FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Similar documents
AR circuit breaker - Hydraulic magnetic,

FR circuit breaker - hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic,

CR circuit breaker - hydraulic magnetic,

RBR circuit breaker - Remote operated

PDR circuit breaker - Ground fault Datasheet

F-Series. Circuit Breaker

F-Series. Circuit Breaker

N.S1-P relay - Signalling, post

AG 400 relay - Gold plated, 4 contacts

G-Series. Circuit Breaker.

Description The EA 112 socket has crimp contacts to allow rear connection on the socket.

PB-Series. GFCI/ELCI & Panel Seal

G-Series DIN-RAIL CIRCUIT BREAKER

J-Series CIRCUIT BREAKER

Renewable Energy. Circuit Breakers and Disconnects

L-Series. Circuit Breaker

PD-Series Ground Fault Circuit Protection

CX-Series. Circuit Breaker

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

MS-Series. Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DD Frame - Series Circuit Breakers

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Magnetic and Hydraulic-Magnetic Circuit Breaker

F-Series General Specifications

Magnetic Overcurrent Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

Energy and traction control solutions

Thermal Overcurrent Circuit Breaker 3120-F...

Carling Circuit Breakers

Electronic Circuit Breaker ESS20-0..

Products :: Circuit Protection :: Thermal Circuit Breakers

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal Overcurrent Circuit Breaker 3120-F...

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

Thermal Circuit Breaker 3120-F...

Series KTU7 UL489 Molded Case Circuit Breakers

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Electronic Circuit Breaker ESS20

Thermal Overcurrent Circuit Breaker 3120-F...

QF(13) - Series Miniature Circuit Breakers

QF(19) - Series Miniature Circuit Breakers

ID ID. Series 19. Mechanical Products Company

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-...

UMBW-UL489 and UL1077 Listed

209/219/229/249/279 Series Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors

Series KTU7 UL489 Molded Case Circuit Breakers

L Frame - Series Moulded Case Circuit Breakers

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Ordering Information. Text PCB Power Relay G5LE

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Catalog Issued 3-03 (PDF Rev )

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

Subminiature Basic Switch

700 Series Thermal Switch High Reliability

OTEC Transfer switch open transition

BD-SERIES. BD-Series BATTERY DISCONNECT POWER SWITCH. Resources: Product Highlights: Typical Applications:

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

H-Series. Circuit Breaker.

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Transfer switch OTEC open or delayed transition

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

BD-SERIES. BD-Series BATTERY DISCONNECT POWER SWITCH. Resources: Typical Applications: Product Highlights:

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

RX 3 M.C.B A up to 63 A

Circuit Breakers Circuit breakers are

SECTION PANELBOARDS

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

High Performance Thermal Circuit Breaker

Electronic circuit breaker EBU10-T

AP/UP, AP/MIL Series Magnetic Circuit Protectors

TMC 91H is now TMC 60 C Series

RX 3 M.C.B A up to 63 A

SAR & SAS Circuit Protectors

RESIDUAL CURRENT CIRCUIT BREAKER

Model Number Structure

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

IN2 Enclosed Switches and Circuit Breakers

Metrosil / Resistor Module Features Application Operation

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Electronic overload relays EF205 and EF370

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Thermal-Magnetic Circuit Breaker M1-..

Transcription:

FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary contacts (optional) Up to 3 poles configuration High interrupting capacities due to unique arc chute method Mid-trip handle for electrical trip indication (optional) Immediate resetting possible Wide current range: 100-700 A Wide choice of time delays Maximum voltage 137.5 VDC / 277 VAC High contact pressure & longer contact life due to wiping self-cleaning contacts Flexibility by many options Benefits Description Hydraulic magnetic circuit breaker for very high current railway applications to protect electronic equipment and components against unintended high currents. Optional with integrated auxiliary contacts to monitor the circuit. The trip point is always at maximum allowable current, independent of ambient temperature. Mid-trip handle to indicate clearly a breaker operation caused by electrical fault. With unique arc chute design which results in high interrupting capacities. Up to 3 poles which all break its electronic circuits when 1 breaker trips, for optimal protection of the system. Wide range of currents from 100 A to 700 A and many options available. Application To be used in every high current application where electrical systems, circuits or components must be protected against too high currents. This situation can occur, when under strained or heavy use a motor or other load-generating component within the equipment will draw additional current from the power source. High currents cause the wires or components to overheat and ultimately burn up. A circuit protection device should be employed at any point where a conductor size changes. Many electronic circuits and components like transformers have a lower overload withstand threshold level than conductors such as wires and cables. These components require circuit protection devices featuring very fast overload sensing and opening capabilities. The FR circuit breaker can be used in all Railway applications where protection against overload and short circuit is necessary, for example HVAC systems, (door) control systems, braking systems, passenger information systems, etc. Proven reliable Long term availability Low lifecycle cost No maintenance Railway compliancy All our circuit breakers are designed according: IEC 60077-1/2/3/4 NF F62-001 - 1/2/3 NF F16-101/102 EN 45545-2 EN 50155 EN 61373 EN 50124-1 IEC 60068-2-30 IEC 60068-2-52 NF F61-010 MIL Method 107D, condition A MIL-STD-202G, Method 204C 1

Technical specifications Electrical characteristics Application voltage Rated voltage Min. operating voltage Max. operating voltage Current ratings Dielectric strength Creepage and clearance Insulation resistance Operating frequency DC for 1-3 poles 12-110 VDC 8.4 VDC 137.5 VDC AC for 1-3 poles 12-251 VAC 10.8 VAC 277 VAC Remark: DC applications: max. 250 A for 1 pole 300 A - 450 A for 2 poles (parallel pole construction) 500 A - 700 A for 3 poles (parallel pole construction) AC applications: max. 250 A for 1-3 poles 100-700 A. Other ratings on request. 1960 VAC, 50/60 Hz for 1 minute between all electrically isolated terminals. EN 50124-1 8 mm spacing requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits. Minimum of 100 MΩ @ 500 VDC 50/60 Hz, DC Max. interrupting capacity IEC 60947-2 UL 489 UL 489A UL 489 Auxiliary switch 25.000 A @ 125 VDC, 50-250 A 50.000 A @ 125 VDC, 50-250 A 50.000 A @ 125 VDC, 251-700 A 10.000 A @ 277 VDC, 100-250 A Integrated, load side. SPST. Auxiliary switch senses the on-off position of circuit breaker handle, as well as the open-closed position of breaker contact. AC min. switching capacity Silver auxiliary contacts 5-20 VAC: 100 ma > 20 VAC: 10 ma Gold auxiliary contacts 5 ma / 5 VAC AC max. switching capacity 5 A / 125 VAC 100 ma / 125 VAC DC min switching capacity DC max. switching capacity All loads mentioned are resistive loads. < 20 VDC: 100 ma > 20 VDC: 10 ma 3 A / 32 VDC 100 ma / 125 VDC (max. 2000 cycles) 5 ma / 5 VDC 100 ma / 32 VDC 2 ma / 110 VDC (max. 2000 cycles) 2

Technical specifications General characteristics Number of poles Terminals Auxiliary contacts Mounting Body Actuator handle Int. circuit configuration Weight Width per pole 1, 2 or 3 poles Stud / screw / box wire connector, see circuit & terminal diagrams Faston or solder type, see circuit & terminal diagrams The hydraulic-magnetic circuit breakers of Mors Smitt can be mounted in any position. A hydraulic-magnetic breaker is designed to must hold at 100% of the breaker s current rating and is calibrated to must trip at 125% of the breaker s current rating. If the mounting position is +90 degrees from a vertical panel mount (handle facing down, ceiling mount position) the trip and must hold rating is reduced by 10%. Blue colour Black or white with I O and On-off legends Series trip 950 gram per pole (average, depending on configuration) 38.1 mm Material Half shell - BMC 605 Handle - Valox 420SEO UL94V0 Terminals - Brass with acid tin plate Mechanical characteristics Endurance Trip indication: Standard (no mid-trip) Mid-trip Mid-trip with alarm switch Single or multipole: 8.000 operations @ 5 per minute (4.000 ON-OFF operations with rated current and voltage + 4.000 operations with no load). Parallel pole construction: 1.000 operations with rated current and voltage @ 5 per minute. When manually moving the operating handle from OFF to ON position, an auxiliary switch is actuated. When an overload or a short circuit causes the circuit breaker to trip, the operating handle moves positively to the OFF position and the auxiliary switch is actuated. When manually moving the operating handle from OFF to ON position, an auxiliary switch is actuated. When an overload or a short circuit causes the circuit breaker to trip, the operating handle moves positively to the mid position and the auxiliary switch is actuated. When manually moving the operating handle from OFF to ON position, an auxiliary switch is not actuated. When an overload or a short circuit causes the circuit breaker to trip, the operating handle moves positively to the mid position and the auxiliary switch is actuated. In this case the auxiliary switch is only actuated by an electrical trip, not by manually operating the handle. Remark: It is possible to manually switch the circuit breaker to the mid-trip position when the handle is switched from OFF to ON position quickly and with strong upwards force. Normally this won t occur in standard use. This is a normal phenomenon related to the design of the product. 3

Technical specifications Environmental characteristics Environmental Complies to EN 50125-1 and IEC 60077-1 Operating temperature -50 C...+85 C Vibration Shock Thermal shock Salt spray IEC 61373, Category 1, class B body mounted IEC 61373, Category 1, class A & B body mounted Complies to MIL-PRF-55629 & MIL-STD-202 Complies to MIL-PRF-55629 & MIL-STD-202 Fire & smoke Complies to NFF 16101, NFF 16102 Protection Moisture resistance / humidity IEC 60529, IP40 when a panel is mounted over the circuit breaker Complies to MIL-PRF-55629 & MIL-STD-202 Resistance, impedance Resistance, impedance values from Line to Load terminals (Values based on series trip circuit breaker) Current (amps) Tolerance (%) 100-700 + 50% Ohms Ampere rating 4

Technical specifications Table of time delay values ( ) 11 12 14 16 22 24 26 No Trip No Trip No Trip No Trip No Trip No Trip No Trip.013 -.125.475-10.0 10.0-11 0 11 0-1000.700-12.0 10.0-16 0 50.0-70 0.010 -.070.275-2.80 6.00-40.0 60.0-40 0.350-4.00 6.00-60.0 32.0-35 0.008 -.032.140 -.850 2.50-15.0 22.0-15 0.130-1.30.220-20.0 10.0-90.0.006 -.020.030 -.190.500-3.00 4.00-25.0.027 -.220.300-3.00 1.50-15.0.005 -.020.015 -.125.180-1.00 1.00-5.50.008 -.130.050-1.30.500-7.00.004 -.020.010 -.050.010 -.280.010-1.80.004 -.090.007 -.500.020-3.00.004 -.020.008 -.038.008 -.080.008 -.390.004 -.045.005 -.060.006-2.00 Notes: Delay curves 11, 12, 14, 16, 21, 22, 24, 26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve All curves: Curve data shown represents breaker response at ambient temperature of 25 C (77 F) with no preloading. Breakers are mounted in standard wall-mount position. Delay times may vary at different temperature, the trip current rating remains unchanged The minimum inrush pulse tolerance handling capabilities is 10 times rated current based on a 60 Hz 1/2 cycle, 8.33 ms pulse 5

Time delay values AC AC Short ort F SERIES 50/60 HZ SHORT CURVE NO. 22 Ultrashort Short Medium Medium F SERIES 50/60 HZ MEDIUM CURVE NO. 24 Medium Long g F SERIES 50/60 HZ LONG CURVE NO. 26 Long 6

Time delay values DC Ultrashort ashort DC Short rt Medium Medium Long Long 7

Circuit & terminal diagrams Notes 1 All dimensions are in inches [millimeters] 2 Tolerance ±0.020 [0.51] unless otherwise specified 8

Circuit & terminal diagrams F-Series Handle Circuit & Terminal Diagrams 5 F-Series Handle Circuit & Terminal Diagrams 5 Non-parallel pole construction (1-3 pole) Notes 1 All dimensions are in inches [millimeters] 2 Tolerance ±0.020 [0.51] unless otherwise specified 9

Circuit & terminal diagrams Parallel pole construction (2-3 pole) Notes 1 All dimensions are in inches [millimeters] 2 Tolerance ±0.020 [0.51] unless otherwise specified 10

Circuit & terminal diagrams CODE 3 Notes 1 All dimensions are in inches [millimeters] 2 Tolerance ±0.020 [0.51] unless otherwise specified 11

Circuit & terminal diagrams Notes 1 All dimensions are in inches [millimeters] 2 Tolerance ±0.020 [0.51] unless otherwise specified 12

Circuit & terminal diagrams F-Series Handle Form & Fit Diagrams 9 (contact Mors Smitt for more information) Notes 1 All dimensions are in inches [millimeters] 2 Tolerance ±0.020 [0.51] unless otherwise specified 13

Ordering scheme FR 2-820 - 14 - B - A - 2-0 - 1 - A - B - A 1. Series 2. Poles 3. Current rating 4. Frequency 5. Circuit 6. Actuator 7. Actuator 8. Auxiliary 9. Terminal 10. Mounting 11. Max. 12. Agency & delay colour & switch application approval legend rating 1 Series FR 2 Poles 1 One 2 Two 3 Three 3 Current rating (amperes) 810 100.0 812 120.0 912 125.0 815 150.0 917 175.0 820 200.0 922 225.0 825 250.0 830 8 300.0 835 8 350.0 840 8 400.0 845 8 450.0 850 8 500.0 860 8 600.0 870 8 700.0 4 Frequency & delay 11 DC ultra short 12 DC short 14 DC medium 16 DC long 22 50/60 Hz short 24 50/60 Hz medium 26 50/60 Hz long 5 Circuit Single pole or multi-pole (max. 250 A) B Series trip (current) Parallel pole construction (300 A - 700 A) P 1 Series trip (current) 6 Actuator 2 A S T Handle, one per pole Mid-trip handle, one per pole Mid-trip handle, one per pole & alarm switch 7 Actuator colour & legend Actuator colour I-O ON-OFF Dual Legend colour White A B 1 Black Black C D 2 White 14

Ordering scheme 8 Auxiliary switch 3 0 Without auxiliary switch 2 SPDT, 0.110 QC terminals 3 SPDT, 0.139 solder lug 4 SPDT, 0.110 QC terminals (gold contacts) 9 SPDT, 0.187 QC terminals B 4 SPDT, 0.093 round QC terminals 9 Terminal Back connected (front mounted only) Max. rating 1 5 Stud 3/8-16 250 A 2 6 Screw, line & load 3/8-16 700 A 5 6 Short stud 3/8-16 250 A Front connected (back mounted only) 7 Max. rating 3 Box wire connector, line & load 700 A 4 6 Screw, line & load 3/8-16 700 A 10 Mounting Front mounting inserts Back mounting inserts A 10-32 10-32 screw clearance holes B ISO M5 10-32 screw clearance holes 11 Maximum application rating Voltage Current B 125 VDC 700 A C 8 120/240 VAC 250 A F 277 VAC 250 A 7 9 120/208 VAC 250 A 12 Agency approval A No approval 10 Notes: 1. Parallel pole constructions are supplied with factory installed busbar on line and load 2. Actuator code: S: Handle moves to mid-position only upon electrical trip of the breaker T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker 3. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole (rear view) On parallel pole constuction breakers, one auxiliary switch is supplied, mounted in the extreme left pole (rear view) Back mounted breakers require special mounting provisions when an auxiliary switch is specified 4. Only available for and must be used with parallel pole construction 5. An anti-flash over barrier is supplied between poles on multipole breakers with 3/8-16 stud terminals 6. Terminals 2, 4 & 5 are shipped without terminals hardware 7. Box wire connector will accept #6 through 250 MCM copper wire 8. 2- or 3-pole circuit breaker required for 120/240 VAC rating 9. 3-pole circuit breaker required for 120/208 VAC rating 10. TUV certified: possible on request 15

DS-FR circuit breakers-v1.3 February 2017 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales.msf@wabtec.com Mors Smitt Asia Ltd. 29/F., Fun Towers, 35 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E sales.msa@wabtec.com Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311 E sales.msbv@wabtec.com Mors Smitt Technologies Inc. 1010 Johnson Drive, Buffalo Grove, IL 60089-6918, USA T +1 847 777 6497, F +1 847 520 2222 E salesmst@wabtec.com Mors Smitt UK Ltd. Graycar Business Park, Barton under Needwood, Burton on Trent, Staffordshire, DE13 8EN, UK T +44 (0)1283 722650 F +44 (0)1283 722651 E sales.msuk@wabtec.com RMS Mors Smitt 6 Anzed Court, Mulgrave, VIC 3170, AUSTRALIA T +61 (0)3 8544 1200 F +61 (0)3 8544 1201 E sales.rms@wabtec.com (c) Copyright 2017 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. Mors Smitt does not warrant that any of the information contained herein is complete, accurate, free from potential errors, or fit for any particular purpose. Mors Smitt does not accept any responsibility arising from any party s use of the information in this document.