Technical Specification

Similar documents
PRECISION UK Ltd DUPLEX AGSS PLANT

Axis AGSS TERMINAL UNITS

CPX DUPLEX MEDICAL VACUUM PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Technical Datasheet. SP Terminal Units. Classification. Services. Terminal Block. Check Valve Assembly. Tailpipe Options

Axis MEDICAL GAS TERMINAL UNITS

PRECISION UK Ltd. Medical Gas Outlet BS Standard

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Slim Style Compatible

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

SIDE CHANNEL BLOWERS

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

M Series Condensate Recovery Unit

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Compatible

CEGA FORANO BY GREGGERSEN

Roots Packaged Blower Units

Swimming Pool CSR2 Heat Recovery Equipment

Bifurcated Case Axial Fans (BIFA)

Dental Vacuum System. Installation Overview

MINISCAV Scavenging Vacuum Pump

H.S. MACHINERY RING COMPRESSORS

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Instruction Manual. Q Series 2 Motor Control Modules - OEM

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

Grey Water and Condensate Pump. Rotex. Type Series Booklet

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Rotary Tooth Air Compressor System

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

Rotary Tooth Air Compressor System

PowerAir Compressor Installation

Eminox Electronic Service Indicator

SurePower Battery Pack Guide

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

READ AND SAVE THESE INSTRUCTIONS

Swing Piston Compressors and Vacuum Pumps

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Etaline MN. In-line Pumps

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

GMP-Type. Key Features: Integrated Motor-Pump Units

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

High-pressure compressor for breathing air Type MX 250 open and MX 300 open. Maximum Pressure. A power package with allrounder qualities

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

MAJAX-2 GENERAL SPECIFICATION

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

Novenco Tunnel Fans. Novax October 2007

Differential Pressure Switch QBM81-

The Mikrofill Electronic Filling Device. (EFD)

BATTERY SAVER LOW RIPPLE HO

PRE-INSTALLATION GUIDE

SurePower TM II Battery Pack Guide

XLP Extra Low Pulse Blower

Model DS1000/DT20 System

Diesel Engine Shutdown System

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Small diaphragm vacuum pumps

Service and Parts Guide: Matrx Central Scavenger Waste Anesthetic Gas Disposal System

Ventilation Blowers 09. Introduction Heavy Duty Radial Blowers Radial Blowers In-Line Blowers

2.7. IT system floor-standing distribution cabinet Series -IPS-F

AC Commercial Fans Edition. ErP ready

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

WELDING FUME EXHAUSTERS & ARMS

Air-Cooled Liquid Chiller with integrated hydraulic module

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Liquid Particulate Filters and Coalescers

V1606 3U RACK ENCLOSURE

MANN+HUMMEL IQORON The new compact air cleaner for high requirements

OPERATIONAL INSTRUCTIONS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

D-Series Blowers and Exhausters

forward curved inline duct blowers

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

SECTION VACUUM SYSTEM PROCESS PIPING

Dry installed pump type LANDY BTP.

QUIETSCROLL TWIN FAN RANGE

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

TRIVAC NT 16 and NT 25

Sentry Governors. Class 1. Advanced Diagnostics. Sentry Governor Kits

Environmental Technology Linear Diaphragm Pumps Side Channel Blowers Diffusers.

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

VT Oil-Free Range Operators Handbook

Installation manual. SCR system. Marine engines DI13, DI16. 02:07 Issue 4.0 en-gb. Scania CV AB 2017, Sweden

User s Manual D-Series Blowers and Exhausters

POWERBUS 225 Busway and Plug-In Units

AC Induction Motors. Installation and operating instructions

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Transcription:

Technical Specification Agss Plant Product Description Active anesthetic gas scavenging systems should be designed to safely remove exhaled anesthetic agents from the operating environment and dispose of them to atmosphere, thus preventing contamination of the operating department and providing a safe and healthy workspace for the personal. AGSS design should be dependent upon flow rate and pressure drop characteristics of the individual components of a systems, it is essential that terminal units, remote controls and pump units. The anaesthetic gas scavenging system (AGSS) shall comply with United Kingdom Department of Health (DoH) HTM02-01, HTM2022 and EN ISO 7396-2 Medical Gas Pipeline System. The AGSS shall be a dedicated, specifically designed active extraction and disposal for waste anaesthetic gas. It shall provide a maximum flow rate of 80 l/min with 1 kpa resistance to flow, and a minimum of 50 l/min with 2 kpa resistance at each terminal unit, irrespective of the number of terminals in use. The AGSS

system shall use dedicated radial blowers in a simplex or duplex configuration. The AGSS pump assemblies shall be skid mounted and included on the skids shall be the simplex or duplex pump(s), motor control unit(s), with starter/isolator, moisture drain flask and flexible connector(s) to connect the plant to the pipeline system. Each pump shall include an electric motor and directly coupled impeller assembly. Impeller bearings in the pump(shall not require lubrication. The pump(s) shall be air cooled and rated for continuous operation. Duplex AGSS System with twin die cast aluminum side channel pumps Air cooled electric motor direct coupled impeller assembly of 3phase 2500 Lpm 2.2kw capacities each with built in flow indication and pressure regulation valve. Each pump shall include a swing no spring type non-return valve to enable safe and efficient maintenance of 1 pump while the other pump is in service.it should be mounted on a single frame with a central control panel and separate warning label. The AGSS Plant is intended for use with terminal units complying with BS 6834 which have a maximum resistance to flow of 70 mbar at 130 l/min Vacuum/Flow Regulating Valve A vacuum/flow regulating valve shall be provided and positioned at the pump, comprised of a spring loaded plate valve and inlet silencer. The valve shall be changeable with the pipeline inlet in order to provide flexibility on site. The plate shall control air ingress into the pipeline system, thereby controlling the vacuum level within. An optional air inlet filter shall be available should the air quality be poor/dusty offering further protection against dirt ingress into the pump. Additional in line vacuum/flow regulating valves may be installed if required and shall be determined by the pipeline designer. The vacuum/flow regulator shall ensure a maximum vacuum of 200mb below atmospheric pressure is not exceeded and shall be factory preset at 150mb. Control system Each motor control panel shall incorporate an emergency isolation switch which controls all electrical power to the exhauster unit and system indication lights. All control and status indication circuitry shall be 24V AC A green normal indicator shall indicate the system is in a normal state. An amber plant fault indicator will illuminate if a plant fault occurs A red plant emergency indicator will illuminate if a plant emergency occurs A light emitting diode indicating vacuum normal shall illuminate to indicate the vacuum state is normal. For duplex AGSS plant a push button selector will select the duty pump by pressing the appropriate push button. A light emitting diode will indicate which pump has been selected. A light emitting diode will illuminate if a fault occurs with the duty pump. Volt free contacts are available for remote status indication to BMS alarm Installation

AGSS plant shall be floor mounted in a adequately ventilated area at least 250 away from any wall to ease any further maintenance. Avoid obstructing the flow of cooling air to the fan end of the motor. The equipment should not be operated in ambient temperatures exceeding 40 C. The AGSS plant requires a 3 phase supply. This should be supplied via a local distribution board and be suitable for the rating of the pump. It is advisable to keep pipe runs as short as possible avoiding unnecessary pipe fittings. Where long or tortuous pipe runs are unavoidable, consideration should be given to increasing the pipe diameters. Mechanical Secure the base plate to the floor using suitable fixings. The mounting plate holes provided in the base are Ø12. Where possible mount the AGSS plant on a plinth. Connect the inlet pipework and exhaust pipework to the connections provided. Exhausts should be run as directly as possible to atmosphere and terminate in an elbow pointing downwards to protect against the ingress of water. Avoid air intakes for air conditioning, ventilation systems and windows. Check the condensate drain flasks are fitted. Electrical A Suitably sized wall mounted isolator and fuses should be supplied by the electrical contractor local to the pump. Connect the electrical power supply from the wall mounted isolator onto the bus-bar. (3 phase only) Neutral connects to a black terminal din rail mounted in the AGSS plant control box. Connect the wiring for AGSS remote switch(es) into the terminal block located in the AGSS plant control box Connect the wiring to the terminal blocks provided on the AGSS and fit the facia. Where the installation requires multiple AGSS remote switches these shall be daisy chained. Pipeline Jointing The AGSS plant copper stub pipe is manufactured to BS13348 for connection to the pipeline system and joints shall be made on site using copper, phosphorus and silver brazing alloy CuP282 to BS EN 17672:2010. Brazing should be carried out using oxygen free nitrogen as an inert gas shield to prevent the formation of oxides on the inside of the pipe. Copper pipes shall be cut square with the pipe axis using a sharp wheel cutter wherever possible, and be cleaned to get rid of any cuttings or burrs. Quality Pressure reducing stations are manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. All AGSS Plant is manufactured under strict quality control procedures to ISO 9001:2008.

Duplex Plant Layout Plant Sizes Simplex AGSS Plant Product Code: Plant size Dim A Dim B Dim C Outlet qty kw type Run Fuse Noise Weight AGSS-S-130 130 l/min 900 1 Db AGSS-S-260 260 l/min 900 2 Db AGSS-S-390 390 l/min 500 3 D.O.L 11.16 1.86 6 35 kg AGSS-S-520 520 l/min 500 4 D.O.L. 11.16 1.86 6 35 kg AGSS-S-1050 1050 l/min 550 8 1.1 D.O.L. 24 4 10 70 50 kg AGSS-S-1500 1500l/min 550 12 1.1 D.O.L 24 4 10 70 50kg AGSS-S-2500 2500 l/min 550 16 2.2 D.O.L. 33 5.5 10 72 65 kg

Duplex AGSS Plant Product Code: Plant size Dim A Dim B Dim C Outlet qty kw type Run Fuse Noise Weight AGSS-D-130 130 l/min 900 1 Db AGSS-D-260 260 l/min 900 2 Db AGSS-D-390 390 l/min 500 3 D.O.L 11.16 1.86 6 35 kg AGSS-D-520 520 l/min 1050 4 D.O.L. 11.16 1.86 6 90 kg AGSS-D-1050 1050 l/min 1100 8 1.1 D.O.L. 24 4 10 70 120 kg AGSS-D-1500 1500 l/min 1100 12 1.1 D.O.L 24 4 10 70 120 kg AGSS-D-2500 2500 l/min 1100 16 2.2 D.O.L. 33 5.5 10 72 150 kg Wiring Details

AGSS Remote Indicator It should fully comply with BS 5684, BS 6832 and HTM 2022, C11 standards. Control meet and

Connect the wiring for the AGSS Remote Switch(es) into the terminal block located in the AGSS Plant control box. Refer to the Remote switch connection diagram. Connect the wiring to the terminal blocks provided on the AGSS Remote Switch and fit the fascia. Where the installation requires multiple AGSS Remote Switches, these shall be Daisy chained.