Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Similar documents
Product Data. 42D Ducted Fan Coil Air Conditioners cfm

BAC / BHC Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers

Complete HVAC Capability

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

GENERAL ELECTRIC FAN COIL UNITS

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

FCVC Series VERTICAL FAN COILS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

BHH Product Specifications

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

CAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Product Data. 40RUA/40RUS 6to30TonDirectExpansion 7.5to30TonChilledWater Packaged Air- Handling Units FEATURES/BENEFITS

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Hi-Performance Series Fan Coil Technical Catalog

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

Commercial Blower Coil Air Handlers

EQUIPMENT TECHNICAL SUBMITTAL FOR APPROVAL DATE SUBMITTED APPROVED AS NOTED: NOT APPROVED PLEASE RESUBMIT

Vertical Floor Fan Coil Unit (Model FW)

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Tons BTU/h S.E.E.R* E.E.R** HSPF

Concealed Ducted Split Series R22

FN Fan-Coil Units High-Performance, Horizontal

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Air Handling Unit Fan Selection Guide

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

R-22, 13 SEER 60 Hertz

Modular Variable Speed Air Handlers

D M S 760 C01 A A 1 1

Residential Packaged Geothermal Heat Pump

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

WE MAKE INDOOR AIR BETTER

Horizontal Series Fan Coil Technical Catalog

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

WATER SOURCE HEAT PUMPS

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

The World Leading Air-conditioning Company

#7 Stock Cabinet Fan/Coils

FMU4X, FMC4X FMU4Z, FMC4Z

Typical Applications. Horizontal Installation

PCB COMMERCIAL SERIES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Vertical Hi-Rise Fan Coil Unit (Model FS)

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

ËÕߪ Õ» ç åé. 50BY/BL Series. Single-Package Cooling Units 90, ,500 BTUH. World's No.1 Air Conditioning Expert

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Heating and Air Conditioning

Transcription:

Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of motors, from 1 / 4 to 3 hp, eliminates oversizing Wide range of coil options for 2-pipe or 4-pipe system Optional DX coils with expansion valve and distributor Single and three-phase electric heat, (1.0 to 40 kw) STANDARD 42BH UNIT 42BH UNIT WITH ELECTRIC HEAT Features/Benefits The 42BH fan coil unit provides year-round comfort air conditioning with central station operating economy. A variety of coil options reduces first cost Four or 6-row cooling coils combine the capacities you need with the most efficient heat transfer surface. For 4-pipe systems, select either of two split-coil options. Coils consist of aluminum fins securely bonded to 1 / 2-in. OD seamless copper tubes. Each fin s aluminum collar ensures accurate control of the fin spacing, while completely covering the tubes to lengthen coil life. All coils also feature manual air vents, with automatic air vent available as an option. Fan wheels are designed to provide low operating costs The forward-curved, centrifugal, double-inlet fans are statically and dynamically balanced at the factory to minimize transmission of vibration to the building structure. Copyright 2001 Carrier Corporation Form 42BH-4PD

The belt-driven motor (single or three phase) has a variable-pitch pulley which adjusts at the jobsite to accommodate limited ranges of air quantities and pressures. All motors (single and three phase) are UL listed, factory wired, single speed with thermal overload protection and are continuous duty rated. Motors are supplied with permanently lubricated bearings, class-b insulation and are open drip-proof. The motor mount has an adjustable platform for easy belt adjustment. The motor and its mounting are independently isolated from the cabinet and the blower. An adjustable pitch pulley allows CFM balancing to meet system requirements. Motor drive packages are provided with keyed pulleys. Complete factory assembly minimizes on-the-jobsite costs and problems Compact, lightweight units are designed for easy mounting. Knockouts designed to accept 3 / 8-in. threaded rod are provided on the top and bottom of each corner of the unit One-in. duct flanges on discharge and on return are furnished standard. These integral duct flanges cut installation time and labor expense. Durable construction means easy-to-maintain units The 42BH casings are fabricated from heavy-gage galvanized G90 steel, reinforced for maximum rigidity and structural strength. Removable side panels with tool-less camlock latches allow easy access for servicing interior components. One-inch matte surface, fiberglass thermal/acoustical insulation lines the fan coil cabinets to prevent sweating and to muffle sound transmission. The stainless steel, double-sloped condensate drain pan extends under full coil surface to cut maintenance costs. Table of contents Slide-in return-duct collar filter makes it possible to remove and replace the filter without disturbing return air ductwork. Page Features/Benefits.......................................... 1,2 Model Number Nomenclature................................... 2 Physical Data............................................... 2 Options and Accessories....................................... 3 Dimensions.............................................. 4-6 Selection Procedure.......................................... 7 Performance Data........................................ 8-16 Electrical Data............................................. 17 Controls................................................. 17 Guide Specifications...................................... 18,19 Model number nomenclature Model 42BH System Fan Coil Unit Design Size Nominal Cfm 08 800 12 1200 16 1600 20 2000 30 3000 40 4000 42BH C 08 L Coil Rows B 4, 2-Pipe L 6, 2-Pipe H 4/1, Same End Conn. K 4/2, Same End Conn. N 6/1, Same End Conn. Q 6/2, Same End Conn. 1 4 w/electric Heat 2 6 w/electric Heat NOTE: Refer to current 42 Series Master Prices for complete model definition, including motor, cfm and total static pressure. Physical data UNIT SIZE 42BH 08 12 16 20 30 40 NOMINAL CFM 800 1200 1600 2000 3000 4000 SHIPPING WT (lb) (no heat/ with heat) 205/246 256/300 312/356 344/390 437/484 553/600 FILTERS Number...Size (in.) 1...16 1 / 2 x 24 1...18 1 / 4 x 33 2...18 1 / 4 x 21 1 / 2 2...20 3 / 4 x 22 2...27 x 22 2...27 x 29 Face Area (sq ft) 2.8 4.2 5.5 6.3 8.2 10.9 COILS Size (in.) 15 x 20 15 x 29 15 x 39 18 x 40 27 x 40 27 x 54 Face Area (sq ft) 2.0 3.0 4.0 5.0 7.5 10.0 FANS Number...Size (in.) 1...9 x 6 1...10 x 7 1...11 x 10 1...12 x 9 1...12 x 12 1...15 x 12 COPPER COIL CONN. 4 AND 6 ROW (in.) (Cooling) 7 / 8 OD 7 / 8 OD 1 1 / 8 OD 1 1 / 8 OD 1 5 / 8 OD 1 5 / 8 OD COPPER COIL CONN. 1 AND 2 ROW (in.) (Heating) 5 / 8 OD 5 / 8 OD 5 / 8 OD 5 / 8 OD 5 / 8 OD 5 / 8 OD DRAIN CONN. SIZES (in.) 3 / 4 MPT 3 / 4 MPT 3 / 4 MPT 3 / 4 MPT 3 / 4 MPT 3 / 4 MPT 2

Options and accessories The 42BH units are designed to offer maximum flexibility in application, accessibility for service, quiet operation and durability. Motors A wide selection of standard motors provides efficient operation in ducted applications with excellent performance with up to 2 inches of total static pressure. Available motor options: 115v, 208v, 230v and 277v single phase 60 Hz 208v, 230v and 460v three phase 60 Hz Open drip-proof motors External junction box Coils A choice of two-pipe system with 4 row cooling/ heating or four-pipe system with 4 or 6 row cooling and 1 or 2 row heating. Electric heat Total electric heat eliminates the requirement for a boiler. Heating and/or cooling may be available on an individual basis throughout the year. Resistance electric heat is available from 1.0 kw to 40.0 kw (refer to electric heater data table for availability per unit) with singlestage or multiple-stage, single power source. Voltages: 115v, 208v, 230v and 277v single phase 60 Hz 208v, 230v and 480v three phase 60 Hz Electric heat is available with the following staging options (3-phase staging is balanced). 1 to 4 kw 1 stage only single phase 5 to 12 kw 1 or 2 stage only single phase 1 to 12 kw 1 stage only 3 phase 15 to 20 kw 1 or 2 stage only 3 phase 25 to 40 kw 1, 2, or 3 stage 3 phase Heater coils are constructed of high-grade resistance wire that is supported by ceramic insulators on plated steel brackets. These heat elements are suspended directly in front of the outlet after the blower and the coil. High limit thermal cutouts protect the heater in the event of air failure. Controls Interlocking Disconnect Switch Heater power fusing 24 V Class 2 transformer (40 VA) 8-pole control terminal strip Auto reset temperature limit switch Airflow safety switch Motor power fusing Motor control contactor Filters Filters are available, 2-in. pleated as standard, 1-in. pleated or (2) 1-in. throwaways available. 3

Dimensions 42BHC BASE UNIT WITH 4 x 4 J BOX J 2 G HANGER ROD (TYP. OF 4) 1" INSET FROM A & B DIM. K UNIT INSTALLATION REF. VIEW ONLY HANGER ROD HOLES 5/8" (TYP. OF 4) TOP VIEW 4X4 J-BOX (SAME SIDE AS COIL CONNECTIONS) SIDE ACCESS PANEL COIL SUPPLY CONN. L D F 1 3/8 COIL RETURN CONN. 1" RETURN AIR COLLAR H C E SUPPLY AIR 1 1/16 A 2 7/8 FRONT VIEW 1" SUPPLY AIR COLLAR B SIDE VIEW FILTER TRACK 3 3/16 3/4" MPT DRAIN CONNECTION 1/2" MPT SECONDARY DRAIN CONNECTION (CAPPED) UNIT DIMENSIONS (in.) 42BH A B C D E F G H J K L 08 28 11 / 16 36 3 / 16 18 1 / 2 8 5 / 8 10 9 / 16 13 7 / 8 24 1 / 16 16 7 / 16 27 3 / 16 35 1 / 4 1 1 / 8 12 37 1 / 16 37 3 / 4 20 1 / 4 10 11 11 / 16 13 7 / 8 33 1 / 16 13 3 / 16 36 3 / 16 36 13 / 16 1 1 / 8 16 47 1 /16 37 15 /16 20 1 /4 13 7 /16 12 11 /16 16 13 /16 43 1 /16 18 3 /16 46 3 /16 37 1 1 /8 20 48 1 / 16 40 3 / 8 22 3 / 4 12 5 / 8 13 3 / 4 17 3 / 4 44 1 / 16 20 11 / 16 47 3 / 16 39 7 / 16 1 1 / 8 30 48 1 / 16 40 3 / 8 31 15 15 / 16 13 3 / 4 16 1 / 16 44 1 / 16 26 15 / 16 47 3 / 16 39 7 / 16 6 1 / 8 40 62 1 /16 43 9 /16 31 16 7 /16 16 1 /16 22 13 /16 58 1 /16 26 15 /16 61 3 /16 42 5 /8 5 1 /8 1. Any modifications to product specifications by any person are subject to acceptance of the factory. Product specifications are subject to change without notice. 2. All dimensions are ± 1 / 4 in. 3. RH shown, LH opposite. 4. Hanger rods, which are field-supplied, are shown for reference only. 4

42BHC WITH MOTOR CONTROL OPTION J 2 G HANGER ROD (TYP. OF 4) 1" INSET FROM A & B DIM. K UNIT INSTALLATION REF. VIEW ONLY HANGER ROD HOLES 5/8" (TYP. OF 4) TOP VIEW 10 CONTROL BOX (SAME SIDE AS COIL CONNECTIONS) 1" SUPPLY AIR COLLARS SIDE ACCESS PANEL COIL SUPPLY CONN. COIL RETURN CONN. L D F 1 3/8 1" RETURN AIR COLLAR H C E 1 1/16 A FRONT VIEW 1 1/16 8 3/4 B FILTER TRACK 3 3/16 3/4" MPT DRAIN CONNECTION 1/2" MPT SECONDARY DRAIN CONNECTION (CAPPED) SIDE VIEW UNIT DIMENSIONS (in.) 42BH A B C D E F G H J K L 08 28 11 /16 36 3 /16 18 1 /2 8 5 /8 10 9 /16 13 7 /8 24 1 /16 16 7 /16 27 3 /16 35 1 /4 1 1 /8 12 37 1 / 16 37 3 / 4 20 1 / 4 10 11 11 / 16 13 7 / 8 33 1 / 16 13 3 / 16 36 3 / 16 36 13 / 16 1 1 / 8 16 47 1 / 16 37 15 / 16 20 1 / 4 13 7 / 16 12 11 / 16 16 13 / 16 43 1 / 16 18 3 / 16 46 3 / 16 37 1 1 / 8 20 48 1 /16 40 3 /8 22 3 /4 12 5 /8 13 3 /4 17 3 /4 44 1 /16 20 11 /16 47 3 /16 39 7 /16 1 1 /8 30 48 1 / 16 40 3 / 8 31 15 15 / 16 13 3 / 4 16 1 / 16 44 1 / 16 26 15 / 16 47 3 / 16 39 7 / 16 6 1 / 8 40 62 1 / 16 43 9 / 16 31 16 7 / 16 16 1 / 16 22 13 / 16 58 1 / 16 26 15 / 16 61 3 / 16 42 5 / 8 5 1 / 8 1. Any modifications to product specifications by any person are subject to acceptance of the factory. Product specifications are subject to change without notice. 2. All dimensions are ± 1 / 4 in. 3. RH shown, LH opposite. 4. Hanger rods, which are field-supplied, are shown for reference only. 5

Dimensions (cont) 42BHC WITH ELECTRIC HEAT J 2 G HANGER ROD (TYP. OF 4) 1" INSET FROM A & B DIM. K HANGER ROD HOLES 5/8" (TYP. OF 4) 20 CONTROL BOX (SAME SIDE AS COIL CONNECTIONS) UNIT INSTALLATION REF. VEW ONLY SIDE ACCESS PANEL TOP VIEW COIL SUPPLY CONN. M D F L 1 3/8 COIL RETURN CONN. 1" RETURN AIR COLLAR H C E 16 1/2 AIR FLOW 1 1/16 ELECTRIC HEAT ELEMENTS A FRONT VIEW N 1" SUPPLY COLLAR 8 3/4 B SIDE VIEW 3 3/16 FILTER TRACK 3/4" MPT DRAIN CONNECTION 1/2" MPT SECONDARY DRAIN CONNECTION (CAPPED) UNIT DIMENSIONS (in.) 42BH A B C D E F G H J K L M N 08 28 11 / 16 36 3 / 16 18 1 / 2 8 5 / 8 10 9 / 16 13 7 / 8 24 1 / 16 16 7 / 16 27 3 / 16 35 1 / 4 1 1 1 / 8 6 1 / 4 12 37 1 / 16 37 3 / 4 20 1 / 4 10 11 11 / 16 13 7 / 8 33 1 / 16 13 3 / 16 36 3 / 16 36 13 / 16 1 1 1 / 8 6 1 / 4 16 47 1 /16 37 15 /16 20 1 /4 13 7 /16 12 11 /16 16 13 /16 43 1 /16 18 3 /16 46 3 /16 37 1 1 1 /8 3 3 /8 20 48 1 / 16 40 3 / 8 22 3 / 4 12 5 / 8 13 3 / 4 17 3 / 4 44 1 / 16 20 11 / 16 47 3 / 16 39 7 / 16 1 1 1 / 8 2 7 / 16 30 48 1 / 16 40 3 / 8 31 15 15 / 16 13 3 / 4 16 1 / 16 44 1 / 16 26 15 / 16 47 3 / 16 39 7 / 16 6 6 1 / 8 4 1 / 16 40 62 1 /16 43 9 /16 31 16 7 /16 16 1 /16 22 13 /16 58 1 /16 26 15 /16 61 3 /16 42 5 /8 5 5 1 /8 1. Any modifications to product specifications by any person are subject to acceptance of the factory. Product specifications are subject to change without notice. 2. All dimensions are ± 1 / 4 in. 3. RH shown, LH opposite. 4. Hanger rods, which are field-supplied, are shown for reference only. 6

Selection procedure This section provides quick-selection tables for the 42BH. Quick selection tables are based on nominal CFM. Correction factors are provided for other operating conditions as explained in the following quick selection example. For applications outside the range provided in this catalog, please consult the factory. FORMULAS TC = TCb x Ct x Et SC = SCb x Cs x Es Where: Cs = Sensible Air Flow Correction Factor Ct = Total Air Flow Correction Factor Es = Sensible Elevation Correction Factor Et = Total Elevation Correction Factor SC = Sensible Capacity SCb = Base Sensible Capacity from Base Cooling Capacities by GPM charts TC = Total Capacity TCb = Base Total Capacity from Base Cooling Capacities by GPM charts EXAMPLE 1: I Rate unit performance To rate the performance at sea level for an 42BHC-16 unit with a four-row coil at 80 F/67 F EAT, 45 F EWT, 7 GPM water flow, and 1500 CFM: a) Enter the Base Cooling Capacities by GPM, Standard Capacity Units (Four Row) table on 80 F/67 F EAT and 45 F EWT. b) Locate the appropriate row for unit size 16 and 7 GPM. Record the tabulated base performance. TCb = 43.8 MBtuh SCb = 34.9 MBtuh T = 12.5 F c) Divide CFM Actual by CFM Nominal to determine CFM Ratio. CFM Ratio = 1500/1600 =.9375 II Select CFM correction factors Select the CFM correction factors, Ct and Cs, from the Air Flow Correction Factors table. (Interpolation may be required.) Ct =.9625 Cs =.96 Select the elevation correction factors, Et and Es, from the Elevation Correction Factors table. (No correction necessary in this example, unit is at sea level). Et = 1.00 Es = 1.00 III Calculate actual performance. TC = TCb x Ct x Et = 43.8 x.9625 x 1.00 = 42.16 MBtuh SC = SCb x Cs x Es = 34.9 x.96 x 1.00 = 33.50 MBtuh a) Calculate water pressure drop (or refer to the Water Pressure Drop for Cv Factor and Water Flow Rate table on page 16). From the Cv Factor by Coil and Unit Size table on page 15, find the Cv value for unit size 16 with four rows. Cv = 7.2 P = [GPM/(0.658 x Cv)]2 = [7.0/(0.658 x 7.2)]2 = 2.18 feet of H 2O b) For selections other than those listed here, please contact the factory. IV Determine motor and drive To determine motor and drive selection requirements and obtain the CFM for a specific application, the total static pressure (TSP) for that application must be determined. The TSP is the sum of the internal static pressure (ISP) and the external static pressure (ESP) measured in inches of water column. ISP is sum of the static resistance of the components of the unit the cabinet, coil and filter. ESP is the static resistance of the external components of the unit, including, but not limited to, duct work, grilles and additional filtration. For nonducted applications, the ESP is 0 inches. After the TSP has been calculated (see the following example), use the motor horsepower table to determine the actual horsepower (HP) for your Belt Drive unit. Horsepower offerings are limited to 1 / 4, 1 / 3, 1 / 2, 3 /4, 1, 1 1 /2, 2 and 3. The standard selection is the nearest offering above the actual HP shown in the table. Using the TSP of the table, match the unit size with the CFM row to determine the correct motor for your specific application. Drive sheaves and the required belt assembly will be provided to meet your design requirements. Drive sheaves are set at the factory. Calculate the HP and drive selection required to deliver 1500 CFM on a 42BHC-16 unit equipped with a fourrow hydronic cooling coil and a two-inch pleated filter in a ducted application at.38 inches ESP, including duct and grille losses. Using the Component Static Resistance table on page 15, the ISP is calculated as follows: Cabinet 4-row Wet Coil 2-in. Filter ISP ESP TSP.09-in. wg.30-in. wg.12-in. wg.51-in. wg.38-in. wg.89-in. wg 7

Performance data 42BH AIRFLOW CORRECTION FACTORS CFM RATIO (Actual/Base) TOTAL (Ct) SENSIBLE (Cs) 1.40 1.25 1.26 1.35 1.22 1.23 1.30 1.19 1.20 1.25 1.16 1.17 1.20 1.13 1.14 1.15 1.10 1.11 1.10 1.07 1.08 1.05 1.04 1.04 1.00 1.00 1.00 0.95 0.97 0.97 0.90 0.94 0.93 0.85 0.90 0.89 0.80 0.86 0.85 0.75 0.82 0.81 0.70 0.78 0.77 0.65 0.74 0.72 0.60 0.70 0.67 0.55 0.66 0.62 0.50 0.62 0.57 0.45 0.58 0.52 0.40 0.53 0.47 0.35 0.48 0.42 0.30 0.43 0.38 0.25 0.38 0.33 NOTE: Use Sensible Heat correction factors when calculating heating capacity. DIRECT EXPANSION (DX) CORRECTION FACTORS % OF CORRECTION FACTOR NOMINAL CFM Total Sensible 80 0.95 0.93 90 0.97 0.96 100 1.00 1.00 110 1.02 1.04 120 1.05 1.08 Consult factory for values outside of table. DX Total Capacity (MBtuh) = Base Et x Total Correction Factor DX Sensible Capacity (MBtuh) = Base Es x Sensible Correction Factor % of Nominal Cfm = Actual Cfm (from Fan Performance table) Nominal Cfm ALTITUDE COOLING CORRECTION FACTORS ELEVATION (ft) TOTAL HEAT (Et) SENSIBLE HEAT (Es) 1000 0.99 0.96 2000 0.98 0.93 3000 0.97 0.89 4000 0.96 0.86 5000 0.94 0.83 6000 0.93 0.80 7000 0.92 0.77 8000 0.91 0.75 9000 0.90 0.73 1. Leaving air temperature not to exceed 104 F with standard motor. 2. Base capacity ratings based on 180 F entering water temperature and 70 F entering air temperature. 3. Hot Water Heating Capacity (MBtuh) = Rated Heating Capacity x Hot Water Capacity Correction Factor x Sensible Air Flow Correction Factor. 42BH HOT WATER CAPACITY CORRECTION FACTORS ENTERING AIR ENTERING WATER TEMPERATURE (F) TEMPERATURE (F) 100 110 120 130 140 150 160 170 180 190 200 50 0.455 0.545 0.636 0.727 0.818 0.909 1.000 1.091 1.182 1.273 1.364 55 0.409 0.500 0.591 0.682 0.773 0.864 0.955 1.045 1.136 1.227 1.318 60 0.363 0.455 0.545 0.636 0.727 0.818 0.909 1.000 1.091 1.182 1.273 65 0.318 0.409 0.500 0.591 0.682 0.773 0.864 0.955 1.045 1.136 1.227 70 0.272 0.363 0.455 0.545 0.636 0.727 0.818 0.909 1.000 1.091 1.182 75 0.227 0.318 0.409 0.500 0.591 0.682 0.773 0.864 0.955 1.045 1.136 80 0.182 0.272 0.363 0.455 0.545 0.636 0.727 0.818 0.909 1.000 1.091 8

42BH NOMINAL COOLING CAPACITIES UNIT SIZE 42BH NOMINAL CFM 08 800 12 1200 16 1600 20 2000 30 3000 40 4000 LEGEND EWT Entering Water Temperature COIL ROWS *Based on entering air temperature of 67 F wb, 80 F db and temperature rise of 10 degrees F. NOTE: All ratings at sea level. Ratings in accordance with ARI (Air Conditioning & Refrigeration Institute). 4 6 4 6 4 6 4 6 4 6 4 6 EWT (F) COOLING* Sensible Capacity (MBtuh) Total Capacity (MBtuh) 40 29.9 20.9 45 23.2 18.1 50 17.7 15.5 40 40.7 26.2 45 32.2 22.6 50 24.4 19.3 40 47.8 23.5 45 37.7 28.2 50 28.8 24.4 40 62.5 40.0 45 50.2 34.6 50 38.2 29.6 40 63.2 43.1 45 49.4 37.3 50 37.9 32.3 40 83.2 53.3 45 66.9 46.1 50 51.1 39.5 40 79.8 54.1 45 63.0 47.1 50 48.4 40.8 40 104.3 66.7 45 84.1 57.8 50 64.3 49.6 40 119.7 81.5 45 93.9 70.7 50 72.2 61.2 40 157.5 100.7 45 126.9 87.2 50 97.1 74.8 40 166.9 111.9 45 132.7 97.4 50 102.1 84.3 40 202.5 129.6 45 160.8 111.8 50 122.7 96.7 UNIT SIZE 42BH 42BH NOMINAL HEATING CAPACITIES NOMINAL CFM 08 800 12 1200 16 1600 20 2000 30 3000 40 4000 HEATING ROWS CAPACITY MBtuh 1 27.0 2 46.9 1 38.5 2 68.5 1 48.0 2 87.7 1 58.7 2 104.9 1 78.0 2 149.2 1 92.3 2 182.4 1. Ratings are based on 180 F EWT and 70 F EAT. 2. Leaving-air temperature is not to exceed 104 F (40 C) with the standard motor. Consult the factory for higher temperature motor applications. 3. For information on four and six-row heating coil capacities and applications, consult the factory. 4. For all application ratings, use the quick-selection ratings provided in this catalog, or contact the factory. 9

Performance data (cont) UNIT SIZE 42BH 08 12 16 20 30 40 GPM 1. All capacities are given in thousands of BTUH (MBH). 2. TC b = Base Total Capacity at Nominal CFM; SC b = Base Sensible Capacity at Nominal CFM; T = Change in Water Temperature (F) 42BH 4-ROW COOLING CAPACITY (GPM) 75 F DB/ 63 F WB 80 F DB/67 F WB 85 F DB/71 F WB 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b 2 15.9 15.9 14.3 13.8 13.8 12.8 11.0 11.0 11.0 18.4 18.4 15.7 16.3 16.3 14.5 14.2 14.2 13.0 21.1 21.1 17.0 18.9 18.9 16.0 16.8 16.8 14.8 3 12.7 19.1 16.2 10.9 16.3 14.7 9.2 13.8 12.9 15.0 22.5 17.7 13.0 19.5 16.4 11.2 16.7 15.0 17.4 26.1 19.1 15.3 23.0 17.9 13.3 20.0 16.6 4 10.7 21.5 17.4 9.0 18.0 15.7 7.5 14.9 13.9 12.8 25.6 19.0 11.0 21.9 17.5 9.2 18.4 16.0 15.0 30.0 20.6 13.1 26.2 19.2 11.2 22.4 17.7 5 9.3 23.3 18.2 7.7 19.4 16.4 6.3 15.7 14.6 11.2 28.0 20.1 9.5 23.8 18.3 7.9 19.7 16.6 13.2 33.1 21.8 11.5 28.7 20.1 9.7 24.3 18.5 6 8.3 24.8 18.9 6.8 20.4 16.9 5.4 16.3 15.0 10.0 30.0 20.9 8.4 25.3 19.0 6.9 20.7 17.1 11.8 35.5 22.8 10.2 30.7 20.9 8.6 25.8 19.1 3 17.3 26.0 22.5 15.0 22.6 20.4 11.8 17.7 17.7 20.2 30.2 24.7 17.8 26.7 22.9 15.5 23.2 20.8 23.2 34.7 26.6 20.7 31.0 25.0 18.3 27.4 23.2 4 14.7 29.5 24.5 12.6 25.2 22.3 10.6 21.2 19.6 17.3 34.7 26.8 15.1 30.1 24.8 12.9 25.8 22.6 20.2 40.3 29.0 17.7 35.5 27.1 15.4 30.8 25.1 5 12.9 32.2 25.9 10.9 27.2 23.5 9.0 22.6 20.8 15.3 38.3 28.4 13.1 32.9 26.2 11.1 27.7 23.8 17.9 44.8 30.8 15.6 39.1 28.6 13.4 33.5 26.4 6 11.5 34.4 27.0 9.6 28.7 24.4 7.8 23.5 21.6 13.7 41.2 29.7 11.7 35.1 27.1 9.7 29.1 24.6 16.2 48.5 32.2 14.0 42.1 29.7 11.9 35.6 27.3 5 14.9 37.3 31.7 12.9 32.3 28.8 10.0 25.0 25.0 17.5 43.7 34.6 15.3 38.3 32.2 13.3 33.2 29.3 20.2 50.6 37.4 17.9 44.9 35.1 15.7 39.4 32.7 7 12.3 42.9 34.6 10.4 36.3 31.4 8.6 30.2 27.7 14.6 51.0 37.9 12.5 43.8 34.9 10.6 37.0 31.8 17.1 59.7 41.0 14.9 52.2 38.1 12.8 44.8 35.3 9 10.4 47.0 36.5 8.7 39.1 32.9 7.1 31.9 29.2 12.5 56.4 40.2 10.7 48.0 36.7 8.8 39.7 33.3 14.8 66.4 43.7 12.8 57.7 40.3 10.8 48.8 36.9 11 9.1 50.1 37.9 7.5 41.2 34.0 6.0 33.0 30.0 11.0 60.4 42.0 9.3 51.0 38.0 7.6 41.7 34.2 13.0 71.5 45.7 11.2 61.6 41.8 9.4 51.8 38.1 5 17.6 43.9 37.8 15.3 38.2 34.2 11.8 29.5 29.5 20.4 51.1 41.4 18.1 45.1 38.4 15.7 39.4 34.8 23.5 58.7 44.6 21.0 52.5 42.0 18.6 46.5 39.0 7 14.5 50.7 41.6 12.4 43.2 37.8 10.4 36.3 33.3 17.1 59.8 45.5 14.8 51.8 42.0 12.7 44.3 38.3 19.9 69.6 49.2 17.5 61.1 45.9 15.1 52.9 42.5 9 12.4 55.7 44.1 10.4 46.7 39.9 8.6 38.6 35.3 14.8 66.4 48.4 12.6 56.8 44.4 10.6 47.5 40.3 17.3 77.9 52.5 15.1 67.8 48.6 12.8 57.6 44.7 11 10.8 59.6 45.9 9.0 49.3 41.3 7.3 40.0 36.5 13.0 71.6 50.6 11.0 60.5 46.0 9.1 50.0 41.6 15.3 84.3 55.0 13.2 72.7 50.5 11.2 61.4 46.2 7 17.7 61.8 54.4 15.4 54.0 49.0 11.9 41.8 41.8 20.5 71.7 59.9 18.2 63.8 55.4 16.0 55.8 49.9 23.5 82.1 64.7 21.1 73.9 60.9 18.8 65.9 56.4 9 15.5 69.6 59.2 13.4 60.3 53.8 10.3 46.5 46.5 18.1 81.5 64.9 15.9 71.6 60.2 13.8 62.1 54.7 20.9 94.1 70.0 18.6 83.7 65.7 16.4 73.6 61.1 11 13.8 76.0 62.7 11.8 65.0 57.0 9.9 54.6 50.1 16.3 89.7 68.6 14.1 77.8 63.4 12.1 66.6 57.8 19.0 104.4 74.1 16.7 91.8 69.2 14.5 79.6 64.2 14 11.9 83.4 66.3 10.0 70.2 60.1 8.3 58.1 53.1 14.2 99.4 72.8 12.2 85.2 66.9 10.2 71.6 60.8 16.7 116.6 78.9 14.5 101.7 73.2 12.4 87.0 67.5 17 10.5 89.3 69.1 8.7 74.2 62.2 7.1 60.4 55.0 12.6 107.1 76.1 10.7 91.2 69.5 8.9 75.3 62.8 14.9 126.3 82.7 12.9 109.7 76.3 10.9 92.5 69.8 11 17.5 96.3 80.5 15.2 83.3 73.0 12.9 70.8 63.9 20.5 112.5 88.0 18.0 98.7 81.4 15.6 85.7 74.0 23.6 129.7 94.8 20.9 115.2 88.8 18.4 101.3 82.4 14 15.1 106.0 85.7 12.9 90.4 77.8 10.9 76.0 68.6 17.9 125.2 93.9 15.5 108.3 86.5 13.2 92.6 78.8 20.8 145.6 101.4 18.3 127.9 94.4 15.8 110.7 87.4 17 13.4 113.9 89.6 11.3 95.8 81.0 9.3 79.3 71.6 15.9 135.5 98.4 13.7 116.2 90.2 11.5 97.3 81.8 18.7 158.7 106.6 16.3 138.4 98.6 13.8 117.7 90.6 21 11.6 122.3 93.6 9.7 101.8 84.3 7.9 82.5 74.3 13.9 146.4 103.1 11.9 124.8 94.0 9.8 102.8 84.7 16.4 172.1 111.9 14.3 149.7 103.1 12.0 126.1 94.1 25 10.3 129.1 96.7 8.5 105.8 86.2 6.8 84.4 75.9 12.4 155.3 106.9 10.5 130.7 96.5 8.5 106.6 86.6 14.7 183.3 116.3 12.6 157.7 106.2 10.6 132.0 96.5 UNIT SIZE 42BH 08 12 16 20 30 40 GPM 1. All capacities are given in thousands of BTUH (MBH). 2. TC b = Base Total Capacity at Nominal CFM; SC b = Base Sensible Capacity at Nominal CFM; T = Change in Water Temperature (F) 42BH 6-ROW COOLING CAPACITY (GPM) 75 F DB/ 63 F WB 80 F DB/67 F WB 85 F DB/71 F WB 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b T TC b SC b 3 16.0 24.1 19.1 13.6 20.5 17.4 10.4 15.6 15.6 19.0 28.5 20.9 16.4 24.6 19.3 14.0 21.0 17.8 22.2 33.3 22.6 19.5 29.2 21.1 16.8 25.2 19.5 4 13.5 27.0 20.5 11.3 22.6 18.5 9.3 18.7 16.6 16.2 32.3 22.6 13.8 27.6 20.6 11.5 23.1 18.7 19.1 38.2 24.6 16.5 33.1 22.6 14.1 28.2 20.7 5 11.7 29.2 21.5 9.7 24.2 19.3 7.8 19.5 17.1 14.1 35.3 23.8 11.9 29.8 21.5 9.8 24.6 19.4 16.7 41.8 26.0 14.5 36.2 23.8 12.2 30.5 21.6 6 10.3 30.9 22.3 8.5 25.4 19.8 6.7 20.1 17.5 12.5 37.5 24.8 10.5 31.6 22.3 8.6 25.8 19.9 14.9 44.6 27.2 12.9 38.6 24.7 10.7 32.2 22.3 6 14.3 42.8 31.7 11.8 35.5 28.5 9.7 29.0 25.4 17.2 51.5 35.1 14.5 43.6 31.8 12.0 36.1 28.7 8 11.7 46.8 33.6 9.5 38.2 29.7 7.6 30.3 26.2 14.2 56.7 37.4 11.9 47.5 33.5 9.6 38.6 29.8 20.3 60.9 38.2 17.6 52.7 35.0 14.8 44.3 31.8 10 9.9 49.3 34.8 8.0 39.9 30.5 6.2 31.2 26.7 12.0 59.8 38.8 10.0 50.1 34.6 8.1 40.3 30.5 14.2 71.1 42.5 12.2 61.2 38.4 10.2 50.9 34.4 7 15.4 53.8 40.8 13.0 45.3 37.0 10.8 37.9 33.2 18.4 64.3 45.0 15.7 55.0 41.0 13.3 46.4 37.4 21.6 75.7 48.8 18.8 65.7 44.9 16.1 56.3 41.3 9 13.0 58.7 43.2 10.8 48.7 38.6 8.8 39.7 34.4 15.7 70.8 47.8 13.3 60.0 43.2 11.0 49.5 38.8 18.6 83.8 52.1 16.1 72.6 47.6 13.6 61.0 43.2 11 11.4 62.5 44.9 9.3 51.1 39.8 7.4 40.8 35.1 13.7 75.6 49.9 11.6 63.5 44.7 9.4 51.9 39.9 16.3 89.6 54.5 14.0 77.2 49.4 11.7 64.6 44.6 13 10.1 65.3 46.2 8.2 53.1 40.7 6.4 41.7 35.6 12.2 79.2 51.5 10.2 66.5 45.9 8.2 53.6 40.6 14.5 94.0 56.4 12.5 81.0 50.9 10.4 67.4 45.7 7 18.1 63.3 49.1 15.4 53.9 44.7 11.4 39.8 39.8 18.0 63.0 63.0 15.9 55.5 55.5 13.7 47.9 47.9 25.2 88.0 58.3 21.9 76.8 53.9 18.9 66.2 49.9 9 15.4 69.5 52.1 12.9 58.1 46.9 10.7 48.3 42.1 14.9 67.0 67.0 13.1 59.0 59.0 11.3 50.8 50.8 21.9 98.4 62.4 18.9 85.1 57.3 16.0 71.9 52.2 11 13.5 74.3 54.3 11.1 61.2 48.4 9.0 49.7 43.1 12.7 69.6 69.6 11.1 61.1 61.1 9.6 52.6 52.6 19.2 105.8 65.5 16.6 91.5 59.8 13.9 76.7 54.0 13 12.0 78.1 56.1 9.8 63.7 49.5 7.8 50.8 43.8 11.0 71.4 71.4 9.6 62.6 62.6 8.3 53.8 53.8 17.2 111.7 67.9 14.8 96.1 61.6 12.3 80.1 55.4 15 10.8 80.7 57.3 8.7 65.6 50.4 6.9 51.6 44.2 9.7 72.6 72.6 8.5 63.6 63.6 7.3 54.6 54.6 15.5 115.9 69.7 13.3 99.8 63.0 11.1 83.1 56.6 11 17.4 95.7 74.2 14.8 81.6 67.6 12.5 69.1 60.5 20.6 113.5 81.3 17.8 98.1 74.8 15.2 83.8 68.6 24.2 133.0 88.1 21.1 116.2 81.6 18.3 100.4 75.5 14 15.0 104.7 78.5 12.5 87.8 70.8 10.4 73.1 63.6 17.9 125.6 86.6 15.3 107.1 78.7 12.8 89.8 71.6 21.1 148.0 94.1 18.4 128.5 86.4 15.6 109.3 79.1 17 13.2 111.8 81.8 10.9 92.7 73.1 8.9 75.4 65.1 15.9 134.9 90.6 13.4 114.1 81.7 11.1 94.1 73.5 18.8 159.5 98.7 16.3 138.2 90.2 13.6 115.9 81.6 21 11.3 119.0 85.2 9.3 97.2 75.2 7.4 77.5 66.3 13.7 144.0 94.5 11.6 121.5 84.9 9.4 98.7 75.5 16.2 170.5 103.3 14.1 147.6 93.9 11.7 123.1 84.4 17 16.7 141.6 105.5 14.0 118.9 95.1 11.7 99.3 85.5 20.0 169.6 116.4 17.0 144.4 105.6 14.2 121.0 95.8 23.5 199.6 126.3 20.3 172.6 115.7 17.2 146.3 105.6 21 14.5 151.8 110.4 12.0 126.0 98.5 9.8 102.5 87.6 17.4 182.5 121.9 14.7 154.6 109.9 12.2 127.6 98.8 20.6 216.6 133.3 17.8 186.7 121.2 14.9 156.7 109.6 25 12.8 159.8 114.1 10.4 130.6 100.7 8.3 104.3 88.8 15.4 192.9 126.5 13.0 162.2 113.3 10.6 132.2 100.8 18.2 228.1 138.1 15.7 196.6 125.1 13.1 164.1 112.6 10

UNIT SIZE 42BH 08 12 16 20 30 40 T 1. All capacities are given in thousands of BTUH (MBH). 2. TC b = Base Total Capacity at Nominal CFM; SC b = Base Sensible Capacity at Nominal CFM; T = Change in Water Temperature (F) 42BH 4-ROW COOLING CAPACITY ( T) 75 F DB/ 63 F WB 80 F DB/67 F WB 85 F DB/71 F WB 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b 10 4.5 22.4 17.8 3.4 17.1 15.2 2.5 12.5 12.0 6.0 29.9 20.9 4.6 23.2 18.1 3.5 17.7 15.5 7.7 38.5 24.0 6.2 31.0 21.0 4.8 23.9 18.3 12 3.3 20.0 16.6 2.6 15.4 14.0 4.5 26.8 19.6 3.5 20.7 16.9 2.7 16.0 14.4 5.9 35.1 22.6 4.7 27.9 19.8 3.6 21.5 17.3 14 2.5 17.8 15.4 3.4 23.9 18.3 2.7 18.6 15.8 2.1 14.4 13.2 4.5 31.7 21.3 3.6 24.9 18.7 2.8 19.3 16.3 16 2.7 21.3 17.1 2.1 16.6 14.7 3.6 28.4 20.0 2.8 22.3 17.5 2.2 17.5 15.2 18 2.1 18.9 15.9 2.8 25.3 18.8 2.2 19.9 16.5 10 7.4 36.9 28.1 5.6 28.2 24.1 4.4 21.8 20.0 9.6 47.8 32.5 7.5 37.7 28.2 5.8 28.8 24.4 12.0 59.0 36.8 9.8 49.0 32.4 7.6 38.2 28.3 12 5.6 33.6 26.6 4.3 25.9 22.7 2.9 17.4 17.4 7.4 44.4 31.0 5.8 34.6 26.9 4.5 26.7 23.2 9.4 56.4 35.4 7.6 45.6 31.1 5.9 35.4 27.2 16 4.4 30.5 25.1 3.4 23.7 21.2 2.2 15.0 15.0 5.8 40.7 29.5 4.5 31.6 25.6 3.5 24.7 21.8 7.5 52.7 33.9 6.0 42.1 29.8 4.7 32.7 26.0 16 3.5 27.7 23.5 2.5 20.1 18.9 4.6 37.0 27.9 3.6 24.2 29.1 2.7 21.8 19.9 6.1 48.8 32.3 4.8 38.5 28.3 3.8 30.1 24.7 18 2.8 25.1 21.9 3.7 33.7 26.3 2.9 26.4 22.7 5.0 44.6 30.7 3.9 35.1 26.9 3.1 27.7 23.4 10 9.6 48.0 37.0 7.4 36.9 31.7 5.0 25.1 25.1 12.6 63.2 43.1 9.9 49.4 37.3 7.6 37.9 32.3 15.9 79.3 48.9 13.0 64.8 43.1 10.1 50.5 37.6 12 7.3 43.5 34.8 5.6 33.6 29.7 3.6 21.7 21.7 9.6 57.8 40.8 7.5 45.0 35.4 5.8 35.0 30.5 12.4 74.5 38.7 10.0 59.7 41.1 7.7 46.4 35.9 14 5.6 39.2 32.7 4.1 28.6 26.6 7.5 52.5 38.6 5.9 40.9 33.5 4.4 30.6 27.8 9.8 68.6 31.6 7.8 54.6 39.1 6.1 42.5 34.2 16 4.4 35.2 30.3 5.9 47.4 36.3 4.6 37.1 31.4 7.9 62.8 42.2 6.2 49.6 37.1 4.8 38.0 32.4 18 3.5 31.2 27.7 4.7 42.5 34.0 3.7 33.4 29.0 6.3 57.0 40.0 5.0 44.8 35.0 3.9 34.9 30.1 10 12.4 61.9 47.0 9.5 47.4 40.2 7.6 38.2 34.3 16.0 79.8 54.1 12.6 63.0 47.1 9.7 48.4 40.8 19.9 99.7 61.2 16.3 81.7 54.0 12.8 64.0 47.2 12 9.4 56.6 44.5 7.3 43.9 38.2 4.9 29.2 29.2 12.4 74.6 51.9 9.7 58.2 45.0 7.6 45.3 38.9 15.7 94.2 59.0 12.7 76.3 51.9 9.9 59.5 45.4 16 7.4 51.8 42.2 5.8 40.4 35.8 3.6 25.1 25.1 9.8 68.6 49.4 7.7 53.6 42.9 6.0 42.1 36.8 12.7 88.6 56.7 10.1 70.6 49.7 7.9 55.2 43.6 16 5.9 47.3 39.7 4.4 35.2 32.3 7.9 62.9 46.9 6.2 49.3 40.7 4.8 38.2 34.1 10.3 82.2 54.1 8.2 65.3 47.5 6.4 51.3 41.6 18 4.8 42.9 37.1 6.4 57.4 44.4 5.0 45.3 38.4 3.2 28.8 28.3 8.4 75.7 51.6 6.7 59.8 45.3 5.3 47.6 39.6 10 18.3 91.5 70.1 14.1 70.2 60.1 10.7 53.3 49.5 23.9 119.7 81.5 18.8 93.9 70.7 14.4 72.2 61.2 30.0 150.1 92.3 24.6 122.9 81.4 19.2 96.0 71.1 12 13.9 83.1 66.2 10.7 64.4 56.6 18.3 110.1 77.4 14.3 85.9 67.2 11.1 66.9 58.0 23.5 141.1 88.6 19.0 114.0 78.0 14.7 88.5 68.1 14 10.8 75.3 62.3 8.4 58.4 52.4 14.3 100.4 73.3 11.2 78.4 63.7 8.8 61.5 54.3 18.7 130.8 84.5 14.9 104.3 74.2 11.6 81.3 65.0 16 8.5 67.7 558.1 11.4 91.1 68.4 8.9 71.3 60.0 15.0 120.1 80.3 11.9 95.0 70.5 9.3 74.7 61.7 18 9.1 81.9 65.1 7.2 64.5 55.8 12.2 109.5 76.1 9.6 86.2 66.8 7.6 68.4 58.0 14 15.9 111.2 88.3 12.4 87.0 75.5 7.8 54.3 54.3 20.9 146.1 102.9 16.4 114.7 89.5 12.9 90.3 77.2 26.7 186.8 117.7 21.6 150.9 103.6 16.7 117.1 90.3 16 12.8 102.5 83.8 10.1 80.4 70.8 16.9 135.2 98.3 13.3 106.3 85.4 10.5 84.3 73.0 21.8 174.6 112.9 17.5 139.9 99.2 13.8 110.0 87.0 18 10.5 94.2 79.2 8.1 72.8 65.0 13.8 124.6 93.6 11.0 98.5 81.3 8.6 77.6 67.9 18.1 162.6 108.1 14.4 129.3 95.0 11.4 102.8 83.2 UNIT SIZE T 42BH 08 12 16 20 30 40 1. All capacities are given in thousands of BTUH (MBH). 2. TC b = Base Total Capacity at Nominal CFM; SC b = Base Sensible Capacity at Nominal CFM; T = Change in Water Temperature (F) 42BH 6-ROW COOLING CAPACITY ( T) 75 F DB/ 63 F WB 80 F DB/67 F WB 85 F DB/71 F WB 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b GPM TC b SC b 10 6.3 31.3 22.5 4.8 23.8 19.1 3.4 16.7 16.0 8.1 40.7 26.2 6.5 32.2 22.6 4.9 24.4 19.3 10.1 50.4 29.7 8.4 41.9 26.1 6.6 33.0 22.6 12 4.8 28.8 21.3 3.7 21.9 18.2 2.4 14.4 14.4 6.4 38.2 25.1 5.0 29.8 21.5 3.8 22.7 18.5 8.1 48.3 28.8 6.6 39.6 25.1 5.1 30.7 21.7 14 3.8 26.4 20.2 2.6 20.2 17.3 5.1 35.5 23.9 3.9 27.3 20.5 3.0 21.1 17.8 6.5 45.7 27.7 5.3 36.9 24.1 4.0 28.3 20.8 16 3.0 24.1 19.1 2.3 18.5 16.2 4.1 32.6 22.7 3.1 25.1 19.5 2.4 19.5 16.8 5.4 42.9 20.4 4.2 33.9 22.9 3.3 26.1 19.9 18 2.5 22.0 18.1 3.3 29.9 21.5 2.6 23.0 18.6 4.4 39.9 25.2 3.5 31.1 21.8 2.7 24.1 19.0 10 9.8 49.1 34.7 7.5 37.6 29.5 5.8 28.9 25.3 12.5 62.5 40.0 10.0 50.2 34.6 7.6 38.2 29.6 12.9 64.6 39.8 10.2 51.1 34.5 12 7.7 46.3 33.4 5.9 35.4 28.4 3.9 23.3 23.3 10.0 59.8 38.8 7.9 47.3 33.4 6.0 36.1 28.7 12.4 74.3 43.9 10.3 61.6 38.5 8.0 48.1 33.3 14 6.2 43.2 31.9 4.7 33.1 27.3 3.1 21.4 21.4 8.1 56.9 37.5 6.4 44.4 32.1 4.9 34.2 27.8 10.2 71.4 42.7 8.4 58.4 37.3 6.5 45.3 32.2 16 5.0 40.1 30.5 3.9 30.8 26.1 2.4 19.0 19.0 6.7 53.5 36.0 5.2 41.4 30.8 4.0 32.2 26.8 8.5 68.3 41.4 6.9 55.2 36.0 5.3 42.6 31.1 18 4.1 37.2 29.1 3.2 28.7 24.8 5.6 50.0 34.5 4.3 38.6 29.6 3.4 30.1 25.5 7.2 65.0 40.0 5.8 51.8 34.7 4.4 39.9 30.0 10 13.1 65.4 46.3 10.0 50.0 39.3 7.7 38.7 33.7 16.7 83.2 53.3 13.4 66.9 46.1 10.2 51.1 39.5 20.6 102.8 60.3 17.2 85.9 53.0 13.6 68.1 45.9 12 10.2 61.0 44.2 7.8 46.9 37.7 5.1 30.7 30.4 13.3 79.5 51.6 10.4 62.6 44.3 8.0 48.1 38.2 16.5 98.9 58.5 13.7 81.9 51.3 10.7 64.1 44.4 14 8.1 56.7 42.2 6.3 43.7 36.2 3.9 27.1 27.1 10.7 75.0 49.6 8.4 58.6 42.6 6.5 45.4 36.9 13.6 94.9 56.8 11.0 77.3 49.4 8.6 60.2 42.8 16 6.6 52.5 40.2 5.1 40.7 34.5 8.8 70.2 47.5 6.8 54.4 40.8 5.3 42.7 35.5 11.3 90.3 54.8 9.1 72.9 47.7 7.1 56.4 41.4 18 5.4 48.4 38.3 3.6 32.5 30.5 7.3 65.2 45.3 5.6 50.5 39.1 3.9 35.1 31.8 9.5 85.4 52.7 7.5 67.8 45.7 5.9 52.8 39.9 10 13.1 65.4 46.3 10.0 50.0 39.3 7.7 38.7 33.7 16.7 83.2 53.3 13.4 66.9 46.1 10.2 51.1 39.5 20.6 102.8 60.3 17.2 85.9 53.0 13.6 68.1 45.9 12 10.2 61.0 44.2 7.8 59.7 37.7 5.1 30.7 30.4 13.3 79.5 51.6 10.4 62.6 44.3 8.0 48.1 38.2 16.5 98.9 58.5 13.7 81.9 51.3 10.7 64.1 44.4 14 8.1 56.7 42.2 6.3 43.7 36.2 3.9 27.1 27.1 10.7 75.0 49.6 8.4 58.6 42.6 6.5 45.4 36.9 13.6 94.9 56.8 11.0 77.3 49.4 8.6 60.2 42.8 16 6.6 52.5 40.2 5.1 40.7 34.5 8.8 70.2 47.5 6.8 54.4 40.8 5.3 42.7 35.5 11.3 90.3 54.8 9.1 72.9 47.7 7.1 56.4 41.4 18 5.4 48.4 38.3 3.6 32.5 30.5 7.3 65.2 45.3 5.6 50.5 39.1 3.9 35.1 31.8 9.5 85.4 52.7 7.5 67.8 45.7 5.9 52.8 39.9 10 24.8 124.1 87.5 19.0 95.2 74.3 14.8 73.7 64.0 31.5 157.5 100.7 25.4 126.9 87.2 19.4 97.1 74.8 38.8 194.1 113.6 32.5 162.6 100.0 25.9 129.3 86.8 12 19.4 116.4 84.0 14.9 89.4 71.5 11.7 70.2 61.3 25.1 150.8 97.6 20.0 119.8 84.2 15.3 91.9 72.5 31.2 187.0 110.5 25.9 155.3 97.0 20.3 122.0 84.0 14 15.5 108.5 80.3 12.0 83.8 68.8 7.4 51.7 51.7 20.4 142.7 94.0 16.0 112.0 80.8 12.4 86.9 70.1 25.7 179.8 107.3 21.1 147.8 94.0 16.4 114.7 81.2 16 12.6 100.9 76.7 9.8 78.4 65.9 16.8 134.3 90.3 13.1 104.6 77.6 10.3 82.0 67.6 21.4 171.5 103.8 17.4 139.3 90.6 13.5 108.0 78.6 18 10.4 93.5 73.2 8.1 72.5 62.3 13.9 125.3 86.5 10.8 97.4 74.5 8.6 77.1 64.7 18.0 162.1 100.1 14.5 130.1 87.1 11.3 101.3 75.9 10 34.1 170.7 119.2 26.4 132.1 101.4 20.4 102.1 87.3 34.9 174.6 118.6 26.8 134.0 101.6 35.6 178.2 118.0 12 27.2 162.9 115.5 21.0 126.0 98.5 16.5 98.7 84.9 34.6 207.5 133.1 27.7 166.3 115.0 21.3 128.0 99.0 35.6 213.9 132.2 28.2 169.2 114.5 14 22.0 153.9 111.4 17.0 118.8 95.1 10.7 74.6 74.6 28.4 199.0 129.3 22.5 157.7 111.3 17.4 121.8 96.2 35.4 247.5 146.5 29.2 204.6 128.4 22.9 160.5 111.2 16 18.1 144.7 107.0 14.1 112.6 91.9 8.4 67.5 67.5 23.7 189.8 125.1 18.6 148.9 107.5 14.6 116.6 93.6 29.8 238.6 142.6 24.4 195.2 124.6 19.0 151.8 107.7 18 15.1 135.6 102.7 11.8 106.2 88.4 19.9 179.4 120.6 15.6 140.2 103.8 12.4 111.3 90.7 25.5 229.3 138.6 20.6 185.5 120.8 16.0 143.6 104.5 11

Performance data (cont) LEGEND db Dry Bulb wb Wet Bulb SH Sensible TH Total Heat DIRECT EXPANSION (DX) BASE COOLING CAPACITIES* (MBtuh) 4-ROW COIL UNIT CONNECTION R-22 ENTERING AIR TEMPERATURE (F) db/wb SIZE SIZE (in.) CFM SUCTION 75/63 80/63 75/67 80/67 80/71 85/71 42BH Liquid Suction TEMP (F) TH SH TH SH TH SH TH SH TH SH TH SH 40 17.1 13.0 17.8 16.1 21.8 12.0 22.1 15.0 27.0 13.8 27.2 16.9 600 45 12.7 11.0 14.2 14.1 17.1 10.0 17.4 13.0 22.4 12.0 22.6 15.0 50 8.5 8.5 11.1 11.1 11.9 7.9 12.6 11.0 17.2 10.0 17.5 13.1 40 20.0 15.9 21.0 19.9 25.2 14.3 25.5 18.2 30.9 16.4 31.2 20.3 08 3/ 8 5/ 8 800 45 15.0 13.6 16.8 16.8 19.9 12.1 20.2 16.0 25.8 14.4 26.1 18.3 50 10.5 10.5 13.7 13.7 13.8 9.8 15.0 13.7 19.8 12.2 20.3 16.1 40 21.1 17.2 22.4 21.5 26.6 15.4 26.9 19.6 32.5 17.6 32.8 21.8 900 45 16.0 14.8 18.2 18.2 21.0 13.1 21.4 17.4 27.2 15.5 27.5 19.8 50 11.4 11.4 14.9 14.9 14.6 10.6 16.0 15.0 21.0 13.2 21.5 17.5 40 29.2 21.9 30.0 27.0 37.4 20.4 37.8 25.4 46.6 23.8 47.0 28.8 1000 45 21.3 18.3 23.8 23.4 29.0 16.8 29.5 21.8 38.2 20.3 38.7 25.3 50 14.2 14.2 18.5 18.5 20.1 13.2 21.1 18.4 29.1 16.8 29.6 21.8 40 32.5 25.0 33.6 30.9 41.5 23.0 41.9 28.8 51.6 26.7 52.0 32.5 12 7/ 8 1200 45 23.8 21.0 26.2 26.2 32.2 19.1 32.7 25.0 42.3 23.0 42.8 28.8 50 16.3 16.3 21.3 21.3 22.2 15.2 23.6 21.2 32.2 19.1 32.7 25.0 40 33.9 26.4 35.3 32.7 43.3 24.2 43.8 30.4 53.7 28.1 54.2 34.3 1300 45 24.9 22.3 27.7 27.7 33.6 20.2 34.2 26.4 44.1 24.2 44.6 30.4 50 17.3 17.3 22.5 22.5 23.2 16.1 24.8 22.4 33.6 20.2 34.1 26.5 40 38.6 29.7 40.2 36.8 49.7 27.5 50.2 34.4 62.0 32.0 62.6 39.0 1400 45 28.2 24.9 31.0 31.0 38.3 22.7 38.9 29.7 50.6 27.4 51.2 34.4 50 19.2 19.2 25.1 25.1 26.0 17.9 28.0 25.1 38.2 22.7 38.9 29.7 40 41.7 32.7 43.6 40.6 53.4 30.0 54.0 37.8 66.5 34.8 67.2 42.6 16 5/ 8 7/ 8 1600 45 30.5 27.6 34.2 34.2 41.2 24.9 41.8 32.7 54.4 30.0 55.0 37.7 50 21.1 21.1 27.7 27.7 28.0 19.8 30.3 27.7 41.0 24.9 41.8 32.8 40 44.4 35.4 46.7 44.1 56.8 32.3 57.5 40.9 70.6 37.4 71.3 45.9 1800 45 32.7 30.0 37.1 37.1 43.8 26.9 44.5 35.5 57.7 32.3 58.4 40.9 50 23.0 23.0 30.1 30.1 29.7 21.5 32.5 30.2 43.6 27.0 44.5 35.7 40 47.8 37.3 49.9 46.3 61.0 34.1 61.7 43.0 75.6 39.5 76.3 48.3 1800 45 35.2 31.5 39.1 39.1 47.4 28.5 48.2 37.3 62.3 34.2 63.0 43.0 50 24.3 24.3 31.8 31.8 32.6 22.7 35.1 31.7 47.4 28.6 48.2 37.5 40 50.6 40.1 53.1 49.9 64.4 36.5 65.1 46.1 79.6 42.1 80.3 51.7 20 5/ 8 7/ 8 2000 45 37.5 34.1 42.1 42.1 50.1 30.6 50.9 40.2 65.7 36.5 66.4 46.2 50 26.3 26.3 34.3 34.3 34.4 24.5 37.3 34.3 50.1 30.7 51.0 40.4 40 53.1 42.8 56.0 53.3 67.5 38.7 68.2 49.1 83.2 44.5 84.0 54.9 2200 45 39.6 36.5 45.0 45.0 52.5 32.5 53.4 43.0 68.7 38.8 69.5 49.2 50 28.1 28.1 36.6 36.6 36.1 26.2 39.4 36.7 52.4 32.7 53.6 43.2 40 80.2 59.7 81.7 72.7 100.6 55.4 101.7 68.4 123.3 63.5 124.2 76.5 2600 45 60.4 50.7 65.5 64.0 80.5 46.7 81.6 59.7 103.4 55.4 104.5 68.3 50 42.7 41.8 51.9 51.9 58.3 37.8 60.2 50.9 81.4 46.8 82.4 59.8 40 83.7 62.9 85.4 76.7 104.7 58.1 105.9 71.8 128.2 66.5 129.2 80.2 2800 45 63.1 53.6 68.8 67.5 83.9 49.1 85.0 62.9 107.7 58.1 108.7 71.9 30 5 /8 1 1 50 44.9 44.2 54.8 54.8 60.7 39.9 62.9 53.8 84.7 49.2 85.8 63.0 /8 40 86.9 65.9 88.8 80.5 108.7 60.6 109.8 75.2 132.8 69.3 133.8 83.8 3000 45 65.6 56.3 71.9 71.0 87.0 51.4 88.2 66.0 111.6 60.7 112.7 75.3 50 47.0 46.5 57.6 57.6 63.0 41.9 65.4 56.6 87.8 51.6 89.0 66.2 40 89.9 68.8 92.0 84.2 112.4 63.0 113.5 78.4 136.8 72.0 138.1 87.3 3200 45 68.0 59.0 74.9 74.3 90.0 53.6 91.2 69.0 115.3 63.2 116.4 78.5 50 49.0 48.7 60.3 60.3 65.2 43.8 67.8 59.3 90.8 53.8 92.0 69.2 40 108.8 81.9 111.1 99.8 136.0 75.6 137.4 93.5 116.2 86.4 167.3 104.2 3600 45 82.3 70.0 89.7 88.1 109.3 64.2 110.6 82.0 139.9 75.7 141.2 93.5 50 58.8 57.9 71.6 71.6 79.4 52.2 82.2 70.3 110.4 64.3 111.8 82.2 40 112.1 85.0 114.5 103.7 140.1 78.2 141.3 96.8 170.7 89.2 172.1 107.8 3800 45 84.9 72.8 92.6 91.6 112.5 66.5 113.9 85.2 143.9 78.3 145.2 97.0 40 7 /8 1 1 50 60.9 60.2 74.4 74.4 81.7 54.2 84.7 73.1 113.6 66.7 115.0 85.4 /8 40 115.2 88.0 117.8 107.5 143.8 80.7 145.1 100.1 174.8 92.0 176.3 111.4 4000 45 87.4 75.5 96.0 95.0 115.5 68.7 117.0 88.2 147.6 80.9 149.0 100.3 50 63.0 62.5 77.2 77.2 83.9 56.2 87.2 75.9 116.6 69.0 118.1 88.5 40 118.2 90.9 121.0 111.2 147.3 83.0 148.7 103.3 178.9 94.6 180.4 114.8 4200 45 89.8 78.1 99.0 98.3 118.4 70.9 119.9 91.2 151.2 83.3 152.7 103.6 50 65.0 64.7 79.9 79.9 86.1 58.1 89.5 78.6 119.5 71.2 121.1 91.5 *Capacity based on R-22 refrigerant at 105 F liquid temperature and 10 degrees F superheat. 12

LEGEND db Dry Bulb wb Wet Bulb SH Sensible TH Total Heat DIRECT EXPANSION (DX) BASE COOLING CAPACITIES* (MBtuh) (cont) 6-ROW COIL UNIT CONNECTION R-22 ENTERING AIR TEMPERATURE (F) db/wb SIZE SIZE (in.) CFM SUCTION 75/63 80/63 75/67 80/67 80/71 85/71 42BH Liquid Suction TEMP (F) TH SH TH SH TH SH TH SH TH SH TH SH 40 21.3 15.4 21.8 18.8 26.6 14.3 26.8 17.6 32.3 16.3 32.4 19.6 600 45 16.3 13.2 17.5 16.7 21.6 12.2 21.8 15.5 27.5 14.4 27.7 17.7 50 11.4 10.9 13.5 13.5 15.8 9.8 16.4 13.2 22.0 12.2 22.2 15.5 40 25.0 19.1 25.8 23.5 30.9 17.2 31.0 21.5 37.0 19.5 37.2 23.7 08 3/ 8 5/ 8 800 45 19.4 16.5 21.3 21.0 25.2 14.9 25.6 19.2 31.9 17.4 32.1 21.7 50 14.1 13.8 17.0 17.0 18.5 12.2 19.5 16.7 25.7 15.0 26.1 19.4 40 26.5 20.7 27.6 25.6 32.5 18.5 32.7 23.3 38.9 20.8 39.1 25.6 900 45 20.8 18.1 23.1 22.9 26.7 16.1 27.1 20.9 33.7 18.7 33.9 23.5 50 15.3 15.2 18.5 18.5 19.7 13.3 20.9 18.3 27.1 16.3 27.6 21.1 40 39.0 27.4 39.4 32.9 48.6 25.9 48.9 31.4 59.0 29.6 59.3 35.1 1000 45 30.0 23.3 31.4 29.0 39.7 21.9 40.0 27.4 50.4 25.9 50.7 31.4 50 21.1 19.2 23.8 23.8 29.7 17.7 30.3 23.3 40.6 21.9 41.0 27.4 40 43.7 31.5 44.3 38.0 54.1 29.4 54.6 35.8 65.6 33.4 65.9 39.8 12 7/ 8 1200 45 33.8 26.9 35.7 33.7 44.4 25.1 44.9 31.5 56.0 29.5 56.6 35.9 50 24.0 22.4 27.7 27.7 33.1 20.5 34.0 27.0 45.3 25.1 45.8 31.6 40 45.9 33.4 46.5 40.4 56.6 31.0 57.1 37.9 68.4 35.1 68.7 42.0 1300 45 35.5 28.7 37.6 35.9 46.5 26.5 47.0 33.5 58.6 31.1 59.2 38.0 50 25.4 24.0 29.6 29.6 34.9 21.8 35.7 28.8 47.4 26.6 47.9 33.5 40 52.8 37.6 53.5 45.3 65.9 35.4 66.3 43.1 80.1 40.5 80.5 48.1 1400 45 40.5 32.0 42.7 40.0 53.6 30.0 54.1 37.6 68.1 35.4 68.7 43.1 50 28.5 26.5 32.7 32.7 39.7 24.3 40.7 32.0 54.6 39.0 55.2 37.6 40 57.3 41.6 58.3 50.3 71.1 38.8 71.7 47.4 86.3 44.1 86.8 52.7 16 5/ 8 7/ 8 1600 45 44.1 35.6 46.9 44.6 58.1 33.0 58.7 41.7 73.6 38.9 74.2 47.5 50 31.3 29.6 36.5 36.5 43.1 26.9 44.3 35.7 59.2 33.1 59.7 41.7 40 61.4 45.3 62.6 55.0 75.9 41.9 76.6 51.4 91.8 47.5 92.3 57.0 1800 45 47.4 39.0 50.8 49.0 62.1 35.9 62.7 45.5 78.4 42.0 79.2 51.6 50 34.0 32.6 40.1 40.1 46.2 29.4 47.6 39.2 63.2 36.0 63.8 45.6 40 64.7 46.9 65.7 56.8 80.0 43.6 80.6 53.3 96.6 49.4 97.0 59.1 1800 45 50.2 40.3 53.1 50.5 65.8 37.3 66.4 47.1 82.9 43.7 83.6 53.4 50 35.7 33.6 41.5 41.5 49.3 30.6 50.5 40.5 67.2 37.4 67.8 47.2 40 68.7 50.6 70.0 61.5 84.6 46.6 85.3 57.3 101.9 52.7 102.4 63.3 20 5/ 8 7/ 8 2000 45 53.5 43.7 57.1 54.9 69.8 40.2 70.4 50.9 87.7 46.9 88.4 57.5 50 38.5 36.7 45.1 45.1 52.4 33.1 53.8 44.0 71.2 40.4 71.9 51.1 40 72.3 54.2 74.0 66.0 89.0 49.4 89.6 61.1 106.7 55.7 107.2 67.3 2200 45 56.5 47.0 60.8 59.1 73.4 42.8 74.1 54.5 92.1 49.8 92.8 61.4 50 41.1 36.9 48.5 48.5 55.2 35.5 56.9 47.4 74.8 43.1 75.6 54.8 40 101.1 71.9 102.4 86.2 126.1 68.1 126.9 82.3 153.4 77.9 154.2 92.1 2600 45 77.7 61.1 81.6 76.0 102.7 57.7 103.6 71.9 130.6 68.0 131.4 82.2 50 54.7 50.6 62.5 62.5 76.3 46.8 78.1 61.2 104.7 57.6 105.7 71.8 40 106.0 76.1 107.4 91.4 132.0 71.7 132.9 86.9 160.3 81.8 161.1 97.0 2800 45 81.6 64.9 86.0 80.8 107.5 60.9 108.5 76.1 136.2 71.7 137.5 86.8 30 5 / 8 1 1 / 50 57.7 53.9 66.4 66.4 80.0 49.5 81.9 65.0 109.5 60.8 110.6 76.0 8 40 110.6 80.1 112.2 96.4 137.2 75.1 138.4 91.2 166.7 85.5 167.6 101.6 3000 45 85.2 68.5 90.2 85.4 112.1 63.9 113.2 80.1 141.8 75.2 143.2 91.3 50 60.5 57.0 70.1 70.1 83.4 52.2 85.5 68.6 114.1 64.0 115.2 80.2 40 115.0 83.9 116.8 101.3 142.4 78.4 143.7 95.5 172.7 89.0 173.7 106.1 3200 45 88.7 72.0 94.2 89.9 116.4 66.9 117.6 84.0 147.1 78.5 148.5 95.6 50 63.3 60.1 73.8 73.8 86.6 54.7 89.0 72.2 118.4 67.0 119.6 84.1 40 136.5 98.3 138.2 118.0 168.6 92.0 169.6 111.5 203.1 104.1 203.9 123.6 3600 45 106.5 84.5 111.8 104.9 139.0 78.9 140.2 98.5 174.5 92.3 176.0 111.7 50 76.2 70.7 86.8 86.8 105.0 64.9 107.3 84.8 142.1 79.1 143.3 98.7 40 141.0 102.2 142.8 123.0 173.5 95.3 174.9 115.8 209.0 107.7 210.0 128.2 3800 45 110.1 88.1 115.9 109.5 143.5 82.0 144.7 102.5 179.8 95.6 181.4 116.1 40 7 / 8 1 1 / 50 79.0 73.9 90.7 90.7 108.4 67.6 110.9 88.4 146.6 82.2 147.9 102.8 8 40 145.2 106.1 147.3 127.8 178.5 98.5 179.9 119.9 214.7 111.1 215.7 132.5 4000 45 113.6 91.6 119.9 114.1 147.7 84.9 149.0 106.4 184.9 98.9 186.5 120.3 50 81.8 77.0 94.4 94.4 111.7 70.2 114.4 92.0 150.8 85.2 152.2 106.8 40 149.2 109.8 151.7 132.6 183.2 101.6 184.6 123.9 220.0 114.3 221.0 136.8 4200 45 116.9 95.1 123.8 118.5 151.8 87.7 153.1 110.3 189.7 102.0 191.4 124.4 50 84.5 80.1 98.1 98.1 114.9 72.7 117.7 95.6 154.9 88.1 156.3 110.7 *Capacity based on R-22 refrigerant at 105 F liquid temperature and 10 degrees F superheat. 13

Performance data (cont) 1. Contact factory if higher horsepower selection is required for a given CFM and total static pressure. 2. The variable pitch motor sheave provided will allow + 15% rpm adjustment. Unit sizes 08,12 and 16 have 3 /4 in. bore fan sheaves. Unit sizes 20, 30 and 40 have 1-in. bore fan sheaves. 3. Consult factory for motor selections when outlet air temperature exceeds 104 F on hot water coil applications. 4. Single-phase motors are only available to 2 hp. Three-phase motors are available from 1 / 2 to 3 hp. UNIT HORSEPOWER DATA TABLE TOTAL STATIC PRESSURE (0.5 to 2.0 in.wg) UNIT SIZE 42BH 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 CFM Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp Hp 600 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 700 1 / 4 1 / 4 1 / 4 1 / 4 1 / 4 1 / 4 1 / 3 1 / 3 1 / 3 1 / 3 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 08 800 1 /4 1 /4 1 /4 1 /4 1 /3 1 /3 1 /3 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 3 /4 900 1/ 4 1/ 4 1000 1 / 3 1 / 3 1 / 3 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 1000 1 /4 1 /4 1 /4 1 /3 1 /3 1 /3 1 /3 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 3 /4 3 /4 1100 1/ 4 1/ 4 12 1200 1 / 3 1 / 3 1 / 3 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 1300 1 /3 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 1 1400 1 1 1 1400 NA 1 / 3 1 / 3 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 1500 NA 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 16 1600 NA 1 1 1700 NA 1 / 2 1 / 2 1 / 2 1 / 2 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 1 1 1 1 1800 NA 1 /2 1 /2 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 1 1 1 1 1 1800 NA 1 1 1 1 1 1 1900 NA 1 / 2 1 / 2 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 1 1 1 1 1 1 1 1 / 2 2000 NA 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 1 1 1 1 1 1 1 1 /2 1 1 /2 1 1 /2 20 2100 NA 1 1 1 1 1 1 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2200 NA 3 / 4 3 / 4 3 / 4 1 1 1 1 1 1 1 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2300 NA 3 /4 3 /4 1 1 1 1 1 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 2400 NA 1 1 1 1 1 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2400 NA NA 3 / 4 3 / 4 1 1 1 1 1 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2600 NA NA 1 1 1 1 1 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 2 30 2800 NA NA 1 1 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2 2 2 3000 NA NA 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2 2 2 2 2 2 3200 NA NA 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 2 2 2 2 2 2 2 2 2 3400 NA NA 1 1 / 2 1 1 / 2 1 1 / 2 2 2 2 2 2 2 2 3 3 3 3 3400 NA NA 1 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2 2 2 2 2 2 3600 NA NA 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 1 1 /2 2 2 2 2 2 2 2 3 40 3800 NA NA 1 1 / 2 1 1 / 2 1 1 / 2 1 1 / 2 2 2 2 2 2 2 2 3 3 3 4000 NA NA 1 1 / 2 1 1 / 2 2 2 2 2 2 2 2 3 3 3 3 3 4200 NA NA 2 2 2 2 2 2 3 3 3 3 3 3 3 3 4400 NA NA 2 2 2 2 3 3 3 3 3 3 3 3 3 3 LEGEND NA Application not available Hp Horsepower 14

42BH COMPONENT STATIC RESISTANCE (in. wg) UNIT SIZE 42BH 08 12 16 20 30 40 WET COIL DRY COIL ONE-INCH (2) ONE-INCH CABINET 4 Row 6 Row 1 Row 2 Row 4 Row 6 Row PLEATED FILTER THROWAWAY FILTERS 600 0.04 0.18 0.27 0.02 0.04 0.08 0.13 0.08 0.04 0.06 700 0.06 0.25 0.37 0.03 0.06 0.12 0.17 0.10 0.06 0.08 800 0.08 0.32 0.49 0.04 0.08 0.15 0.23 0.14 0.08 0.11 900 0.10 0.41 0.61 0.05 0.10 0.19 0.29 0.17 0.10 0.14 1000 0.12 0.51 0.76 0.06 0.12 0.24 0.35 0.21 0.12 0.17 NOMINAL CFM TWO-INCH PLEATED FILTER 1000 0.06 0.24 0.36 0.03 0.06 0.11 0.17 0.11 0.06 0.09 1100 0.08 0.29 0.44 0.03 0.07 0.14 0.20 0.14 0.08 0.11 1200 0.09 0.35 0.52 0.04 0.08 0.16 0.24 0.16 0.09 0.13 1300 0.11 0.41 0.61 0.05 0.09 0.19 0.28 0.19 0.11 0.15 1400 0.13 0.47 0.71 0.05 0.11 0.22 0.33 0.22 0.13 0.17 1400 0.07 0.26 0.39 0.03 0.06 0.12 0.18 0.13 0.07 0.10 1500 0.09 0.30 0.45 0.03 0.07 0.14 0.21 0.15 0.09 0.12 1600 0.10 0.34 0.51 0.04 0.08 0.16 0.24 0.17 0.10 0.13 1700 0.11 0.38 0.58 0.04 0.09 0.18 0.27 0.19 0.11 0.15 1800 0.12 0.43 0.65 0.05 0.10 0.20 0.30 0.21 0.12 0.17 1800 0.12 0.30 0.45 0.03 0.07 0.14 0.21 0.13 0.08 0.10 1900 0.13 0.34 0.50 0.04 0.08 0.16 0.23 0.14 0.08 0.12 2000 0.14 0.37 0.56 0.04 0.09 0.17 0.26 0.16 0.09 0.13 2100 0.16 0.41 0.61 0.05 0.10 0.19 0.29 0.18 0.10 0.14 2200 0.17 0.45 0.67 0.05 0.10 0.21 0.31 0.19 0.11 0.16 2300 0.19 0.49 0.74 0.06 0.11 0.23 0.34 0.21 0.12 0.17 2400 0.21 0.54 0.80 0.06 0.12 0.25 0.37 0.23 0.13 0.19 2400 0.11 0.22 0.33 0.03 0.05 0.10 0.15 0.13 0.07 0.10 2600 0.13 0.25 0.38 0.03 0.06 0.12 0.18 0.15 0.09 0.12 2800 0.15 0.29 0.44 0.03 0.07 0.14 0.21 0.17 0.10 0.14 3000 0.18 0.34 0.51 0.04 0.08 0.16 0.24 0.20 0.12 0.16 3200 0.20 0.39 0.58 0.04 0.09 0.18 0.27 0.23 0.13 0.18 3400 0.23 0.43 0.65 0.05 0.10 0.20 0.30 0.25 0.15 0.20 3400 0.13 0.24 0.36 0.03 0.06 0.11 0.17 0.15 0.09 0.12 3600 0.15 0.27 0.40 0.03 0.06 0.12 0.19 0.16 0.10 0.13 3800 0.16 0.30 0.45 0.03 0.07 0.14 0.21 0.18 0.11 0.15 4000 0.18 0.33 0.50 0.04 0.08 0.15 0.23 0.20 0.12 0.16 4200 0.20 0.36 0.55 0.04 0.08 0.17 0.25 0.22 0.13 0.18 4400 0.22 0.40 0.60 0.05 0.09 0.19 0.28 0.25 0.14 0.20 Hydronic coil pressure drop All of the factory s hydronic coils have a coefficient of velocity (Cv) resistance factor assigned to assist in a more accurate determination of water pressure drop (see Cv Factor by Coil and Unit Size table below). Calculating pressure drop: The Cv factor is equal to the flow rate of water in GPM through a piping component when the pressure drop through the component is 1.0 pounds per square inch (psi), or 2.31 ft wg. P (ft wg) = P (psi) x 2.31 Use the Cv factor from the Cv Factor by Coil and Unit Size table to determine the water coil pressure drop. Coil pressure drop (ft wg): P = (GPM 2 /Cv 2 ) x 2.31 or P = [GPM/(0.658 x Cv)] 2 or Refer to the Water Pressure Drop for Cv Factor and Water Flow Rate table. See example on page 7. CV FACTOR BY COIL AND UNIT SIZE COIL TYPE 42BH 42BH UNIT SIZE/CV FACTOR 08 12 16 20 30 40 1 Row Heat Only 1.4 1.3 1.2 1.2 0.8 0.7 2 Row Heat Only 2.4 2.2 2.0 1.9 1.6 1.4 4 Row Heat/Cool 4.7 4.4 7.2 6.8 13.2 12.4 6 Row Heat/Cool 4.0 3.7 6.1 5.8 11.4 10.5 1201 15

Performance data (cont) 42BH WATER PRESSURE DROP (ft. wg) FOR CV FACTOR AND WATER FLOW RATE (GPM) Cv WATER FLOW RATE (GPM) FACTORS 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 110 11.5 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 0.8 0.9 3.6 8.1 14.4 22.5 32.4 0.9 0.7 2.8 6.4 11.4 17.8 25.6 34.9 1.0 0.5 2.3 5.2 9.2 14.4 20.7 28.2 36.9 1.1 0.4 1.9 4.2 7.6 11.9 17.1 23.3 30.5 1.2 1.6 3.6 6.4 10.0 14.4 19.6 25.6 32.4 1.3 1.3 3.0 5.4 8.5 12.3 16.7 21.8 27.6 34.1 1.4 1.1 2.6 4.7 7.3 10.6 14.4 18.8 23.8 29.4 1.5 1.0 2.3 4.1 6.4 9.2 12.5 16.4 20.7 25.6 31.0 1.6 0.9 2.0 3.6 5.6 8.1 11.0 14.4 18.2 22.5 27.2 32.4 1.7 0.8 1.8 3.2 4.9 7.1 9.7 12.7 16.1 19.9 24.1 28.7 33.7 1.8 0.7 1.6 2.8 4.4 6.4 8.7 11.4 14.4 17.8 21.5 25.6 30.1 1.9 0.6 1.4 2.5 4.0 5.7 7.8 10.2 12.9 15.9 19.3 23.0 27.0 31.3 2.0 0.5 1.3 2.3 3.6 5.2 7.0 9.2 11.6 14.4 17.4 20.7 24.4 28.2 32.4 2.1 0.5 1.1 2.0 3.2 4.7 6.4 8.3 10.6 13.0 15.8 18.8 22.1 25.6 29.4 33.5 2.2 0.4 1.0 1.9 2.9 4.2 5.8 7.6 9.6 11.9 14.4 17.1 20.1 23.3 26.8 30.5 2.3 0.9 1.7 2.7 3.9 5.3 6.9 8.8 10.9 13.2 15.7 18.4 21.3 24.5 27.9 31.5 2.4 0.9 1.6 2.5 3.6 4.9 6.4 8.1 10.0 12.1 14.4 16.9 19.6 22.5 25.6 28.9 32.4 2.5 0.8 1.4 2.3 3.3 4.5 5.9 7.4 9.2 11.1 13.3 15.6 18.1 20.7 23.6 26.7 29.9 33.3 2.6 0.7 1.3 2.1 3.0 4.1 5.4 6.9 8.5 10.3 12.3 14.4 16.7 19.2 21.8 24.6 27.6 30.8 2.7 0.7 1.2 1.9 2.8 3.8 5.0 6.4 7.9 9.5 11.4 13.3 15.5 17.8 20.2 22.8 25.6 28.5 31.6 2.8 0.6 1.1 1.8 2.6 3.6 4.7 5.9 7.3 8.9 10.6 12.4 14.4 16.5 18.8 21.2 23.8 26.5 29.4 32.4 2.9 0.6 1.1 1.7 2.4 3.3 4.3 5.5 6.8 8.3 9.8 11.6 13.4 15.4 17.5 19.8 22.2 24.7 27.4 30.2 3.0 0.5 1.0 1.6 2.3 3.1 4.1 5.2 6.4 7.7 9.2 10.8 12.5 14.4 16.4 18.5 20.7 23.1 25.6 28.2 31.0 3.2 0.5 0.9 1.4 2.0 2.7 3.6 4.5 5.6 6.8 8.1 9.5 11.0 12.6 14.4 16.3 18.2 20.3 22.5 24.8 27.2 29.8 3.4 0.8 1.2 1.8 2.4 3.2 4.0 4.9 6.0 7.1 8.4 9.7 11.2 12.7 14.4 16.1 18.0 19.9 22.0 24.1 26.4 28.7 3.6 0.7 1.1 1.6 2.1 2.8 3.6 4.4 5.3 6.4 7.5 8.7 10.0 11.4 12.8 14.4 16.0 17.8 19.6 21.5 23.5 25.6 30.1 3.8 0.6 1.0 1.4 1.9 2.5 3.2 4.0 4.8 5.7 6.7 7.8 9.0 10.2 11.5 12.9 14.4 15.9 17.6 19.3 21.1 23.0 27.0 31.3 4.0 0.5 0.9 1.3 1.7 2.3 2.9 3.6 4.3 5.2 6.1 7.0 8.1 9.2 10.4 11.6 13.0 14.4 15.9 17.4 19.0 20.7 24.4 28.2 4.2 0.5 0.8 1.1 1.6 2.0 2.6 3.2 3.9 4.7 5.5 6.4 7.3 8.3 9.4 10.6 11.8 13.0 14.4 15.8 17.3 18.8 22.1 25.6 29.4 4.4 0.4 0.7 1.0 1.4 1.9 2.4 2.9 3.6 4.2 5.0 5.8 6.7 7.6 8.6 9.6 10.7 11.9 13.1 14.4 15.7 17.1 20.1 23.3 26.8 30.5 4.6 0.6 0.9 1.3 1.7 2.2 2.7 3.3 3.9 4.6 5.3 6.1 6.9 7.8 8.8 9.8 10.9 12.0 13.2 14.4 15.7 18.4 21.3 24.5 27.9 31.5 4.8 0.6 0.9 1.2 1.6 2.0 2.5 3.0 3.6 4.2 4.9 5.6 6.4 7.2 8.1 9.0 10.0 11.0 12.1 13.2 14.4 16.9 19.6 22.5 25.6 28.9 5.0 0.5 0.8 1.1 1.4 1.8 2.3 2.7 3.3 3.9 4.5 5.2 5.9 6.6 7.4 8.3 9.2 10.1 11.1 12.2 13.3 15.6 18.1 20.7 23.6 26.7 29.9 5.3 0.5 0.7 1.0 1.3 1.6 2.0 2.4 2.9 3.4 4.0 4.6 5.2 5.9 6.6 7.4 8.2 9.0 9.9 10.8 11.8 13.9 16.1 18.5 21.0 23.7 26.6 29.6 5.6 0.4 0.6 0.9 1.1 1.4 1.8 2.2 2.6 3.1 3.6 4.1 4.7 5.3 5.9 6.6 7.3 8.1 8.9 9.7 10.6 12.4 14.4 16.5 18.8 21.2 23.8 26.5 29.4 5.9 0.6 0.8 1.0 1.3 1.6 2.0 2.3 2.8 3.2 3.7 4.2 4.7 5.3 5.9 6.6 7.3 8.0 8.7 9.5 11.2 13.0 14.9 16.9 19.1 21.5 23.9 26.5 6.2 0.5 0.7 0.9 1.2 1.5 1.8 2.1 2.5 2.9 3.3 3.8 4.3 4.8 5.4 6.0 6.6 7.2 7.9 8.6 10.1 11.7 13.5 15.3 17.3 19.4 21.6 24.0 6.5 0.4 0.6 0.8 1.1 1.3 1.6 1.9 2.3 2.6 3.0 3.5 3.9 4.4 4.9 5.4 6.0 6.6 7.2 7.8 9.2 10.7 12.3 13.9 15.8 17.7 19.7 21.8 6.8 0.6 0.8 1.0 1.2 1.5 1.8 2.1 2.4 2.8 3.2 3.6 4.0 4.5 4.9 5.5 6.0 6.6 7.1 8.4 9.7 11.2 12.7 14.4 16.1 18.0 19.9 7.1 0.5 0.7 0.9 1.1 1.3 1.6 1.9 2.2 2.5 2.9 3.3 3.7 4.1 4.5 5.0 5.5 6.0 6.6 7.7 8.9 10.3 11.7 13.2 14.8 16.5 18.3 7.5 0.5 0.6 0.8 1.0 1.2 1.4 1.7 2.0 2.3 2.6 2.9 3.3 3.7 4.1 4.5 4.9 5.4 5.9 6.9 8.0 9.2 10.5 11.8 13.3 14.8 16.4 8.0 0.5 0.7 0.9 1.0 1.3 1.5 1.7 2.0 2.3 2.6 2.9 3.2 3.6 3.9 4.3 4.7 5.2 6.1 7.0 8.1 9.2 10.4 11.6 13.0 14.4 8.5 0.5 0.6 0.8 0.9 1.1 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.2 3.5 3.8 4.2 4.6 5.4 6.2 7.1 8.1 9.2 10.3 11.5 12.7 9.0 0.4 0.5 0.7 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.3 2.5 2.8 3.1 3.4 3.7 4.1 4.8 5.5 6.4 7.3 8.2 9.2 10.2 11.4 9.5 0.5 0.6 0.7 0.9 1.0 1.2 1.4 1.6 1.8 2.0 2.3 2.5 2.8 3.1 3.3 3.6 4.3 5.0 5.7 6.5 7.4 8.2 9.2 10.2 10.0 0.4 0.5 0.7 0.8 0.9 1.1 1.3 1.4 1.6 1.8 2.0 2.3 2.5 2.7 3.0 3.3 3.9 4.5 5.2 5.9 6.6 7.4 8.3 9.2 10.5 0.5 0.6 0.7 0.8 1.0 1.1 1.3 1.5 1.7 1.8 2.0 2.3 2.5 2.7 3.0 3.5 4.1 4.7 5.3 6.0 6.7 7.5 8.3 11.0 0.4 0.5 0.6 0.8 0.9 1.0 1.2 1.3 1.5 1.7 1.9 2.1 2.3 2.5 2.7 3.2 3.7 4.2 4.8 5.5 6.1 6.8 7.6 11.5 0.5 0.6 0.7 0.8 0.9 1.1 1.2 1.4 1.5 1.7 1.9 2.1 2.3 2.5 2.9 3.4 3.9 4.4 5.0 5.6 6.3 6.9 12.0 0.4 0.5 0.6 0.7 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.9 2.1 2.3 2.7 3.1 3.6 4.1 4.6 5.2 5.7 6.4 13.0 0.4 0.5 0.6 0.7 0.8 0.9 1.1 1.2 1.3 1.5 1.6 1.8 1.9 2.3 2.6 3.0 3.5 3.9 4.4 4.9 5.4 14.0 0.5 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.3 1.4 1.5 1.7 1.9 2.3 2.6 3.0 3.4 3.8 4.2 4.7 15.0 0.5 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.7 2.0 2.3 2.6 2.9 3.3 3.7 4.1 16.0 0.5 0.5 0.6 0.7 0.8 0.9 0.9 1.0 1.1 1.3 1.5 1.7 2.0 2.3 2.6 2.9 3.2 3.6 17.0 0.5 0.5 0.6 0.7 0.8 0.8 0.9 1.0 1.1 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.2 18.0 0.4 0.5 0.5 0.6 0.7 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.8 2.0 2.3 2.5 2.8 19.0 0.4 0.5 0.5 0.6 0.7 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.8 2.0 2.3 2.5 20.0 0.4 0.5 0.5 0.6 0.7 0.7 0.8 0.9 1.1 1.3 1.4 1.6 1.8 2.0 2.3 NOTE: Table interpolation is permissible, and extrapolation is not recommended. 16