Company Standard Mounting Instructions for Type Valves with Type AT Actuator

Similar documents
Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Mounting and operating instructions EB Pneumatic Control Valve Type and Type Globe Valve Type 3522 ANSI Class 300

Declaration of Conformity as per Directive 97/23/EC

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Valve Series V2001 Three-way Valve Type 3323

These installation and maintenance instructions must be read in full and completely understood before the installation!

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Data Sheet Rotary Plug Valve Type 72.3

VETEC Maxifluss Rotary Plug Valve Type 62.7

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Mounting and Operating Instructions EB 8256 EN. Type 3286 Steam Conditioning Valve

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Data Sheet Rotary Plug Valve Type 82.7

Instructions for installation, operation and maintenance of: GATE VALVE

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Operating and installation instructions

Series 250 Pneumatic Control Valves Type and

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Data Sheet Rotary Plug Valve Type 62.7

Operating manual Separator

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Pressure relief controller V22 D28

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Mounting and Operating Instructions EB 8052 EN. Type 3251 Valve

Operating & Maintenance Manual For Steam Conditioning Valve

Maxifluss Rotary Plug Valve. VETEC Type Double eccentric control valve for process engineering and industrial applications

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

GL Ludemann Y-Strainers

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Maxifluss Rotary Plug Valve VETEC Type 73.3

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

Operating Instructions

Operating manual Vacuum Breaker

Maxifluss Rotary Plug Valves VETEC Types 73.3/M and 73.7/M

A408 GB. Pneumatic oil and diesel pumps 1:1

Baumann Series Flexsleev Control Valve Instructions

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Mounting and Operating Instructions EB 8252 EN. Type 3281 Steam Conditioning Valve

Installation and operating manual

Triple Eccentric Control and Shut-off Butterfly Valve Series 14t

Baumann Mikroseal Control Valve

Model DF233 Control Valve

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Maxifluss Rotary Globe Valves VETEC Type 82.7

Maxifluss Rotary Plug Valve. VETEC Type 72.1/R, Type 72.3/R and Type 72.4/R

Operating and installation instructions

Series 14b - Type HD

FIVC. Static Balancing Valve. Technical data. Dimensions

Model DF269 Control Valve

Fisher 3024C Diaphragm Actuator

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Danfoss Butterfly Valve

VERSAFLOW MAG 4000 Quick Start

Maxifluss Rotary Plug Valve. VETEC Type Double eccentric control valve for process engineering and industrial applications

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

with pneumatic actuator Pneumatic process valve, Y-pattern DN ARI-STEVI AS 350 Pneumatic actuator - with screwed sockets

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

OPTIFLUX 2000 Quick Start

GENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure

Baumann Way Control Valve

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Maxifluss Rotary Plug Valve. VETEC Type Double eccentric control valve for process engineering and industrial applications

BR 14b / BR 14c Application:

Valve Technology DIN EN Butterfly Valves

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

BR 31a Rack-and-pinion Actuator,

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

J Flow Controls Model Numbering

VAG RIKO Plunger Valve

Pressure relief valve

Condensate Drain Valve AK 45. Original Installation Instructions English

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

Fisher 2052 Diaphragm Rotary Actuator

WATERFLUX 3070 Quick Start

Transcription:

Mounting Instructions for Type 72 82-62 Valves with Type AT Actuator Introduction These installation instructions contain important information on the installation, functioning, maintenance and storage of VETEC valves. The control valves are supplied according to customer specification, complete with actuator and accessories. The valves comply with the European Pressure Equipment Directive 97/23/EC. General safety instructions The control valves are to be mounted, started up or serviced by fully trained and qualified personnel only; the accepted industry codes and practices are to be observed. Make sure employees or third persons are not exposed to any danger. The safety regulations relevant to the plant (e.g. explosion protection, ATEX, corrosive/dangerous media etc.) as well as the accepted industry codes and practices are to be observed during installation, operation and maintenance. The manufacturer does not assume any responsibility for damage caused by external forces or any other external influence. Any hazards that could be caused by the operating and ambient conditions or by moving parts are to be prevented by means of the appropriate measures. External fires are to be prevented by means of the appropriate measures by the operator. Valves with hot, touchable surfaces are to be protected according to DIN EN 563 to prevent burn injuries. Proper shipping and storage of the control valves in accordance with the relevant regulations are assumed. For weights refer to the delivery notes. When using manual gears (handwheels) on the actuator, observe the operating instructions to prevent the valve and actuator from being damaged. Intended use VETEC control valves are sized individually according to the specific operating conditions provided by the customer, such as process medium, operating pressure and operating temperature. The limits of application for DVGW valves concerning the process medium, operating pressure, operating temperature and supply pressure are given on the nameplate. Make sure the valves are used as intended. If the valves are to be used under deviating operating conditions, contact VETEC Ventiltechnik GmbH to make sure that the valves are suitable for the requirements. Failure to check the valves' suitability for deviating conditions can lead to malfunctions and pose a considerable danger to persons, goods and the environment. Assembly and disassembly Install the control valves into the pipeline and connect them to the lines for the air supply and control signal observing the accepted industry codes and practices. For installing the valve into the pipeline we recommend a minimal distance of 6 nominal valve size (6x DN) in front of the valve and 6 nominal valve size (6x DN) behind the valve. An insufficient cross-section of the supply air line or an insufficient supply pressure impair the valves' control response or proper functioning. An excessive supply pressure can damage the actuator and accessories. Shut off, drain and vent the respective pipe section according to the operator's instructions before installing or removing the valves. Pressure-test the pipeline before installing the valves. (ersetzt die BN004.232) Revision: 05/10.03.2015 fth Page 1 of 10 Created by: Peter Konzack Approved by: H. Hock Date: 2005-04-12 Date: 2005-04-12

Make sure the pipeline is free of any residue (e.g. weld spatter, metal chips, tools etc.). Remove any foreign particles. Make sure the valves are mounted free of stress and not exposed to excessive vibration. If the actuators require support in the pipeline, observe the permissible locations. The permissible locations and weights for support are detailed in the VETEC regulations. Do not use the piping and control equipment as support or to suspend valves during transport; do not step on the piping and control equipment to prevent damage. Subject all valves taken from stock to safety, functional and leak tests before use. Failure to follow the instructions properly can lead to malfunctions and pose a considerable danger to persons, goods and the environment. Operation The control valves, as parts of the plant, are to be operated according to the operator's instructions and regulations. Unstable control causes increased wear. Contaminated supply air (e.g. with oil, water, dirt) or auxiliary energy and signals not according to specifications can cause the accessories or the entire control valve to malfunction or fail. Protect the valves against impermissible internal or external stress during operation. The operator must make sure that the valves' permissible pressure and temperature limits are not exceeded due to a thermal expansion of the process medium. Wear and corrosion may make it necessary to check the wall thickness of the valve bodies at regular intervals. The minimum required wall thickness is calculated and specified by VETEC. Service and maintenance The valves do not require maintenance. However, they are subject to natural wear, whose extent depends on the operating conditions. Wear can be identified by an impaired shut-off, increased external leakage, deteriorating control quality or unusual noise emissions. When repairing or replacing parts subject to wear on disassembled valves in the workshop, proceed as described in the mounting and operating instructions. Only use original spare parts by VETEC Ventiltechnik GmbH. As the valves may contain residue of the process medium, we recommend to remove the valves from the pipeline observing the medium-specific safety instructions. Depending on the field of application, allow the valves to cool down or heat up to reach ambient temperature before starting any work on them. Before starting any work on the valves or actuators, shut off the pneumatic and electric supplies to prevent any hazards caused by moving parts of the valves or actuators. In particular, make sure that the actuator springs remain compressed even after the actuators have been vented and the supply has been shut off. This is particularly important to remember when removing the actuators from the valves or when opening the actuators. When changing or retrofitting packing systems, e.g. according to TA-Luft, observe the VETEC mounting instructions. When mounting pressure-bearing parts on the valves, observe the tightening torques for bolts and screw connections specified in the maintenance instructions. Marking The valves have a nameplate. The nameplate is attached to the actuator or, for deliveries without actuator, to the valve's connecting flange. Conformity with the European Pressure Equipment Directive 97/23/EC is documented by the CE marking on the nameplates. Exception: valves according to 97/23/EC, Article 3, Paragraph 3 (good engineering practice). The valve and actuator types, nominal size, nominal pressure, serial number, order number etc. are specified on the nameplate. Revision:5 Page 2 of 10

Description of the nameplate 1 Ventil Typ / valve type 12 Schallmaßnahme, falls vorhanden / noise reduction if applicable 2 Ventil Serien-Nr. / valve serial no. 13 Entfällt / n.a. 3 Baujahr/year of manufacture 14 Entfällt / n.a. 4 Nennweite / nominal size 15 Sicherheitsstellung bei Hilfsenergie Ausfall / fail safe position without power supply 5 Nenndruck / nominal pressure 16 CE-Kennzeichen / CE mark 6 Gehäusewerkstoff / body material 17 VETEC Auftragsnummer / VETEC order no. 7 Werkstoff Sitz / seat material 18 Auftragspositionsnummer / order pos. no. 8 Werkstoff Sitz-Dichtkante / seat facing material 19 MSR Nr. / Tag No. 9 Kvs-Wert / kvs value 20 Seriennr. Antrieb / serial no. actuator 10 Cvs-Wert / cvs value 21 Antriebstyp / actuator type 11 Armaturen-Kennlinie / valve flow characteristic 22 Packungsausführung / packing 23 Max. zul. Zuluftdruck des Stellantriebes/ max. air supply The serial number is stamped onto the flange for future inquiries and spare part orders. Serien-Nr. auf dem Montageflansch Installation into the pipeline Mount the valve into the pipeline with the arrow on the body pointing in flow direction. Make sure the valve inlet is equipped with a filter or strainer if the absolute cleanness of the process medium is not ensured otherwise (e.g. central filtering unit) Durchflußrichtung Revision:5 Page 3 of 10

Mounting position of the actuator The actuator must be installed in the specified positions. Other mounting positions must be approved by VETEC before installation. Mounting type A Mounting type B FTC (spring closes, air opens) FTO (spring opens, air closes) FTC (spring closes, air opens) FTO (spring opens, air closes) Mounting type C Mounting type D FTC (spring closes, air opens) FTO (spring opens, air closes) FTC (spring closes, air opens) FTO (spring opens, air closes) Transport for mounting Use only the predefined locations to suspend the control valves during transport. When damaged, it can no longer be guaranteed that the valve moves to its fail-safe position (transit time). Use only the predefined locations to suspend the control valves during transport. Control lines, accessories as well as other components with fail-safe function must not be used as suspensions for transport. Accessories and control line As DVGW valves are safety valves, all control lines, accessories and components for fail-safe function must be protected against improper use. When damaged, it can no longer be guaranteed that the valve moves to its fail-safe position (transit time). Any structural changes to the DVGW valves delivered by VETEC must be performed by trained personnel. F F Make sure no improper forces act on the control line or accessories. Do not store the valve on the control line since this can cause damage. F F Do not step on the control line or accessories and do not damage them with tools. Revision:5 Page 4 of 10

Insulating the pipeline and control valve Insulate the valve so that neither the fail-safe action nor the proper functioning are impaired. Insulating valves with TA-Luft packing Make sure no excessive temperatures or heat accumulation occur at the packing or seal. The recommended values given in the table are to be observed. Valves with TA-Luft packing are marked specially. Typenschild TA-Luft Schild Isolierung Valve size Distance M in mm 25 50 40 60 50 60 80 60 100 60 150 100 200 100 Starting up valves with longer heating-up time For valves in sizes DN 200 or larger and for operating temperatures above 200 C, expansion of the components due to heat cannot be avoided. Since the components are made of different materials, the degree and direction of heat-induced expansion, due to the design, are not exactly defined. The plug may expand due to heat exposure. Kegel kann sich durch Wärmezufuhr aus dehnen. During the heating-up period, the heat is distributed rather unevenly across the valve. The components expand differently. As a result, the plug can get jammed in the seat ring (see drawing).. 2 bis 3 As a result, open the valve slightly (angle of approx. 2 to 3 ) before start-up and close it again after start-up when the process medium has distributed the heat evenly (see drawing). The valve can be opened by the specified angle using the actuator or additionally mounted travel stops on the actuator. Revision:5 Page 5 of 10

Installing sandwich-style valves (Type 72.4) into the pipeline (without retaining ring) When using different thread versions, the bolt dimensions remain unchanged, only the thread version changes (e.g. ANSI - UNC). Connecting rod with 2 nuts each Bolts DN PN (DIN) Pcs. Dimensions Pcs. Dimensions 25 10 4 M12x180 25 16 4 M12x180 25 25 4 M12x180 25 40 4 M12x180 40 10 4 M16x200 40 16 4 M16x200 40 25 4 M16x200 40 40 4 M16x200 50 10 4 M16x210 50 16 4 M16x210 50 25 4 M16x210 50 40 4 M16x210 Valve sizes DN 25, DN 40, DN 50 Connecting rod with 2 nuts each Bolts DN PN (DIN) Pcs. Dimensions Pcs. Dimensions 80 10 6 M16x260 4 M16x35 80 16 6 M16x260 4 M16x35 80 25 6 M16x260 4 M16x40 80 40 6 M16x260 4 M16x40 Revision:5 Page 6 of 10

100 10 6 M16x285 4 M16x50 100 16 6 M16x285 4 M16x50 100 25 6 M20x300 4 M20x55 100 40 6 M20x300 4 M20x55 Valve sizes DN 80, DN 100 Connecting rod with 2 nuts each Bolts DN PN (DIN) Pcs. Dimensions Pcs. Dimensions 150 10 4 M20x330 8 M20x55 150 16 4 M20x330 8 M20x55 150 25 4 M24x350 8 M24x60 150 40 4 M24x350 8 M24x60 200 10 4 M20x350 8 M20x55 200 16 8 M20x350 8 M20x55 200 25 8 M24x370 8 M24x65 200 40 8 M27x385 8 M27x65 250 10 8 M20x410 8 M20x70 250 16 8 M24x420 8 M24x70 250 25 8 M27x440 8 M27x75 250 40 8 M30x460 8 M30x80 300 10 8 M20x450 8 M20x70 Revision:5 Page 7 of 10

300 16 8 M24x470 8 M24x70 300 25 12 M27x490 8 M27x75 300 40 12 M30x510 8 M30x85 Valve sizes DN 150, DN 200, DN 250, DN 300 Electrostatic discharge Electrostatic charging may occur on the valve bodies during operation in the plant, particularly on valves with insulation. As a result, include a ground connection as a safety measure. Caution! The threaded area must be free of paint. Ground connection Safety measure against electrostatic charging Valves with ceramic trims Valves with ceramic trims bear a special label.!!! NOTE!!! Caution Ceramic! Do not subject ceramic parts to sudden temperature increases or other thermal shocks. Strictly observe the thermal shock limits. Valves with retaining ring (Types 72.2, 72.6, 72.2P) must be open when installing them into the pipeline. Do not expose valves with ceramic trims and ceramic spare parts to sudden mechanical stress. Revision:5 Page 8 of 10

Haltering Haltering To ensure tight shut-off towards the atmosphere, cover the area between the armored bushing and the body with a sealing surface on both sides. DN Valve size A B Inside pipe dimensions acc. to Series 01 mm mm mm 25 64 28.5 40 82 43.1 50 100 54.5 80 132 82.5 100 162 107.1 150 217 159.3 200 272 206.5 250 326 258.8 300 377 307.9 B A Cleaning and rinsing pipelines before start-up While the pipeline is being rinsed, any residue from mounting (welding spatter, etc.) or from tools (wrench sockets, nuts, etc.) can damage the valve. Particularly, valves with soft-seated plugs, strainer inserts, filter inserts, noise-reducing trims, perforated plates must be removed from the pipeline and replaced by adapters before rinsing the pipeline. Valve with soft seat or plastic seat Noise-reducing trim Seat ring with perforated plate Perforated plate Revision:5 Page 9 of 10

Disassembling actuators, gears, bonnets, packing, nuts and bolts, stoppers or other pressure-bearing seal elements CAUTION! Do not remove the actuator from the valve while the valve is in operation in the pipeline/plant! CAUTION! Do not undo or remove external pressure-bearing components while the valve is in operation in the pipeline/plant! The lateral screw is not a port sniffer. It serves as a blow out for the shaft and therefore must not be removed during the operation in the pipeline or in the system. Revision:5 Page 10 of 10