The safest, lightest, most versatile initial attack monitor ever!

Similar documents
Color-Coded Polymer Pistol Grip, Valve Handle Covers offer rugged durability in harsh fi refi ghting conditions

Innovative Firefighting Products

8296 Portable Monitor Operating & Maintenance Instructions

AKRON BRASS COMPANY PH ( ) FAX ( )

Innovative Firefighting Products

Integrated Stream Shaper Reflective band. Safety strap and hook. Compact folding legs

NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES

NOZZLES NOZZLES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE TURBOJET NOZZLES NEW LOW PRICE

NOZZLES NOZZLES SPECIALTY SABERJET NOZZLES THE FIRST TRULY MULTI-PURPOSE NOZZLE

UltraJet Nozzle. AKRON BRASS COMPANY PH ( ) akronbrass.com

Compact Wildland Attack

NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES

PA1 - Piercing Nozzle System

MANUAL: Twister and BubbleCup Nozzles

Darley Fire Storm Nozzle

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products

Head to Head Demo Comparison Sheet

TurboJet Nozzles. SaberJet Nozzles NOZZLES. The First Truly Multi-Purpose Nozzle. SaberJet Single Shutoff Nozzle. SaberJet Dual Shutoff Nozzle

ICE-CONTROL EQUIPMENT For Ground Anti-icing & Deicing Fluid Application

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised

THE REVOLUTIONARY STINGER

TASK FORCE TIPS. *** Automatic Nozzle ***

TFT HAND HELD AUTOMATIC PRESSURE CONTROL NOZZLES

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

In U.S./International Akron Brass Company P.O. Box 86 Wooster, OH PH: Fax:

MANUAL: Foam Attachments for TFT Nozzles

MANUAL: Foam Attachments for TFT Nozzles

Head to Head Demo Comparison Sheet

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Elevating Platform Revised

Industrial Electric Monitors. Industrial

SCAN IT, WATCH IT! Smartphone video link. Multiple Flow Settings. High Visibility Reflective Operating Labels. With or Without Pistol Grip

590G Series Golf Spray Head. 590G Series Golf Spray Head. Variable Arc 4, 6, 12 Pop-up X-Flow and Check-O-Matic Standard.

1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.

Essentials of Fire Fighting

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE

Maximum Flow: 600 GPM (3800 LPM) Portable Base 1250 GPM (4800 LPM) Direct Mount. Maximum Pressure: 200 PSI (1380 Kpa, 13.8 BARS)

MANUAL: ThunderFog, QuadraFog and QuadraCup

STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

MANUAL: Metro 1&2 Fixed Gallonage Nozzle

570Z Series. Reliability is simply stated in. 570Z Series 20 years of solid. performance. Add to that its. extensive product line offering and

MANUAL: PRO/pak Portable Multi-Purpose Foam System

ULTIMATIC, MID-MATIC & HANDLINE

FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE

MANUAL: FLIP TIP TM NOZZLE INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE

MANUAL: Foam Nozzles and Foam Attachments for TFT Nozzles

STYLE 3463 FireFox. With Position Feedback Potentiometer

FOAM GUN PROPORTIONER THE FOAM GUN PROPORTIONER FOAM CARTRIDGES

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

Lightweight Aluminum Alloy Adapters

DANGER MANUAL: 2 1/2 FLIP TIP2 TM NOZZLE WARNING NOTICE. TASK FORCE TIPS, INC. MADE IN USA

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Superior Performance

ULTIMATIC, MID-MATIC & HANDLINE

PRODUCT LINEUP CHIEF XD NOZZLES XD SHUTOFFS XD SMOOTH BORES. your safety. our mission. June 2017

MANUAL: MASTER FOAM FIXED GPM SELF-EDUCTING FOAM NOZZLE

HEMISPHERE Transportable Monitor Manual

FIRE HOSE. NOTE: All Hose Normally Supplied With Couplings Attached.

Colorado Division of Fire Prevention & Control Driver Operator Aerial JPRs (NFPA 1002, 2014 Edition)

MONITORS DESCRIPTION. Grease fitting for lubrication

M ANUFACTURER S M ANUFACTURER, INC.

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

MANUAL: EF1 RC MONITOR

MANUAL: Foam Aspirators

DANGER VALVE INTEGRAL TIP (VIT) NOZZLE MANUAL WARNING WARNING WARNING. TASK FORCE TIPS, INC. MADE IN USA

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

MANUAL: Metro 0, 1 & 2 Fixed Gallonage Nozzles

Standard Monitor Range

5000 Series Rotors 5000, Plus, PRS, SAM

SHOWER NOZZLES TABLE OF CONTENTS. ShowerJet One-piece, High-pressure. ShowerJet Disc-type. Lock Rings. NeedleJet Nozzles.

MANUAL: MASTER FOAM FIXED GPM SELF-EDUCTING FOAM NOZZLE

QUALITY VALVES AND CONTROLS

2017 FULL LINE PRODUCT CATALOG

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

MANUAL: TRANSFORMER INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

ZAMAC FITTINGS. Zamac Pipe Fittings. Toll Free (800) Fax (866) :00 am to 4:30pm PST

MANUAL: MONSOON & MONSOON RC MONITOR

Our Smallest Members of the Tube Cleaning Family. The BN18 is for tubes from 7/8" - 1-1/4" I.D.

VORTEX TM INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE

and stream Automatic flow Page 1-8 Wide selection of flow and pressure Simple to use and train with Fixed flow Page 1-4 Page 1-17 Page 1-3 and stream

24-Hour Turnaround Factory Service 24-Hour Technical Hot-line: ORDERING INFORMATION THREAD ORDERING INFORMATION

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE. Dual Handwheel 3.5 Discharge. Dual Handwheel 2.5 Discharge

Hose & Apparatus Test Equipment

MANUAL: ThunderFog, QuadraFog and QuadraCup

STYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS

PLEASURE BOAT EQUIPMENT

MANUAL: MONSOON & MONSOON RC MONITOR

MANUAL: Metro 1 & 2 Fixed Gallonage Nozzles

Section J Air Control Nozzles

ESCONDIDO FIRE DEPT TRAINING MANUAL Section ENGINE MODULE Page 1 of 12 Special Operations Revised

Standard Monitor Range

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

MANUFACTURER S MANUFACTURER, INC.

08 general Purpose Pumps

FOAM AQUEOUS FILM FORMING FOAM (AFFF) ALCOHOL RESISTANT AQUEOUS FILM FORMING FOAM (AR-AFFF) NEW FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS

Made in U.S.A. Model 105C. Part Product " spinner Spinner

MANUAL: Metro 0, 1 & 2 Fixed Gallonage Nozzles

MANUAL: HURRICANE & HURRICANE RC MONITOR

Transcription:

The safest, lightest, most versatile initial attack monitor ever!

With SafeTak II Automatic Shut-Off Valve Rated Flow 500 GPM Nominal Size 2.5" Nominal Area 4.9 sq. in. Weight 22 lbs. Folded Size 25.5" x 8" x 10" XXC-32 PACKAGE CONTAINS: BLITZFIRE MONITOR STORAGE BRACKET MAX-SERIES tip XXC-42 PACKAGE CONTAINS: BLITZFIRE MONITOR STORAGE BRACKET 3 STACKED TIPS STREAM STRAIGHTNER 1. MD12A Automatic Nozzle 2. XF-SS5 Stream Straightener 3. MST-3NJ 3 Stacked Tip 4. XX-B Storage Bracket XXC-52 PACKAGE CONTAINS: BLITZFIRE MONITOR STORAGE BRACKET MAX-SERIES tip 3 STACKED TIPS STREAM STRAIGHTNER Pre-Connect For Maximum Flow With Limited Resources. Task Force Tips, Inc. 2800 E. Evans Avenue Valparaiso, IN 46383-6940 800-348-2686 219-462-6161 Fax 219-464-7155 www.tft.com LIX-610 October 17, 2001 REV 2

Dual Pressure Automatic nozzle with a flow capacity of 100-500 GPM. Switch between standard 100 PSI and a low pressure mode by twisting a knob on the front of the nozzle. The built-in halo ring adjusts the pattern from straight stream to a 120 degree wide fog and flushes 3/8" debris without shutting down. Hard anodized aluminum with rubber bumper. Standard inlet is 2.5"NH. 100 PSI Automatic pressure control with a flow capacity of 100-500 GPM. The built-in halo ring adjusts the pattern from straight stream to a 120 degree wide fog and flushes 3/8" debris without shutting down. Hard anodized aluminum with rubber bumper. Standard inlet is 2.5" NH. 80 PSI Automatic pressure control nozzle has the same features as above but operates at a low pressure of 80 PSI. MAX-FLOW 500 GPM @ 100 PSI Fixed Gallonage. The fixed orifice tip is ideal for high rise attack and will operate with pressures as low as 30 PSI. The built-in halo ring adjusts the pattern from straight stream to a 120 degree wide fog and flushes 3/8 debris without shutting down. Hard anodized aluminum with rubber bumper. Standard inlet is 2.5 NH. PRESSURE PSI 120 100 80 60 40 20 0 0 400 800 1200 1600 2000 FLOW (LPM) 0 0 100 200 300 400 500 600 FLOW (GPM) 100 PSI (7 BAR) MAX-FORCE / MAX-MATIC 500 GPM (1900LPM) MAX-FLOW 80 PSI (5.5 BAR) MAX-MATIC 55 PSI (4 BAR) MAX-FORCE 8 7 6 5 4 3 2 1 PRESSURE BAR

INITIAL With the stream directed this involved structure provided maximum flow The BLITZFIRE from Task Force Tips, Inc. is the most advanced initial attack portable monitor ever designed for high performance fire suppression. Realizing that the ability to maximize flows while dealing with limited manning is a reality in today's fire service, TFT has developed the lightest, easiest to operate, and by far the safest portable ground monitor in the world. Combining TFT's exclusive slide valve, the unique Safe-Tak II safety shutoff, and the new Max- Force dual pressure nozzle, the Blitzfire will set the standard for rugged, high-flow, initial fire attack. pivoting inlet Pivoting up and down 20 degrees, the inlet allows the monitor to be stable while positioned on porches, stair landings, and below grade. HIGH-RISE OPERATIONS The Blitzfire easily fits into high-rise hose bundles for rapid deployment from standpipe systems. folding legs Legs that uniquely fold for storage and unfold easily for operation. Maximum strength with minimum weight. INTERIOR ATTACKS When combined with TFT's unique slide valve, the Blitzfire's low attack angle provides Total Nozzleman Flow Control. Carbide Tipped Spikes Carbide tips wear longer than typical steel only spikes and are easily replaceable. TF-COAT Finish The entire waterway is p to provide maximum minimal friction loss. LOW ATTACK ANGLE The Max-Matic 500 gpm dual pressure nozzle provides maximum reach and penetration, or maximum flow in low pressure situations.

The Safe-Tak II flow control and safety shut-off valve combine TFT's exclusive turbulence free, six-detent stainless steel slide valve with a uniquely integrated safety shutoff mechanism for total firefighter flow control. The valve can be opened to any of the six flow positions allowing the operator to regulate the flow depending on need. Once set, the valve can continue to be manually regulated or used in an unattended manner. If the monitor starts to move or becomes unstable, the Safe-Tak II will shut off the monitor's flow, thus eliminating the reaction force. By design the valve has a slow close feature that minimizes the effect of water hammer. Used in combination with either the Dual-Pressure 500 gpm Max-Force Automatic nozzle, or our specially designed triple stack smooth bore tips, the Blitzfire can provide maximum flow under all flow and pressure conditions. sh is powder coated um flow with. Patents Pending pivoting outlet The pivoting outlet of the Blitzfire allows 20 degrees of motion either side of center and 40 degrees of motion from 10 degrees above horizontal to 50 degrees. TIAL ATTACK ected right into the front door of ture fire, the Blitzfire safely flow within moments of arrival. LIGHTWEIGHT & PORTABLE Designed to provide maximum flow with limited resources, the Blitzfire is easily advanced by a single firefighter. In addition to all of these exceptional features, the Blitzfire is covered by the TFT exclusive 5-year warranty and our industry leading 24-hour service policy. Service and maintenance information are available from customer service 24/7/365 and from TFT's award winning web site. www.tft.com

Patents Pending Pending Task Force Force Tips, Inc. 2800 2800 East Evans Avenue Valparaiso, IN 46383-6940 www.tft.com www.tft.com Valparaiso, IN 46383-6940 800.348.2686 219.462.6161 XL670 blitzfire Personal Portable Portable Monitor Monitor DANGER DANGER LOCKED CLOSED CLOSED OPEN OPEN PULL PULL TO TO UNLOCK UNLOCK HANDLE HANDLE The Blitzfire has been designed to operate at very low elevation angles to maximize usefulness for interior attack. As with any monitor, when the elevation angle is low the risk of sliding is increased. This is because at low elevation angles the reaction force is more horizontal and less vertical. OUTLET PIVOTS INLET PIVOTS 50 800.348.2686 219.462.6161 XL670 Read instruction manual before use. Operation of this device without understanding the manual and receiving proper training is dangerous and is a misuse of this equipment. Risk of sliding increases at low elevation angles. To reduce risk of injury or death from sliding, test safety shut-off valve before using. 40 40 10 SIDE VIEW TOP VIEW The Blitzfire's outlet pivots allow for 40 degrees of sideways motion and elevation between 10 and 50 degrees. Push or pull on the nozzle to redirect the stream. The pivots are easy to reposition under pressure and are good for rapid redirecting of the stream. However, if the pivot is rapidly bumped against its travel limit, the Safety Shut-Off Valve may activate and shut off the monitor. The Blitzfire OSC oscillating monitor has all the versatile features and safe operation of the Blitzfire, and an added function that allows the nozzle to move left and right automatically. A small paddlewheel in the unit provides the power to direct the stream back and forth, without unwanted water discharge on the ground. User adjustable for 20, 30, or 40 nozzle sweep for narrow to wide coverage area. Oscillation is easily overridden with the push of a button to allow manual control and re-engagement of the automatic motion is quick and simple. An excellent choice for cooling or extinguishing a large area, for haz-mat vapor mitigation, or remote unmanned operations. ELEVATION CONTROL - Lifting the nozzle changes the elevation from 10 to 50 instantly.