Technika Światłowodowa R

Similar documents
Slimax LED Curing Light System

LED Headlight User s Manual

Endodontic Handpiece (GT) USER MANUAL

LED HANDHELD SLIT LAMP

TPC. User Manual. LED 70N Cordless LED Curing Light

TPC. User Manual LED 55N. Cordless LED Curing Light. All instructions in this USER S MANUAL must be completely read before installation or operation.

OPERATION & MAINTENANCE INSTRUCTIONS

Handheld LED Light Source (HLS) Operator s Manual

HEINE NT4 MED V

OPERATION & MAINTENANCE INSTRUCTIONS

LLS-2054BE. Smart Battery Pack Operator Manual. ST Technologies 6018 Bowdendale Avenue Jacksonville, FL USA

OPERATION & MAINTENANCE INSTRUCTIONS

Rechargeable laryngoscope handles Directions for use

ART-L5 LED CURING LIGHT. Directions for Use

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Operation Manual. Battery Charger ARTIKEL CHF CHF-4803

User Manual SPOTTING SCOPE X 60

Operating instructions in the back. PD1420LP

Instructions for use. Quick couplings RQ-03, RQ-04, RQ-14, RQ-24, RQ-34

Operating instructions in the back. PD1820LF

Instructions for use TKR POSITIONERS TKR TKR. Contents

IsoLED FLEX I CUSTOMER MANUAL

Instructions for use of S5 Endo Motor

AquaLift Bath Lift System MODEL #8100

HEINE Laryngoscopes. Quality you can rely on. Always. NEW!

MICRO GLASS CAPILLARIES

Keeler Spectra Plus. Instructions. Next

Xenon Fiberoptic Lightsource

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

Rev Miniature / Miniature K. Silent Power Evo 2 / 2L / 4L / 4LK / ENGLISH...2

Instructions for use AM-25 LT AM-25 A, AM-25 A BC/RM AM-25 E, AM-25 E BC/RM AM-25, AM-25 BC/RM

portable ac/dc suction pump USER S MANUAL ITEM # 18605

AFTER SALES SUPPORT MODEL NUMBER: 45682

Rev ENGLISH..2

UV-AIRE AIR PURIFYING SYSTEM

Li-Ion. Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany X22 (2011.

Safety information on VIKING type AAI lithium-ion batteries for use in imow robotic mowers

User's Manual. Battery Pack. powerpackpoint

THE HEINE F.O. LARYNGOSCOPE RANGE WITH THE PLUS

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Environmental Monitoring Microbial Air Sampling RCS High Flow Touch

About this user guide

LED-HL2-CMP LED Headlight System Operation Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual

SurePower Battery Pack Guide

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

CappController Pipette Controller. Operation Manual Version: 1.2.

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

HEINE Laryngoscopes The F.O. Laryngoscope range with the PLUS.

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Resuscitation System Model 100

XeVision XeRay XV-LX50 HID Searchlight

INSTRUCTION MANUAL Skin 2

Model 605 Portable Aspirator

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

XLR-IR850 Long-Range Infrared Illuminator

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

ILLUMINATING EYE MASSAGER

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Marlin Bath Lift BLM-8200 WARNING! Read ALL instructions before using this product!

Model 3342ARM1. Solar Rock Light. Solar Powered Accent Light. Operates automatically during nightfall

Megohmmeter Test Probe

Operating instructions Accu Jet

Astor 20 Colony Counter User s Manual

Mod: KLD6-12/35XLAS-N

PILOT S GUIDE. for the XX Series Electric Attitude Indicator with Battery Backup

Corded and Cordless LED Worklight

USE, CARE & STERILIZATION INSTRUCTIONS. Consumable Accessories Burs Saw Blades K-Wires Steinmann Pins Twist Drills Rasps Ortho Pins/Drills Guide Wires

Electronic Cordless Sweeper. Operating Instructions

PILOT S GUIDE. for the XXX Series Electric Attitude Indicator with Battery Backup

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

6 Bay Battery Charger Operation Manual

KHYBRID. Hybrid Mechanical Backlit Keyboard. Installation Quickguide

For Jacket Models: 9JKPPSSBL, 9JLPPSSBL, 9JKPPFLBL, 9JLPPFLBL & Vest Models: 9VEPPFLBL, 9VEPPFLBL

SurePower TM II Battery Pack Guide

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

Assistant s Instrumentation T

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

CRAFTAP 3 Brief Manual

LARYNGOSCOPES. HEINE SANALON+ Fiber Optic Laryngoscope Blades. Reusable Emergency Laryngoscope Blades

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

HEINE Mac Modular+ Fiber Optic Laryngoscope Blades

Armon Edero. User manual

Personal PA Receiver, PPA R19

Caution Wear protective glasses and turn your face away when connecting or disconnecting from the battery.

Register your product within 30 days of purchase to activate your one-year limited manufacturer s warranty at ovente.com/register

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

Installation manual wall-mounted distributor

60V RECHARGEABLE LITHIUM-ION BATTERY

Electro-hydraulic crimping tool AH-12. Art convincing solutions. Video

Tempo PIPETTE CONTROLLER USER GUIDE. Masters of precision

3-Year Limited Warranty. See the Users Manual for the full warranty.

4. TECHNICAL SPECIFICATIONS

Transcription:

Technika Światłowodowa R 05-092 omianki ko³o W-wy ul.kolejowa 14 tel/fax 48.22.7510292 tel 48.22.4982666 www. bobts.pl e.mail bobts@bobts.pl OPERATION MANUAL RECTOSCOP LED TYPE BOB R OM led Date of issue: Łomianki 22.01.2016

TABLE OF CONTENTS 1. Device designation... page 2 2. Specifications and symbols... page 2 3. Device construction... page 3 4. Safety and use... page 3 5. Operation... page 4 6. Cleaning... page 4 7. Possible damages and remedies... page 5 8. Repairs conditions... page 5 9. Inspections... page 5 10. Protection of the environment - recycling... page 5 Page 1

1.DEVICE DESIGNATION Rectoscopy portable type BOB - R OM LED is adapted for use with disposable tubes. It is a medical device designed for the diagnosis and treatment of diseases the anus, the rectum and the sigmoid colon. If you use disposable tubes it is recommended to use tubes of producers that have the marketing authorization: WING PLAST - Quality Medical Instruments: sigmoidoscopy tube with obturator diam. 20mm length 250mm - Ident. 1561 proctoscopy tube with obturator diam..20mm length 130mm - Ident. 1551 HEINE Optotechnik GmbH: sigmoidoscopy tube with obturator diam. 20mm length 250mm No. E-03.18.825 E-03.18.811 proctoscopy tube with obturator diam. 20mm length 130mm No. E-03.19.825 E-03.19.811 anoscopy tube with obturator diam. 20mm length 85mm No. E-03.19.925 E-03.19.911 The disposable tube is constructed in such a way, that the light emitted by the LED is transmitted to the rectoscopy head and next- through a bundle of optical fibers in the head -to the end of the tube, illuminating the field of view. 2.SPECIFICATIONS AND SYMBOLS BOB R OM- led Medical illuminator RECTOSCOPY HEAD LIGHT SOURCE POWER SUPPLY Light source - led diode - external diameter - magnifying eyepice - 30 mm - 1,5x LED DIODE - 5W Lithium-ion battery Type 18650 3400mAh 3,7V - lighting time 5 hour - charging time 10-12 hours Page 2

3.DEVICE CONSTRUCTION 1 2 3 4 5 L0 SN.L 2160 11 8 7 6 Rektoskop consists of: * Rectoscopy Head (1) with tightened to the device disposable tubes (2) and eyepiece (3) * Manual air pump (4) * LED light source buit-in permanently in the handle (5) with switch and light intensity adjustable(6) * 2 pieces of batteries * Battery Charger (8) 4.SAFETY AND USE DO NOT LEAVE THE BATTERY IN THE MACHINE WHEN IT IS NOT USED FOR A LONG TIME. discharged battery must be charged immediately. Do not modify without authorization of the manufacturer. If the device is modified, adequate inspection and testing should be made to ensure the safe continuity using of the device Page 3

5.OPERATION * Remove the battery tray (7) * Place the battery in the handle (5) * Connect the handle (5) to the rectoscopy head (1) * Disposable tube (2) screw onto the rectoscopy head (1) * Slide the rubber tubule of insufflation pump (4) onto the rectoscopy head connector * Holding the handle insert the obturator tube through a hole in the rectoscopy head (1) -strongly down to stop point. * Hold the obturator with thumb. * Turn the light source on. (6) * Rectoscopy is ready for application. * After applying remove the obturator and select required illuminance with the knob (6) * To the rectoscopy head (1) is attached the eyepiece (3), which is to seal optical fiber head and gives larger (1,5 x) image of observed field Charging the battery. To charge the battery:, unscrew the battery tray (7) holding the handle. Pass the battery to the charger (full charge of 10-12 hours). You must carefully mount a battery into the charger and validate the accordance with the designation (+), (-). 6.CLEANING The rectoscopy head - after separating it from the handle and a disposable tube must be cleaned immediately after use ( to prevent drying of the residue.) It is advisable to wash with a soft brush using soapy or pure water. If it is washed in a washing machine or with chemicals, follow the recommendations of the chemicals' manufacturer. Clean the polished outlets of the optical fibre bundles very carefully. The handle can be cleaned by washing it with a cloth with disinfectant. Do not clean with ultrasounds! After washing, rinse thoroughly with demineralised water and dry in max. 65 degrees C. Disinfection We advise soaking in a disinfectant or a thermochemical disinfection in max. 65 degrees C in a water steriliser. Strictly follow the disinfectant manufacturer's recommendations! Failure to follow the disinfectant manufacturer's recommendations may result in damaging of the rectoscope head. After disinfection, rinse with sterile demineralised water and dry thoroughly with a sterile gauze. Sterilization The head sterilization is not required for the diagnostic purposes application. After washing as described above, the head may be sterilized with ethylene oxide at a temperature of 65 degrees C. Autoclaving (type S or B) can be carried out under the conditions specified by the manufacturer. We do not recommend instant sterilization in an autoclave or sterilization with use of dry air. Page 4

7.POSSIBLE DAMAGES AND REMEDIES The device switched on; The device switched on; a lack of light; - discharged battery; to charge the battery a lack of light; - charged battery; repair service 8.REPAIR CONDITION Upon general terms, manufacturer provides 36-month guarantee starting at the date of purchase. Guarantee does not cover: - Mechanical damage to casing - Damage due to misuse of the illuminator After the guarantee period manufacturer provides paid service. Production and services: BOB Technika Światłowodowa 05-092 Łomianki near Warsaw, ul. Kolejowa 14, phone / fax 0 22 751 02 92, phone 0 22498 26 66 e-mail: bobts@bobts.plwww.bobts.pl Serial number Date and signature E 0003504W 9.INSPECTIONS Manufacturer expects the rectoscope's life to be 10 years. It is possible to extend the life by three more years ( upon positive inspections.) Obligation to make the inspections is imposed by the Medical Products Act of May 20, 2010, Journal of Laws No 107, item 679, art. 90, item 4 method and principles are set in the standard PN-EN 62353 "Electrical medical devices Periodical inspections and tests after repair of electrical medical devices". The following inspections are mandatory: 1. Before commissioning upon manufacturer's cost 2. After guarantee repair upon manufacturer's cost 3. After post-guarantee repair upon customer's cost Note that operation of device without valid periodical inspections infringes the Medical Products Act regulations and the Decision of the Ministry of Health "Medical Incident" (Journal of Laws 2011, No 33, item 167, February 02, 2011). 10.PROTECTION OF THE ENVIRONMENT-RECYCLING According to waste disposal act, Journal of Laws 2001.62.628 and Directive 91/689/EEC of the European Union it is forbidden to dispose electrical equipment to municipal dump. Customer is obliged to send used equipment to specialist company which will dispose of the equipment according to own or manufacturer's instruction. Page 5