Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials
The contract entails supply of Electrical Materials for utilization of the Medium Voltage Networks that will feed electricity to the Tel Elhawa, Al Rimal Al Janobi Areas, parts of the Northern Gaza Governorates and Gaza Governorate. - All materials must adhere to technical specifications and drawings as pe the international standards subject to engineers approval.. - All items will be approved through submittal of material approval form substantiated by brochures, factory specifications and samples according to approved material supply schedule. The required Electrical components are described below: B1 M.V Wooden Poles B1.1 M.V Wooden Pole 14 m Long Top Diameter 200-220 mm Impregnated No. 24 Total of M.V Wooden Poles Carried to the main summary B2 M.V Insulators B2.1 M.V Insulator, Creepage Distance 1050 mm and 170 mm Pin with 2 Nuts 100 mm thread, (According to the Drawing No. G800) B2.2 M.V Insulator, Creepage Distance 800 mm and 170 mm Pin with 2 Nuts 100 mm thread, (According to the Drawing No. G800) No. 215 No. 178 B2.3 Tension Glass Disk (Creepage Distance 320 mm), (According to the No. 585 Drawing No. D60) B2.4 Low Tension Shackle Insulator Unit Complete for Earth line, (According Unit 128 to the Drawing No. D48) Total of M.V Insulators Carried to the main summary B3 M.V Wires B3.1 Wire ACSR Dingo 150 mm2 M 34,000 B3.2 Wire ACSR Rabbit 50 mm2 M 14,700 B3.3 Wire PN CU 70 mm2 PVC Yellow/Green M 240 B3.4 Wire 35 mm2 CU Conductor (Stranded, hard Drawn ) M 140 B3.5 Wire 35 mm2 CU Conductor (Stranded, Soft Drawn ) M 65 B3.6 Solid Copper Wire 25mm2 M 125 B3.7 Preformed Distribution Ties, 4mm2 AL M 1,250 Total of M.V Wires Carried to the main summary B4 Underground Cables & Accessories B4.1 Underground Medium Voltage XLPE Cable 18/30 (36) Kv, Single Core M 4,000 with Circular Stranded Compacted Aluminum Conductor 400 mm2), XLPE Insulated, with Copper Wire Shield 35mm2 and PVC Outer Sheathed. B4.2 Underground Medium Voltage XLPE Cable 12/20 (24) Kv, Single Core M 2,900 with Circular Stranded Compacted Aluminum Conductor 120mm2, XLPE Insulated, with Copper Wire Shield 16mm2 and PVC Outer Sheathed. B4.3 36 KV Heat Shrinkable Outdoor Termination Kit For Item (B4.1), (Set for one Phase). With Suitable Compression Lugs 400 AL/CU Set 12 B4.4 36 Kv Heat Shrinkable Outdoor Termination Kit For Item (B4.2), (Set for one Phase). With Suitable Compression Lugs 120 AL/CU Set 18 B4.5 Heat Shrinkable Straight Joint For Item (B4.1), (Set for one Phase) Set 14 including Al Joint 400 mm2 and Cu Joint 35 mm2. B4.6 Heat Shrinkable Straight Joint For Item (B4.2), (Set for one Phase) Set 7 including Al Joint 120 mm2 and Cu Joint 25 mm2. B4.7 Outdoor Metal Oxide Surge Arrestor M.C.O.V(Maximum continuous No. 30 operating voltage) 19.5 KV, Nominal discharge current 10kA and Minimum creepage distance 31mm/kV with Ground Lead Disconnector included Brackets and Cable (Set for One Phase), (According to the Drawing No. M150) B4.8 Heat Shrinkable Insulator for Lugs M 6 B4.9 Underground Warning Tape (250 m) - Caution M.V Electric Cable Turn 10 Below. B4.10 Cable Holder (Single) for fastening cables on Lattice steel Poles for Item No. 24 (B4.1) (Set for one Phase) B4.11 Cable Holder (Single) for fastening cables on Lattice steel Poles for Item No. 36 (B4.2) (Set for one Phase) B4.12 Cable Tie (sosta clamps), 50 cm Long No. 360 Total of Underground Cables & Accessories Carried to the main summary B5 Transformers & Accessories Planning Department@GEDCO UNDP/PAPP 1/3
B5.1 22/0.4 kv Low Losses 630 KVA Outdoor Pole Mounted Distribution Transformer. B5.2 22/0.4 kv Low Losses 400 KVA Outdoor Pole Mounted Distribution Transformer. B5.3 Fuse Holder Model K1750/1 Including 24 kv Surge Arrestor Set (Set for 3 phases), (According to the Drawing No. K1750-1) No. 3 No. 6 Set 6 B5.4 Fuse Holder Model K1750, (According to the Drawing No. K1750) Set 3 B5.5 22kV Glass Fuses 35 Amps, (According to the Drawing No. C10) No. 9 B5.6 22kV Glass Fuses 25 Amps, (According to the Drawing No. C9) No. 18 Total of Transformers & Accessories Carried to the main summary B6 Low Voltage Disconnectors B6.1 Low Voltage Manual Load Break 3-Poles Disconnector Combined the Item Include Fuses Base 500/630A, 3HRC Fuses 400A, 0.6/1 Kv Flexible XLPE Cable 1X185 mm2 Cu (Incoming & Outgoing Cables), Box, Plates, Compression Lugs, Steel Bolts, Nuts & Washers.and all needed to fix on Lattice steel pole, (According to the Drawing No. C400) No. 23 Total of Low Voltage Disconnectors Carried to the main summary B7 M.V Voltage Disconnectors B7.1 36 kv, 800A Switch Disconnector (Isolating Switch) with built-in arc interrupter, the Item Include 3 Complete Basic Poles With 9Composite Polymer Insulators, Load Break Device(36kv,630A), Manual Operating Device, Operating Rod, 6 Operating Rod Supports, 2 Joints, Triangular Plate for Operating on Crossarm including Fixing Arrangement for Horizontal Rod, 2 Mounting Beams L=1990 mm, Nuts/bolts for Fastening of Disconnector to Beam, Operating Shaft For Isolator L=1990 mm and Operating Lever with Rod Head, Master key lock, Compression Lugs., (According to the Drawing No. D46) No. 17 Total of M.V Voltage Disconnectors Carried to the main summary B8 Overhead Line Accessories B8.1 Dead End Tension Clamp for Wire Dingo150 mm2 ACSR, (Traizy) No. 156 B8.2 Dead End Tension Clamp Rabbit 50 mm2, for Earth Line No. 61 B8.3 Dead End Tension Clamp AL (50-70mm2), (According to the Drawing No. 35 No. CL09) B8.4 Dead End Tension Clamp AL (70-95mm2), (According to the Drawing No. 6 No. CL09) B8.5 Non Tension Clamp AL (16-120mm2) / AL (16-120mm2), (According No. 124 to the Drawing No. CL10) B8.6 Non Tension Clamp AL (50-70mm2) / AL (50-70mm2) No. 49 B8.7 Non Tension Clamp AL (16-70mm2) / AL (16-70mm2), (According to No. 20 the Drawing No. CL10) B8.8 Non Tension Clamp AL (50-240 mm2) / AL (50-240 mm2) No. 236 B8.9 Non Tension Clamp CU (10-95mm2) / CU (10-95mm2), (According to No 51 the Drawing No. CL11) B8.10 Non Tension Clamp CU (6-35 mm2)/ CU (6-35 mm2), (According to the Drawing No. CL08) No. 46 B8.11 Non Tension Clamp AL (25-150mm2) / CU (10-95mm2), (According to the Drawing No. CL12) No 25 B8.12 Tension Joints for Wire Dingo 150 mm2, AL, Fargo - GL410, (According to the Drawing No. CL19) B8.13 Tension Joints for Wire Rabbit 50 mm2, AL, Fargo - GL406, (According to the Drawing No. CL18) B8.14 Compression Terminal Lug For 120 mm2 CU With 13 mm Hole, (According to the Drawing No. CL15) B8.15 Compression Terminal Lug For 70 mm2 CU With 13 mm Hole, (According to the Drawing No. CL15) B8.16 Compression Terminal Lug For 35 mm2 CU With 13 mm Hole, (According to the Drawing No. CL16) B8.17 Compression Terminal Lug For 70 mm2 AL With 13 mm Hole, (According to the Drawing No. CL17) No. 20 No. 15 No. 20 No. 102 No. 111 No. 115 Planning Department@GEDCO UNDP/PAPP 2/3
B8.18 Compression Terminal Lug For 70 mm2 AL/CU With 13 mm Hole, B8.19 Compression Terminal Lug For 95 mm2 AL/CU With 13 mm Hole, B8.20 Compression Terminal Lug For 120 mm2 AL/CU With 13 mm Hole, B8.21 Compression Terminal Lug For 150 mm2 AL/CU With 13 mm Hole, No. 52 No. 28 No. 18 No. 90 Total of Overhead Line Accessories Carried to the main summary B9 Earthing Components B9.1 Earth Rod 15mm Diameter 1.5 m Long, (According to the Drawing No. D52) No. 116 B9.2 Earth Rod Joint 15 mm Diameter No. 62 B9.3 Earth Rod Connection Clamp No. 74 B9.4 Tension Omega (Big) for Wooden Poles No 25 Total of Earthing Components Carried to the main summary Planning Department@GEDCO UNDP/PAPP 3/3
Summary Item B1 B2 B3 Total of M.V Wooden Poles Total of M.V Insulators Total of M.V Wires Description Amount B4 B5 B6 B7 B8 B9 Total of Underground Cables & Accessories Total of Transformers & Accessories Total of Low Voltage Disconnectors Total of M.V Voltage Disconnectors Total of Overhead Line Accessories Total of Earthing Components Total Discount Rate ( %) Discount Amount Net Total of Lot 2 - Electrical Materials NET TOTAL SUM (in words ) : SIGNED AND SEALED : AUTHORIZED : TITLE : SIGNATURE : DATE : Planning Department@GEDCO UNDP/PAPP Summary - Page 4