CARB Compliance Solutions. Options for meeting the California Air Resources Board requirements for Transport Refrigeration Units.

Similar documents
CARB Compliance Solutions. Options for meeting the California Air Resources Board requirements for Transport Refrigeration Units.

CARB Compliance Solutions. Options for meeting the California Air Resources Board requirements for Transport Refrigeration Units.

TriPac e. Electric Auxiliary Idle Reduction and Temperature Management System

T-600. Self-powered unit for straight trucks with the latest in scroll compressor technology.

Precedent Single-Temp

Precedent Single-Temp. A complete lineup for trailers that offers more choices, greater efficiency and precise temperature control.

Precedent Multi-Temp. Precedent multi-temp takes the premier trailer platform in the industry and optimizes it for food distribution.

Precedent Multi-Temp Precedent multi-temp takes the premier trailer platform in the industry and optimizes it for food distribution.

Owners Manual: Flow Through Filter (FTF) System

TriPac. Hybrid Auxiliary Idle Reduction and Temperature Management System

TriPac e. Electric Auxiliary Idle Reduction and Temperature Management System

MEET THE NEW T-80 SERIES

Owners Manual: Flow Through Filter (FTF) System

UT-1200X. Unmatched Capacity and Reliability for Undermount Applications

SLR Series. All-New, Ultra-Low Profile Rooftop HVAC System featuring ComforTEK for Shuttle and School Bus Applications.

Genuine Thermo King Filters. Maximum filter effectiveness.

Genuine Thermo King Filters. Maximum filter effectiveness.

Genuine Thermo King Filters. Maximum filter effectiveness.

Precedent Multi-Temp. The most environmentally sensitive multi-temp units we ve ever made offer improved efficiency and a lower cost of ownership.

SG Generator Set Undermount. Re-defining efficiency and sustainability

TriPac. Hybrid Auxiliary Idle Reduction and Temperature Management System

History of Innovation

TriPac Evolution. The industry-leading APU that delivers lower operating costs and superior driver comfort.

Areas of the State not meeting Federal Air Quality Standards. Fleet Rule for Transit Agencies

V-500 Series Enhanced performance with optimal control

TriPac Evolution. The next generation APU that delivers lower operating costs and improved serviceability.

Air Quality Mandates Affecting the Caltrans Fleet Caltrans Division of Equipment Sacramento, CA June, 2009

Power Management Products. A complete family of power storage, power generation and electrical load management solutions.

GreenTRAP Diesel Particulate Filter

Metro and you, building together.

EXCEL. Medium Temp Display Case. Far More Energy Efficient. Greater Merchandising Capacity. Enabling excellence in food retailing.

Diesel Retrofit Technologies Legacy, Current and Upcoming. Charlie Cox Tuesday, June 17, 2008

Generator Set Range SG-3000 & SG-4000 Series

T Series. The most reliable HVAC system for transit is now better than ever.

ON-ROAD HEAVY-DUTY TRUCK APPLICATION

built for the next generation Cat

ThermoLite Solar Panels. The most advanced solar charging solution for every need under the sun.

Strategic Plans for Sustainable Ports: The Northwest Ports Clean Air Strategy Experience. Amy Fowler, Puget Sound Clean Air Agency

Precedent Multi-Temp. The most environmentally sensitive multi-temp unit we ve ever made offers improved efficiency and a lower cost of ownership.

Diesel Rules Compliance Update. Presented by Sean Edgar, Project Manager

DRIVING TOWARDS A CLEANER FUTURE

2017 DieselWise Indiana Solicitation for Projects. Shawn Seals DieselWise Indiana Administrator

Technology Choices. New Bus Purchases Fleet Make-up Engine Models & Years Driver Education & Support Duty Cycles Fuel Use & Storage

m b e E M I S S I O N S E N G I N E

Questions/Comments During Workshop

TriPac Envidia. All-electric APU with the longest run time in the industry for superior driver comfort.

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen GENERATION 1 ENGINE Manual Transmission

RYDER SELECTCARE MAINTENANCE. Offering the Most Flexibility, Choice, and Control in the Industry

FREQUENTLY ASKED QUESTIONS TIER 4 INTERIM / STAGE IIIB PRODUCTS

SCAQMD Rule 1470 Impact on Diesel Generator Installations

built for the next generation

2013 Tier 4 Compliant. High capacity and reliability. Low fuel consumption and noise. Let Vector units energize your bottom line.

Review of the SMAQMD s Construction Mitigation Program Enhanced Exhaust Control Practices February 28, 2018, DRAFT for Outreach

Truck and Bus Regulation National Pavement Expo West

Webasto Service 360. The best approach to an optimal solution is all-round.

A Case Study On the Compliance of the Heavy Duty Diesel Vehicle Regulation

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen GENERATION 3 ENGINE

Portable Equipment Registration Program (PERP) and the Portable Engine ATCM. What is Portable?

Generators. Automatic backup power for everyday life. Know you re protected with a Honeywell Home Generator

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen GENERATION 1.2 ENGINE

Verified Retrofit Technologies and Product Offerings. Northeast Diesel Collaborative February 26, 2015

CALIFORNIA S COMPREHENSIVE PROGRAM FOR REDUCING HEAVY- DUTY VEHICLE EMISSIONS

MARINE VESSEL REPOWER APPLICATION

SG-3000 Series Generator Sets

Advanced Solutions for Meeting EPA Tier 4 Engine Emission Regulations On H HD and Reachstackers

Reciprocating Service Compressors

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT AGRICULTURAL PUMP ENGINE COMPONENT

Olson-EcoLogic Engine Testing Laboratories, LLC

of Verifi RYPO Filter

IMPORTANT INFORMATION

Future of Trucking Symposium 2010 Engine & Emissions Technology

CARB Diesel Vehicle & Equipment Regulations

MOVE TO ZERO. Setting new standards for performance and reliability with near-zero emissions.

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT AGRICULTURAL PUMP ENGINE COMPONENT

Subject: Emissions Recall 23U3 Emissions Modification Available for Model Year Volkswagen 2.0L TDI

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen GENERATION 2.2 ENGINE

State of California AIR RESOURCES BOARD EXECUTIVE ORDER DE

B-Series Superior all-electric Temperature Control for chilled products

The Problems We Deal With. From a Fleet Management Perspective.

Transportation. Actuators, Pedals and Sensors

Clean Air Construction Standard Draft for Public Comment November 5, 2018

Important Information About Your L TDI Audi

Yanmar Showcases the comprehensive Diesel and. Gas Engine Line-up at BAUMA 2019

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT AGRICULTURAL PUMP ENGINE COMPONENT

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen

MOVE TO ZERO. Setting new standards for performance and reliability with near-zero emissions.

Clean Cities CWI Product Update. Jerry Johnson CWI Western Regional Manager May 18, 2017

Diesel Retrofit Programs to Clean-up In-Use Vehicles - U.S. Experience

TNV Series Common Rail. Final Tier 4 19kW to 56kW WATER-COOLED DIESEL ENGINES. EPA Tier 4 (19-56kW) EU Stage IIIB (37-56kW)

DIESEL TO DIESEL ENGINE REPOWER OPTION

Precedent. The all-new trailer platform that delivers double-digit fuel savings and offers compliance choices that don t compromise performance.

Alternative Fuel Vehicle Program and Garbage Trucks

EPA Tier 4 Final: Cleaner Equipment, Cleaner Air

Redefining Efficiency. B6.7 For Truck Applications.

Emissions Compliance, For Every Diesel Application.

Redefining Efficiency B6.7 For Truck Applications.

Better. At Work. Cummins 2013 ISX12 For Vocational And Day Cab Truck Applications.

Exhaust After-Treatment System. This information covers design and function of the Exhaust After-Treatment System (EATS) on the Volvo D16F engine.

Evolution Of Tier 4 Regulations & Project Specific Diesel Engine Emissions Requirements

Precedent. The all-new trailer platform that delivers double-digit fuel savings and offers compliance choices that don t compromise performance.

Transcription:

CARB Compliance Solutions Options for meeting the California Air Resources Board requirements for Transport Refrigeration Units.

CARB - Are You Ready? The California Air Resource Board (CARB) has passed a series of regulations called the Airborne Toxic Control Measure (ATCM) that will affect owners/operators of transport refrigeration units (TRUs) which operate in California. Compliance is required by December 31, 2008 for 2001 and older engine model year transport refrigeration units Thermo King offers a variety of options to help your business comply with CARB regulations, including new units, Tier 4i engine kits and LETRU-compliant Diesel Particulate Filters The TRU ATCM will require in-use TRU and TRU genset engines that operate in California to meet in-use performance standards that vary by horsepower range. These standards can be met by: Using an engine that meets the required engine certification standard Equipping the engine with the required level of verified diesel emission control strategy Using an Alternative Technology Thermo King is the Green Leader Thermo King offers industry-leading products and solutions that enable businesses around the world to reduce energy consumption and costs and decrease harmful environmental emissions. The symbol indicates a feature that delivers a significant environmental advantage over previous models or the competition. Understanding the CARB TRU regulation CARB Requirements CARB is targeting 7 year old Transport Refrigeration Units for particulate emissions reduction. Compliance required for 2001 and older TRU beginning December 31, 2008. Compliance is based on engine model year and occurs 7 years after the model year. Example: 2002 engine model year equipment must meet LETRU standards by December 31, 2009. Example: 2003 engine model year equipment must meet ULETRU standards by December 31, 2010 CARB TRU ATCM California Air Resources Board Transport Refrigeration Unit Airborne Toxic Control Measure Regulation within CARB that applies to in-use diesel engines VDECS Verified Diesel Emissions Control System Approved methods for complying with ATCM for reducing diesel emissions PM Particulate Matter is soot from the diesel exhaust Equipment upgraded to LETRU status must be upgraded to ULETRU status in an additional 7 years. There are several different methods for becoming compliant with the CARB regulation. Operators may need to register with CARB for an identification number by January 31, 2009. This is required for California based TRUs and optional for out-of-state based TRUs that operate in California. CARB posts the complete regulation, updates, FAQ, and other information at the following website: http://www.arb.ca.gov/diesel/tru.htm Key Definitions DPF Diesel Particulate Filter (Exhaust Filter) LETRU Low Emission Transport Refrigeration Unit At least 50% particulate matter reduction, Level 2 VDECS ULETRU Ultra-Low Emission Transport Refrigeration Unit At least 85% particulate matter reduction, Level 3 VDECS PDPF Passive Diesel Particulate Filter (Thermo King s LETRUcompliant device)

Engine Model Year What is your CARB Compliance Schedule In-use Compliance Year 07 08 09 10 11 12 13 14 15 16 17 18 19 20 2001 & older L L L L L L L U U U U U U 2002 L L L L L L L U U U U U 2003 U U U U U U U U U U U 2004 U U U U U U U U U U 2005 U U U U U U U U U 2006 U U U U U U U U 2007 U U U U U U U 2008 U U U U U U 2009 U U U U U 2010 U U U U 2011 U U U 2012 U U 2013 U* L= LETRU Low Emission Transport Refrigeration Unit U= ULETRU Ultra-Low Emission Transport Refrigeration Unit *<25 hp engines only, >25 hp engines do not require upgrades for 2013 model year. Compliance Method and Recommendations Compliance Method PDPF: Install exhaust filter to meet LETRU Requirements Engine: Retrofit TRU with a new engine Electricity: Use electric standby to eliminate diesel engine operation at a facility New Equipment: Purchase new equipment Fleet Management: Maintain 7 year trade cycle Fleet Management: Move affected equipment out of California Alternative Fuels: Use B100, CNG, Fuel Cells, or other CARB approved fuels Recommendation Cost effective method of achieving compliance without adverse impact to service intervals or engine efficiency Ideal solution to achieve compliance while reducing maintenance costs Appropriate for units originally equipped with electric standby, must equip facility with plugs for each unit New units are EPA compliant. CARB regulation requires upgrades to units 7 or more years old Keeps equipment in compliance without upgrades, retrofits, or fuel changes May be possible for national companies with routes or operations that do not require travel to California Difficult to use because of additional service requirements, record keeping, and availability of fuels

Thermo King offers seve Compliance Passive Diesel Particulate Filter Product Characteristics Level 2 Diesel Particulate Filter 50% Reduction - LETRU Compliant Kit includes DPF, Insulation, Back Pressure Gauge and Control Box Installed by Thermo King trained technicians Engine Validation Requires a pre-installation checkout to determine engine efficiency. An engine with excessive oil consumption (over 1Q in 50hrs) may result in excessive backpressure and a fouled PDPF. If the engine does not meet this threshold, the PDPF cannot be installed. Fuel Injectors must have been serviced within the last 3000 hours, otherwise, the injectors must be cleaned or replaced. An engine with poor injector efficiency may result in excessive backpressure and a fouled PDPF. Installation Engine validation tests require 1-2 hours of labor and 24 hours of runtime. PDPF installation requires 3-5 hours of labor (5-6 for Super II models). Kits are complete with all parts required outside of routine shop supplies. Operation The Thermo King PDPF requires no fuel additives or plug in regeneration it automatically regulates engine speed to develop sufficient heat to clear the filter as buildup occurs. There should be no impact on fuel economy or TRU operating characteristics. Service Engine requires fuel injector servicing every 3000 hours. The PDPF does not require scheduled maintenance, although if fuel injectors are replaced or the engine begins to burn oil, the PDPF may need to be removed for cleaning. Warranty 4 years or 2600 engine hours. See full text in PDPF manual. Applications Kits are available to fit all SB and Super II models with Isuzu SE or Yanmar engines through 2002. Be sure to order both the PDPF and the install kit. Product Part # PDPF (PDPF only) 120912 SB Install Kit (install kit only) 100400 Super II Install Kit (install kit only) 100391 PDPF installs in place of the muffler on SB units, externally on Super II (shown)

ral Options Tier 4i Engine Retrofit Kits Product Characteristics Installation: Engine installation typically requires 10-12 hours. Most kits are complete with all parts required outside of routine shop supplies. Some kits require software chip or drive plate change. Operation: Operates normally Service: Normal engine service guidelines apply Available for these applications SB, SB III, SB III King of the Road, SB 100, SB 190, SB 200 / 300 / 400, SB Classic, Super II, Super II, Super II 190 Engine Retrofit Kits Part Numbers Tier 4i Engine... 1010363 Install Kit SB... 100397 Super II... 100398 Coupler Large Shaft Compressor... 772506 Small Shaft Compressor... 772358 Software Must use the right version for the controller Controller Required Software Part # TGVI V1091 400896 MPIV V0472 400671 Note: Solution for MPIV with V03xx software currently in development. These units will need additional modifications. MPIV MT V2041 400946 MPIV V06xx not necessary MPVI V40xx not necessary Upgrade to EMI-3000 Extended Maintenance Interval Filters Engine Retrofit Kits come equipped with EMI-3000 oil filters. Upgrade your fuel and air filters for maximum benefits! Reduces maintenance costs Reduces clean up and disposal costs Reduces environmental impact with less spillage and less waste Extends engine life EMI-3000 Fuel Filter 100325 EMI-3000 Air Filter 119299

New Thermo King Equipment Compliance Options Purchase New Units - Purchase options are available through IR Financial Services and other organizations Trade In - Thermo King offers trade or outright purchase bids on used equipment. What can a New Unit do for you? Meet all CARB regulations Increase efficiency and uptime Decrease maintenance and fuel consumption Offer you the latest technology Finance your new equipment with Ingersoll Rand Financial Services Thermo King and Ingersoll Rand Financial Services offer very competitive financing solutions for all types of customers from owner/operators to the largest fleets in North America. You can choose from a wide range of smart, flexible financing products to fit your unique and changing business needs. Programs include lease and loan financing for refrigeration units with trailers or trucks. For fleet customers, we also offer a Cold Air Lease Program for refrigeration units alone. Benefits of Financing through Ingersoll Rand Financial Services Improved Cash Flow Flexibility Full Range of Financing Vehicles Operating Income is easier to Forecast Convenience of One-Stop Shopping Competitively Priced Financing Balance Sheet Benefits Professional Service Cold Air Lease Program A transportation fleet s needs can be complex. Sometimes, keeping the same reefer and trailer together for the fleet s trade cycle is less than optimum. Thermo King and Ingersoll Rand Financial Services can help you meet your complex needs, helping you control your expenses and extend the life of your trailers by offering financing solutions for the refrigeration units only. Thermo King Truck Units with Electric Standby An alternative strategy for complying with the CARB regulations is to use electric standby at facilities where 3 or more refrigeration units operate. An electric standby equipped reefer can make short duration stops without plugging in when two or less TRUs are present at a time and the delivery stop is 30 minutes or less. This is a good option for truck fleets making deliveries to convenience stores and restaurants. See CARB regulation and FAQ for more information on electric standby record keeping and operation requirements. See your Thermo King dealer for more information on new truck refrigeration units with Electric Standby.

Tier I Tier I engines have stickers generally installed on the unit frame rail and valve cover Engine Identification CARB regulations are based on engine model year. Below are model identification photos for Tier I and Tier II models. Pre-Tier engines (1998 and older) did not have sticker identification 2000 Tier I Isuzu 2003 Tier I Yanmar Tier II Tier II engines have stickers installed on the front of the oil pan and valve cover Tier II Yanmar sticker location 2007 Tier II Yanmar Expert Service and Support are as close as this sign. Enjoy the support of the Thermo King Dealer Network. Over 200 factory-authorized service centers nationwidefind one nearby at www.thermoking.com

Providing equipment and services to manage controlled-temperature environments for food and other temperature-sensitive products, our Climate Control Technologies sector encompasses both transport and stationary refrigeration solutions. Our product brands include Thermo King, a world leader in transport temperature control systems, and Hussmann, a manufacturer of refrigeration and food merchandising equipment. www.thermoking.com www.hussmann.com www.ingersollrand.com TK 53678-11-PL (2-08) 2007 Ingersoll-Rand Company Printed in U.S.A. on Recycled Paper