Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Certificate of Accreditation

Laboratory Accreditation Programmes

Page 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

Accredited Laboratory

Certificate of Accreditation

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Certificate of Accreditation

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Certificate of Accreditation

Certificate of Accreditation

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

Date of Initial Accreditation Latest Date of Issue

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

CALIBRATION SYSTEM CERTIFICATE

Welcome to Garber C O R P O R AT E O V E R V I E W

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

Certificate of Accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

ANAUM INTERNATIONAL ELECTRONICS LLC. Test and Measurement Calibration Services Test Bench.

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELECTRICAL

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

ASC300. Advanced Signal Calibrator. Process signal calibrator with superior accuracy. Specification Sheet

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone:

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

TEST AND CALIBRATION SERVICES Ensuring quality and reliability.

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

We are engaged in manufacturing, supplying and trading Testing & Measuring Instruments (Electrical, Control & Instrumentation) Work Benches,

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Prüffeld der Schaltwerke

CALIBRATION CERTIFICATES

Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT

PTC8001 Temperature Calibrator

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

Schedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch

REQUEST FOR QUOTATION

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Rev /07/2015 CATALOGUE - CALIBRATION SERVICES 1

User s Guide WTM Laboratory Grade, Bench Top Mini Wind Tunnel. Shop online at omega.com

Certificate of Accreditation

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

2271A Industrial Pressure Calibrator Extended specifications

HPC600. Handheld Pressure Calibrator. Built-in electric pump. pressure

RTD CALIBRATOR Mode KM-CAL-720

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ISOCAL - 6 Range Europa Venus Calisto

Certificate of Accreditation

Certificate of Accreditation

UNIVERSAL CALIBRATOR M

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Spring loaded resistance thermometer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTONEUM NORTH AMERICA, INC Haggerty Rd. Novi, MI Jian Pan Phone: MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ZF GLOBAL ELECTRONICS- VALIDATION LABORATORY Carl-Spaeter-Str. 8 Koblenz, Germany 56070

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

photodiodes Description PerkinElmer Optoelectronics offers a broad array of Silicon and InGaAs PIN and APDs.

ANEMOMETER Vaisala WAA252

Transcription:

This is to attest that PROMPT ENGINEERING P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements of AC204, IAS Accreditation Criteria for Calibration Laboratories, and has demonstrated compliance with the ISO/IEC Standard 17025:2005, General requirements for the competence of testing and calibration laboratories. This organization is accredited to provide the services specified in the scope of accreditation maintained on the IAS website (www.iasonline.org). This certificate is valid up to January 1, 2021. (See laboratory s scope of accreditation for fields of calibration and accredited calibration.) This accreditation certificate supersedes any IAS accreditation bearing an earlier effective date. The certificate becomes invalid upon suspension, cancellation or revocation of accreditation. See www.iasonline.org for current accreditation information, or contact IAS at 562-364-8201. C.P. Ramani, P.E., C.B.O President

IAS Accreditation Number CL-165 Company Name Prompt Engineering & Trading Services Co. W.L.L. Address P.O. Box 24067, Barwa Village, Wakra, Building No. 6, Shop No. 19 And 20, Doha, Qatar Contact Name Bibin Philip Quality / Technical Manager Telephone +974-44418757 Effective Date of Scope April 18, 2017 Accreditation Standard ISO/IEC 17025:2005 CALIBRATION TECHNIQUE, REFERENCE STANDARD, External Micrometer Caliper (Vernier/Dial/ Electronics) Dimensional 0 mm to 150 mm/ 0.01 mm 6.0 µm 0 mm to 150 mm/ 0.001 mm 1.9 µm 0 mm to 300 mm/ 0.01 mm 9.0 µm 0 mm to 300 mm/ 0.02 mm 17.8 µm Using slip gauge set Grade 0, optical parallel and optical flat 0 mm to 600 mm/ 0.01 mm 11.0 µm Using surface plate, Height Gauge Grade 0 slip gauge set 0 mm to 600 mm/ 0.02 mm 15.0 µm and length bars Thickness Gauge 0 mm to 5 mm/ 0.001 mm 1.0 µm Using Slip gauge set 0 mm to 25 mm/ 0.01 mm 5.9 µm Grade 0 0 mm to 50 mm/ 0.01 mm 6.0 µm Feeler Gauge 0.01 mm to 2 mm 2.7 µm Using Digital Micrometer Standard Foils 0 m to 5000 m 2.6 µm Using Digital Micrometer Mechanical (Pneumatic) and Vacuum Gauge (Dial/Digital) and Recorder/ Transducer/ Safety Valve / Vacuum Gauge (Dial/Digital) and Recorder/ Transducer/ Safety Valve (Hydraulic) Gauge (Dial/Digital) and Recorder -0.85 bar to 0 bar/ 0.01 bar 1.47% FS 0 bar to 120 bar/ 0.01 bar 0.57% FS 0 bar to 200 bar/ 0.01 bar 0.57% FS 0 bar to 700 bar/ 0.01 bar 0.030% FS 700 bar to 1200 bar/ 0.1 bar 0.39% FS Using DH Budenberg P542 pneumatic calibrator (N 2 gas), FLUKE 719 Pro Cal Fluke P5513-20M Comparator with Reference pressure gauge, Fluke 2700G G20M Using DH Budenberg H542/409 hydraulic Deadweight Tester Page 1 of 8

Transducer Vibration Vibration Meter/Analyzer Acoustic At Laboratory Sound Level Meter Sound Level Calibrator Velocity At Laboratory Hot Wire, Vane Type and Pitot Tube Anemometer Recorder/ with Sensor/ Thermometer/Th ermocouple/rtd Sensor/ Gauge/ Transmitter Infrared Thermometer Oven/Incubator/ Freezer DC Current 10 m/s 2 0.38 m/s 2 Using Calibration exciter Type 4294, Bruel and Kjaer Make 94 db and 104 db @ 1 khz/ 1 db 94 db and 114 db @ 1 khz/ 0.1 db 2.5 m/s to 15 m/s/ 0.1 m/s 30 C to 660 C/ 0.001 C Thermal 1.7 db 1.4 db Using Vane anemometer: 0.55 m/s @ 15 m/s Using Pitot: 0.47 m/s @ 15 m/s 0.25 C Using Cirrus research CR511F and CR514 acoustic calibrator Using Cirrus CR162c sound level meter Using WTM 1000, Laboratory grade, Bench top mini wind tunnel, Omega make and reference anemometer and reference pitot tube Using FLUKE 9144 Dry Block Metrology Well, Fluke 7103 Micro Bath with Fluke 5628 PRT Secondary Standard -15 C to 120 C/ 0.01 C 0.7 C Using FLUKE 4180 IR 50 C to 500 C / 0.1 C 1 C calibrator, Fluke 9132 IR Calibrator Using FLUKE 9142 195 C to 419 C/ 0.001 C 0.63 C temperature calibrator with FLUKE 5615 PRT secondary standard Electrical/DC/Low Frequency 0 µa to 329.999 µa/1 na 0.04% RDG 0 ma to 3.29999 ma/ 0.01 µa 0.02% RDG Using FLUKE 5522 A, 0 ma to 32.9999 ma/ 0.1 µa 0.06% RDG multifunction calibrator 0 ma to 329.999 ma/ 0.02% RDG 1 µa 0 A to 1.09999 A/ 10 µa 0.06% RDG 1.1 A to 2.99999 A/ 10 µa 0.11% RDG 0 A to 10.9999 A/ 100 µa 0.08% RDG 11 A to 20.5 A/ 100 µa 0.08% RDG Using 50 Turn current coil Page 2 of 8

AC Voltage AC Current DC Voltage Resistance (2 wire and 4 wire) Resistance (2 wire and 4 wire) 300 A to 1000 A/ 1 A 0.5% RDG 1.0 mv to 32.99 mv @ 10 Hz to 500 Hz/ 1 µv 0.14% RDG 33 mv to 329.999 mv @ 10 Hz to 500 khz/ 1 µv 0.1% RDG 0.33 V to 3.29999 V @ 10 Hz to 500 khz/10 µv 0.08% RDG 3.3 V to 32.9999 V @ 10 Hz to 100 khz/ 100 µv 0.08% RDG 33 V to 329.999 V @ 45 Hz to 100 khz/ 1 mv 0.08% RDG 330 V to 1020 V @ 45 Hz to 10 khz/ 10 mv 0.063% RDG 0.029 ma to 0.32999 ma/ 0.01 µa 0.09% RDG 0.33 ma to 3.29999 ma/ 0.01 µa 0.110% RDG 3.3 ma to 32.9999 ma/ 0.1 µa 0.27% RDG 33 ma to 329.999 ma/ 1 µa 0.06% RDG 0.33 A to 2.99999 A/ 10 µa 0.08% RDG 3 A to 20.5 A/ 100 µa 0.19% RDG 300 A to 1000 A/ 1 A 1.3% RDG 0 mv to 329.9999 mv/ 0.1 µv 0.1% RDG 0 V to 3.299999 V/ 1 µv 0.06% RDG 0 V to 32.99999 V/ 10 µv 0.06% RDG 30 V to 329.9999 V/ 100 µv 0.015% RDG 100 V to 1020.000 V/ 1000 µv 0.015% RDG 0 to 10.9999 / 0.0001 2.0% RDG 11 to 32.9999 / 0.0001 2.0% RDG 33 to 109.9999 / 0.0001 2.0% RDG 110 to 329.9999 / 0.0001 2.0% RDG 330 k to 1.099999 k / 0.001 2.0% RDG 1.1 k to 3.299999 k / 0.001 2.0% RDG 3.3 k to 10.99999 k / 0.01 2.0% 11 k to 32.99999 k / 0.01 2.0% 33 k to 2.0% RDG Multifunction Calibrator Direct Method Using FLUKE 9100 and 5522A multifunction calibrator Using 50 Turn current coil Using FLUKE 5522 A Page 3 of 8

Frequency Capacitance Simulation indicator/ / Kit/ Universal 109.9999 k / 0.1 110 k to 329.99999 k / 0.1 2.0% 330 k to 1.099999 M / 1 2.4% RDG 1.1 M to 3.299999 M / 1 2.4% RDG 3.3 M to 10.99999 M / 10 3.9% RDG 11 M to 32.99999 M / 10 3.9% RDG 33 M to 109.9999 M / 100 3.9% RDG 110 M to 329.9999 M / 1000 3.9% RDG 330 M to 1100 M / 1000 3.9% RDG 0.01 Hz to 119.99 Hz/ 0.01 Hz 0.01% RDG 120.0 Hz to 1199.9 Hz/ 0.1 Hz 0.011% RDG 1.200 khz to 11.999 khz/ 1.0 Hz 0.29% RDG 12.00 khz to 119.99 khz/ 10 Hz 0.29% RDG 120.0 khz to 1199.9 khz/ 100 Hz 0.12% RDG 1.200 MHz to 2.000 MHz/ 1 khz 0.12% RDG 220 pf to 399.9 pf/ 0.1 pf 0.6% RDG 0.4 nf to 1.0999 nf/ 0.1 pf 0.6% RDG 1.1 nf to 3.2999 nf/ 0.1 pf 0.6% RDG 3.3 nf to 10.9999 nf/ 0.1 pf 0.6% RDG 11 nf to 32.9999 nf/ 0.1 pf 0.6% RDG 33 nf to 109.999 nf/ 1 pf 0.6% RDG 110 nf to 329.999 nf/ 1 pf 0.6% RDG 0.33 µf to 1.09999 µf/ 10 pf 0.6% RDG 1.1 µf to 3.29999 µf/ 10 pf 0.6% RDG 3.3 µf to 10.9999 µf/ 100 pf 3.1% RDG 11 µf to 32.9999 µf/ 100 pf 3.1% RDG 33 µf to 109.999 µf/ 1 nf 3.1% RDG 110 µf to 329.999 µf/ 1 nf 3.1% RDG 0.33 mf to 1.09999 mf/ 10 nf 3.1% RDG 200 o C to 800 o C, Pt 385, 100 / 0.003 C Pt 3926, 100 / 0.003 C Pt 3916, 100 / 0.003 C Pt 385, 200 / 0.003 C Page 4 of 8

Simulation indicator/ / (continued) DC Voltage Measure AC Voltage Measure @ 50 Hz DC Current Measure Pt 385, 500 / 0.003 C Pt 385, 1000 / 0.003 C -80 o C to 260 o C, Pt Ni 385, 120 (Ni120)/ 0.003 C -100 o C to 260 o C, Cu 427, 10 [3]/ 0.003 C 600 o C to 1820 C, B Type/ 0.01 C 0 o C to 2316 C, C Type/ 0.01 C 250 o C to 1000 C, E Type/ 0.01 C 210 o C to 1200 C, J Type/ 0.01 C 250 o C to 1372 C, K Type/ 0.01 C 200 o C to 900 C, L Type/ 0.01 C 200 o C to 1300 C, N Type/ 0.01 C 0 o C to 1767 C, R Type/ 0.01 C 0 o C to 1767 C, S Type/ 0.01 C 250 o C to 400 C, T Type/ 0.01 C 200 o C to 600 C, U Type/ 0.01 C 100 mv/100 nv 0.006% RDG 1 V/ 1 µv 0.006% RDG 10 V/ 10 µv 0.006% RDG 100 V/100 µv 0.006% RDG Using FLUKE 9100 and 5522A multifunction calibrator 1000 V/ 1 mv 0.02% RDG 100 mv/ 100 nv 0.11% RDG 1 V/ 1 µv 0.11% RDG 10 V/ 10 µv 0.33% RDG 100 V/ 100 µv 0.33% RDG 1000 V/ 1 mv 0.33% RDG 100 µa/ 100 pa 0.35% RDG 1 ma/ 1 na 0.35% RDG 10 ma/ 10 na 0.35% RDG Page 5 of 8

AC Current Measure @ 50 Hz Resistance Measure Frequency Measure (RTD Pt 100) Capacitance 100 ma/ 100 na 0.064% RDG 1 A/ 1 µa 0.08% RDG 3 A/ 10 µa 0.18% RDG 10 A/ 10 µa 0.18% RDG 100 µa/ 100 pa 0.42% RDG 1 ma/ 1 na 0.42% RDG 10 ma/10 na 0.42% RDG 100 ma/ 100 na 0.42% RDG 1 A/ 1 µa 0.16% RDG 3 A/ 10 µa 0.29% RDG 10 A/ 10 µa 0.29% RDG 10 / 10 µ 0.36% RDG 100 / 100 µ 0.023% RDG 1 k / 1 m 0.023% RDG 10 k / 10 m 0.073% RDG 100 k / 100 m 0.073% RDG 1 M / 1 0.073% RDG 10 M / 10 0.073% RDG 100 M / 100 1.37% RDG 1.0 G / 1 k 1.37% RDG 5 Hz to 1 MHz 0.12% RDG 200 C to 600 C 0.26 C 1 nf to 1 F 1.8% RDG 1 F to 100 mf 1.8% RDG 200 o C to 800 o C, Pt 385, 100 / 0.003 C Using FLUKE and 5522A Pt 3926, 100 / 0.003 C Measure Mode Pt 3916,100 / 0.003 C Pt 385, 200 / 0.003 C Pt 385, 500 / 0.003 C Pt 385, 1000 / 0.003 C -80 o C to 260 o C, Pt Ni 385, 120 (Ni120) / 0.003 C -100 o C to 260 o C, Using FLUKE and 5522A Measure Mode Page 6 of 8

Cu 427, 10 [3]/ 0.003 C 600 o C to 1820 C, B Type/ 0.01 C 0 o C to 2316 C, C Type/ 0.01 C 250 C to 1000 C, E Type/ 0.01 C 210 C to 1200 C, J Type/ 0.01 C 250 C to 1372 C, K Type/ 0.01 C 200 C to 900 C, L Type/ 0.01 C 200 C to 1300 C, N Type/ 0.01 C 0 C to 1767 C, R Type/ 0.01 C 0 C to 1767 C, S Type/ 0.01 C 250 C to 400 C, T Type/ 0.01 C 200 C to 600 C, U Type/ 0.01 C -200 C to 630 C, Pt 385, 500 / 0.003 C -200 C to 630 C, Pt 385, 1000 / 0.003 C -80 C to 260 C, PtNi 385, 120 (Ni120)/ 0.003 C -100 C to 260 C, Cu 427, 10 [3]/ 0.003 C 600 C to 1820 C, B Type/ 0.01 C 0 C to 2316 C, C Type/ 0.01 C 250 C to 1000 C, E Type/ 0.01 C 210 C to 1200 C, J Type/ 0.01 C 250 C to 1372 C, K Type/ 0.01 C 200 C to 900 C, L Type/ 0.01 C Using FLUKE and 5522A Measure Mode Page 7 of 8

200 C to 1300 C, N Type/ 0.01 C 0 C to 1767 C, R Type/ 0.01 C 0 C to 1767 C, S Type/ 0.01 C 250 C to 400 C, T Type/ 0.01 C 200 C to 600 C, U Type/ 0.01 C Using FLUKE and 5522A Measure Mode 1 Calibration and Measurement Capability is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation (at a confidence level of 95% with a coverage factor of 2) Page 8 of 8