Specifications. Minimum Build Up Volts 3.5vac. Voltage Regulator

Similar documents
Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

SE2000BX Static Exciter

XR500B Universal Voltage Regulator

MP24 Motorized Potentiometer

AFM500X Automatic Flashing Module

MOP1224HD Heavy-Duty Motorized Potentiometer

SE450 Static Exciter Module

ABF40 Automatic Battery Flash Unit

XR500D-277V Special Voltage Regulator

XR500D Universal Voltage Regulator

AFM500X Automatic Flashing Module

DC250i. Voltage Regulation: Specifications

VoltPro VP4 Automatic Voltage Regulator

PC1000B Phase Control

VoltPro VPBF8 Automatic Battery Flashing Module This Manual Covers Both VPBF8-12 and VPBF8-24 Models

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR

XC4 Commercial Series

XR5B Hz Specialty Series Universal Voltage Regulator

REVISION A (FROM SERIAL

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

XR5C Specialty Series Universal Voltage Regulator

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Electric Utility Contact Information Indiana Michigan Power

Unit 32 Three-Phase Alternators

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

INSTALLATION & OWNER'S MANUAL

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

GENERATOR INTERCONNECTION APPLICATION

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

2009 MFJ ENTERPRISES, INC.

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

PSNH INTERCONNECTION REQUEST

5001TCP SPEED CONTROLLER

WF-5110R True Sine Wave Inverter

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

VR-182. Series Voltage Regulators

Boston Gear Ratiotrol DC Motor Speed Control

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

OPERATING INSTRUCTIONS

MANLEY LABORATORIES, INC. MANLEY REFERENCE JUNIOR DAC OWNER'S MANUAL 20 BIT DIGITAL TO ANALOG CONVERTER

Boston Gear Ratiotrol

Instruction Manual. Installation Operation Maintenance. KCR 760 Voltage Regulator

MX431 Generator Automatic Voltage Regulator Operation Manual

WF-5110R True Sine Wave Inverter

A39 UNIVERSAL SCR CHARGER

ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

EG3002. Electronic Engine Governor Controller User Manual

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

5001TCP SPEED CONTROLLER

10 Year Limited Warranty

Portable Generator Familiarization & Troubleshooting Guide Section 3 Generator Diagnostics and Adjustments

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

HLY-1111 HEAD TEMPERATURE GAUGE

OBAE, OBAEXU, ON BOARD Battery Chargers

TABLE OF CONTENTS STANDARD FEATURES

BZ Products Inc. U.S.A.

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

ME AGS Auto Gen Start System for Coach Generators. Operator s Manual.

Harris IRT Enterprises Digital Resistance Tester Model XP

Electric Motor Controls BOMA Pre-Quiz

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

AUTO CHARGE D PUMP PLUS

BLACKBIRD OWNER S MANUAL

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

180w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-1800HC14

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Power. On Your Terms.

INDUSTRIAL GENERATOR SERVICE

INSTALLATION & OPERATION MANUAL

JAMP-350HR15. Installation and Operation Instructions. 350W ROKKER XXR Amplifier Kit For Harley RoadGlide/ Ultra/Ultra LTD.

Power Inverter 400 MW Owner s Manual

BP1204 INSTALLATION/OWNER'S MANUAL

Installation of TPS-28D Universal Lighting Power Supply

Warranty Request Forms for US Customers ONLY

WF-5100 Series True Sine Wave Inverters

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

600 Series Troubleshooting Guide for C651 and C654 Alternators

OBE, OBEXU, ON BOARD Battery Chargers

Product Description. Installation Instructions. Fig. A

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

A1P OPERATING MANUAL

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Transcription:

SE1500AX Static Exciter The SE1500AX Static Exciter is a 100amp complete static exciter designed to replace older rotary, electronic and magnetic amplifier types of exciters. Installation of the SE1500AX is a simplified process that involves only four main connections to the generator. The SE1500AX is complete with fusing, snubber circuits and build up provisions. Specifications Voltage Input 208/240vac 1ø Output Voltage Range.75 to 105vdc Maximum Output Amps 100adc Minimum Field Resistance 1.05Ω Operational Frequency 50/60hz Regulator Accuracy +/-.25% Voltage Response 1/2 cycle Regulation Flat response / FF Maximum Burden 10.5kva Internal Fusing 100 amps Minimum Build Up Volts 3.5vac Physical Size 10 x 20 x 8in Weight 18lbs Voltage Regulator XR500D

To generator rotor slip rings F- F+ AC1 AC2 208/240vac from generator stator * TB1 A B C D E F 5Ω @100w 20 amps @800v Regulator * Off / On B+ B- Battery Flash (if used) Use isolated battery only! Remote Adjust 100kΩ Stability Adjustment Internal voltage Adjustment * For parallel operation, see diagram 2 Interconnection Diagram for the SE1500AX Static Exciter

Installation Instructions Installation of this product should performed only by an experienced electrical generator service technician. Failure to do so could result in damage to the electrical generator and or the voltage regulating system. Follow all safety procedures while installing this system. Special Note: Slip ring and brush problems are the most common problem when installing a replacement static exciter. Many times, the failure of the system that is being replaced was caused by contact problems with the brushes and slip rings. Do not attempt to install this static exciter on an application that has evidence of brush and ring problems. Check brushes and slip rings of the generator. Make sure that the brush faces do not show signs of arcing, lines or groves, burned spots, pitting or rough surfaces. Inspect the slip rings for grooves, discolored areas, and pitted or rough areas and for surface trueness. Make sure that the brush springs are working and have the correct tension. Check the brushes for length. Connect up the SE1500A as per the diagram included with this instruction sheet. It is recommended that a circuit breaker or manual disconnect is placed in the incoming ac power circuit to AC1 and AC2. Check all connections and make sure that the regulator is turned off and the main disconnect is open. Start up prime mover and bring up to rated speed. Allow the unit to run for a few minutes to allow the brushes and slip rings to seat. Make sure that the internal voltage control is turned counter clockwise about 10 turns. Close main disconnect and turn the regulator switch on. Adjust the internal voltage control clockwise until the voltage output of the generator begins to rise (the adjustment pot is 25 turns) and set to the desired voltage setting Place the generator on line and observe for proper operation.

Connections for parallel operation of SE1500AX Static Exciter Shown below are the AC input connections for reactive droop parallel operation. Diagram 2 Generator 5a CT Aø Bø Cø 208/240vac from generator stator 6Ω @100w Unit / Parallel SW Regulator Off / On AC1 AC2 TB1-C TB1-D SE1500AX Interconnection Diagram for the SE1500AX Static Exciter

Installation form It is very important that you fill out this form completely when installing a voltage regulator. This form serves as a history record on the application. This form also contains the information needed by Power-Tronics, Inc., for repair and troubleshooting of any product you may be having problems with. Product Serial Number Date of Installation Other options Type of Generator Model # Brush type [ ] Brushless [ ] AC Stator Information Wired for Volts Phase Hz Generator Configuration: Lead Exciter/Rotor Information Exciter field resistance Ω @ F+ / F- Ω Exciter field volts vdc @ Slip Rings Ω Description of problem with product or generator Your phone number Your fax number Your email address Name: Ship to Address: Ship to City, State, Zip:

PRODUCT WARRANTY Power-Tronics, Inc., assumes no liability for damages due to incorrect voltage or other voltage related damages resulting from either output of the generator or input to the generator exciter system. These problems should be protected with external devices provided by the customer such as fuses, surge suppressors, over/under voltage and frequency controls. Power-Tronics, Inc., warranties only parts and workmanship of this product for a period of 2 years from the original date of purchase from Power-Tronics, Inc. Under warranty, Power- Tronics, Inc. will replace, exchange or repair the defective product without labor or parts cost to the customer. Remaining warranty of the original product will be transferred to the replaced or repaired product. To obtain warranty, a copy of the original purchase receipt must be sent in with the defective product, which clearly shows the purchase date and serial number of the defective part. A repair request form must be sent in with the product before repairs will begin. You can obtain this form through contacting Power-Tronics, Inc.. Send repairs to: Power-Tronics, Inc., 2802 Cobbler Ln., Kerrville Texas USA 78028. Send in repairs only by UPS or FedEx. Do not send in repairs by U.S. mail. Any one of the following conditions will void the warranty:! Overheating of the power supply resistor on the printed circuit card.! Overheating of the SCR or freewheeling diode.! Physical damage to the printed circuit card, housing or components.! Unauthorized repair or alteration of printed circuit card.! Conductive or corrosive contamination of the circuit card.! Removal of our company identification from the product.! Removal of any conformal coating of the printed circuit card or components.! Overheating of foil on the printed circuit card.! Inappropriate or infeasible application.! Installation by a non-professional electrical generator service technician.! Damage caused by excessive vibration.! Use on any external device other than manufactured by Power-Tronics, Inc. No other warranty is expressed or implied.