Vogel - Inline Pumps Design LR / LMR & LRZ / LMZ, LER & LEZ 1
Performance: Capacity up to 350 m 3 /h (1540 USgpm) Head up to 85 m (280 feet) Speed up to 2950 min -1 (2950 rpm) Pump sizes: DN 40 up to DN 150 (1 1/2 up to 6 ) discharge, pumps with higher capacities, sizes DN 200 up to DN 300 (8 up to 12 ), refer to design LER / LEZ, page 12. Temperature of pumped liquid: max. 140 C (284 F) Design LR, LMR Casing pressure: Materials: Design LMZ Design LR: up to 16 bar/120 C or 13 bar/140 C Design LMR/LMZ: up to 16 bar/120 C or 13 bar/140 C Liquids: Clean and slightly contaminated fluids (without bigger solids) Cold and hot water Condensate Water-Glycol mixtures, etc. Applications: Water supply and water treatment Cooling and hot water supply in industries and building services Filter systems, etc. Design Code Size Impeller Casing, Seal chamber Wear rings Motor adapter Shaft LR LRZ VN 40-125 up to 80-160 1.4404 NN 80-200 0.6020 up to SN 100-250 2.1050.01 0.6020 1.4402 1) 0.6020 1.4401 LMR LMZ NN DN 125 0.6025 up to SN DN 150 2.1050.01 0.6025 1) 0.6025 1.4021 1) optional 0.6020 bzw. 0.6025 2
Performance 2900 r.p.m., Design LR 3
Performance 1450 r.p.m., Design LR / LMR 4
Performance 2900 r.p.m., Design LRZ - Single operation 5
Performance 2900 r.p.m., Design LRZ - Parallel operation 6
Performance 1450 r.p.m., Design LRZ - Single operation 7
Performance 1450 r.p.m., Design LRZ - Parallel operation 8
Performance 1450 r.p.m., Design LMZ Single operation Parallel operation 9
Design LR Design LMR Design features LR, LMR: Single stage volute casing pump in Inline design with direct mounted standard IEC Norm Motor. Meet the requirements according to ISO 9908 High efficiency enclosed impeller. Sizes 40-125 up to 80-160 standard made of stainless steel 1.4404, stamped and laser welded. Sizes 80-200 up to 150-250 standard cast iron, optional bronze. Casing in solid design. Suction and discharge Inline. Flanges DN 40 up to DN 150 standard PN 16. Seal chamber dimensioned according to EN 3096 Large open conical seal chamber, selfventing with internal circulation for proper lubrication and cooling of the seal. Ribs in the seal chamber prevent the accumulation of air or gas in the area of the seal faces and reduce wear caused by solids in the fluid. Shaft sealing by means of single, unbalanced mechanical seal according to EN 12756, design U, version k (former DIN 24 960, l1k). Standard mechanical seal materials: Carbon Silicon Carbide (SiC) EPDM (BQ1EGG), optional elastomers in FPM (Viton ) (BQ1VGG). As option also available in SiC SiC FPM (Viton ) (Q1Q1VGG). Solid motor adapter made of cast iron to connect directly standard IEC Norm Motors, design B5/V1. Pump shaft designed as stub shaft and completely made of stainless steel for a long lifetime, directly connected to the motor shaft. 10
With stub shaft and standardized motor Close-coupled with special motor shaft extension Design LRZ Design LMZ Design features LRZ / LMZ: Single stage volute casing pump in Inline design with direct mounted standard IEC Motor. Operation and stand-by pump in a common casing with integrated automatic reversing flap. Drive unit (Impeller and motor) are identical and also identical with the single Inline pump LMR. Other features identical with Series LMR. 11
VOGEL Inline Pumps, Design LER / LEZ - Extension Program Performance: Capacity up to 1000 m 3 /h (4400 USgpm) Head up to 80 m (262 feet) Speed up to 2950 min -1 (2950 rpm) Pump Sizes: DN 100 up to DN 300 (4 up to 12 ) discharge Temperature of pumped liquid: Max. 150 C (302 F) Casing pressure: Design LER Design LER/LEZ: 10 bar/120 C Design LERS: 16 bar/150 C Liquids: Clean and slightly contaminated fluids (without bigger solids) Cold and hot water Condensate Water-Glycol mixtures, etc. Applications: Design LEZ Water supply and water treatment Cooling and hot water supply in industries and building services engineering Filter systems, etc. Materials: Design Size Code Impeller Casing, Seal chamber Wear rings Motor adapter Shaft LER LERS DN 100 up to DN 250 DN 300 NN 0.6020 0.6020 NL 0.6020 0.7040 LN 0.7040 0.6020 LL 0.7040 without 0.6020 1.4460 LEZ DN 125 up to DN 250 NN 0.6020 0.6020 NL 0.7040 12
VOGEL Inline Pumps, Design LER / LEZ - Extension Program Design LER Design LEZ Design Features LER / LEZ: Single stage volute casing pump in Inline design with direct mounted Motor with one motor and pump shaft. Design LER Single Inline Pump Design LERZ Twin-Inline Pump. Operation and stand-by pump in one common casing with integrated automatic reversing flap. Meet the requirements according to ISO 9908 High efficiency enclosed impeller. Standard made of cast iron, optional bronze. Casing in solid design. Suction and discharge Inline. Flanges PN 10, optional for Design LERS, PN 16. 13
VOGEL Inline Pumps - HYDROVAR Sensorless HYDROVAR - Application examples The sensorless control system is a new way to control the pump speed! The HYDROVAR-Sensorless System works without any external Sensors (pressure capacity)! The controller works based on the measured power consumption curve over the capacity. Power 1.1. up to 11 kw. 14
, LER & LEZ Program Extension Volute Casing Pumps LN / L: Single Stage Volute Casing pump according to EN 733 / ISO 9908 Sizes from DN 32 up to DN 150 (1 1/4 up to 6 ) Capacities up to 600 m 3 /h (2640 USgpm) Heads up to 100 m (328 feet) Design L Blockpumps LMN / LM: Horizontal single stage block pump with direct mounted IEC-Norm Motor Sizes from DN 32 up to DN 150 (1 1/4 up to 6 ) Capacities up to 500 m 3 /h (660 USgpm) Heads up to 95 m (312 feet) Design LM Motor Sizes up to 55 kw (75 hp) Volute Casing Pumps LS: Extension of the performance range of model LN/L Horizontal Design according to ISO 5199 Sizes from DN 125 up to DN 600 (5 up to 24 ) Capacities up to 4600 m 3 /h (20250 USgpm) Design LS Heads up to 100 m (328 feet) 15
ITT Austria GmbH A-2000 Stockerau Ernst Vogel-Straße 2 Telefon:..43-2266-604 Telefax:..43-2266-65311 E-Mail: info.ittaustria@itt.com www.ittaustria.com Hinweis gemäß Produkthaftungsgesetz: Die angeführten Einsatzmöglichkeiten sind nur als eine Produktübersicht aufzufassen. Die genauen Einsatzgrenzen sind dem Angebot, der Auftragsbestätigung und der Betriebsanleitung zu entnehmen. Liste 1160.1.B 10/2005-e 16