The Measure of all Things. Volumetric Solutions from Merck

Similar documents
Titrette. class A precision. The next generation Digital Burette!

Titrette. class A precision. 10 ml. New. size. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette!

N E W! The next generation Digital Burette.

User Manual Electronic Titrator

Bright prospects Solvents for spectroscopy Uvasol

Liquid Handling Easy Handling! Titrette. Gebrauchsanleitung. Operating Manual. Mode d'emploi. Instrucciones de manejo

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

PROPOSED REVISION OF THE GENERAL CHAPTER 1.11 COLOUR OF LIQUIDS. for The International Pharmacopoeia

Water analysis, QC and more:

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

ASTM Methods that are feasible with Metrohm instruments

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors

Physical properties of PET resins. 1. Intrinsic Viscosity (IV)

Plastic bearings that revolve around your needs.

VentureClad Insulation Jacketing Tapes 1577 Series

TEST REPORT: CHM12-01-LSM

ISO 660 INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of acid value and acidity

Small on price, big on boot

Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.

Fibreglass Reinforced Plastic

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

New Pig One Pork Avenue Tipton, PA Chemical Compatibility Guide for: FTI Pumps

Plexo composable plate supports and boxes

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

Dynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.

BIODEGRADABILITY TESTING OF ONE PRODUCT

Metallic Systems TYPE SPTC

THREE RANGE DS METERS Operation Instructions

2014 FCA Canada Inc. Windsor Assembly Plant [ANNUAL PUBLIC REPORT UNDER O. REG. 455/09]

MM PISTON PUMP

Biodiesel Fundamentals for High School Chemistry Classes. Laboratory 7: Using Differences in Solubility to Remove Contaminants from Biodiesel

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

This convenient system is made entirely of inert parts: glass, Baseline drift

We offer two fire retardant (FR) resins for strut systems: polyester and vinyl ester. Both resins are ideal for corrosive environments.

Liquid Handling. iclab.com.au / iclab.co.nz

Competence in Labware. Liquid-Handling range

M1.(a) C 6 H [5] Page 2. PhysicsAndMathsTutor.com

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

CITY OF ALLIANCE, OHIO 2016 CHEMICAL SUPPLIES SPECIFICATIONS FOR

ASTM D Test to Low ppb. Contact us today for a copy of the Southwest Research Institute D-5453 Fitness for Use Report.

Excessive Waste. Some of the grease is used to supplement feed farms but majority of it ends up in landfills

Chemistry of Biodiesel: The beauty of Transesterfication

Ducting & Ventilation Components

PHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000

Competence in Labware. Liquid-Handling range

DURA SLAB PULTRUDED TECHNICAL SPECIFICATIONS January 2014

Dead Level. Pre-sloped Trench Drain System. Watts.com

MiniLab EL Series for High Performance Engine Development and Maintenance

Filtertechnik Filtration, Purification & Separation Solutions

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer

FRP RADIAL FUME EXHAUSTERS/ PRESSURE BLOWERS THE NEW YORK BLOWER COMPANY

TNI PT Frequency Subcommittee August 12, Total Number Not Acceptable. Total Number Data Points. Average Absolute z score.

Pharmaceuticals USP Quality Control Edition.

INVITATION FOR QUOTATION. TEQIP-III/2018/mmug/Shopping/29 To,

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Chemical Resistance of Arnitel

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

Swivel Joints Flexmaster Joints Part Number NH NH NH NH NH NK NK

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(10)-05 Issued July 2011

Catalog June Mounted Bearings

INTERPRETATION OF USED COOLANT ANALYSIS

For any application the right Dispensette. Dispensette III Dispensette Organic Dispensette HF

MM PISTON PUMP

MasterProtect 1870 / 1880

Measures against Incineration Problems Caused by Clogging of White Smoke Prevention Preheater

The Purification Feasibilityof GlycerinProduced During

MAN Diesel SEA-Mate Onboard Blending and Fluid Analysis Systems

NEW: RAUFILAM -E COLOUR ALWAYS THE RIGHT CHOICE. Industrial hoses, with and without fabric lining

Product: Isosorbide. Product: Isosorbide Flow Diagram

PRODUCT MANUAL FOR DISINFECTANT FLUID, PHENOLIC TYPE According to IS 1061: 2017

Hose and Fitting Edition

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

TANK LINING RESISTANCE GUIDE I-19

Instruction Manual BL1.5 BL3 BL5 BL7 BL10 BL15 BL20. Dosing Pumps.

4&5 RANGE CONDUCTIVITY METERS Operation Instructions

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(09)-05 Issued July 2010

IGS-M-CH-051-1(0) Jan مصوب. Approved IGS. Molecular Sieve, Type 3A

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

NO: AC.2006.CT.01 شرکت کامپوزیت آسیاآسیا(سهامی تولیدکننده انواع قطعات کامپوزیتی گریتینگ و سینی کابل)

P17 plugs, mobile sockets and surface-mounting sockets «New range 16 and 32 A»

The table below gives information about milk bottles. Raw materials Sand, limestone, salt Crude oil. Bottle material Soda-lime glass HD poly(ethene)

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

INTERNATIONAL STANDARD. Natura1 gas - Determination of Sulfur compounds - Part 5 : Lingener combustion method

ATTACHMENT FIVE. Universal Waste Packaging Guidelines

Movitec VCI Type Series Booklet

KLINGER KGS. Rubber-Metal-Gaskets Safe sealing of gases and liquids

When you need to be Sure, be Sure to be Ready! Warranty does not cover any shipping. Berm must be shipped back to factory prepaid.

CHEMICAL COMPOSITION OF WATER IN THE PUTAH CREEK BASIN. c. S. BISSON AND MARTIN R. HUBERTY

Material of construction. Inner shell material: Polyethylene. Available inlets: See chart. Operating parameters. Maximum operating pressure: 150 psi

HYPRA Prisinter 16/32/63 A

Agenda. DEF Presentation Turn-Key DEF Solutions. Q & A Wrap-up and Depart

KLINGER-KGS Rubber- Metal-Gasket

Louis Dreyfus Claypool Holdings, LLC. Biodiesel Production Plant Claypool, Indiana

High quality. Dosing pumps, BL series. Features

Transcription:

The Measure of all Things Volumetric Solutions from Merck

Titration is the oldest but still the most precise procedure in chemical analysis. However, such precise analyses require accurately adjusted volumetric solutions. Depending on the analytical problem on hand, acids, bases, reducing and oxidizing substances as well as complex formers are used in both aqueous and non-aqueous solutions. Regardless of the type of problem you have to tackle, you will find the right volumetric solution in the Merck product range. http://titripac.merck.de

Typical for Merck: Quality control throughout the entire production chain Volumetric solutions are produced at Merck under the most stringent of control conditions. These include temperature control, defined and constantly monitored titration units as well as standardized procedures in the quality control itself. In this way we can guarantee that all volumetric solutions batch for batch are adjusted with a high degree of precision to an exact titer. Batch-specific Certificate of Analysis A Certificate of Analysis for each and every batch of volumetric solution can be called up via web site www.merck.de. The Certificate of Analysis documents the concentration of the substance in mol/l as well as the titer of the batch as measured at 20 C. It also contains information on the primary standards used during testing. These, of course, are traceable directly to Standard Reference Materials (SRM) of the National Institute of Standards and Technology (NIST), Gaithersburg, USA. In addition, the date of testing and the expiry date are indicated, including on the packaging. The titer indicated on the Certificate of Analysis applies to the original closed package and is valid in this condition throughout the entire shelf life of the product. The stability of the solution subsequent to the package being opened is, however, dependent on the chemical properties of the volumetric solution. Solutions of substances such as iron(ii) salts that are known to be unstable or substances such as sodium hydroxide that absorb carbon dioxide should be recalibrated before use against a known volumetric standard. The concentration tolerance of most ready-to-use solutions is 0.1%; Titrisol concentrates have a maximum of 0.2 %. Reliable and documented quality

Flexible: Concentrates For those labs that have to cope with a variety of applications, we provide most volumetric solutions as Titrisol ampoules. Each ampoule contains a precisely defined amount of substance normally they are then diluted to 1 liter for use. Other concentrations can be obtained simply by diluting appropriately Reliable and precise: Ready-to-use solutions Most analytical labs now employ ready-to-use volumetric solutions. They have a maximum titer deviation of only 0.1 % and are thus highly precise. In addition, potential sources of error e.g. dilution with contaminated water or the use of non-calibrated volumetric flasks are excluded. Various package sizes are available for different applications. Titrisol ampoules Volumetric solutions that can be prepared rapidly and precisely Concentrations can be prepared as required Space-saving reservoir pack 5-year shelf-life guarantee PE bottles and canisters Packs suitable for laboratory use. Non-breakable bottles and canisters made of contamination-free polyethylene. Direct connection possible to all common titrators via the S40 adapter system.

Convenient: Large packs of stable titer For those labs that require larger quantities of volumetric solutions, the 4-liter and 10-liter Titripac pack is a practical and economic alternative. A closed system, it guarantees absolute stability of the concentration of substance from the first to the last drop. A suitable pack for every application Merck Titripac volumetric solutions of high quality in exclusive reservoir packs. Titripac Reliable closed system Sealed pack prevents atmospheric contamination Stable titer from the first to the last drop Integrated withdrawal tap for immediate use Liner and external carton can be easily separated for disposal Exclusively available from Merck Can be direct connected with the titrator No additional titer determinations No contaminated left overs

The measure of all things: Volumetric solutions from Merck

Ordering information for volumetric solutions Article Concentration Titrisol ampoules: Ready-to-use Titripac 4 l 1 l solution solution Titripac 10 l Cat. No. Cat. No. Cat. No. Acetic acid 0.1 mol/l (0.1 N) 1.09944.0001 1 mol/l (1 N) 1.09951.0001 1 mol/l (1 N) 25 l: 1.99061.9025 Ammonium cer(iv)nitrate solution 0.1 mol/l (0.1 N) 1 l: 1.02277.1000 Ammonium iron(ii)-sulfate solution 0.1 mol/l (0.1 N) 1.09864.0001 Ammonium thiocyanate solution 0.1 mol/l (0.1 N) 1.09900.0001 1 l: 1.09079.1000 Barium chloride solution 0.05 mol/l (0.1 N) 1.09962.0001 Barium perchlorate solution 0.005 mol/l 1 l: 1.09086.1000 in 2-propanol/water (80 : 20) Bromide-bromate solution 0.05 mol/l (0.1 N) 1.09905.0001 Cer(IV)sulfate solution 0.1 mol/l (0.1 N) 1 l: 1.09092.1000 Copper sulfate solution 0.1 mol/l 1 l: 1.02784.1000 Copper-di-ammonium 0.1 mol/l 0.5 l: 1.05217.0500 Titriplex solution Hanus solution 0.1 mol/l in acetic acid 1 l: 1.09164.1000 (iodomonobromide solution) Hyamine 1622 solution 0.004 mol/l 1 l: 1.15480.1000 for the determi nation of anionic tensides Hydrochloric acid 0.01 mol/l (0.01 N) 1.09974.0001 0.1 mol/l 1.09973.0001 1 l: 1.09060.1000 4 l: 1.09060.4000 5 l: 1.09060.5000 10 l: 1.09060.9010 25 l: 1.09060.9025 0.1 mol/l (0.1 N) 1 l: 1.00326.1000 in 2-propanol 0.357 mol/l (1/2.8 N) 10 l: 1.13136.9010 0.5 mol/l (0.5 N) 1.09971.0001 1 l: 1.09058.1000 4 l: 1.09058.4000 25 l: 1.09058.9025 1 mol/l (1 N) 1.09970.0001 1 l: 1.09057.1000 4 l: 1.09057.4000 2.5 l: 1.09057.2500 10 l: 1.09057.9010 5 l: 1.09057.5000 25 l : 1.09057.9025 2 mol/l (2 N) 1 l : 1.09063.1000 3.571 mol/l (1/0.28 N) 10 l: 1.13134.9010 5 mol/l (5 N) 1 l: 1.09911.0001 1 mol/l (1 N) 1.99070.9025 Iodide-iodate solution 1/128 mol/l I2 (1/64 N) 1.09914.0001 Iodine solution 0.05 mol/l (0.1 N) 1.09910.0001 1 l: 1.09099.1000 0.5 mol/l (1 N) 1 l: 1.09098.1000

Article Concentration Titrisol ampoules: Ready-to-use Titripac 10 l 1 l solution solution Cat. No. Cat. No. Cat. No. Mercury(II)nitrate solution 0.05 mol/l (0.1 N) 1 l: 1.09143.1000 Nitric acid 0.1 mol/l 1.09964.0001 1 mol/l (1 N) 1.09966.0001 10 mol/l (10 N) 1 l: 1.00630.1000 Oxalic acid solution 0.005 mol/l (0.01 N) 1.09932.0001 0.05 mol/l (0.1 N) 1.09965.0001 Perchloric acid 0.1 mol/l (0.1 N) 1 l: 1.09065.1000 in water-free acetic acid Potassium bromate solution 1/60 mol/l (0.1 N) 1.09925.0001 Potassium dichromate solution 1/60 mol/l (0.1 N) 1.09928.0001 1/24 mol/l (0.25 N) 1 l: 1.09118.1000 0.020 mol/l 1 l: 1.09119.1000 Potassium hydroxide solution 0.1 mol/l (0.1 N) 1.09921.0001 1 l: 1.09112.1000 0.1 mol/l (0.1 N) 1 l: 1.09115.1000 in ethanol 2.5 l: 1.09115.2500 0.1 mol/l (0.1 N) 2.5 l: 1.11587.2500 in methanol 0.1 mol/l (0.1 N) 1 l: 1.05544.1000 in 2-propanol 0.5 mol/l (0.5 N) 1.09919.0001 5 l: 1.11586.5000 0.5 mol/l (0.5 N) 1 l: 1.09114.1000 in ethanol 2.5 l : 1.09114.2500 0.5 mol/l (0.5 N) 1 l: 1.09351.1000 in methanol 1 mol/l (1 N) 1.09918.0001 1 l: 1.09108.1000 1 mol/l (1 N) 1 l: 1.09107.1000 max. 0.4 ppm Ca 2.0 mol/l (2 N) 2.5 l: 1.11787.2500 in methanol Potassium iodate solution 1/60 mol/l (0.1 N) 1.09917.0001

Article Concentration Titrisol ampoules: Ready-to-use Titripac 4 l 1 l solution solution Titripac 10 l Cat. No. Cat. No. Cat. No. Potassium permanganate solution 0.002 mol/l (0.01 N) 1.09930.0001 0.02 mol/l (0.1 N) 1.09935.0001 0.02 mol/l (0.1 N) 1 l: 1.09121.1000 standardized with sodium thiosulphate 0.02 mol/l (0.1 N) 1 l: 1.09122.1000 standardized with oxalate 0.05 mol/l (0.25 N) 2.5 l: 4.80160.2500 Silver nitrate solution 0.05 mol/l (0.05 N) 1 l: 1.11718.1000 0.1 mol/l (0.1 N) 1.09990.0001 1 l: 1.09081.1000 4 l: 1.09081.4000 2.5 l: 1.09081.2500 10 l: 1.09081.9010 1 mol/l (1 N) 1 l: 1.09080.1000 Sodium arsenite solution 0.05 mol/l (0.1 N) 1 l: 1.06277.1000 5 l: 1.06277.5000 Sodium carbonate solution 0.05 mol/l (0.1 N) 1.09940.0001 Sodium chloride solution 0.1 mol/l (0.1 N) 1.09945.0001 Sodium hydroxide solution 0.01 mol/l (0.01 N) 1.09961.0001 0.02 mol/l (0.02 N) 0.5 l: 1.09142.0500 0.1 mol/l (0.1 N) 1.09959.0001 1 l: 1.09141.1000 4 l: 1.09141.4000 5 l: 1.09141.5000 10 l: 1.09141.9010 25 l: 1.09141.9025 0.111 mol/l (0.111 N) 25 l: 1.10822.9025 0.2 mol/l (0.2 N) 1 l: 1.09140.1000 4 l: 1.09140.4000 10 l: 1.09140.9010 0.25 mol/l (0.25 N) 1.09958.0001 1 l: 1.09139.1000 10 l: 1.09139.9010 0.33 mol/l (0.33 N) 1 l: 1.05595.1000 10 l: 1.05595.9010 0.357 mol/l (1/2.8 N) 10 l: 1.05599.9010 0.5 mol/l (0.5 N) 1.09957.0001 1 l: 1.09138.1000 4 l: 1.09138.4000 10 l: 1.09138.9010 1 mol/l (1 N) 1.09956.0001 1 l: 1.09137.1000 4 l: 1.09137.4000 2.5 l: 1.09137.2500 10 l: 1.09137.9010 25 l: 1.09137.9025 1 mol/l (1 N) 25 l: 1.99060.9025 2 mol/l (2 N) 1 l: 1.09136.1000 25 l: 1.09136.9025 4 mol/l (4 N) 5 l: 1.11584.5000 5 mol/l (5 N) 1 l: 1.09913.0001 6 mol/l (1 N) 25 l: 1.99062.9025

Article Concentration Titrisol ampoules: Ready-to-use Titripac 4 l 1 l solution solution Titripac 10 l Cat. No. Cat. No. Cat. No. Sodium methylate solution 0.1 mol/l (0.1 N) 1 l: 1.11553.1000 Sodium thiosulfate solution 0.01 mol/l (0.01 N) 1.09909.0001 0.1 mol/l (0.1 N) 1.09950.0001 1 l: 1.09147.1000 4 l: 1.09147.4000 25 l: 1.09147.9025 10 l: 1.09147.9010 Sulfuric acid 0.005 mol/l (0.01 N) 1.09982.0001 0.05 mol/l (0.1 N) 1.09984.0001 1 l: 1.09074.1000 4 l: 1.09074.4000 5 l: 1.09074.5000 10 l: 1.09074.9010 0.25 mol/l (0.5 N) 1 l: 1.09073.1000 4 l: 1.09073.4000 10 l: 1.09073.9010 0.5 mol/l (1 N) 1.09981.0001 1 l: 1.09072.1000 4 l: 1.09072.4000 5 l: 1.09072.5000 10 l: 1.09072.9010 2.5 mol/l (5 N) 1 l: 1.09912.0001 Tetra-n-butyl- 0.1 mol/l (0.1 N) 0.5 l: 1.09162.0500 ammonium hydroxide solution in 2-propanol/ 1 l: 1.09162.1000 methanol Tetramethylammonium hydroxide 0.1 mol/l (0.1 N) 0.25 l: 1.08124.0250 solution in 2-propanol/methanol 1 l: 1.08124.1000 Titriplex III solution (Na2-EDTA) 0.01 mol/l 1.08446.0001 0.1 mol/l 1.09992.0001 1 l: 1.08431.1000 4 l: 1.08431.4000 10 l: 1.08431.9010 Titriplex IV solution (Na2-DCTA) 0.1 mol/l 1 l: 1.08447.1000 4 l: 1.08447.4000 Wijs solution 0.1 mol/l 1 l: 1.09163.1000 (iodomonochloride in acetic acid) 2.5 l: 1.09163.2500 23 l: 1.09163.9023 Zinc sulfate solution 0.1 mol/l 1.09991.0001 1 l: 1.08879.1000 Volumetric solution Article Concentration Ready-to-use solution Cat. No. Acetic acid 1 mol/l (1 N) 25 l: 1.99061.9025 Hydrochloric acid 1 mol/l (1 N) 25 l: 1.99070.9025 Sodium hydroxide solution 1 mol/l (1 N) 25 l: 1.99060.9025 6 mol/l (1 N) 25 l: 1.99062.9025 Further volumetric solutions material acc. Ph. Eur. on request.

CertiPUR secondary reference materials for volumetry Reliable reference materials for volumetric analysis Merck supplies additional reference materials for the adjustment and control of volumetric solutions. If reliable information on the titer of a volumetric solution is to be obtained, these substances must correspond absolutely to the composition designated by the chemical formula. Analysis Article Package size Cat. No. Acidimetry Sodium carbonate 80 g 1.02405.0080 Tris(hydroxymethyl)aminomethane 80 g 1.02408.0080 Alkalimetry Potassium hydrogen phthalate 80 g 1.02400.0080 Benzoic acid 60 g 1.02401.0060 Argentometry Sodium chloride 80 g 1.02406.0080 Complexometry Zinc 100 g 1.02409.0100 Calcium carbonate 50 g 1.02410.0050 Iodometry Potassium iodate 100 g 1.02404.0100 Redox titration Iron(II)ethylenediammonium sulfate 80 g 1.02402.0080 Potassium dichromate 80 g 1.02403.0080 Di-sodium oxalate 60 g 1.02407.0060 CertiPUR reference materials In order to provide the highest possible quality standard and precisely defined tolerances, Certipur reference materials are prepared under the most stringent of controls and measured with the highest possible degree of accuracy for the given applications. CertiPUR standard solutions are directly traceable to the standard reference materials provided by the National Institute of Standards and Technology (NIST), Gaithersburg, USA.

Merck KGaA Analytical Reagents 64271 Darmstadt, Germany Fax: +49-6151- 72 60 80 internet: www.merck-chemicals.com e-mail: reagents@merck.de W.281121 Release date: December 2007 We advise our customers on technological matters to the best of our knowledge under given circumstances. Our information and recommendations are provided without obligation or liability for us. Existing laws and regulations are to be observed in all cases by our customers. This also applies in respect to any rights of third parties. Our suggestions do not relieve our customers of their own responsibility of checking the suitability of our products for the envisaged purpose. Quotations from our literature are only permitted with our written authority, and the source must be stated.