Integra / Summer Breeze

Similar documents
SWIMMING POOL CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS

CLEAN POWER TM CPS Series Operator s Manual

INSTALLATION AND OPERATING INSTRUCTIONS

MECHANICAL UNDER COUNTER 150 CONCEALED CISTERN (BTW)

Domestic Water Supply Pressure Pumps

General Warranty Terms and Conditions

General Installation Instructions for Valves and Gates

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

GENERAL SPECIFICATIONS AND PRODUCT DESCRIPTION

16 Inch Hanging Pendant Barn Light

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

Scania Used Vehicle Extended Driveline Warranty

GWA BATHROOMS & KITCHENS WARRANTY PERIODS

PVI 60KW, PVI 82KW, PVI 95KW

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

DOMINIQUE MKII wall hung vanity 900mm. Wall Hung Vanity 900mm (Left Hand Bowl) Cabinet Only - Front View Cabint Only - Side View

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

DOMINIQUE MKII SEMI RECESSED vanity

FOR NEW ZEALAND. T-604 WASTE DISPOSER B. HYDRAULIC CHARACTERISTICS &TECHNICAL SPECIFICATIONS. DECLARATION OF COMPLIANCE

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

WARRANTY LIMITED WARRANTY, COMMAND PRO. . Print

Kompensator External Low Voltage Heating Cable System

List Of Product(s) Installed

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Motion Sensing Coach Light

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

Installation and Operating Instructions for

Installation Instructions Application Fits 2016 Tesla Model X The Law Removable License Plate Frame X7340

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

OWNER S MANUAL Please read this manual before operating your power supply

WARNINGS, CAUTIONS AND NOTES

TPAK Series COOLANT PUMP

Land Rover Warranty INTRODUCTION DATA PROTECTION STATEMENT

ROCA THE GAP BACK TO WALL TOILET SUITE

Issue 3. Description: ROBINHOOD TAP PULL-OUT SERIES Model Numbers: TPO1200. Model may vary slightly from image pictured

OWNER'S MANUAL MYCRO 8

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

WARRANTY AND SERVICE BOOKLET

ROCA KHROMA TOILET SUITE

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

ALAPE METAPHOR UNDERCOUNTER BASIN

Key Installation Points. Table of Contents

Euro Lightweight Wheeled Walker

FADE Series Wall Axial Fans

MV Series Motors Operation & Parts Manual

Electromagnetic Particle Brakes Model: PRB-H

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER

StormPro BA Series Sump Pump

60 Watt Industrial LED Low Bay Light

INSTALLATION AND OPERATING INSTRUCTIONS

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

8000 / 10,000 / 12,000

Compact Scales. Software Revision V1.25 & above

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

Single Leg AM/CM 20, 24 and 30

EF SERIES MOTORS OPERATION & PARTS MANUAL

Albatross. Series. Ceiling Fan Instruction Book. Models: MAFM MAFML2 MAFML3 MAFML5

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

RU BMS Power Supply and Battery Management System Owners Guide

HANDS FREE FOOT & KNEE OPERATED TAPWARE

Wall Mounted Mini Split Air Conditioner

SPEED KEY After the fan has started, press to change fan speed in sequence of: Low - Medium - High. The corresponding indicator will illuminate.

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

SIGMA75 PNEUMATIC CONCEALED CISTERN (BTW)

SIGMA PNEUMATIC CARE BUTTON

10 Ch Peak & Hold Injector Driver PN

Ford Warranties THE FORD EXPRESS NEW VEHICLE WARRANTY - WARRANTY STATEMENT 1

OWNER S OPERATING MANUAL

ROUND REMOTE BUTTONS AND PLATE (IN-WALL)

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

ANTI VANDAL TAPWARE. Installation Instructions CONCEALED SPINDLE (CS) SERIES SCHOOL PATTERN (VP) SERIES TRADITIONAL/INSTITUTIONAL (IN) SERIES

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC


RANGE HOODS USER INSTRUCTIONS

Active Evacuation System (AES)

VERSION 2017 V.1.0

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1

JUMP STARTER OPERATOR S MANUAL RA1900

QUALITY MISTING PUMPS

INSTALLATION & OWNERS MANUAL. PowerGlide. PowerGlide

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Smart By Design Flexible By Nature

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

LOUDSPEAKER OWNER'S MANUAL

AIRGROUP PRICE LIST

MODEL NUMBER: BD-132 USER GUIDE

HALLMARK INDUSTRIES INC

OWNER S OPERATING MANUAL

Jackhammer Trolley JHT

AWE S-FLO Carbon Intake System Mini F5X. AWE website here

Wireless Key Tracker. Locate Lost Keys instantly

User Manual HomeGrid 5000 HD

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Description: Baja Designs Features:

Transcription:

Technical Specifications Integra / Summer Breeze 2007-8 Domestic Ducted Evaporative Air Conditioners Integra VSS55, VSM65, VSL75

Introduction TECHNICAL SPECIFICATIONS Page 2

Table of Contents WARRANTY... 4 PRODUCT RANGE... 6 Integra Units... 6 Summer Breeze Units... 7 PRODUCT SPECIFICATIONS... 8 Unit Construction... 8 Product Weight & Dimensions... 8 Fan Specification... 8 Fan Motors... 8 Pumps... 9 Evaporative Pads... 9 Water Management... 9 Electrical Systems... 9 PRODUCT DIMENSIONS... 10 WIRING DIAGRAM... 11 TECHNICAL SPECIFICATIONS Page 3

Warranty (Australia Only) Warranty IMPORTANT: Please read this warranty information and complete the Dealer/Product information on the following page. KEEP this with your original purchase documents for any claim under warranty. WARRANTY PROCEDURES: Firstly refer to your owners manual to ensure you have followed the correct operating procedures of your product, and refer to the trouble shooting guide to assist solving any problems you may have. 1. Read this warranty statement carefully before you request warranty service as items relation to installation are not covered by this appliance warranty. 2. A proof of product purchase must be provided for warranty service, to validate the appliance is within the manufacturer s warranty periods. 3. This warranty is only for products and associated original controls for Climate Technologies manufactured product. 4. Only an authorised Climate Technologies service provider must carry out warranty service. Climate Technologies provides the following Manufacturers warranty additional to all implied warranties and other statutory rights which you may have under the Trade Practices Act and similar State & Territory Laws, subject to the following terms and conditions. TERMS AND CONDITIONS: Conditions to warranty Subject to the exclusions noted, Climate Technologies warrant the product for the period as prescribed in the table following this statement to be free from Inherent defects in materials and workmanship for functional and structural components. This product is only valid if the product is operated in accordance with the manufacturers instructions The appliance must not be modified or changed in any way. Your proof of purchase MUST be produced before free service will be provided. Traveling time and mileage are included within 30km of either your authorised Climate Technologies dealer or service provider s premises. Customers in areas other than the above are responsible for any traveling time and mileage required to carry out warranty repairs. The product must be installed by a qualified person in the manner prescribed by local & statutory regulations and to the manufacturer s specifications. Service within the terms of this warranty will be recognised where we are satisfied that the appliance or part was supplied within the relevant time limits. Documents of purchase and Dealer/Installer information will assist in this process. Product fitness for purpose and overall system design / sizing is solely the responsibility of the dealer / installer. This includes but is not limited to heat load calculations, air flow, system balancing, humidity, water quality etc. The product must be installed in an easily and safe accessible area for service, appliances installed in areas not easily and safely assessable, costs will be borne by the owner for access equipment should maintenance be required. DIY installation Warranty If the product has been installed as a DIY, a supply part only warranty will apply. Parts only will be supplied free of charge on the return of the faulty part and the owner will be responsible for all labour charges incurred for the part to be fitted by a qualified person. Labour warranty as prescribed in the following table is void in this situation. Remote Location Warranty If the product has been installed outside the Climate Technologies service network, a supply part only warranty will apply. Parts only will be supplied free of charge on the return of the faulty part and the owner will be responsible for all labour charges incurred for the part to be fitted by a qualified person. Labour warranty as prescribed in the following table is void in this situation. TECHNICAL SPECIFICATIONS Page 4

Warranty (Australia Only) EXCLUSIONS TO WARRANTY. Consumable items subject to wear and tear such as filter pads, drive belts and bearings are not covered by this warranty. Components used as part of the installation such as grilles filters, ducting, fittings, zone motors and consumer services pipe work are warranted from your place of purchase and not covered by this warranty. Damage caused by elements such as wind, rain, lighting, floods etc along with power spiking and brownouts are not considered defective material or workmanship and as such are not considered warranty. No responsibility will be accepted for outside elements such as pests, animals, pets and vermin that may cause damage to the unit. Harsh environmental situations such as salt air that may cause cabinet damage / rusting can not be considered warranty. The manufacturer does not accept liability or any claims for damage to building contents, carpet, walls, ceilings, foundations or any other consequential loss either direct or indirect. Damage resulting from, power spikes, incorrect operation, incorrect installation, and incorrect maintenance is also not covered. All warranties are NOT transferable. Conditions where warranty may be void. If there is no certificate of compliance for plumbing, electrical or refrigeration as required by State & Territory Laws. Climate Technologies reserves the right to refuse service on non-compliant installations. The defective operation of the appliance that is due to failure of electricity, gas, water or refrigerant gas supplied. Defects are caused by neglect, incorrect application, abuse or by accidental damage of the appliance. An unauthorised person has attempting to repair the appliance. A situation arises referenced in the trouble-shooting guide. A charge will be made for work done or a service call where there is nothing wrong with the appliance. WARRANTY PERIODS Unit Components RESIDENTIAL COMMERCIAL Parts Labour Parts Labour Corrosion on Cabinet 25 3 2 2 Structural Guarantee 10 3 2 2 ** All other components 3 3 1 1 ** Filter pads are a consumable item and therefore are not covered by the above warranty periods. TECHNICAL SPECIFICATIONS Page 5

Product Range Product Range Integra Units Part Number Model 6060032GYE 6060032RDE 6060032BEE 6060032GNE 6060032CHE VSS55 Grey W/Seal DV VSS55 Red W/Seal DV VSS55 Beige W/Seal DV VSS55 Green W/Seal DV VSS55 Chocolate W/Seal DV 6060036GYE 6060036RDE 6060036BEE 6060036GNE 6060036CHE VSS65 Grey W/Seal DV VSS65 Red W/Seal DV VSS65 Beige W/Seal DV VSS65 Green W/Seal DV VSS65 Chocolate W/Seal DV 6060038GYE 6060038RDE 6060038BEE 6060038GNE 6060038CHE VSS75 Grey W/Seal DV VSS75 Red W/Seal DV VSS75 Beige W/Seal DV VSS75 Green W/Seal DV VSS75 Chocolate W/Seal DV Accessories 5000005 RF Remote Control 6050064 Touchpad 5001915 Comms Cable Only 5011915 10m Extension Cable 5001675 Antenna TECHNICAL SPECIFICATIONS Page 6

Product Range Summer Breeze Units Part Number Model 6060032GY 6060032RD 6060032BE 6060032GN 6060032CH VSS55 Grey DV VSS55 Red DV VSS55 Beige DV VSS55 Green DV VSS55 Chocolate DV 6060036GY 6060036RD 6060036BE 6060036GN 6060036CH VSS65 Grey DV VSS65 Red DV VSS65 Beige DV VSS65 Green DV VSS65 Chocolate DV 6060038GY 6060038RD 6060038BE 6060038GN 6060038CH VSS75 Grey DV VSS75 Red DV VSS75 Beige DV VSS75 Green DV VSS75 Chocolate DV Accessories 5000006 LV Programmable 5000006 LV Manual Summer Breeze 5001915 Comms Cable Only 5011915 10m Extension Cable 6001343 Enviroseal 550 x 550 6021344 Enviroseal 800 x 550 TECHNICAL SPECIFICATIONS Page 7

Product Specifications INTEGRA / SUMMER BREEZE 2007/8 Product Specifications Description Unit Construction Cabinet Base Venturi Screws Motor Mounting arms Product Weight & Dimensions Integra VSS50 VSS55 VSM60 VSM65 VSL70 VSL75 Injection Moulded Polypropylene Injection Moulded Polypropylene Injection Moulded Polypropylene Stainless Steel Pressed Metal - Powder Coated Shipping Weight 61 65 80 Operating Weight 84 92 109 Weight excluding fan and louvres 29.5 30 31.5 Cabinet Dimension 1184 Sq 1192 Sq 1192 Sq Cabinet Height Front 683 790 1047 Cabinet Height Back 573 681 937 Duct Discharge Sizes 558 x 558 558 x 808 Dropper Duct Requirement 550 x 550 550 x 800 Fan Specification Fan Type V16 (5 Blade Axial) V16 (10 Blade Axial) ***** Sound Pressure Levels - 1 metre Db(A) 64.5 66 66.5 68 65.5 66.5 Fan Diameter 493mm Fan Pitch 28.0 o 31.0 o 37.0 o Hub Fastening Fan Motors Type Taperlock Variable Speed Motor Description 855BPVA-A11 855BQVA-A16 855-BRVA-B13 Watts In (@ Maximum Rated Load) 970 1040 1540 Watts Out 600 750 950 Volts / Phase / Hz 240/1/50 Current - High Speed Amps @ 80pa 1.6 1.9 3.0 3.1 4.5 4.8 RPM - High Speed 1260 1410 1360 1400 1190 1350 RPM - Low Speed (Minimum set) 500 500 500 500 500 500 Overload Protection Shaft Diameter Bearings Internal Auto Reset Thermal Overload I /2" (12.7mm) Sealed Ball Capacitor 15μƒ 25μƒ 25μƒ Capacitor Rating P2 P2 P2 TECHNICAL SPECIFICATIONS Page 8

Product Specifications SPECIFICATIONS Description Pumps Type Shaft Body Motor Wiring Specifications Motor Overload Protection Bearings Strainer Material Flow Rate L/M Watts In Watts Out Current RPM (Nominal) Integra VSS50 VSS55 VSM60 VSM65 VSL70 VSL75 JRM E/P38 Stainless Steel ABS Plastic Encapsulated Shaded Pole Thermal Overload / Auto Reset D.F. Ball Polypropylene Variable to 24 litres per minute x 1.2 Metre high 50w 40w 0.35 amp 2300 rpm Volts / Phase / Hz 240/1/50 Evaporative Pads Type Celdek 5090 (45 o x 45 o ) Size 755 x 365 755 x 480 755 x 736 Thickness 90 mm Open Area Total 1.01 M² 1.35 M² 2.09 M² Air Velocity (High) 1.4m/s 1.7m/s 1.5m/s 1.7M/s 1.2m/s 1.3m/s Water Management Float Valve Float Valve - Water Pressure Range 1/2" BSP Cistern Float Valve 100-500 kpa Tank Capacity - Litres 17.5 Over flow fitting Dump Valve Dump Mechanism - Min. / Max. Dump Valve Solenoid Electrical Systems RF Remote Control LV Programmable LV Touchpad LV Manual 50mm combination drain & overflow 40mm or 19mm 100 to 500 Kpa 100-500 Kpa Continuous Rating 240V 50Hz 10amp variable speed controlled 240V 50Hz 10amp variable speed controlled 240V 50Hz 10amp variable speed controlled 240V 50Hz 10amp variable speed controlled ***** Dba ratings are internal tests measured at 1 metre radial from the unit tested in semi reverberant room. Units currently under independent NATA laboratory testing. TECHNICAL SPECIFICATIONS Page 9

PRODUCT DIMENSIONS INTEGRA / SUMMER BREEZE 2007/8 Product Dimensions Model A B C D E F G H VSS 55 573 683 1184 1184 560 560 VSM 65 681 790 1192 1192 560 660 VSL 75 937 1047 1192 1192 560 810 TECHNICAL SPECIFICATIONS Page 10

Wiring Diagram INTEGRA / SUMMER BREEZE 2007/8 Wiring Diagram TECHNICAL SPECIFICATIONS Page 11

Issue B September 2007