Further information: Berriman Associates Model 850P.2 Owners Manual

Similar documents
MODEL 950C-NP-UV Installation and Owners Manual

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

EXT DUCTLESS FUME HOOD

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

SPH General Manual 400 Series

EXT HEPA/CARBON FUME HOOD

FAN POWERED HEPA FILTER UNIT

HARDWARE KIT INSTALLATION GLOVES

MINISTICK TM UV Germicidal Ultraviolet Light

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

User s Manual and Operating Instructions

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

110 Volt/12 Volt Portable Inflator

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

12 Volt Heavy-Duty Air Inflator

Operating Instructions for PAC800 Battery Charger

21", 33", 45", & 61" Installation & Operation Manual

OL100 VENTILATED DUMP STATION REFERENCE MANUAL. TM Coolidge Hwy. Oak Park, Michigan

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

Operating Manual PFB-2500

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

UV-AIRE AIR PURIFYING SYSTEM

Installer s Manual. PCO/UV N-Duct Model

Submersible Pond Pump with UV 800 Gallons Per Hour

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

60 Watt Industrial LED Low Bay Light

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

RED23305 Owner s Manual

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

ProAir Heat Exchangers XR20, XR29, XR47 & XR60

SAVE THESE INSTRUCTIONS

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

16 Inch Hanging Pendant Barn Light

OmniAire Portable Air Cleaner OA1200PAC

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE

CSA CERTIFIED Conforms to UL 507

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

2-Pack Indoor Simulated Dome Security Cameras

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

8" - 12" Hydraulic Steel Squeeze Off Tool

Owner s Manual Phoenix Guardian HEPA System

INSTALLATION INSTRUCTIONS

Omniaire 1000V Instruction Manual-8/05

PHOENIX MINI-GUARDIAN

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS

Safety, Installation and Service Manual Models 1952, 1953 & 1972

User s Manual and Operating Instructions

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

StormPro BA Series Sump Pump

TOBi PI Wi-Z. Performance Indicator and Event Logger. Quick Installation Guide

Model 8144NC Fresh Air Ventilator

Wood Chipper Model C550M Operator's Manual

Angle Grinder Holder

shadow focus floodlight SFS-300 INSTRUCTIONS

Owner s Manual Phoenix Guardian HEPA System

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Integrated Heating System

Owner s Manual Phoenix Mini-Guardian HEPA System

OmniAire 2200C Operations and Maintenance Manual

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

COLT CELL BATTERY CHARGER Installation and Operating Instructions

Model G14SD Vapor Management System

Owner s Manual Phoenix GuardianR

Inline & 90 Live Swivels Fax:

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Adjustable Shop Stool with Backrest

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Pressurized oil drain for collection of used lubricants and anti-freeze.

12V Oil Extractor Pump

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

INSTRUCTIONS PARTS LIST

Rapid Flow Induction Dodge Cummins 5.9L 52101

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

AQUA2000 From O3PURE

Installation Power Management Unit Battery Cables and Battery Harness

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

INSTALLATION TEMPLATE

2-Pack Indoor/Outdoor Simulated Security Cameras. Owner s Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

FADE Series Wall Axial Fans

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Mechanical Physician Scale Installation & Operation Instructions PN

Transcription:

Model 850P.2 Owners Manual

Thank you for purchasing the Model 850P.2 medical grade air purification system (APS), one of the finest air cleaning devices in the world. In order to ensure optimizing the unit s effectiveness and safe use, please read this Owners Manual in its entirety before installing and operating the Model 850P.2. SPECIFICATIONS: Height: 67 Width: 26 Depth: 20 Weight: Construction: Electrical: Air Flow: Pressure Gauge: 225 lbs. 18 gauge Steel 120 Volt/60 Hz / Single Phase, 1.9 A 850 cfm max.; Variable Low 0-10 WC REPLACEMENT PARTS: PART NUMBER DESCRIPTION QUANTITY 20201-30 20 x 20 x 1 Pleated Prefilter 2 (30% ASHRAE) 24483-99 19 ¾ x 43 ¾ x 3 ½ 1 Gel Seal Certified HEPA Filter (DOP) With Anodized Aluminum frame TMSUV22 22 UV Lamp 4 All filters and UV lamps come factory installed and should not be removed until replacement is required. WARNING: This device utilizes UV technology. As a result, direct contact with UV radiation must be avoided. Direct UV radiation will burn eyes. The Model 850P.2 is an electrical appliance that can not be exposed to rain or used near or in water. Model 850P.2 - NP-UV Manual v. 3 page 2 of 7

UNPLUG UNIT BEFORE ANY SERVICE WORK IS PERFORMED INSTALLATION: The Model 850P.2 is a portable air system designed to be moved into a room and used to create negative pressure or clean and recirculate room air. It is equipped with a detachable power cord to prevent the cord from being pulled too hard and exposing live wires. If the cord becomes frayed or damaged in any way, contact your dealer for a replacement cord. The unit is shipped with the Recirculation Top installed and the Negative Pressure Top separate from the cabinet body. The tops can easily be changed by removing the screws securing the top to the upper cabinet. NEGATIVE PRESSURE Wheel the unit into the room in which negative pressure is desired (after ensuring air flow requirements). Make sure the unit is equipped with the Negative Pressure Top (flat top with a 12 hole). In order to keep the unit out of the way and assure against disturbing the duct connection, it is recommended that the unit be located against a wall. Twelve inch round exhaust duct should be connected to the top using a collar on the top of the unit and vented to the exterior of the room/building through a window, wall, or dedicated sanitary air duct. RECIRCULATION OPTION To utilize the Model 850P.2 as a recirculation unit, simply make sure the recirculation top is installed (top with slots for air exhaust), wheel the Model 850P.2 into the desired location, and plug it in. TO ENSURE PROPER AIR FLOW PATTERN PLEASE MAKE SURE THE TOP IS INSTALLED VENTING THE AIR UPWARDS AND OUTWARDS TOWARD THE FRONT OF THE UNIT. After installation in either of the above-mentioned manners, the unit need only be turned on to the desired speed setting. CREATING NEGATIVE PRESSURE To create negative pressure, the CDC requires that exhaust flows be 10% greater than the supply air entering the room, but no less than 50 Model 850P.2 - NP-UV Manual v. 3 page 3 of 7

cfm. For example, a room with 150 cfm of supply air is required to have at least 200 cfm of exhaust air. The supply air should be measured to establish the incoming cfm. The return air grille for the HVAC system should be blocked off to prevent untreated air from returning into the general ventilation system. A 12 round duct should be connected to a collar at the top of the unit, and vented to the exterior of the building through a wall, window, or dedicated sanitary air duct. Please be advised that the CDC does allow the exhausted air to be returned to the general ventilation system when it is not possible to vent the air outside, but this is the least desirable alternative. MOTOR/BLOWER: MAINTENANCE The blowers are motorized backward curved AC impeller types and are selected for continuous operation. Maintenance is not required. PREFILTERS: The life of the Prefilters will depend on the ambient conditions within the room from which the air is being drawn. Average Prefilter life is 1-6 months, depending on the amount of use and the application. PREFILTER REPLACEMENT: When changing filters, we recommend the use of gloves and a mask, but standard operating procedures for the facility should always be followed. Used filters should be placed in plastic bags, sealed, and treated according to your standard state, local or facility s disposal procedures. The Prefilters are removed through the air intake grille. prefilters: To change the 1. Unscrew the six screws located in the protective grille and remove it. 2. Next, slide the Prefilters out from the Protective Grille (being sure not to disrupt and trapped dust). 3. Dispose of the old Prefilter as per State, local or facility SOP. Model 850P.2 - NP-UV Manual v. 3 page 4 of 7

4. To install a new Prefilter, simply slide it into the protective grille. Reinstall the protective grille in the correct configuration. UV LAMPS The UV lamps are rated to run 9,000 hours, but can last longer. A UV indicator light is located on the control panel, and it monitors the functioning of the UV lamps. Upon installation, the indicator should shine. When the UV lamps need to be changed, the indicator light will go out. UV shields are also attached to the intake grille to help ensure that direct exposure to UV radiation is avoided. DO NOT REMOVE THE UV SHIELDS FROM THE GRILLE OR OPERATE THE UNIT WITHOUT THE GRILLE AND SHIELDS IN PLACE. FAILURE TO DO SO COULD RESULT IN DIRECT EXPOSURE TO UV LIGHT. UV LAMP REPLACEMENT: UNPLUG UNIT BEFORE ANY SERVICE WORK IS PERFORMED WARNING: ALL POWER MUST BE SHUT OFF BEFORE REMOVING THE HEPA FILTER. DIRECT EXPOSURE TO UV RADIATION WILL BURN EYES. Once the intake grille is removed (as noted above), carefully remove the end of the UV lamps from their holders and pull the out from the socket. Installing the new lamps is done by reversing the removal process. Note: pins fit into socket in one direction. When installing UV lamps be careful not to touch the glass with bare hands, as skin oils will block UV output, making them less effective. WARNING: DO NOT RUN THE Model 850P.2 WITHOUT THE GRILLE/UV SHIELDS INSTALLED ON THE UNIT. FAILURE TO DO SO COULD CAUSE DIRECT EXPOSURE TO HARMFUL UV RADIATION. CERTIFIED HEPA FILTER: The life of the HEPA filter will depend on the ambient conditions within the room from which the air is being drawn. Average HEPA filter life is 1-3 years, depending on the application. The Digital Differential Pressure Monitor measures the differential pressure across the HEPA filter. It should be used to accurately determine when the HEPA Filter needs to be changed. Pressure readings should always be logged when new HEPA filters are installed. Model 850P.2 - NP-UV Manual v. 3 page 5 of 7

When to change HEPA filter: HEPA FILTER REPLACEMENT: When the differential pressure reading is twice the original reading after installing a new prefilter. When changing filters, we recommend the use of gloves and a mask, but standard operating procedures for the facility should always be followed. Used filters should be placed in plastic bags, sealed, and treated according to your standard disposal procedures. 1. The HEPA filter is removed through the air intake grille. Unscrew the six bolts located in the protective grille and remove it and the Prefilters. 2. Next, removed the UV lamps as outlined above. 3. The HEPA filter is held in place via two holding bars, so these need to be removed and the HEPA carefully uninstalled and disposed of as per facility SOP. 4. To install the HEPA, mount the HEPA filter into the module with the knife edge in the cabinet centered inside the gel seal track of the filter. DO NOT TOUCH THE HEPA MEDIA AS IT IS VERY FRAGILE AND WILL TEAR VERY EASILY. While carefully holding the HEPA into place (it may be easier to hold into place by actually pushing on the bars), install the HEPA holding bars and tighten until snug with the wing nuts. Be sure not to over-tighten as this could strip the bolts or damage the filter. 5. Replace the UV lamps, Prefilter, and perforated grille and handtighten the grille screws (DO NOT OVER-TIGHTEN) Model 850P.2 - NP-UV Manual v. 3 page 6 of 7

Limited Liability Warranty All products are warranted by Manufacturer to be free from defects in materials and workmanship for a period of five (5) years after shipment from its factory, provided the buyer demonstrates to the satisfaction of Manufacturer that the product was properly installed and maintained in accordance with Manufacturer s instructions and recommendations and that it was used under normal operating conditions. This warranty is limited to the replacing and/or repairing by Manufacturer of any part or parts which have been returned to Manufacturer, with Manufacturer s written authorization and in which Manufacturer s opinion are defective. Parts not manufactured by Manufacturer but installed by Manufacturer in equipment sold to the buyer shall carry the original manufacturer s warranty only. The buyer shall pay for all transportation charges, any and all sales and use taxes, duties, imports, or excises for such part or parts. Manufacturer shall have the sole right to determine whether defective parts shall be repaired or replaced. This warranty does not cover any customer labor charges for replacement of parts, adjustments or repairs, or any other work unless such charges shall be assumed or authorized in advance, in writing, by Manufacturer. This warranty does not cover any replaceable items such as filters or lamps, or any products which in the judgment of Manufacturer, has been the subject to misuse or negligence, improper handling or which has been repaired or altered outside Manufacturer s factory in any way, which may have impaired its safety, operation or efficiency, or any product, which has been subject to accident. This warranty shall be null and void if any part not manufactured or supplied by Manufacturer for use in any of its products shall have been substituted and used in place of a part manufactured or supplied by Manufacturer for such use, without authorization in advance, in writing by Manufacturer. There are no warranties, other than those appearing on the acknowledgement form including no warranty of merchantability or fitness for a particular purpose, given in connection with the sale of the goods sold hereunder. The buyer agrees that his sole and exclusive remedy, and the limit of Manufacturer s liability for loss from any cause whatsoever, shall be the purchase price of the goods sold hereunder for which a claim is made. No warranty or affirmation of fact, expressed or implied, other than as stated in LIMITED LIABILITY WARRANTY above is made or authorized by Manufacturer. Model 850P.2 - NP-UV Manual v. 3 page 7 of 7