Rectangular Butterfly Valve

Similar documents
740G Double Disc Check Valve

720G Wafer and 821G Globe Style Silent Check Valves

3" 20" Bonded Seat Butterfly Valves

24 and Larger Butterfly Valves

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

INSTRUCTION MANUAL RECTANGULAR BUTTERFLY VALVE 3-SIDED SEAT

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

ISO RESILIENT WEDGE GATE VALVE. Engineering Creative Solutions for Fluid Systems Since 1901

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

RECTANGULAR BUTTERFLY VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

Metal Seated Ball Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: MSBVOM Revision Date: 07/06/09

MANUAL VALVE ACTUATORS. Engineering Creative Solutions for Fluid Systems Since 1901

COMPACT CHECK VALVES Engineering Creative Solutions for Fluid Systems Since 1901

720A Wafer & 821A Globe Style

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

BALL VALVES. Industry-Leading 300psi Low Lead Ball Valves

Henry Pratt MDT Actuators. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #MDTOM Revision Date: 1/12/11

HP250II AND HP250 BUTTERFLY VALVES Engineering Creative Solutions for Fluid Systems Since 1901

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

ISO-DE Double Eccentric Butterfly Valves

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DeZURIK G-SERIES MANUAL ACTUATOR USED ON BOS BUTTERFLY VALVES

METAL SEATED BALL VALVE Engineering Creative Solutions for Fluid Systems Since 1901

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

DeZURIK M-SERIES MANUAL ACTUATOR

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

Val-Matic 3"-24" Butterfly Valve With LSA Actuator and External Stops

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

Val-Matic 30" and Larger Butterfly Valve With LSA Actuator and External Stops

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

Val-Matic 30" and Larger Butterfly Valve With LSA Actuator and External Stops

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

MULTI-PORT PLUG VALVE Engineering Creative Solutions for Fluid Systems Since 1901

Lineseal Butterfly Valves 150B, 250B, & 350B Class; Sizes 3-48

DeZURIK 2 20" BOS BUTTERFLY VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

MANUAL ACTUATOR FOR KNIFE GATE VALVES

CUSTOM COMBINATION AIR VALVE

Val-Matic 3-72 Cam-Centric Plug Valve

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

DeZURIK MANUAL G-SERIES ACTUATORS USED ON PEC ECCENTRIC VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Sentinel 250 Fire Hydrant

BF Series Wafer/Lug Butterfly Valves

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

MUELLER GAS. No-Blo Valve. Changers. Reliable Connections. General Information 2-3. Plugging Unit Assembly 4-5. Removing Old Valve 5-6

CSA products for treated water. Water Combination air valve. Mod. FOX 3F RFP and Lynx 3F RFP

Val-Matic 4-20 Air/Vacuum Valve

PO Box 411 Berwick PA VALV

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

CSA products for waste water. Combination air valve. Mod. SCF 2

Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime.

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

DeZURIK VPB V-PORT BALL VALVES

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

Installation instructions

DeZURIK R1 AND R2 POWERRAC ACTUATORS

Val-Matic 3-Way Tapered Plug Valve

Installation, Operation, and Maintenance Manual

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

MUELLER. Centurion Series Fire Hydrant. Centurion Super Centurion 200 Super Centurion 250. Reliable Connections. Background and Forward 2

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

Installation, Operation, and Maintenance Manual

Fabricated Bevel Gear Operator Bi-Directional Metal Seat 150 PSI Bi-Directional Resilient Seat 150 PSI

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

FIRE HYDRANTS. Wet Barrel Fire Hydrants

DEMCO Resilient Seated Butterfly Valve

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

SERIES 300 PLUNGER VALVES

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

DeZURIK 2-16" PTW & PFW TAPERED PLUG VALVES

I-BFV.KIT Butterfly Valve Gear Operator Replacement

DeZURIK PEC ECCENTRIC VALVES

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES

Fabri-Valve XS150. Knife Gate Valve

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

DeZURIK KUL KNIFE GATE VALVES

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

APCO CSV-1600 SURGE CHECK VALVE

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT

AMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT

Transcription:

OPERATION/MAINTENANCE MANUAL Rectangular Butterfly Valve TABLE OF CONTENTS PAGE General Information 2 Installation and Operating Instructions 3 Maintenance and Troubleshooting 4 Parts Information 5 WARNING: 1. Read all applicable directions and instructions prior to any maintenance, troubleshooting or installation. 2. Personnel involved in the installation or maintenance of valves should be constantly alert to potential emission of pipeline material and take appropriate safety precautions. Always wear suitable protection when dealing with hazardous pipeline materials. 3. Order parts from your local Pratt sales representative or directly from Pratt. When ordering parts, please include the serial number located on the valve tag. NOTE: WARNING and CAUTION messages (flagged with an exclamation symbol) indicate procedures that must be followed exactly to avoid equipment damage, physical injury, or death. F 13803 11/18

RECTANGULAR BUTTERFLY VALVE General Information / Installation FUNCTIONAL DESCRIPTION Rectangular butterfly valves are designed with both three and four sided disc seating surfaces. The discs rotate 1/4 turns to provide shutoff in reservoirs and conduits. Three sided seating valves will provide tight shutoff in an open conduit. Four sided seating valves will provide tight shutoff in closed conduits and reservoirs. The valves can be used to regulate flow rate by positioning the disc between 15 and 90 degrees open. Manually operated butterfly valves are powered with gear actuators, which convert multiple handwheel, chainwheel or nut input turns into 1/4 turn valve operation. The travel of the valve disc is limited by physical stops in the actuator housing. CAUTION: Forcing the handwheel, chainwheel or nut against the stops will not provide tighter shutoff of the valve and may damage the actuator. Only actuator adjustments will affect valve shutoff. Motor operated butterfly valves are powered with gear actuators, which convert multiple motor input turns into 1/4 turn valve operation. The travel of the valve disc is limited by limit switches in the motor housing and physical stops in the actuator housing. Valve shutoff is affected by limit switch and physical stop settings. CAUTION: Improperly set limit switches and/or physical stops may damage the motor and/or actuator. Hydraulically operated butterfly valves are powered with a gear box and double acting cylinder. The linear stroke of the cylinder is converted to 1/4 turn operation by the gear box. Auxiliary controls are provided to direct hydraulic power to the cylinder and to control the operating speed of the cylinder. INSTALLATION Refer to the mechanical general arrangement drawings prepared for this specific valve during installation. The flow direction and actuator orientation are given on the drawing. The valve should be installed with the disc in the closed or near closed position to prevent damage to the disc edge. Insert the lifting sling through the opening of the valve to lift the frame. CAUTION: DO NOT lift the valve assembly by slinging the actuator only. The butterfly valve should be bolted to the wall frame with a 1/4" thick soft (40 50 durometer) rubber gasket. Studs or bolts can be used with bevel washers on the valve side of the connection. With the valve fully mounted, the position of the actuator should be verified. If the actuator position must be changed to accommodate field problems, the factory should be contacted to provide a procedure or assistance in its change. WARNING: All persons who will install, operate or adjust this equipment must read the instructions and drawings carefully. Injury and property damage may occur from improper use. It is understood that this equipment will be installed by individuals with knowledge and skills in electrical equipment. The manufacturer cannot be responsible for the misuse of this information or equipment, nor can it assume any resultant liability. 2

RECTANGULAR BUTTERFLY VALVE Start-Up Procedure / Operation START-UP Manually Operated Manually operated valves should be fully cycled from open to close and back to the closed position to verify operation. DO NOT force the valve in the closed position if tight shutoff is not achieved; make adjustments to the actuator per the maintenance instructions. Motor Operated Motor operated valves should be operated through three complete cycles to verify operation. The valve should then be closed and water pressure applied to one side of the valve. The seat bolts can be tightened to eliminate any leakage. Cylinder Operated Connect the specified hydraulic pressure to the cylinder and controls. All hydraulic supplies must be filtered to prevent contamination and clogging of the controls. The valve can be cycled open and closed by switching the cylinder control solenoid either electrically or manually. OPERATION Manual Actuator Function and Use The manually operated rectangular butterfly valves are operated by rotating the handwheel, chainwheel, or nut. The actuator is equipped with gearing to convert the many turns into 1/4 turn operation. Inside actuator stops that limit the travel of the valve are pre-set at the factory. Prior to initial operation the valve should be fully cycled from close to open and back to closed position. DO NOT force the valve if tight shutoff is not achieved; make adjustments to the actuator per the maintenance instructions. Forcing the handwheel, chainwheel, or nut will not cause the valve to shut off any tighter and may cause damage to the gearing. Cylinder Operator Function and Use The cylinder operated rectangular butterfly valves are operated automatically by directing hydraulic pressure to either side of the power cylinder. Solenoid valves are used to direct the fluid to the cylinder ports based on electrical power signals. In cylinder actuators, the travel stops are in the cylinder so that full hydraulic pressure can be held on the cylinder at either end of travel. Prior to initial operation, connect the specified hydraulic pressure to the cylinder and controls. All hydraulic supplies must be filtered to prevent contamination and clogging the controls. The valve can be cycled open and closed by switching the cylinder control solenoid either electrically or manually. Motor Actuator Function and Use The motor actuator is designed to open and close the valve through its one quarter turn of rotation. It contains gearing so that hundreds of turns of the motor or handwheel will slowly move the valve from open to close position in about 60 seconds or vise versa. Electrical controls are included in the motor actuator for local electrical control. The output motion of the actuator is limited to about 100 degrees of output rotation by mechanical stops in the gearing. These are factory set and should not need adjustment. The actual positioning of the valve disc will be done by limit switches in the motor actuator. The switches are also set at the factory but adjustment is sometimes required if the motor unit is installed on a separate mounting base or floorstand. Detailed procedures are given in the motor manual if adjustment is needed for the mechanical stops or the limit switches. The wiring and power requirements are given on wiring diagrams included in this instruction manual. The limit switches should be set so that the disc edge is centered over the rubber seat. DO NOT allow the motor actuator to torque the valve into the valve disc stops, or premature failure to the valve or motor may occur. Prior to initial operation, the valve should be operated through three complete cycles to verify operation. The valve should then be closed and flange bolts can be tightened to eliminate any leakage. Refer to the motor actuator instruction manual for start-up information. WARNING: All persons who will install, operate or adjust this equipment must read the instructions and drawings carefully. Injury and property damage may occur from improper use. It is understood that this equipment will be installed by individuals with knowledge and skills in electrical equipment. The manufacturer cannot be responsible for the misuse of this information or equipment, nor can it assume any resultant liability. 3

RECTANGULAR BUTTERFLY VALVE Maintenance / Troubleshooting MAINTENANCE The following actions are recommended to be performed annually to ensure proper operation of your valve. 1. Cycle valve to verify operation and no interference in line. 2. Close valve and check for leakage. If leakage is found, check actuator stops to verify that the disc is fully closed. If leakage persists, inspect seat. If damage is found, contact the Pratt Field Service Department immediately. 3. Check flange connections for leakage. Tighten bolts accordingly. 4. Check top trunnion area for shaft leakage. If leakage is detected, replace valve packing. Contact the Pratt Field Service Department for procedure to replace valve packing. 5. If access to line is possible, then removal of scale that may interfere with the disc travel is suggested. 6. Should be inspected for wear and taper pin nuts should be tight. 7. Lubrication of the valve is not required. 8. Stocking of spare parts not recommended. TROUBLESHOOTING PROBLEM CAUSE SOLUTION Leakage between valve and Packing leak Clean packing bore and replace actuator packing Bottom trunnion leaks Packing or gasket Replace bottom shaft packing, O-ring or gasket Valve leaks when closed Disc not fully closed or past fully Adjust actuator closed stop closed position Disc edge wear or damage Clean and/or repair disc edge Rubber seat wear or damage Adjust or replace valve seat Loose debris in valve Cycle valve five times to flush out debris Valve hard to operate Foreign material in valve Remove obstructions Corroded operator parts Clean and grease actuator Loose actuator Tighten actuator and mounting 4

A RECTANGULAR BUTTERFLY VALVE Parts Information PARTS LIST 18 ID DESCRIPTION MATERIAL 1 Body Assembly Carbon Steel A-500 GR B 2 Disc Assembly Carbon Steel ASTM A-36* 3 Top Stub Shaft 304 Stainless Steel ASTM A-276 4 Bottom Stub Shaft 304 Stainless Steel ASTM A-276 SECTION A A 5 Taper Pin 304 Stainless Steel ASTM A-276 6 Hex Nut 304 Stainless Steel 7 Lockwasher 304 Stainless Steel 8 Key Cold Drawn Steel AISI C-1045 8 6 20 12 9 10 21 3 11 22 9 Thrust Bearing Plate Bronze SAE 660 10 Thrust Bearing Collar Carbon Steel ASTM A-36 11 Stud Carbon Steel GR 2 12 Bearing Teflon Lined, Fiberglass Backed 13 Hex Head Cap Screw 304 Stainless Steel 16 7 6 5 1 2 14 Segment Retainer 304 Stainless Steel ASTM A-276 15 Bottom Cover Carbon Steel ASTM A-36 16 Seat Hycar 50-DURO 17 Gasket Granite 18 Sealant RTV 19 Hex Head Cap Screw Carbon Steel GR 8 A 20 V-Type Packing Fabric Reinforced Neoprene or BUNA-N 21 Packing Retainer Ring Nylon 101 22 Packing Retainer Plate #10 Gauge Sheet Steel (C-1018) *With Stainless Steel ASTM A-276 Type 304 Edge 7 6 14 17 13 5 4 12 15 TO ORDER: Contact our Parts Department. Pratt 401 South Highland Avenue Aurora, IL 60506-5563 Attn: Parts Manager 630.844.4000 18 19 When ordering parts, please include the serial number located on the valve tag and description of part requested. 5

MUELLER ECHOLOGICS HYDRO GATE HYDRO-GUARD JONES MI.NET MILLIKEN PRATT SINGER U.S. PIPE VALVE & HYDRANT 1.800.423.1323 www.prattvalve.com moreinfo@muellercompany.com INTERNATIONAL 1.423.490.9555 www.mueller-international.com international@muellercompany.com Mueller refers to one or more of Mueller Water Products, Inc., a Delaware corporation ( MWP ), and its subsidiaries. MWP and each of subsidiaries are legally separate and independent entities when providing products and services. MWP does not provide products or services to third parties. MWP and each of its subsidiaries are liable only for their own acts and omissions and not those of each other. MWP brands include Mueller, Echologics, Hydro Gate, Hydro-Guard, Jones, Mi.Net, Milliken, Pratt, Singer, and U.S. Pipe Valve & Hydrant. Please see www.muellerwp.com/about to learn more. Copyright 2018 Henry Pratt Company, LLC. All Rights Reserved. All Rights Reserved. The trademarks, logos and service marks displayed in this document are the property of Mueller Water Products, Inc., its affiliates or other third parties. Products above marked with a section symbol ( ) are subject to patents or patent applications. For details, visit www.mwppat. com. These products are intended for use in potable water applications. Please contact your Mueller Sales or Customer Service Representative concerning any other application(s).