Installation Guide. Marking and Inspection Gauge. Marking Gauge. Inspection Gauge E 1. Marking and inspection gauges are combined into one gauge.

Similar documents
DAP-625S and DAP-875S

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Straight-Bore Clutch LSCC-32, 44, 54

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Compressor Clutch Replacement Procedure

SPL HICAS ELIMINATOR KIT

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

Instruction Sheet. SFR Series. Swing Frame rack

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Compressor Clutch Replacement Procedure

IMPORTANT SAFETY INFORMATION

MAINTENANCE NOTE: ANY LEAK FROM THE MAIN BODY OF THE LOAD IS AN INDICATION THAT THE UNIT SHOULD BE RETURNED TO THE FACTORY FOR REPAIRS.

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

HR-20P Pneumatically Controlled Pressure Regulator

Mechanical Spiral Sensor

CRD400 Fitting Inserter OPERATIONS MANUAL

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

Female Plug. connecting to Fuel Quantity

CU6703 Module Installation Guide

4-Ton Electric Log Splitter

CRD610 Automatic Fitting Inserter

30100 Module Installation Guide L

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

20250 Module Installation Guide

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

SOLAR DASH CHARGING SYSTEM USER GUIDE

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

84in. Driveway Drag. Owner s Manual

15100 Module Installation Guide Mercedes EPA07 w/dpf

25 GALLON PORTABLE OIL LIFT

Premium Pond Pump 330 Gallons Per Hour

Smartflow FasTie Quick-Connect Ejector Tie-In System

HEAVY-DUTY STEEL WAGON

6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

Fitting Instruction for EZI-GRIP Bike Rack

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

"WHERE TUBING AND FITTINGS COME TOGETHER"

Submersible Pond Pump with UV 800 Gallons Per Hour

Premium Waterfall Pump 1200 Gallons Per Hour

Microscope light manual

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

3-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Installation & Operators Manual

Yukon Gear & Axle. D30, D44 & GM 8.5" Hardcore Locking Hub Installation Guide PLEASE READ COMPLETELY BEFORE INSTALLATION

MLS DEFENDER SOCCER TABLE ASSEMBLY INSTRUCTIONS

ATD Gallon Pressurized Oil Drain Owner s Manual

Yukon Gear & Axle D60 Hardcore Locking Hub Installation Guide

Pressurized Pond Filter Up to 850 gallons

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

3000-Lb. Vehicle Positioning Jacks. Owner s Manual

LBH / LBFR SERIES. Instruction Sheet. Telescoping Lacer Bar

INSTALL GUIDE Silverado/Sierra L/6.2L

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

16K and 19K Sidewinder TM Service Kit Instructions 86005

SYSTEM MANUAL. Automated Motorized Hydraulic Traffic Controller. Revision CS72-HTC

END USER TERMS OF USE

FCB-450, LCB-600, MCB-800

Submersible Waterfall Pump 1200 Gallons Per Hour

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

TBM Series 3-Way Ball Valve

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

DeZURIK 2 20" BOS BUTTERFLY VALVES

HURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS

Power Float Manifold. Installation and Operations Manual Module 11A

Harvil 4 Foot Air Hockey Table

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Heavy-Duty Sawhorse. Owner s Manual

MEX (55) QRO (442) Web Controls

CRD600 Automatic Fitting Inserter

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

TONS. Before each shift: Before operating: Before initial operation of hoist:

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

Mechanical Filter Box Kit

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Service Guide JATCO Environmental Protection Tank Model J-7000

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

ACP ADAPTIVE CARBINE PLATFORM

Natural Fiber Planter Fountain

Container Fountain Kit with LED Light

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

37SCENE 46SCENE 79SCENE

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

JDCR2000 Module Installation Guide

Heavy-Duty Drywall Dolly Cart

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

OWNERS MANUAL HF4263

Illumifalls Patio Pond

Instruction Sheet AX-SXR SERIES. Rotating Equipment Access System

We greatly appreciate your business and promise to work hard to provide you with the highest level of service at all times.

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS

SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS

INSTALL GUIDE Dodge/RAM 5.7L HEMI

JD2800 Module Installation Guide

Transcription:

Marking and Inspection Gauge Marking and inspection gauges are combined into one gauge. Marking Gauge The gauge has a pin and a slot for marking along the centerline. Position the pin with the end of the pipe and make a mark inside the slot for locating the fitting on the pipe. Inspection Gauge Inspection gauges have two cutouts one on each of the long sides of the gauge. Use these cutouts to verify the pipe minimum and maximum OD. The gauge has a cutout on the middle of the short side of the gauge. This cutout has three points for verifying the after swage dimension of the joint. The gauges are marked with the part number, and size of pipe. 1

Pipe Preparation Pipe nd Preparation Pipe end preparation is important to assure good contact area between the pipe and the seal within the fitting. The preparation involves the following steps: Pipe Cutting Pipe Deburring Outside Diameter Clean-up Pipe Cutting Using a straight edge, make sure that the pipe end is straight to allow the fitting to slide over the pipe upon insertion. Protect the pipe from wrench and vise grip damage, and cut the pipe to proper length. Tube-Mac highly recommended that the cut is less than 3 off square of the pipe end, but a cut up to 5 off square is acceptable. Pipe Deburring Pipe deburring and removal of raised nicks and burrs eliminates the potential for damage to the fitting seals during pipe insertion. A 30 chamfer will help in the pipe insertion. Outside Diameter Clean Up Clean the outside surface of the pipe for a minimum of one pipe diameter length. Blend surface flaws, scratches, concavities and flats, paint and galvanizing with emery cloth, without reducing the diameter below the minimum. 2

Pre-Installation Procedures Select the proper Tube-Mac Pyplok tooling, i.e.; power unit and head assembly. Prepare pipe ends. Verify the pipe OD and ensure it is free of any damage. nsure fitting seals are in-place. Select appropriate Marking/Inspection gauge. All gauges are marked with applicable Pipe or O.D. Tube size. Using PMAX gauge, check the outside diameter of the pipe. Verify the pipe size by placing the fitting over the pipe and examine the fit. Using the PMIN gauge verify the PMIN dimension by placing it over the outside diameter of the pipe. The PMIN gauge must NOT fit over the pipe. This check helps to ensure proper Marking/Inspection gauge use. Place the gauge on the pipe with the stop pin pressed against the pipe end. Apply an insertion mark through the marking window. CAUTION: Hydraulic pressure for the swage tools must not exceed 10,250 PSI. Minimum of 80 PSI shop air is required for operation of the Pneumatic pump. 3

Installation Procedure Insert the pipe into the fitting keeping the rotation and twisting to a minimum. You will encounter slight resistance when inserting the pipe past the seal ring. Position the end of the fitting over the pipe installation mark so that some portion of the mark is visible. This is important to ensure proper inserting depth and to complete an acceptable swage. Install the lower die block assembly onto the upper piston of the power unit. Place the yoke (head with the upper dies in-place) over the pipe adjacent to the fitting end. ngage the power unit assembly into the yoke. nsure the ball detents in the lower die block engage the grooves in the yoke. CAUTION: Full engagement of the head with the power unit is critical for the safety of the operator and the tool. Connect the hydraulic power supply Activate the hydraulic power supply to the proper pressure and then release it after reaching the desired pressure. Disengage the yoke from the power unit - the swaging is now complete. NOT: Typically, there are two raised bands near each end of a Tube-Mac Pyplok fitting called seal diameter and retention diameter seal bands. In some cases, you must swage fittings more than once on each end of the fitting to compress the seal diameter and retention diameter bands. Whether it takes one, two or three swages depends on the type and size of the fitting and the condition of the swage dies. 4 Details are provided in the Pyplok Installation Manual as well as during training, sessions provided by Tube-Mac.

Inspection of the Swage Joint Visual Inspection Verify the width of the swage completely covers the raised retention and seal areas Pipe Insertion Verification Inspect the pipe insertion mark Verify that the fitting covers a portion of the pipe installation mark and a portion is clearly visible In the event that the installation mark is not clearly visible, use the inspection mark to verify proper insertion. Position the marking tool against the fitting end, placing the side with the pin stop away from the pipe, and orient the inspection mark to verify that some portion of the inspection mark is visible in the gauge window or between the dot and the fitting end. Swage Diameter Verification Place the inspection gauge over the swage At two positions, approximately 90 apart verify both the seal and retention swages An acceptable swage is a minimum of 2 point contact 90 apart between the swaged area and the inspection gauge must be satisfied An unacceptable swage is when there is 2 point contact 180 apart If the swage fails to meet the inspection criteria, the fitting can be re-swaged. 5

Limited Warranty TUB-MAC INDUSTRIS WARRANTS ITS PRODUCTS TO B FR FROM VISIBL DFCTS IN MATRIALS AND WORKMANSHIP FOR A PRIOD OF ON (1) YAR FOLLOWING TH DAT OF DLIVRY TO TH ORIGINAL BUYR. TH WARRANTY XTNDS ONLY TO TH ORIGINAL BUYR. TUB-MAC INDUSTRIS makes no warranty, express or implied, as to the merchantability or fitness for a particular purpose except as stated in this Warranty. This Warranty shall be in lieu of any other Warranty, whether express or implied, by this Agreement or at law or in equity or by any statute or otherwise. The Buyer agrees that the foregoing shall be pleaded by TUB-MAC INDUSTRIS as an estopel in any action brought by the Buyer against TUB-MAC INDUSTRIS. The Buyer agrees that porosity or pin holes in steel may not be commercially detectable. Therefore, TUB- MAC INDUSTRIS offers no warranty with respect to steel integrity and TUB-MAC INDUSTRIS shall not be liable for any damages, claims, injuries or otherwise caused by or in any way related to steel integrity. TUB-MAC INDUSTRIS liability shall be limited to the repair or replacement of defective product(s) free of charge at the seller s sole option and discretion. TUB-MAC INDUSTRIS reserves the right at its sole option and discretion to refund a portion or all of the purchase price paid by the Buyer in lieu of any other obligations TUB-MAC INDUSTRIS has under this Warranty. In no event shall TUB-MAC INDUSTRIS be liable for any incidental, consequential, general or special damage of any kind or nature whatsoever including but not limited to loss of profit arising out of any incident(s) involving the use or utilization of the product and/or system covered under this Warranty. In no event shall TUB-MAC INDUSTRIS be liable for any personal injury or any special or general damages arising out of the personal injury of any kind or nature whatsoever. TUB-MAC INDUSTRIS shall not be liable under this Warranty or otherwise if damages to the product are caused as a result of any type of accident or in the event the product and/or system was subject to alteration, abuse, misuse, extraordinary use of any kind whatsoever, improper maintenance or operation or improper or unauthorized repair. TUB-MAC INDUSTRIS makes no warranty whatsoever as to any product and/or system covered by this Warranty which has been repaired or altered by anyone other than TUB-MAC INDUSTRIS or authorized personnel. TUB-MAC INDUSTRIS neither assumes nor authorizes any person to assume for it any other liable in connection with the sale of such products and/or systems. WARNING: Failure or improper selection or improper use of the products and/or systems described herein or related items can cause death, personal injury and property damage. 6