AAMA/WDMA/CSA 101/I.S.2/A440-08

Similar documents
AAMA/WDMA/CSA 101/I.S.2/A440-08

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Québec) J3X 1P7 Tél. : (450) Fax : (450)

New Gateway 101/I.S.2/A440

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

AAMA/WDMA/CSA 101/I.S.2/A NAFS North American Fenestration Standard/Specification for windows, doors, and skylights

Contents. Preface 6. 1 Scope General Outside of scope Terminology Units of measurement 13 1.

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

Product Guide Specification

ALUMINUM HORIZONTAL ROLLER WINDOW

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

Product Guide Specification

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Aluminum Wood Double-Hung Windows

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

General Information SECTION DIRECTORY

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

Warranty, Parts & Install Info 1. Series 4600 Double Hung Windows 2. Series 4710 Casement Windows 3. Series 9000 Sliding Patio Door 4

continuous mounting flange intended for direct attachment to roofing substrate.

Guide Specification SECTION VINYL WINDOWS

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

Sliding Patio Doors Builders Vinyl

Aluminum Series SH600 Product Specifications

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Visions 3000 Series 924 Parts Catalog

Note: PGT reserves the right to change material design and/or construction without notice or liability Window Height

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

A. This Section includes the following types of sectional overhead doors:

DF COLLECTION. Architectural Detail Guide Hybrid Awning Window DF 3113 TABLE OF CONTENTS

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

400 Series Gliding Windows (1991 to Present)

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

400 Series Gliding Windows (1991 to Present)

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

Sliding Windows Brickmould Vinyl

81870 Alside_24667 Alside 11/3/16 5:01 PM Page 2 80 Series

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES LOW PROFILE FIXED. Dominion Doors & Windows Ltd.

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

400 Series Gliding Windows (1991 to Present)

Specifications... Quick Spec Guide...

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES CASEMENT WINDOW. Dominion Doors & Windows Ltd.

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

WA67 Folding System - Aluminum Clad Over Wood

Visions 2000 Double Hung Tilt Window Parts Reference Catalog

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

Submittal Requirements for Product Evaluation - Doors

American National Standard

Sliding Patio Doors Flat Casing Vinyl

Eclipse C3 Aluminum Folding Door System. Dealer Brochure Exterior folding door systems

V3 Series Awning Windows (2011 to Present)

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

Sliding Windows Builders Vinyl

500 SERIES REINFORCED WOOD FRAME FOR EASY INSTALLATION

TM MANUFACTURERS

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

ROLLER SHADE SPECIFICATIONS

Double Hung. Power Lift 28,000 Constant Force

SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT

Superior by Design EURO (3876)

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

BIRDVIEW SKYLIGHTS The Clear Choice

1010C Sliding Mall Front

SECTION SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Casement Windows Builders Clad-Wood

DASMA DASMA

Evidence of Performance Burglar resistance

VINYL WINDOWS & DOORS

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

ROLLER SHADE SPECIFICATIONS

37, gr/m 46,8 24,8 48,8 73,8 73, gr/m 93,9 71, gr/m 93,9 71, gr/m 71,4 88,9 39,9

CHAPTER 3 INTEGRITY WOOD ULTREX DOUBLE HUNG

HURRICANESHIELD IMPACT-RESISTANT GLASS SECTION DIRECTORY. Size and performance summary. Glazing performance. Grille profiles and patterns.

260/360/560 INSULCLAD ENTRANCES

Reliance BlastMax Blast Resistant Curtain Wall Wet Glazed

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION

ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

INSTALLATION INSTRUCTIONS

Perma-Shield Gliding Patio Doors

Single-Hung Tilt Windows Builders Vinyl

Meeting ENERGY STAR Version 6.0

Section Traffic Doors

BELVEDERE PROJECT TECHNICAL GUIDE ACCESS WINDOWS

Moisture prevention. Eco friendly. Will not mould. Heat/cold resistance. Buckingham. Eco-Series Patio Door

cero by NanaWall The Minimal Framed Large Panel Sliding Glass Wall

Pella 450 Series. Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data

DOUBLE/SINGLE HUNG WINDOWS

ThermaSeal TM220 SECTIONAL OVERHEAD DOORS

Ariel Sliding Patio Doors

The Falcon Series... Setting The Standard

Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors

EXTRUDED ALUMINUM BALANCED DOORS AND ENTRANCES

350/500 Tuffline TM Entrances 1

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

Transcription:

PERFORMANCE TESTS IN ACCORDANCE WITH AAMA/WDMA/CSA 101/I.S.2/A440-08 Product Manufacturer: Report No.: AI-04016-U1 Rev.1 ACRYLON PLASTICS 122 PAQUIN ROAD WINNIPEG, MANITOBA R2J 3V4 204-669-2345 Report Summary: Product type: Product series/model: Primary product designator: Optional secondary designator: completion date: Report date: Revision date: Number of pages: PVC Horizontal Sliding Window GP111 Series Single Slider, 3 1/4" Frame Class R-PG25-HS Size tested 1600 x 1099 (63 x 43) Positive Design pressure (DP) = 1680 Pa (35.0 psf) Negative design pressure (DP) = -1680 Pa (-35.0 psf) Water penetration resistance test pressure = 180 Pa (3.75 psf) Canadian air infiltration / exfiltration level = A2 Level 02/07/2013 11/11/2013 12/17/2013 8 Note: Reference must be made to Air-Ins Inc. complete report for test specimen description and detailed test results. Prepared by : Approved by : Digitally Signed by: Digitally Signed by: Jean Miller, Eng. Robert Jutras, Eng. Director, Physical ing Department President, Air-Ins Inc. Air-Ins Inc. AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Québec) J3X 1P7 (450) 652-0838 (450) 652-7588 info@air-ins.com

TABLE OF CONTENTS 1.0 INTRODUCTION...1 2.0 DESCRIPTION OF THE SPECIMEN TESTED...1 3.0 ALTERATION(S)...5 4.0 TEST BENCH INFORMATION...5 5.0 RESULTS OF PERFORMANCE TESTS...6 5.1 TEST SPECIMEN PRIMARY TESTING...6 5.2 TEST SPECIMEN AUXILIARY TESTING...7 6.0 CONCLUSION...8 Air-ins Inc

PERFORMANCE TESTS IN ACCORDANCE WITH AAMA/WDMA/CSA 101/I.S. 2/A440-08 1.0 INTRODUCTION Air-Ins Inc. laboratory was retained by " Acrylon Plastics " to test a window according to the performance levels in the AAMA/WDMA/CSA 101/I.S.2/A440-08 Standard. The sample components and manufacturing are documented in section 2.0. Note concerning the use of units of measurement in this report: According to the AAMA/WDMA/CSA 101/I.S.2/A440-08 Standard, the use of SI (metric) units is the standard, while IP (Imperial) values given in parentheses are for reference purposes only, and are inexact rounded values. Section 5.0 contains testing results converted to IP units for the sake of convenience only. The only exception to using Si values is in the Performance Grade (PG) portion of the product designation. Note concerning drawings: The drawings reviewed for the production of this report are stamped and are on file at Air-Ins Inc. The availability of individual drawings will be at the discretion of the client. 2.0 DESCRIPTION OF THE SPECIMEN TESTED Type: Horizontal Sliding, type A of AAMA/WDMA/CSA 101/I.S. 2/A440-08. - Number of sashes: (1) operable sash Model: Single slider 3-1/4 framing (GP111SS) Assembly drawings: Single slider 3-1/4 framing (GP111SS) Drawings reviewed: Parts no.: GP103, GP111, GP112, GP106, TSH02, TSH07, TSH28 and TSH08. Air-ins Inc. 1/8

Date of CSA audit: None Date(s) of sample reception: 01/29/2013 Date(s) of testing: 02/04/2013 to 02/07/2013 specimen installation (test buck): - Material: Eastern Pine (2 x 6 ) - Rough opening clearances: None - Fastening: Screws # 8-2 trough wood buck 8/Rails, 5/Stiles. - Sealing detail: Sealant between test buck and specimen on exterior side only. Frame : - Material: Extruded P.V.C. - Assembly method: Mitre cut, thermally welded - Head, sill and jambs: Extrusion no. GP101 - Sill rail: Extrusion no. GP112 - Interlock mullion: Extrusion no. TSH02 - Water deflector: Extrusion no. GP106 - Overall dimensions: 1598 mm width x 999 mm height Sash: - Material: Extruded P.V.C. - Assembly method: Mitre cut, thermally welded - Sash perimeter: Extrusion no. GP103 - Pull handle: Extrusion no. TSH08 - Meeting adaptor: Extrusion no. TSH28 - Glazing stops: Extrusion no. TSH07 - Overall dimensions: 796 mm width x 933 mm height Hardware: - Cam locks: (2) 08703BG (Servitek) - Keepers: (2) 08703KB (Servitek) Air-ins Inc. 2/8

Weatherstripping: (see assembly drawings) Sash: - EZ FIN 1821-80V6-1 (SSI) at stile rails and top rail. - FS-7322-187 (Schlegel) at meeting rail. Frame: - FS-7325-187 (Schlegel) at mullion. - FS-7330-187 (Schlegel) at sill, head, jamb and water deflector of frame. Dust plugs: (see assembly drawings): Sash: - Dust plug 16 mm (L) x 30 mm (l) x 3.5 mm (h) installed at both extremities of meeting stile. - Foam block 12 mm (L) x 25 mm (l) x 8 mm (h) installed in the groove of sash at the meeting stile level. Frame: - Dust plug 25 mm (L) x 38 mm (l) x 15 mm (h) stuck into the head frame interior groove at meeting rail level. - Dust plug 25 mm (L) x 16 mm (l) x 6.5 mm (h) stuck on the sill rail at the meeting rail level. - Foam block 13.5 mm (L) x 38 mm (l) x 10 mm (h) at extremities of the sill rail at jamb level. Sealant: Sash: - Sealant at lower rail of sash and continue on 100 mm at stiles, before glazing stops installation. - Sealant on 2 x 100 mm at centre part of stiles, before glazing stop installation. - Sealant on 2 x 300 mm between the both glazing seal, on each stile and rail, before sealed unit installation. - Sealant at junctions of glazing stops (Alteration #1). Frame: - Sealant at sill and continue on 150 mm at jamb and mullion, before glazing stops installation (fixed part). - Sealant on 125 mm at centre part of jamb and mullion, before glazing stop installation. - Sealant on 2 x 300 mm between the both glazing seal, at jamb, sill and head, before sealed unit installation. - Sealant at mullion junctions with head and sill. Air-ins Inc. 3/8

Glazing method: - Glazing:With glazing stops. Weatherstripping: Interior side: 2 soft P.V.C. co-extruded on the glazing stop extrusion. Exterior side: 2 soft co-extruded fin on the sash extrusion. 2 soft coextruded fin on the jamb, sill and head extrusions (fixed part). Glazing tape on mullion (Profoam #614-C-K). Setting block: - 3 blocks at stiles - 3 blocks at inferior rail. Glazing: - Type: Dual glazed insulated glass unit - Total thickness: 22 mm - Glass thickness: 3 mm (interior, exterior) - Type of glass: Clear annealed - Type of spacer: Inex - Type of filling gas: Air Drainage holes or drainage system: (see drawings) Frame: - 2 slots (6.5 mm x 32 mm) in front of frame for the drainage of the space under the moving sash, with flaps. - 2 slots (6.5 mm x 32 mm) at the bottom of screen, with flaps (Alteration #2). - 2 slots (3 mm x 15 mm) in the sill inner groove. - 1 hole (5.5 mm ø) and 1 slot (15.5 mm x 4.5 mm) for fixed part drainage. - 1 slot (22 mm x 15 mm) in the sill rail, at meeting stile level. The sill rail is shorter by 5 mm at both extremities for drainage. Sash: 2 slots of (4.7 mm ). Screen: - Frame materials: Rolled aluminum - Mesh materials: Fiberglass - Anchoring method: Channelled at stiles. Air-ins Inc. 4/8

- Auxiliary parts: - 4 assembly braces - 2 nylon handles - 2 springs - 2 shims 6.3 mm thick. - Overall dimensions: 718 mm width x 862 mm height 3.0 ALTERATION(S) Alteration(s) performed in the laboratory on tested specimen to meet the reported performances: Water tightness: (1) Sealant at junctions of glazing stops. (2) Addition of 2 slots (3 mm x 12 mm) in front of frame for screen cavity drainage. The initial slots for the drainage in the inner cavity of sill were blocked. 4.0 TEST BENCH INFORMATION Information regarding the Bench and related instrumentation used for testing: bench identification: TB-02-GC. The calibration of this test bench was done as per Article 9.0 of ASTM E283, Standard Method for Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors, and ASTM E331 Standard Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference and ASTM E547 Standard Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Cycling Static Air Pressure Difference. The last calibration of this test bench and related equipment was performed in January, 2013. Air-ins Inc. 5/8

5.0 RESULTS OF PERFORMANCE TESTS 5.1 TEST SPECIMEN PRIMARY TESTING R TEST CLASS SPECIFICATIONS TEST RESULTS GRADE OR COMMENT U.S. (only)requirements: Force to initiate motion: Reported only Force to maintain motion < 90 N (20 lbf) Force to latch< 100 N (22.5 lbf) Canadian (only)requirements: Operating Force Force to initiate motion: (normal use)< 90 N (20 lbf) (cleaning/maintenance)< 180 N (40 lbf) Force to maintain motion: Measured to initiate = 71.2 N (16 lbf) Measured to maintain = 44.5 N (10 lbf) Measured to latch = 4.5 N (1.0 lbf) (normal use)< 45 N (10 lbf) (cleaning/maintenance)< 115 N (25 lbf) Force to latch< 100 N (22.5 lbf) AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.1.1 & ASTM-E2068-00 Air Leakage Resistance Qinf 1.5 l/s-m² @ 75 Pa ( 0.3 cfm/ft 2 @ 1.57 psf ) AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.2.1 & ASTM-E283-04 Canadian air infiltration/exfiltration level: A2: Qinf & exf 1.5 l/s-m² @ 75 Pa ( 0.3 cfm/ft 2 @ 1.57 psf ) A3: Qinf & exf 0.5 l/s-m² @ 75 Pa ( 0.1 cfm/ft 2 @ 1.57 psf) AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.2.2 & ASTM-E283-04 Surface: 1.76 m 2 (18.93 ft 2 ) Qinf = 0.60 l/s-m² @ 75 Pa (0.12 cfm/ft 2 @ 1.57 psf ) Qinf = 0.60 l/s-m² @ 75 Pa (0.12 cfm/ft 2 @ 1.57 psf ) Qexf = 0.55 l/s-m² @ 75 Pa (0.11 cfm/ft 2 @ 1.57 psf ) Qavg = 0.58 l/s-m² @ 75 Pa (0.11 cfm/ft 2 @ 1.57 psf ) A2 level Water Resistance Uniform Load Deflection No water infiltration under a minimum pressure differential of 140 Pa (2.90 psf) AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.3.2 & ASTM-E547-00 Deflection at 720 Pa (15.00 psf) minimum class level and at optional Design Pressure (DP) performance level. AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.4.2 & ASTM-E330-02 No water infiltration under a pressure differential of 180 Pa (3.75 psf ) with and without insect screen. Net deflection measured on the meeting stile: 4.75 mm @ 720 Pa (0.18 " @ 15.00 psf) 4.79 mm @ +720 Pa (0.18 " @ +15.00 psf) 13.13 mm @ 1680 Pa (0.51 " @ 35.00 psf) 12.33 mm @ +1680 Pa (0.48 " @ +35.00 psf) Net deflection measured on the top rail: 2.12 mm @ 720 Pa (0.08 " @ 15.00 psf) 3.33 mm @ +720 Pa (0.13 " @ +15.00 psf) 2.92 mm @ 1680 Pa (0.11 " @ 35.00 psf) 9.29 mm @ +1680 Pa (0.36 " @ +35.00 psf) 25 Reported only Allowed: Not applicable for this performance class Air-ins Inc. 6/8

Uniform Load Structural Permanent deformation 0.4% of the member span at minimum class level of 1080 Pa (22.5 psf) and at optional Structural Pressure (STP) levels. AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.4.3 & ASTM-E330-02 Permanent deformation measured on the meeting stile: 0.82 mm @ 1080 Pa (0.03 " @ 22.50 psf) 0.98 mm @ +1080 Pa (0.03 " @ +22.50 psf) 1.90 mm @ 2520 Pa (0.07 " @ 52.50 psf) 2.29 mm @ +2520 Pa (0.09 " @ +52.50 psf) Allowed 3.84 mm (0.15 ") Permanent deformation measured on the top rail: 0.14 mm @ 1080 Pa (0.00 " @ 22.50 psf) 0.49 mm @ +1080 Pa (0.01 " @ +22.50 psf) 0.33 mm @ 2520 Pa (0.01 " @ 52.50 psf) 1.15 mm @ +2520 Pa (0.04 " @ +52.50 psf) Allowed 2.95 mm (0.11 ") 35 Forced- Entry Resistance All windows shall be tested according to ASTM F588-04 performance level 10. AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.5 Grade 20 of ASTM F588-04 T1=5 min., L1=890 N (200 lbf), L2=445 N (100 lbf) & L3=155 N (35 lbf) 5.2 TEST SPECIMEN AUXILIARY TESTING R TEST CLASS SPECIFICATIONS TEST RESULTS GRADE OR COMMENT Welded Corner Deglazing Insect Screen When loaded to failure, the break shall not extend along the entire weld line. AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.6.2 Deglazing < 90% of original glazing bite. The load for vertical sash members is 320 N (70 lbf) and 230 N (50 lbf) for all other rails. AAMA/WDMA/CSA 101/I.S.2/A440-08 par. 5.3.6.3 & ASTM E987-88(2001) Canadian (only)requirements: Insect screens shall be tested in accordance with ASTM E1748 in the outward direction only under a load of 60 N (13 lbf). A440S1-09 Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440 par. 5.1 For each corner detail (sash and frame) the breakage does not extend along the entire weld line. Allowed: 14.4 mm (0.56")/ 90 % Measured: 1.5 mm (0.06")/ 10 % for stiles Measured: 1.0 mm (0.04") / 7 % for rails No screen disengagement or permanent deformation under a 60 N (13 lbf ) load. Air-ins Inc. 7/8

6.0 CONCLUSION Based on the tests results, the window described in this report meets the requirements of the AAMA/WDMA/CSA 101/I.S. 2/A440-08 Standard regarding performance testing (article 5.0). Detailed assembly drawings showing wall thickness of all members, corner construction and hardware application are on file and have been compared to the sample submitted. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the referenced specification. The test records from this evaluation will be retained for a minimum of four (4) years from the date of report issuance. This report does not constitute certification of this product, which may only be granted by a certification agency. Note on the Limitation of Liability: Due care was taken in performing the testing sequence and in reporting the results related to the test specimen received for evaluation. Through acceptance of this report, the Client agrees to exempt Air-Ins Inc. employees and owners from all liability claims and demands arising from any matter related to or concerning the quality and execution of the performance evaluation contained in this report. Air-ins Inc. 8/8