Series SYJ300/500/700

Similar documents
3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Series SYJ3000/5000/7000

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

3 Port Solenoid Valve

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Solenoid Valve

Series SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Series VQ Port Solenoid Valve

Rubber Seal VP300/500/700

Example. U side. Stations SY5000

Pilot Operated 2 Port Solenoid Valve for Dry Air

3 Port Solenoid Valve

Series VQZ1000/2000/3000 Single Unit

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Series SV1000/2000/3000/4000

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

5 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

3 Port Solenoid Valve Direct Operated Poppet Type

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

VQ1000. How to Order Manifold. Kit type

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

Series VP3145/3165/3185

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve for Dry Air

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port 3 Position Valve

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

4 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

4 Port Solenoid Valve

5 Port Solenoid Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Manifold Specifications

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5 Port Solenoid Valve

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

5 Port Solenoid Valve

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Series SY3000/5000 How to Order Manifold

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

5 Port Pilot Solenoid Valve Rubber Seal

Series SY3000/5000/7000

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

Compact Vacuum Ejector

Space Saving Vacuum Ejector/Vacuum Pump System

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

5 Port Air Operated Valve

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Series VP3145/3165/3185

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Coolant Valve. Air Operated/External Pilot Solenoid

5 Port Solenoid Valve Plug Lead Type

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

0.35 W (Without light)

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

Series SY3000/5000/7000

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Vacuum Equipment. Application. Series

Transcription:

ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00. Mounts on the same subplates and manifolds as the VJ00/00/00 and the VZ00/00. SYJ00 SYJ00 SYJ00 Series VJ VJ00 VJ00 VJ00 Series VZ VZ00 VZ00 SY SYJ VK VZ V VG VQ VQZ Standard valve suitable for copper free applications Valve can be piped for selector or divider applications. Bright colour tone and Universal porting is possible. state of the art design pplication Example qblow off valve (SYJ ) port wvalve for vacuum eoperation of a single control acting cylinder (SYJ ) (SYJ /SYJ ) port rdivider valve (SYJ ) port tselector valve (SYJ ) Vacuum applicable Up to -0ka port yressure release Valve (SYJ ) port () ()1 () () ()1 () () ()1 () Tank Tank () ()1 () 0.Ma () ()1 0.Ma () () ()1 lug ().-1

ort Solenoid Valve ubber Seal Series SYJ00/00/00 Variations Series SYJ00 ort size Effective area (mm ) (Nl/min) ctuation Voltage Electrical entry Option Indicator light and surge voltage suppressor Manual override M 0. 0.9 (.08) Grommet Body ported SYJ00 M 0.8. (19.) L plug connector SYJ00 SYJ00 M 0.8 9.0 (0.) 1.8 (98.1) N.C. N.O. DC 4V DC 1V DC V DC V DC V DC M plug connector DC With surge voltage suppressor With indicator light and surge voltage suppressor Non-locking push style ush-locking slotted style Base mounted SYJ00 4. (4.8) SYJ00 1 8 / 1 4 9.0 (0.).-

Series SYJ00/00/00 Manifold Variations port size Valve series ort location / port size M M With built-in One-touch fitting pplicable tube O.D. ø4 ø ø8 Body ported Base mounted SYJ00 SYJ00 SYJ00 SYJ00 SYJ00 SYJ00 Top Top Top Side Bottom Side Bottom Side M 0.8 1/4 M 0.8 1/4 1/4 (1) () (1) (1) (1) SY SYJ VK VZ V VG Note 1) Only internal pilot style Note ) Only external pilot style VQ VQZ Series SYJ00 Series SYJ00 Series SYJ00.-

Series SYJ00/00/00 Warning Operation of Manual Override Use caution since manual override operation will operate any connected actuators. Non-locking push style [Standard] ress in the direction of the arrow. ush-locking slotted style [D] While pressing, turn in the direction of the arrow. If you do not turn, the mechanism does not lock in position. Locked position Note) second manual override is located on the pilot valve assembly. It is only available as a non-locking push style. Simply depress in the direction of the arrow shown to operate. Caution Common Exhaust ort for The ilot and Main Valve ilot air is exhausted through the main valve body rather than directly to atmosphere. Suitable for applications where exhausting the pilot valve to atmosphere would be detrimental to the surrounding working environment. For use in extremely dirty environments where there is the possibility that dust could enter the pilot exhaust and damage the valve. Ensure that the piping of exhaust air is not too restrictive. Caution Bracket When with bracket of SYJ00, do not use it without a bracket. Caution How to Use lug Connector qconnection/disconnection of connector Connectionush the connector straight on to the pins of the solenoid, making sure the lip of the lever securely "locks" into the groove of the solenoid cover. Disconnectionress the lever against the connector housing and pull it outward from the solenoid USH LOCK recautions Be sure to read before handling. efer to p.0- to 0- for Safety Instructions and common precautions on the products mentioned in this catalog. wcrimping connection of lead wire and socket Strip. to.mm of the lead wire ends, insert each stripped wire into a socket and crimp it using special crimping tool. Be careful that the outer insulation of the lead wires does not interfere with the socket contact part. (Contact SMC for the special crimping tool.) Core wire contact area Socket Hook econnection/disconnection of socket with lead wire Connection Insert lead wire and crimped socket into square holes (indicated as positive or negative) of connector. ress the socket in fully until the hook of the socket locks into the groove of the connector housing. Confirm the locked position by lightly pulling on the lead wire. Disconnection To remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screw driver (or similar). If the socket is to be re-used, reposition the hook again. Socket lug Connector Lead Wire Length Standard length is 00mm, but the following lengths are also available. How to Order Connector ssembly For DC: Hook Caution Cover Groove in Crimping area Core wire Cover Groove in Connector housing Hook Lead wire Insulation SY0 0 4 Without lead wire (with connector and : sockets.) How to Order To order a valve with lead wire length of other than 00mm, indicate part numbers. of the valve without connector and the required connector assembly separately. (Example) 00mm lead wire length For DC SYJ1-LO-M SY0-0-4- Lever DC indicator Socket DT10-1-1 Lead wire 0. to 0.mm Max. cover diameter: ø1.mm Connector housing Lead wire SY0 0 Lead wire length (mm) 1 0 0 00 00 00 0 00 0 000 000.-4

Series SYJ00/00/00 Caution Surge Voltage Suppressor <For DC> Grommet, L and M plug connector Standard style (With polarity) With surge voltage suppressor ( S) ed (+) Black () ed (+) Black () Non-polar style With surge voltage suppressor ( ) ed (+) Black () Diode Diode to prevent reverse connection With light and surge voltage suppressor ( Z) Diode to prevent reverse connection LED Zener diode Coil Coil Coil Connector ssembly with rotective Cover Connector assembly with protective cover enhances dust protection. Effective in preventing possible short circuit problems due to contaminants in contact with connector section. Cover material is chloroprene rubber which has excellent weatherability and electric insulation properties. However, be careful not to allow contact with cutting oil. ound cord provides neat appearance. How to Order SY0 8 Lead wire length (L, mm) 1 0 0 00 00 00 0 00 0 000 000 Connector ssembly with Cover/Dimensions (40) Gray SY SYJ VK VZ V VG With light and surge voltage suppressor ( U) (+) () (.9) () ed Black (ø4.1) (8) VQ Zener diode Coil (8) VQZ (+) () lease correctly connect the lead wires to + (positive) and _ (negative) indications on the connector. For non-polar style, the lead wires can be connected to either one. For DC voltages other than 1, 4 incorrect wiring will cause damage to the surge voltage suppressor circuit. (Wrong polarity will cause trouble.) Solenoids, whose lead wires have been pre-wired, are positive side red and negative side black. (.) L How to Order Connector ssembly with rotective Cover Specify the part numbers of the solenoid valve without connector and the connector assembly with protective cover separately. E. 1) In case of 00mm of lead wire SYJ1-LOZ-M-Q SY0-8-- E. ) In case of 00mm of lead wire (Standard) SYJ1-LZ-M-Q Symbol of connector assembly with protective cover.-

ort ilot Solenoid Valve ubber Seal Series SYJ00 Model Body ported Valve model Base mounted (With sub-plate) Note 1) t DC. SYJ1 SYJ SYJ SYJ4 ctuation N.C. N.O. N.C. N.O. ort size M 0. M 0.8 Effective area (mm )(Nl/min) 0.9 (.08) 1.8 (98.1) Grommet 9 0 (Without sub-plate 9) Weight (g) (1) L plug connector, M plug connector. 1 (Without sub-plate 1) JIS Symbol Internal pilot SYJ1 4 SYJ 4 () 1 ()() External pilot SYJ1 4 SYJ 4 () Body ported Base mounted () 1 () () () Specifications Fluid Operating pressure range (Ma) Internal pilot mbient and fluid temperature ( o C) esponse time (ms) (at 0.Ma) (1) Max. operating frequency (Hz) ilot exhaust Lubrication Mounting position Impact/Vibration resistance (m/s ) () rotection structure ir 0.1 to 0. Max. 0 1 or less Non-locking push style, ush-locking slotted style Individual pilot exhaust, Common exhaust (pilot and main valve) Not required Free /0 Dust proof Note 1) ccording to dynamic performance test JIS B84-1981 (Coil temperature o C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage) Vibration resistance: No malfunction occurred in a one-sweep test between 8. and 00Hz. Test was performed at both energized and de-energized states to axis and right angle directions of the main valve and armature. (Value in the initial stage) Solenoid Specifications Electrical entry Coil rated voltage (V) llowable voltage ower consumption (W) (1) Surge voltage suppressor Indicator light (1) t rated voltage DC DC Grommet (G) (H), L plug connector (L), M plug connector (M) 4, 1,,, + % rated voltage 0. (With light: 0.) Diode LED 1 ()() 1 () () Order Made..-4.-

Series SYJ00 External ilot SYJ00 ilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port. This model is suitable for low pressure (less than 0.1Ma) and vacuum (up to 0ka) applications. Specifications pplicable model Operating pressure range (Ma) / port M 0.8 port (External pilot) M 0.8 Base mounted (SYJ, SYJ4) Main pressure 0ka to 0. External pilot pressure 0.1 to 0. port M 0.8 SY SYJ VK VZ V VG Note 1) efer to p..- for manifold. Note ) External pilot style body ported valves (SYJ ) can only be used on the manifold. VQ VQZ.-

Series SYJ00 How to Order port ated voltage V S 9 Order Made 4V DC 1V DC V DC V DC V DC 0V or less Contact SMC for other voltages (9) Indicator light and surge voltage suppressor S Z U Without indicator light and surge voltage suppressor With surge voltage suppressor With indicator light and surge voltage suppressor With indicator light and surge voltage suppressor (Non-polar) Bracket : Without bracket F: With bracket (For manifold type, ) ctuation 1 Normally closed Normally open bracket Bracket is supplied not mounted. Except extemal pilot style Body ported SYJ 1 M M -Q Base mounted SYJ 1 4 M -Q port Body option : Individual exhaust for the pilot valve : Non-locking push style ort size : Without sub-plate M: With M port sub-plate For sub-plate style, manifold type 41, S41, 4, S4, 4, S4 port /E port M: Common exhaust for the pilot and main valve D: ush locking slotted style (With gasket and screws) port /E port ilot valve exhaust is centralized to main valve. : External pilot style SYJ is only for manifold use. Electrical entry 4V, 1V, V, V, V DC Grommet L plug connector M plug connector G: 00mm lead wire L: 00mm lead wire M: 00mm lead wire MN: Without lead wire H: 00mm lead wire LN: Without lead wire LO: Without connector MO: Without connector.-8 rotective class class III (Mark: ) LN and MN types are with sockets.

Series SYJ00 Construction N.C. () 1 ()() N.O. () 1 () () e q t r e q t r SY SYJ VK u u VZ w w V y y VG Component arts No.! " # Description Body iston plate End cover iston Spool valve ass'y Material Zinc die cast esin esin esin luminum/nb Note White White White eplacement arts No. $ % Description Sub-plate ilot valve arts No. SYJ00-9-1-Q SY1- -Q Note Zinc die cast VQ VQZ How to Order ilot Valve ssembly How to Order Connector ssembly SY1 V S ated voltage 4V DC 1V DC V DC V DC V DC G Indicator light and surge voltage suppressor S Z U -Q Without indicator light and surge voltage suppressor With surge voltage suppressor With indicator light and surge voltage suppressor With indicator light and surge voltage suppressor (Non-polar) DC : SY0-0-4- Without lead wire (with connector and sockets) : SY0-0- Lead wire length (mm) 1 0 0 00 00 00 0 00 0 000 000 G H L LN LO M MN MO Manual Grommet (Lead wire: 00mm) Grommet (Lead wire: 00mm) L plug connector M plug connector With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector.-9

Series SYJ00 Body orted Grommet (G), (H): SYJ - G H -M-Q With bracket: SYJ - G H -M-F-Q 9. -M 0. (iping port) 8 1. 9 8. 1 1. 4.8 (GZ, GS: 48.8) 48. (GZ, GS:.) 8. 44 G: H: 00 Depress and turn to operate and lock override. -ø. 1 Bracket 8.4. 1.4 0. (GZ, GS: 1.).4.1 -ø1.8 (Mounting holes for manifold) 4.8 1. L plug connector (L): SYJ - L -M-Q M plug connector (M): SYJ - M -M-Q 8 1. 9 1. 8. 9.1 8 9 1. 48.9 1. 8 1. 8 44.9 8. 8..4.1 -ø1.8 (Mounting holes for manifold).4.1 -ø1.8 (Mounting holes for manifold).-

Series SYJ00 Base Mounted (With sub-plate) Grommet (G), (H): SYJ 4- G H -M-Q (M 0.8) (External pilot port) 8... 9.1 41. SY. Depress and turn to operate and lock override. -M 0.8 (iping port) -ø. 8. 8 1. 1. SYJ VK VZ G: H: 00 4.8 (GZ, GS: 48.8) 48. (GZ, GS:.) V VG VQ VQZ L plug connector (L): SYJ 4- L -M-Q M plug connector (M): SYJ 4- M -M-Q -M 0.8 (iping port) 8. 8... 9.1 41. 8... 41.. -ø. 8 1. 1. -M 0.8 (iping port) -ø. 8. 8 1. 8. 1. 44.9 48.9.-

Series SYJ00 Manifold Manifold Specifications For internal pilot Type For external pilot Manifold style (SU)/(EH) style Valve stations port Location specifications Direction / port ort size port Valve Top M 0.8 M 0. 41, S41 4, S4 4, S4 Single base style/b mount Common SU/Common EH to stations Base Side M 0.8 M 0. 1 /8 M 0.8 C4 (ø4 One-touch fitting) port (1) M 0.8 M 0.8 Valve effective area (mm ) (Nl/min) () Body ported SYJ /SYJ Base mounted SYJ 4/SYJ 4 0.9 (.08) 1.(8.) Note 1) Only for external pilot Note ) Value when used on a manifold How to Order Manifold ssembly Specify the part numbers for the valve(s), blank plate assembly, and manifold base. Example: SSYJ--0-Q... 1 pc. (Manifold base) SYJ1-LZ-M-Q... pcs. (Valve) SYJ00--1-Q... 1 pc. (Blank plate ass'y) SSYJ-4-0-C4-Q... 1 pc. (Manifold base) SYJ-G-Q... pcs. (Valve) SYJ00---Q... 1 pc. (Blank plate ass'y) Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blank late ssembly Body ported (SYJ ) Base mounted (SYJ 4) SYJ00--1-Q SYJ00---Q hillips head screw SY0-- M1. 1, Matt nickel plated Blank plate SYJ00--1 hillips head screw SY0-- M1. 1, Matt nickel plated Blank plate SYJ00--1 Manifold gasket SYJ00-- Manifold gasket SYJ00--4 Manifold gasket SYJ00-- Manifold gasket SYJ00--4 pplicable base SSYJ- SSYJ- Manifold base pplicable base Sub-plate SSYJ-41 SSYJ-S41 SSYJ-4 SSYJ-S4 SSYJ-4 SSYJ-S4 Manifold base pplicable base SSYJ- SSYJ- Manifold base pplicable base Sub-plate SSYJ-41 SSYJ-S41 SSYJ-4 SSYJ-S4 SSYJ-4 SSYJ-S4 Manifold base.-1

Series SYJ00 Manifolds for Internal ilot Type 41 Type port M 0. 41 Type 4 Type 4 Type port M 0.8, C4 ort M 0. port M 0.8 port M 0.8 port port port M 0.8, C4 port M 0. ort M 0.8 ort M 0.8 S41 Type Coil is located on same side as the port. S4 Type Coil is located on same side as the port. Manifolds for External ilot port M 0.8 port M 0.8 port port How to Order SSYJ---- 0 -- -Q stations Note) If more than stations, supply air to both sides of port and exhaust air from both sides of port. How to Order SSYJ-- Valve mounting direction S Coil is located on the opposite side of the port. Coil is located on same side as the port. Bracket Without bracket F With bracket 41-- 0 --M-Q Note) If more than stations, supply air to both sides of port and exhaust air from both sides of port. How to Order SSYJ-- 4-- 0 -- M - -Q Valve mounting direction Coil is located on the opposite side of the port. Coil is located on S same side as the port. M C4 port side M 0.8 ø4 One-touch fitting Stations 0 stations pplicable solenoid valve SYJ1- -M-Q SYJ1M- -M-Q SYJ- -M-Q SYJM- -M-Q pplicable blank plate ass'y SYJ00--1-Q pplicable solenoid valve SYJ- -Q SYJM- -Q SYJ4- -Q SYJ4M- -Q pplicable blank plate ass'y SYJ00---Q pplicable solenoid valve SYJ- -Q SYJM- -Q SYJ4- -Q SYJ4M- -Q pplicable blank plate ass'y SYJ00---Q Note) If more than 8 stations, supply air to both sides of "" ort and exhaust air from both sides of "" port. ilot valve pressure is isolated from main valve pressure through a separate supply line. This is suitable for vacuum (up to -0ka) and low pressure 0.1Ma applications. 0... Stations stations 0...... Stations stations... stations...... stations, port Thread c (T) F G (F) N NT T NTF SY SYJ VK VZ V VG VQ VQZ Type 4 Type ort M 0.8, C4 port M 0. ort (External pilot) M 0.8 4 Type (External pilot) ort (External pilot) M 0.8 rotective class class III (Mark: ) port port port M 0.8, C4 port port S4 Type Coil is located on same side as the port. S How to Order SSYJ---- 0 -Q pplicable solenoid valve SYJ1- -Q SYJ- -Q pplicable blank plate ass'y SYJ00- -1-Q Note) If more than stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port. How to Order SSYJ-- 4-- 0 -- M - -Q Valve mounting direction 0... Coil is located on the opposite side of the port. Coil is located on same side as the port. Stations stations... stations 0... Stations stations..., portthread c (T) 00F G (F) 00N NT 00T NTF pplicable solenoid valve SYJ- -Q SYJ4- -Q pplicable blank plate ass'y SYJ00---Q, portthread c (T) ort stations (External pilot) F G (F) M 0.8 N NT port port side T NTF M M 0.8 port C4 ø4 One-touch fitting Note) If more than 8 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port..-

Series SYJ00 Type Manifold: Top orted/ SSYJ-- Station -Q Grommet (G), (H) G: H: 00.. 4-M 0.8 (/ port) 4.9 (GZ, GS: 4.) (itch) n-m 0. =. 1. ( port). 1 -ø. L. L. 1. 1. 9.1. 41. Depress and turn to operate and lock override.. -M 0. (Bracket mounting screw) -ø. L plug connector (L) M plug connector (M).... 8. 48.9 44.9 41. 9.1 4-M 0.8 (/ port) 41.. 4-M 0.8 (/ port) Station L.-. 8. 4 9 4.. 0. 0. 88 81 8 98. 91. 9 9 9.. 0 1 0.. 4.. 1 1 1 1. 1. 1 19. 19. 19 4. 1.

Series SYJ00 41 Type Manifold: Side orted/ SSYJ-41- Station -M-Q Grommet (G), (H) n-m 0. ( port) (itch) =.. G: H: 00 9.1. 4-M 0.8 (/ port) 48.(GZ, GS:.) 8 41. SY SYJ VK Depress and turn to operate and lock override. VZ V VG 4. (itch) =. 9 -ø. L. VQ VQZ S41 Type/Side orted (Coil is located on same side as the port.) L plug connector (L) M plug connector (M) SSYJ-S41- Station -M-Q 41. 9.1. 41. 41. 9.1. n-m 0. ( port) (itch) =.. 8. 4-M 0.8 (, port) 4. 48.9 44.9 4-M 0.8 (, port) 4. 48.(GZ, GS:.) 8 L -ø. Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Other dimensions are the same as type 41. Station L. 8. 4 9 4.. 0. 0. 88 81 8 98. 91. 9 9 9.. 0 1 0.. 4.. 1 1 1 1. 1. 1 19. 19. 19 4. 1..-1

Series SYJ00 4 Type Manifold: Side orted/ssyj-4- Station -M, C4-Q Grommet (G), (H) C4 (Built-in one-touch fitting) 48. n-m 0.8 ( port) 48. (itch) =. 1. G: H: 00.4(GZ, GS: 4.1). L 4 (itch) =.. -ø4.. n-one-touch fitting ( port) pplicable tube T04 G: H: 00 (itch) =. 1. 1 (/ port) 1. 1 1.. Depress and turn to operate and lock override. 4-c(T) 8...1 9. 4-c(T) (/ port) 8. M. Other dimensions are the same as the M. L plug connector (L) M plug connector (M) (Coil is located on same S4 Type/Side orted side as the port.) SSYJ-S4- Station -M, C4-Q.1 1 9. 1 48..1 9. n-m 0.8, n-c4 ( port) (itch) =. 1. n-m 0.8 ( port).8 48. 8. 1.... 8. 1...4(GZ, GS: 4.1).. (itch). =. L. -ø4. 4 Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Other dimensions are the same as type 4. Station L.-1 41.. 44 4. 4. 8.. 94 8 8 4. 9. 9 1.. 1. 8. 1 9 1. 19. 1 10 1 8. 0. 1 199 191 9. 1. 19 1 0..

Series SYJ00 Type Manifold: Top orted (External ilot)/ssyj-- Station -Q Grommet (G), (H) 48..1 9. SY SYJ G: H: 00 40 1 8. 1.. 4- (/ port) (: External pilot style).4(gz, GS: 4.1).. 1. Depress and turn to operate and lock override. L 8 =. (itch). L -M 0.8 (External pilot port) -ø4. n-m 0. ( port) 4 VK VZ V VG VQ VQZ L plug connector (L) M plug connector (M) 1 8. 1 8..8 1.... 1...1 48. 4- (/ port) 9. 48. 4- (/ port) Station L L 4. 9. 1. 8 0 4 4 8. 0.. 9 1 89. 81.. 0 9 84 8 1.. 94. 9 1 1... 4 1 1 1. 4.. 1. 1. 1. 1 4 1 1 194... 1 19 9 1.. 199. 19. 8...-1

Series SYJ00 4 Type Manifold: Side orted (External ilot)/ssyj-4- Station -M, C4-Q Grommet (G), (H) n-m 0.8 ( port) C4 (Built-in one-touch fitting) 48. (itch) =.. G : H : 00.4(GZ, GS: 4.1). L 4 (itch) =... n-one-touch fitting ( port) pplicable tube T04 G: H: 00 48. 1 1.. Depress and turn to operate and lock override. (itch) =.. 1 4- (/ port) 8. 8 8 -M 0.8 (External pilot port) -ø4.. 1..1 9. 4- (/ port) 8. M. L plug connector (L) M plug connector (M) (Npn-locking) Other dimensions are the same as the M. (Coil is located on same S4 Type/Side orted side as the port.) SSYJ-S4- Station -M, C4-Q.8.1 48. 1 8. 1.... 9. 1 8.. 1. 48..1..4(GZ, GS: 4.1). n-m 0.8, n-c4 =.. ( port) (itch) -M 0.8 (External pilot port) 8 8. -ø4. L 4 Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Other dimensions are the same as type 4. Staition L.- 4. 9. 8 0 4 8. 0. 9 1 89. 81. 0 9 8 1.. 9 1 1.. 4 1 1. 4. 1. 1. 1 4 1 1 194.. 1 19 1.. 19. 8.

ort ilot Solenoid Valve ubber Seal Series SYJ00 JIS Symbol Internal pilot SYJ1 4 SYJ 4 () Body ported type Base mounted type () Model Valve model Body ported SYJ1 SYJ Base mounted SYJ (With sub-plate) SYJ4 Specifications ctuation N.C. N.O. N.C. N.O. ort size M 0.8 Effective area (mm ) (Nl/min). (19.) 4. (4.8) Grommet 4 (Without sub-plate 4) Weight (g) L plug connector, M plug connector. 4 9 (Without sub-plate 4) Fluid Operating pressure range (Ma) Internal pilot ir 0.1 to 0. mbient and fluid temperature ( C) esponse time (ms) (at 0.Ma) (1) Max. operating frequency (Hz) ilot exhaust Lubrication Mounting position Impact/Vibration resistance (m/s ) () rotection structure Max. 0 or less Non-locking push style, ush-locking slotted style Individual pilot exhaust, Common exhaust (pilot and main valve) Not required Free /0 Dust proof Note 1) ccording to dynamic performance test JIS B84-1981 (Coil temperature o C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage) Vibration resistance: No malfunction occurred in a one-sweep test between 8. and 00Hz. Test was performed at both energized and de-energized states to axis and right angle directions of the main valve and armature. (Value in the initial stage) Solenoid Specifications Electrical entry Grommet (G) (H), L plug connector (L), M plug connector (M) SY SYJ VK VZ V VG VQ VQZ 1 ()() External pilot SYJ1 4 SYJ 4 () 1 () () () Coil rated voltage (V) llowable voltage ower consumption (W) (1) Surge voltage suppressor Indicator light (1)t rated voltage DC DC 4, 1,,, + % rated voltage 0. (With light: 0.) Diode LED 1 ()() 1 () () Order Made..-4.-19

Series SYJ00 External ilot SYJ00 ilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port. This model is suitable for low pressure (less than 0.1Ma) and vacuum (up to 0ka { Torr}) applications. Specifications pplicable model Operating pressure range (Ma) Base mounted (SYJ, SYJ4) Main pressure --0ka to 0. External pilot pressure 0.1 to 0. port / port port (External pilot) M 0.8 Note 1) efer to p..- for manifold. Note ) External pilot style body ported valves (SYJ ) can only be used on the manifold. For body ported models with the external pilot option contact SMC..-

Series SYJ00 How to Order port (For manifold type, 1) ctuation 1 Normally closed Normally open ated voltage V S 9 Order Made 4V DC 1V DC V DC V DC V DC 0V or less Contact SMC for other voltages (9) Indicator light and surge voltage suppressor S Z U Without indicator light and surge voltage suppressor With surge voltage suppressor With indicator light and surge voltage suppressor With indicator light and surge voltage suppressor (Non polar) Bracket : Without bracket F: With bracket Bracket is supplied unmounted. Except on the extemal pilot style. SY SYJ VK VZ V Body ported SYJ 1 M M -Q VG Base mounted SYJ 1 4 M 01 -Q port For sub-plate style, manifold type 40, 40, 41, 41 Body option : Individual exhaust for the pilot valve ort /E ort : Non-locking push style ort size Thread c (T) F G (F) N NT T NTF VQ VQZ M: Common exhaust for the pilot and main valve D: ush locking slotted style : Without sub-plate 01: With ort sub-plate ort /E ort : External pilot type SYJ is only for manifold use. Electrical entry 4V, 1V, V, V, V DC Grommet L plug connector M plug connector G: 00mm lead wire L: 00mm lead wire M: 00mm lead wire (With gasket and screws) MN: Without lead wire H: 00mm lead wire LN: Without lead wire LO: Without connector MO: Without connector rotective class class III (Mark: ) LN and MN types are with sockets..-1

Series SYJ00 Construction N.C. () N.O. () 1 ()() ey q t wr 1 ()() ey q t wr i i u u Component arts No.! " # $ Description Body iston plate End cover iston Spool valve ass'y Spool spring Material luminum die cast esin luminum die cast esin Stainless Steel Note White White White eplacement arts No. % & Description Sub-plate ilot valve art No. SYJ00-9-1-Q SY1- -Q Note Zinc die cast How to Order ilot Valve ssembly How to Order Connector ssembly SY1 V S ated voltage 4V DC 1V DC V DC V DC V DC G Indicator light and surge voltage suppressor Without indicator light and surge voltage suppressor S With surge voltage suppressor With indicator light and surge Z voltage suppressor U -Q With indicator light and surge voltage suppressor(non-polar) DC Without lead wire (with connector and sockets) : SY0-0-4- : SY0-0- Lead wire length (mm) 00 00 00 1 0 00 0 0 000 0 000 G H L LN LO M MN MO Manual Grommet (Lead wire: 00mm) Grommet (Lead wire: 00mm) L plug connector M plug connector With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector.-

Series SYJ00 Body orted Grommet (G), (H): SYJ - G H -M-Q -M 0.8 (iping port) With bracket: SYJ - G H -M-F-Q. -ø. (Mounting holes for manifold).9(gz, GS: 8.) SY SYJ VK 9. 1.1. 1.. 9 8 -ø. 0. 4.8(GZ, GS:.8) -ø. 0. Bracket VZ V 1. Depress and turn to operate and lock override. VG. 9. 8. 4..(GZ, GS:.) G: H: 00 Other dimensions are the same as the grommet. VQ VQZ L plug connector (L): SYJ - L -M-Q M plug connector (M): SYJ - M -M-Q 9. 1.1. 1.. 9 8 1. -ø. 0. 40.. 1.. 9 8 -ø. 0.. 1. 8. 4... 8. 4. 1.9.9.-

Series SYJ00 Base Mounted (With sub-plate) Grommet (G), (H): SYJ 4- G H -01-Q (M 0.8) (External pilot port) 1. 8. 1 48.1 44..1. 1 9 4 - (iping port) 1 4 8. Depress and turn to operate and lock override. G: H: 00 4 4 -ø4. (Mounting hole pitch) 4. 4.8 (GZ, GS:.8). (GZ, GS:.) 4 (Mounting hole pitch) L plug connector (L): SYJ 4- L -01-Q. 1 9 4-8. (iping port) -ø4. 4 4 (Mounting hole pitch) 4. 48.1 4 (Mounting hole pitch) 1 4 1 8. 44.. M plug connector (M): SYJ 4- M -01-Q 8. 48.1 1 44..1 1 9-4 (iping port) -ø4. 4 4 (Mounting hole pitch) 4. 1.9.9 4 (Mounting hole pitch) 1 4.-4

Series SYJ00 Manifold Manifold Specifications For internal pilot Type For external pilot Manifold style (SU)/(EH) style Valve stations port Location specifications Direction / port ort size Valve effective area (mm )(Nl/min) () port port (1) Body ported style SYJ /SYJ Base mounted style SYJ 4/SYJ 4 Note 1) Only for external pilot Note ) Value when used on a manifold 1 Valve Top M 0.8 M 0.8.4 (.) How to Order Manifold ssembly 1 /8 40 40 M 0.8 1 /8 41 41 Single base style B/mount Common SU/Common EH to Base Bottom Side 1 /8 M 0.8 M:.8 (.1) 1 /8: 4. (.19) 1 /8 M 0.8,, C4 (ø4 One-touch fitting) C (ø One-touch fitting) M 0.8 M:. (1.) 1 /8: 4.8 (.01) C4, C:.8 (.1) SY SYJ VK VZ V VG Specify the part numbers for the valve(s), blank plate assembly, and manifold base. Example: SSYJ--0-Q... 1 pc. (Manifold base) SYJ1-LZ-M-Q... pcs. (Valve) SYJ00--1-Q... 1 pc. (Blank plate ass'y) SSYJ-41-0-C-Q... 1 pc. (Manifold base) SYJ-G-Q... pcs. (Valve) SYJ00---Q... 1 pc. (Blank plate ass'y) VQ VQZ Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blank late ssembly Body ported (SYJ ) Base mounted (SYJ 4) SYJ00---Q hillips head screw M., Matt nickel plated hillips head screw M., Matt nickel plated Blank plate SYJ00---Q Gasket DT0-9-8 pplicable base Sub-plate Manifold gasket SYJ00--4 Gasket SYJ00--4 Gasket SYJ00-- SYJ00--1-Q SSYJ-40 SSYJ-41 SSYJ-40 SSYJ-41 Manifold base pplicable base SSYJ-1 Manifold base pplicable base SSYJ- Manifold base pplicable base Sub-plate SSYJ-40 SSYJ-41 SSYJ-40 Manifold base SSYJ-41 hillips' head screw M., Matt nickel plated Blank plate SYJ00--1-Q Gasket SYJ00--4 pplicable base SSYJ- SSYJ-1.-

Series SYJ00 Manifolds for Internal ilot Type 40 Type 41 Type ort M 0.8 ort ort ort ort ort M 0.8, ort Manifolds for External ilot ort ort M 0.8, c, C4, C How to Order pplicable solenoid valve SYJ1- -M-Q SSYJ---- 0 -Q SYJ1M- -M-Q SYJ- -M-Q, port Thread Stations SYJM- -M-Q c (T) 0 stations pplicable blank plate ass'y 00F G (F) SYJ00--1-Q 00N NT stations 00T NTF Note) If more than stations, supply air to both sides of port and exhaust air from both sides of port. How to Order SSYJ--40-- 0 -- M 0.. Stations stations stations How to Order SSYJ--41-- 0 -- C 0...... Stations stations.. stations port side M M 0.8 01 C4 ø4 One-touch fitting C ø One-touch fitting pplicable solenoid valve SYJ- -Q SYJM- -Q SYJ4- -Q SYJ4M- -Q pplicable blank plate ass'y SYJ00---Q pplicable solenoid valve SYJ- -Q SYJM- -Q, port Thread SYJ4- -Q c (T) SYJ4M- -Q pplicable blank plate ass'y SYJ00---Q Note) If more than 9 stations, supply air to both sides of "" ort and exhaust air from both sides of "" port. ilot valve pressure is isolated from main valve pressure through a separate supply line. This is suitable for vacuum (up to -0ka) and low pressure 0.1Ma applications... M 01 port side M 0.8 F N T -Q, port Thread c (T) G (F) NT NTF Note) If more than 9 stations, supply air to both sides of port and exhaust air from both sides of port. F N T -Q G (F) NT NTF 1 Type 40 Type 41 Type.- ort M 0.8,, C4, C rotective class class III (Mark: ) ort M 0.8 ort ort ort M 0.8, ort ort (External pilot) M 0.8 ort ort (External pilot) M 0.8 ort ort How to Order SSYJ--1-- 0 pplicable solenoid valve SYJ1- -M-Q SYJ- -M-Q, port Thread pplicable blank plate ass'y Stations c (T) SYJ00---Q 0 stations 00F G (F) 00N NT stations 00T NTF Note) If more than 9 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port. How to Order SSYJ-- 40-- 0 -- 01 ort (External pilot) M 0.8 ort ort.. 0.... Stations stations.. stations port side M 01 M 0.8 pplicable solenoid valve SYJ- -Q SYJ4- -Q pplicable blank plate ass'y SYJ00---Q, port Thread c (T) F G (F) N NT T NTF Note) If more than 9 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port. How to Order pplicable solenoid valve SYJ- -Q SSYJ-- 41-- 0 -- M -Q SYJ4- -Q Stations port side pplicable blank plate ass'y 0 stations, port Thread M M 0.8 SYJ00---Q c (T) 01 stations F G (F) C4 ø4 One-touch fitting N NT C ø One-touch fitting T NTF Note) If more than 9 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port..... -Q -Q

Series SYJ00 Type Manifold: Top orted/ssyj-- Station (-F)-Q Grommet (G), (H) 4-M 0., 4. deep (Bracket mounting screw) G: H: 00 4- (/ port).1(gz, GS:.8). Depress and turn to operate and lock override.. 1 (.) 8 L4 8. SY 8 1.. 1 1 (itch) =1 1 L. n-m 0.8 ( port) -ø4. 0 SYJ VK VZ V VG -ø4. L.. 4 8. VQ VQZ L plug connector (L) M plug connector (M) 4. 1 4- (/ port).1 1 4- (/ port) 1 0 1 0.4.4 8. 8. 8. 8. Station L L L4 40 1 8 9 4 4 8 48 40 1 88 4 4 80 1 9 88 8 9 4 9 1 1 1 1 4 19 4 1 1 0 1 9 1 19 4 4 8 0 1 1 48 4 1 1 4 40 1 9 80 48 09 9 4 19 1 88 80 41 8 04 9.-

Series SYJ00 40 Type Manifold: Bottom orted/ssyj-40- Station -M, 01-Q Grommet (G), (H) 19 n-m 0.8 ( port) (itch) =1 1 G: H: 00.. 1.. 8 9.. 19 9. n- ( port) (itch) =1 1 1 4- (/ port). 4.1...1(GZ, GS:.8). 1. (itch). L =1 -ø. Depress and turn to operate and lock override. 4..1(GZ, GS:.8). 1. Depress and turn to operate and lock override. L (itch) =1. -ø. 4. Other dimensions are the same as the M. L plug connector (L) M plug connector (M)... 1 4- (/ port).. 1. 8.4.4. 8.. 4.1... 4- (/ port) ort size Station M L L.-8 4 4 8 9 80 1 4 84 9 88 0 91 1 1 1 8 9 8 8 9 1 1 9 1 0 199 190 19 1 1 1 4 8 19 41 44 8 1 0 1 84 1 01 9 1 9 8 09 08 99 19 4 1 4 40 1 9 0

41 Type Manifold: Side orted/ssyj-41- Station -M, 01, C4, C-Q Grommet (G), (H) Series SYJ00. 4.1.... 4.1.. 8. SY G: H: 00 4-.. (/ port) 1 C: M... C4: M. 8.1(GZ, GS:.8). 1. Depress and turn to operate and lock override. (itch) =1 1 (itch) 1. L =1 n-one-touch fitting ( port) C4: pplicable tube T04 C: pplicable tube T004 -ø4. 4..1(GZ, GS:.8). 1. Depress and turn to operate and lock override. ( port) n- L (itch) =1. (itch) =1. -ø. 4. Other dimensions are the same as the C4, C. SYJ VK VZ V VG L plug connector (L) M plug connector (M) With M VQ VQZ... 1 4- (/ port).. 1. 4.1. n-m 0.8 ( port) (itch) =1. 8.. 4.1... 8 C: M. C4: M. 4- (/ port).4.4.... 8 C: M. C4: M..1(GZ, GS:.8). 1. Depress and turn to operate and lock override. L (itch). =1 -ø. 4. Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Other dimensions are the same as the C4, C. ort size Station M One-touch fitting L L L 4 44 0 41 8 9 0 1 4 84 8 8 8 0 91 4 9 98 89 1 8 19 0 8 8 9 1 9 1 1 1 0 9 0 19 19 19 194 1 1 1 8 19 40 1 1 44 48 4 1 0 1 4 8 1 91 8 4 1 9 8 08 99 90 81 08 99 1 0 9 19 4 1 4 40 1 9 0 8 9.-9

Series SYJ00 1 Type Manifold: Top orted (External ilot)/ssyj-1- Station -Q Grommet (G), (H) G: H: 00.. 1.. 8 4- (/ port).1(gz, GS:.8). 4.1... 1.. Depress and turn to operate and lock override. n-m 0.8 -M 0.8 ( port). (External pilot style) (itch) L =1 L 1. 1 -ø.. 4. L plug connector (L) M plug connector (M)... 1.. 1. 8.4.4. 8.. 4.1. 4- (/ port).. 4- (/ port) Station L L.-0 4 8 9 4 94 8 9 1 1 9 1 1 1 8 9 9 14 1 19 190 1 1 19 191 1 8 9 4 4 9 1 0 1 1 8 1 1 0 9 8 09 0 19 4 19 0 41

Series SYJ00 40 Type Manifold: Bottom orted (External ilot)/ssyj-40- Station -M, 01-Q Grommet (G), (H) 19 G: H: 00.. 1.. 8 4- (/ port) n-m 0.8 ( port).1(gz, GS:.8) 9.. 4.1... 1.. Depress and turn to operate and lock override. (itch) =1 1 (itch) 1. L =1 L. -M 0.8 (External pilot port) -ø.. 4..1(GZ, GS:.8) 19 9.. 1.. Depress and turn to operate and lock override. n- ( port) -M 0.8 (External pilot port) (itch) (itch) =1 1 L =1 L 1. 1 -ø. (Mounting holes). 4. SY SYJ VK VZ V VG VQ VQZ Other dimensions are the same as the M. L plug connector (L) M plug connector (M)... 1 4- (/ port).. 1. 8.4.4. 8.. 4.1... 4- (/ port) ort size Station M L L L L 4 4 48 8 9 80 1 4 94 8 9 9 88 8 1 1 9 1 99 1 1 1 1 1 8 9 8 9 1 1 9 14 1 19 1 190 1 1 199 190 4 19 191 1 1 1 4 8 9 41 4 4 9 8 1 0 1 84 9 1 8 1 01 9 8 1 0 9 8 09 0 09 0 19 4 19 4 0 41 9 0 4.-1

Series SYJ00 41 Type Manifold: Side orted (External ilot)/ssyj-41- Station -M, 01, C4, C-Q Grommet (G), (H) M. 4.1.. 8.. 4.1... n-m 0.8 ( port) (itch) =1 19... 4- (/ port) 1 C: M... C4: M. 8.1(GZ, GS:.8). 1.. Depress and turn to operate and lock override. (itch) =1 1 (itch) L =1 L. n-one-touch fitting ( port) C4: pplicable tube T04 C: pplicable tube T004 -M 0.8 (External pilot port) -ø4.. 4..1(GZ, GS:.8). 1.. Depress and turn to operate and lock override. -M 0.8 (External pilot port) (itch) 1. L =1 L Other dimensions are the same as the C4, C. -ø.. 4. L plug connector (L) M plug connector (M). 4.1.. 8.... 4.1. 1 4- (/ port).. 8 C: M. C4: M..4.4 4- (/ port).... 1.. 8 C: M. C4: M..1(GZ, GS:.8). 1.. Depress and turn to operate and lock override. n- ( port) (itch) =1 19. -M 0.8 (External pilot port) (itch) 1. L =1 L -ø.. 4. Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Other dimensions are the same as the C4, C. ort size Station M L L L L One-touch L fitting L.- 4 4 48 8 4 8 9 80 1 4 9 4 94 8 9 9 88 8 90 81 1 1 9 1 99 9 91 1 1 1 1 1 1 1 8 9 8 19 8 9 1 1 9 9 14 1 19 1 10 1 190 1 1 199 190 4 1 19 191 1 1 19 1 4 9 8 9 41 4 19 4 4 9 8 41 1 0 1 84 9 1 1 8 1 01 9 8 8 1 0 9 8 09 0 98 89 8 09 0 0 99 19 4 19 4 0 1 1 0 41 9 0 4 4 1

ort ilot Solenoid Valve ubber Seal Series SYJ00 JIS Symbol Internal pilot SYJ1 4 SYJ 4 External pilot SYJ1 4 SYJ 4 Order Made () 1 ()() () 1 ()()..-4 Body ported Base mounted () 1 () () () 1 () () Model Valve model Body ported Base mounted (With sub-plate) SYJ1 SYJ SYJ SYJ4 Specifications ctuation N.C. N.O. N.C. N.O. Fluid Operating pressure range (Ma) Internal pilot mbient and fluid temperature ( C) esponse time ms (0.Ma) (1) Max. operating frequency (Hz) ilot exhaust Lubrication Mounting position Impact/Vibration resistance (m/s ) () ort size 1/4 Effective area (mm )(Nl/min) 9.0 (0.) 9.0 (0.) Grommet Weight (g) (Without sub-plate ) L plug connector, M plug connector. 4 4 (Without sub-plate 4) rotection structure Dust proof Note 1) ccording to dynamic performance test JIS B84-1981 (Coil temperature C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage) Vibration resistance: No malfunction occurred in a one-sweep test between 8. and 00Hz. Test was performed at both energized and de-energized states to axis and right angle directions of the main valve and armature. (Value in the initial stage) Solenoid Specifications Electrical entry Coil rated voltage (V) llowable voltage ower consumption (W) (1) Surge voltage suppressor Indicator light (1) t rated voltage DC DC ir 0.1 to 0. Max. 0 0 or less Non-locking push style, ush-locking slotted style Individual pilot exhaust style, Common Exhaust (pilot and main valve) style Not required Free /0 Grommet (G) (H), L plug connector (L), M plug connector (M) 4, 1,,, ±% rated voltage 0. (With light: 0.) Diode LED SY SYJ VK VZ V VG VQ VQZ.-

Series SYJ00 External ilot SYJ00 ilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port. This model is suitable for low pressure (less than 0.1Ma) and vacuum (up to -0ka) applications. Specifications pplicable model Operating pressure range (Ma) Base mounted (SYJ, SYJ4) Main pressure 0ka to 0. External pilot pressure 0.1 to 0. port, 1/4 / port, 1/4 port (External pilot) M 0.8 Note 1) efer to p..-40 for manifold. Note ) External pilot style body ported valves (SYJ ) can only be used on the manifold. For body ported models with the external pilot option contact SMC..-4

Series SYJ00 How to Order port 1 (For manifold type, 1) Body ported ctuation Normally closed Normally open V S 9 Order Made ated voltage 4V DC 1V DC V DC V DC V DC 0V or less Contact SMC for other voltages (9) SYJ 1 M 01 F N T S Z U Thread c (T) G (F) NT NTF Indicator light and surge voltage suppressor Without indicator light and surge voltage suppressor With surge voltage suppressor With indicator light and surge voltage suppressor With indicator light and surge voltage suppressor (Non polar) Bracket : Without bracket F: With bracket -Q Bracket is supplied unmounted expect on the external pilot style. SY SYJ VK VZ V VG Base mounted SYJ 1 4 M 01 -Q port Body option : Individual exhaust for the pilot valve : Non-locking push style ort size : Without sub-plate VQ VQZ 01: With port sub-plate For sub-plate style, manifold type 41, 4, 4 ort /E ort M: Common exhaust for the pilot and main valve D: ush locking slotted style (With gasket and screws) 0: With 1/4 port sub-plate ort /E ort : External pilot style SYJ is only for manifold use. Electrical entry 4V, 1V, V, V, V DC Grommet L plug connector M plug connector G: 00mm L : 00mm M: 00mm MN: Without lead wire lead wire lead wire lead wire H: 00mm lead wire LN: Without lead wire LO: Without connector MO: Without connector rotective class class III (Mark: ) LN and MN types are with sockets..-

Series SYJ00 Construction N.C. () N.O. () 1 ()() ey q t r w 1 ()() ey q t r w i i u u Component arts No.! " # $ Description Body iston plate End cover iston Spool valve ass'y Spool spring Material luminum die cast esin luminum die cast esin Stainless steel Note White White White eplacements arts No. & Description % Sub-plate ilot valve arts No. SYJ00-9-1-Q SYJ00-9--Q SY1- -Q 1/4 Note luminum die cast How to Order ilot Valve ssembly How to Order Connector ssembly SY1 G H L LN LO M MN MO ated voltage V S G Manual Grommet (Lead wire: 00mm) Grommet (Lead wire: 00mm) L plug connector M plug connector 4V DC 1V DC V DC V DC V DC With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Indicator light and surge voltage suppressor S Z U -Q Without indicator light and surge voltage suppressor With surge voltage suppressor With indicator light and surge voltage suppressor With indicator light and surge voltage suppressor(non-polar) DC Other C voltages Without lead wire : SY0-0-4- : SY0-0- (with connector and of sockets) Lead wire length(mm) 1 0 0 00 00 00 0 00 0 000 000.-

Series SYJ00 Body orted Grommet (G), (H): SYJ - G H -01-Q 0.8 1. - (// port) With bracket: SYJ - G H -01-F-Q 4 1. 1 ø (Manifold locating pin hole) 8 1.1 1.. 9.8 (GZ, GS: 0.8) -ø. (Mounting holes for manifold) -ø. 44. 4. (GZ, GS: 4.9) SY SYJ VK VZ 1.. Depress and turn to operate and lock override. 4 4 -ø4. V VG.. 0. (GZ, GS: 1.) G: H: 00 VQ Other dimensions are the same as the grommet. VQZ L plug connector (L): SYJ - L -01-Q M plug connector (M): SYJ - M -01-Q. -ø.. -ø. 4 1. 1 8 1.1 1.. 4.1 1 8 1.1 1. 1. 1.... 80....9 0.9.-

Series SYJ00 Base Mounted (With sub-plate) Grommet (G), (H): SYJ 4- G H - -Q 01 0 (M 0.8) (External pilot port) 1 4.. 41. 48.1 0. -1/4, (// port) 1 48 Depress and turn to operate and lock override. G: H: 00 (Mounting holes pitch) 40 4 0. 1.1 (GZ, GS: 1.8) (Mounting holes pitch) 4 -ø4. L plug connector (L): SYJ 4- L - -Q M plug connector(m): SYJ 4- M - -Q 01 0 01 0 1-1/4, (// port) (Mounting holes pitch) 40 4 81 1 48 0. 1 -ø4. 4.. (Mounting holes pitch) 4 41. 48.1 0. -1/4, (// port) 1 48 (Mounting holes pitch) 40 4.4 1.4 0. 1 4.. (Mounting holes pitch) 4 -ø4. 41. 1..-8

Series SYJ00 Manifold Manifold Specifications For internal pilot Type For external pilot Manifold style (SU)/(EH) style Valve stations port Location specifications Direction / port ort size Valve effective area (mm ) (Nl/min) () port port (1) Body ported SYJ /SYJ Base mounted SYJ 4/SYJ 4 1 1 Valve Top 1 /8 1 /8. (9.09) Note 1) Only for external pilot Note ) Value when used on a manifold M 0.8 40 Single base style/b mount Common SU/Common EH to stations Valve Top Base Bottom Base Bottom 1 /4 1 /8 1 /8 1 /8 41 41 1 /4 1 /8 M 0.8 C C8 4 4 Base Side 1 /4 1 /8 ø One-touch fitting ø8 One-touch fitting M 0.8 1 /8: 9. (00.). (9.4). (9.4) C: 8.8 (480.94) C8: (.4) SY SYJ VK VZ V VG How to Order Manifold ssembly Specify the part numbers for the valve (s), blank plate assembly, and manifold base. Example: SSYJ--0-Q... 1 pc.(manifold base) SYJ1-LZ-01-Q... pcs. (Valve) SYJ00---Q... 1 pc. (Blank plate ass'y) SSYJ-4-0-01-Q... 1 pc. (Manifold base) SYJ-G-Q... pcs. (Valve) SYJ00---Q...... 1 pc. (Blank plate ass'y) VQ VQZ Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blank late ssembly Body ported (SYJ ) Base mounted (SYJ 4) SYJ00---1-Q hillips head screw M 1, Matt nickel plated pplicable base Sub-plate SSYJ- SSYJ-1 Manifold base SSYJ-1 Gasket SYJ00-- Manifold gasket SYJ00-- pplicable base SSYJ- SSYJ-1 SSYJ-1 Manifold base Manifold gasket SYJ00--4 pplicable base Sub-plate: SYJ00-9-1/*-Q SSYJ-40 SSYJ-41 SSYJ-4 SSYJ-41 SSYJ-4 Manifold base Thread c (T) F G (F) N NT T NTF SYJ00----Q pplicable base Sub-plate: SYJ00-9-1/*-Q SSYJ-40 SSYJ-41 SSYJ-4 SSYJ-41 SSYJ-4 Gasket SYJ00--1 Manifold base Thread c (T) F G (F) N NT T NTF.-9

Series SYJ00 Manifolds for Internal ilot /1 Type 40/41 Type ort 4 Type ort ort ort ort ort ort ort 1/4 ort 1/4 ort, C, C8 ort ort 1/4 ort 1/4 ort 1/4 Valve model ort 1/4 40 40 Type 41 41 Type 0.. How to Order pplicable solenoid valve SYJ1- -01-Q SSYJ-- -- 0 - -Q SYJ1M- -01-Q Valve model, port Thread Stations SYJ- -01-Q Type c (T) SYJM- -01-Q 0 stations 1 1 Type 00F G (F) pplicable blank plate ass'y 00N NT SYJ00---Q stations 00T NTF Note) If there are more than stations in type or more than 9 stations in 1 type, supply air to both sides of "" port and exhaust air from both sides of "" port. How to Order SSYJ-- 40 -- 0 --01-0 Stations stations stations port side 01 How to Order SSYJ--4-- 0 -- C Stations stations.... stations...... port side 01 C ø One-touch fitting C8 ø8 One-touch fitting pplicable solenoid valve SYJ- -Q -Q SYJM- -Q SYJ4- -Q, port Thread SYJ4M- -Q pplicable blank plate ass'y SYJ00---Q T NTF Note) If there are more than stations in type 40 or more than 9 stations in 41 type, supply air to both sides of "" port and exhaust air from both sides of "" port. - F N c (T) G (F) NT -Q, port Thread c (T) F G (F) N NT T NTF pplicable solenoid valve SYJ- -Q SYJM- -Q SYJ4- -Q SYJ4M- -Q pplicable blank plate ass'y SYJ00---Q Manifolds for External ilot Note) If more than 9 stations, supply air to both sides of "" ort and exhaust air from both sides of "" port. ilot valve pressure is isolated from main valve pressure through a separate supply line. This is suitable for vacuum (up to 0ka) and low pressure 0.1Ma applications. 1 Type 41 Type 4 Type ort 1/4 ort 1/4 ort, C, C8 rotective class class III (Mark: ) ort ort 1/4 ort (External pilot style) M 0.8 ort 1/4 ort ort (External pilot style) M 0.8 ort 1/4 ort (External pilot style) M 0.8 ort 1/4 How to Order SSYJ--1-- 0 How to Order Stations 0 stations SSYJ-- 41-- 0 --01-0.. Stations stations stations port side 01 How to Order SSYJ-- 4-- 0 -- 01 0.. Stations stations stations port side 01 C ø One-touch fitting C8 ø8 One-touch fitting pplicable solenoid valve SYJ1- -01-Q SYJ- -01-Q pplicable blank plate ass'y SYJ00---1-Q SYJ00----Q 00N NT stations 00T NTF Note) If more than 9 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port....... pplicable solenoid valve SYJ- -Q SYJ4- -Q pplicable blank plate ass'y SYJ00---Q Note) If more than 9 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port... - -Q, port Thread c (T) 00F G (F) F N T - F N -Q, port Thread c (T) G (F) NT NTF -Q, port Thread c (T) G (F) NT pplicable solenoid valve SYJ- -Q SYJ4- -Q pplicable blank plate ass'y SYJ00---Q T NTF Note) If more than 9 stations, supply air to both sides of "" or "" port and exhaust air from both sides of "" or "" port..-40

Series SYJ00 Type Manifold: Top orted / SSYJ-- Station -Q Grommet (G), (H) 9. 4.1 40.. SY SYJ 4- (/ port).4 1. n- ( port) -ø. VK VZ G: H: 00 8 9. 0. (GZ, GS: 1.) 4..1 19. (itch) L =19 1 Depress and turn to operate and lock override. V VG VQ VQZ L plug connector (L) M plug connector (M) 9... 4- (/ port).. 4- (/ port) 8 9 8 9 80..9 0.9 4.1 0. Station L 9 8 8 4 9 8 1 4 8 9 19 1 0 1 9 8 8 8 1 0 9 1 1 1 44 4 19 8 401 91.-41

Series SYJ00 1 Type Manifold: Top orted/ssyj-1- Station -Q Grommet (G), (H) G: H: 00 9..1 0.. 1.. 9. 4 4-1/4 (/ port) 1. (GZ, GS: 1.9) 0. 1. (itch) L =19 1 1. n- ( port) -ø. Depress and turn to operate and lock override. L plug connector (L) M plug connector (M) 9.. 1. 4-1/4 (/ port). 1. 4-1/4 (/ port) 81.1. 9. 4.. 9. 4 1..1 80. Station L.-4 1 80 8 4 99 8 8 1 1 4 8 1 9 194 1 1 1 9 0 8 89 1 08 9 1 1 1 4 4 19 84 40 91

Series SYJ00 40 Type Manifold: Bottom orted/ssyj-40- Station -01-Q Grommet (G), (H) n- ( port) 8 (itch) =19 19. SY SYJ VK 9. 4.1 40.. VZ G: H: 00. 1. 8 9 4- (/ port) 0.(GZ, GS: 1.).4 4. 19. (itch) L =19 1 -ø. V VG VQ VQZ Depress and turn to operate and lock override. L plug connector (L) M plug connector (M) 9... 1... 1. 80. 8 9 8 9 4.1 4- (/ port).9 0. 0.9 4- (/ port) Station L 9 8 8 4 9 8 1 4 8 9 19 1 0 1 9 8 8 8 1 0 9 1 1 1 44 4 19 8 401 91.-4

Series SYJ00 4 Type Manifold: Side orted/ssyj-4- Station -01, C, C8-Q 41 Type: Bottom orted/ssyj-41- Station -01-Q Grommet (G), (H) SSYJ-41- Station -01-Q n- ( port) 1. 1 9..1 0. 9.. (itch) n-one-touch fitting =19 1 ( port) C: pplicable tube T004 C8: pplicable tube T080 -ø. 8. (itch) =19 1 4 G: H: 00 4-1/4 (/ port). 9. 4 C8: M.. C: M. 1. (GZ, GS: 1.9) 0. 1. (itch) L =19 1 Depress and turn to operate and lock override. 9..1 0.. Other dimensions are the same as type 4. L plug connector (L) M plug connector (M) 9..1 0. 8.. 9.. 1. 4-1/4 (/ port) 1. 4-1/4 (/ port) 1. 1 n- ( port) (itch) =19 1 81.1.1 9.. 4 C8: M.. C: M.. 80. C8: M... 9. C: M. 4 1. Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Station L.-44 1 80 8 4 99 8 8 1 1 4 8 1 9 194 1 1 1 9 0 8 89 1 08 9 1 1 1 4 4 19 84 40 91

Series SYJ00 1 Type Manifold: Top orted (External ilot)/ssyj-1- Station -Q Grommet (G), (H) 9..1 0.. SY SYJ -M 0.8 (External pilot port) G: H: 00 0. 1.. 9. 4-1/4 (/ port) 4 1. (GZ, GS: 1.9) 0. 1. (itch) L =19 1 1. n- ( port) -ø. Depress and turn to operate and lock override. VK VZ V VG VQ VQZ L plug connector (L) M plug connector (M) 9.. 0. 4-1/4 -M 0.8 1. (/ port) (External pilot port) -M 0.8 (External pilot port). 0. 1. 81.1. 9. 4. 9. 4 1...1 80. 4-1/4 (/ port) Station L 1 80 8 4 99 8 8 1 1 4 8 1 9 194 1 1 1 9 0 8 89 1 08 9 1 1 1 4 4 19 84 40 91.-4

Series SYJ00 4 Type Manifold: Side orted/ssyj-4- Station -01, C, C8-Q 41 Type: Bottom orted (External ilot)/ SSYJ-41- Station -01-Q Grommet (G), (H) n- ( port) 9..1 0. 9. n-one-touch fitting ( port) (itch) =19 1. 8. (itch) =19 1 4 -M 0.8 (External pilot port) 0. 1. C: pplicable tube T004 C8: pplicable tube T080 -ø. 9..1 0.. G: H: 00 4-1/4 (/ port). 9. 4 C8: M.. C: M. 1. (GZ, GS: 1.9) 0. 1. (itch) L =19 1 Depress and turn to operate and lock override. Other dimensions are the same as the 4. L plug connector (L) M plug connector (M) 9..1 0. 8. n- ( port) (itch) =19 1. 81.1 -M 0.8 (External pilot port) 9.. 0. 1.. 9. 4. -M 0.8 (External pilot port). 4-1/4 (/ port) 0. 1.. 9. 4 1..1 C8: M.. C: M. 4-1/4 (/ port) 80. C8: M.. C: M. Other dimensions are the same as the grommet. Other dimensions are the same as the grommet. Station L.-4 1 80 8 4 99 8 8 1 1 4 8 1 9 194 1 1 1 9 0 8 89 1 08 9 1 1 1 4 4 19 84 40 91

Series SYJ00/00/00 Made to Order (Contact SMC regarding detailed specifications, dimensions and delivery.) Order Made Specifications Series Coil rated voltage (V) ower consumption (W) Inrush Holding Specifications other than above are the same as standard models. Body ported external pilot ower Saver ower consumption is decreased by 1/ reducing the wattage required to hold the valve in an energized state. (When the rated 4V DC is applied, its effectiveness will be exhibited at an energization time exceeding ms.) How to Order SYJ T Z How to Order ated voltage 4V DC 1V DC 00 SYJ 00 T 00 4, 1V DC 0. 0. Enter symbols of specifications the same as standard pplicable solenoid valve series/syj, SYJ SYJ Operating principle The circuit shown below reduces current consumption at holding which reduces the overall power consumption. efer to following power wave form. Timer circuit Electrical circuit (For power saver style) LED Diode 1: Starting current, : Holding current 00 <ower saver style power wave SYJ 00 > 00 4V 0V 0.W 0.W 0W ms 1 pplied voltage Standard Coil ower saver ed (+) Black ( ) SY SYJ VK VZ V VG VQ VQZ Enter symbols of specifications the same as standard Operating pressure range (Ma) Operating pressure range ilot pressure range Dimensions SYJ00: 8mm longer SYJ00: 8mm longer External pilot port Series SYJ00, SYJ00 0ka to 0. 0.1 to 0. ort size M 0.8 JIS symbol Body ported N.C. () N.O. () 1 ()() 1 () ().-4