuous rating or 8 W model with 60% duty cycle). The pressure port for the manifold is designated with P (R), and the outlet port with A (B). Only connect together ports with the same designation. 2/2 way valves of Type 6013 can be operated together on a manifold with 3/2 way valves of Type 6014, circuit function C (not D or T!) if the operating pressures agree according to the rating plates. The manifolds can also be expanded if the valve functions are taken into consideration. Caution! Unused, open valve ports must be closed off with covering plates (see ordering chart above). p. 20/21

Ordering chart for accessory Cable plug Type 2508 according to DIN EN 175301-803 Form A Fixing screw Circuitry Voltage/ Frequency Flat seal None (standard) 0-250 V AC/DC 008 376 with LED 12 - V AC/DC 008 360 with LED and varistor 12 - V AC/DC 008 367 with LED and varistor 200-0 V 008 369 with inverter 1) V DC on request further versions see datasheet Type 2508 1 The inverter plug includes an electronic which is specially adapted for an electrical control with 3 wires Input 3 wire technology, common "-" polarity, two split "+" polarity. Output suitable for impulse model for Type 6013/6014 The delivery of a cable plug includes the flat seal and the fixing screw. For other cable plug versions, see separate datasheet Type 2508. Click on the box More info. and you will come to our website for this product where you can download the datasheet. Cable plug Type 2513 acc. to DIN EN 175301-803, Form A Meets the requirements of ATEX category 3 GD BN BU GNYE Cable length [mm] [in mm] 12000 260 893 5000 260 892 3000 260 891 300 260 890 Materials Epoxy coil according to Form A Seal material EPDM Voltage Non-standard voltages Port connection With banjo nut Approvals ATEX, UL, CSA Additional Orifice: 1.2 mm, 3.0 mm To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alterations Christian Bürkert GmbH & Co. KG 1606/9_EU-en_00895091 p. 21/21