Date: Customer: Project: Type: Qty: Saturn LED Order Code: SAL - - - - - - - - SAL Series SAL Saturn LED Pole Order Code: - - - Series Height Finish Options Optics TS Tritec Symmetric TA Tritec Asymmetric Mounting Single A Single Arm Mount Double W Wall Mount Light EngineL6 6W L50 50W CCT 30 3000K 40 4000K * For other CCT please consult factory Power Cord Length 8 0 4 6 8 XX 8 0 4 6 8 XX For mounting use the pole height. For A or mounting use the pole height + Finish WH White BK Black BZ Bronze SV Silver SP Specify Premium Color VoltageUNV 3 347 4 480 4 3 0-77V 4 Equipped with step-down transformer Options NH No Hoop HS House Side Shield (80 ) PCT Photocell Tenon See p. 9 for details DM Dimming (0-0V) PCT Photocell Tenon See p.9 for details HL30 5 Hi-Lo Switching Low Output 30% HL50 5 Hi-Lo Switching Low Output 50% 5 0V, 40V, & 77V only Motion Sensor w/ Optional Photocell See Pole Spec Sheet for Order Code Product Modifications Please list modification requirements for review by factory: Approvals 5YEAR LED WARRANTY Date: Page of
SAL-XX- 6 3/8 (670mm) 4 5/8 (65mm) Specifications Luminaire Cover - Spun aluminum cover made from low copper alloy, designed to ensure optimal thermal management for extra long life time of LED light engine. Cover Support - Machined support connected to fixture cover with architectural Allen head nut detail. Cover Set Screw - Two stainless steel, socket head cap screws provide attachment of fixture cover and support to (5mm) diameter connection rods. Loosening screwsallows removal of fixture cover without tools. Luminaire Hood - Aluminum shade with white painted interior for maximum reflectivity. Gasketing - Continuous gasket provides weatherproofing, dust and insect control at all fixture connections. LED Array - Mid-power LEDs mounted to aluminum core PC boards and attached to aluminum heat sink for maximum LED performance and life. CCT tolerance /4 step binning for 3000K. CRI minimum 80K. Complete light engine can be removed easily for future upgrade. LED light engine provides a reported lumen maintenance of 93% at 50,000 hours. L70 calculated greater than 00,000 hours. LED Optics - Symmetric or Asymmetric distributions created by conical textured reflector and patterned acrylic reveal with alternate LED PCB layouts. Type V and Type IV IES distribution types. An indirect lighting affect spreads brightness and improves visual appearance. LED Driver - LEDs are driven by RoHS compliant high-efficiency driver. Excellent for cold temperature starting and instant on. Pole Fitter - Self-leveling, die-cast low-copper aluminum alloy, fitter base secured to pole with three, stainless steel, Allen head set screws. Fitter for 3 / (90mm) O.D. poles. Diffuser - Clear, U.V. stabilized, acrylic with minimum wall thickness of 0.5 (3mm). Surge Protector - Designed to protect luminaire from electrical surge (0kA). Power Cord - Pre-installed at factory. Please specify power cord length in accordance to height of the pole. Add feet to power cord length if single arm mounting (A) or double mounting () is specified. Exterior Luminaire Finish - Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles are finished in our Tiger Drylac certified facility and undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultraviolet resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI. Standard exterior colors are White (WH), Black (BK), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. 5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the Saturn LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED array when installed and operated according to Selux instructions. For details, see Selux Terms and Condition of Sale. Listings and Ratings: Luminaire and LED tested to IESNA LM-79-08 standards. LED tested to LM- 80 standards. Luminaire and LED tested at 5 C ambient temperature. NRTL Listed (i.e. UL, CSA) Visit selux.us for our LED End of Life recycling policy. Page of
Motion Sensor Features The Selux outdoor rated sensor incorporates Passive Infrared (PIR) technology for motion sensing and also includes a built in photocell. Designed to mount directly through a / KO in a single gang faceplate on pole/column, the SBO utilizes 00% Digital Passive Infrared (PIR) technology that is tuned for walking size while preventing false tripping from the environment. Series MS Motion Sensor Optics 70 coverage - Single Sensor Hand Hole Orientation 00 Program D0 (0V=0%) Color WH White Photocell Feature Y Yes Voltage UNV 09 D (V=0%) BK Black N No REVISIONS 347 REV. ECN DESCRIPTION DATE BY APPR BY 8 D3 (3V=30%) 480 0 XXXX BZ Bronze CREATED FOR MARKETING 09//06 FAH DRW 7 D5 (5V=50%) TO DETAIL MODIFICATION TO A 007.7 POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION 07//07 FAH DRW LOGIC.000 5.40.500.70 " 305.00 (305mm) 4 X Ă.36 3.45 THRU 8-3 UNC THRU General Pole Drawing For Example Only 3.000 76.0.65 4.8.750 44.45 Nominal NOMINAL Pole POLE HEIGHT Height MINUS 3.50 " 8.55 3.500 88.90 X Ă.88 4.76 THRU.000 5.40.000 50.80 DETAIL A SCALE : Sensor Angular SENSOR Orientation ANGULAR ORIENTATION from hand FROM hole HAND 0 HOLE in 90 0Ø increments clockwise IN 90Ø around INCREMENTS pole CLOCKWISE (Type 00, AROUND 09, 8, POLE 7) (TYPE 00, 09,8, 7) 90 Ø (09) ANGULAR ORIENTATION FROM HAND HOLE 0Ā NTS CLOCKWISE AROUND POLE (TYPE 00,09,8,7) TYPE 09 (90Ā) Hand Hole Location HAND HOLD 0 (00) LOCATION 0 Ø (00) 80 Ø (8) TYPE 8 (80Ā) 70 Ø (7) alter the function TYPE 7 of (70Ā) the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. TOP VIEW Page 3 of
Motion Sensor Features 00% Digital PIR Detection, excellent RF Immunity 70 coverage pattern Up to 30ft mounting IP66 Rated for outdoor applications Built-in kv surge protection No minimum load requirements Made for LED light source Interchangeable hot and load wires - impossible to wire backwards Adjustable time delays, max/min dim levels and ramp rates Programming button accessible without opening sensor or removing gaskets No field calibration or sensitivity adjustments required Non-volatile setting memory Convenient test mode Suitable for Title 4 applications General Pole Drawing For Example Only Motion Sensor Wiring BLK WHT BLK VIO GRY SBO SENSOR BLK WHT GRN BLK WHT GRN RED ORG FIXTURE FEED CORD BLK WHT GRN RED ORG WEATHERPROOF WIRE CONNECTOR, 600V 8-8GA (SUPPLIED) LINE CORD ATTACH CORD TO BACK OF SENSOR MOUNTING PLATE WITH ZIP TIES (NOT SUPPLIED) Page 4 of
Mounting Single () Die-cast aluminum fitter base secured to pole with three stainless steel, Allen head set screws. Single Arm Mount (A) Die-cast aluminum single luminaire mounting arm secured to pole with four stainless steel, Allen head set screws. Outer slip fitter for 3/ tenon. Double () Die-cast aluminum double luminaire mounting arm secured to pole with four stainless steel, Allen head set screws. Outer slip fitter for 3 / tenon. Wall (W) Die-cast aluminum double round wall mount arm. Secured to wall with /4 diameter threaded fasteners (by others). EPA =.3ft (0.m ) Weight = 39lbs. (7.7kg) EPA =.3ft (0.m ) Weight = 53lbs. (4.0kg) EPA = 4.ft (0.39m ) Weight = 76lbs. (79.8kg) EPA =.ft (0.0m ) Weight = 50lbs. (.7kg) 6 5 /6 (668mm) 6 5 /6 (668mm) 35 (889mm) 70 (778mm) 35 (889mm) 4 5 /8 (65mm) 33 /6 (840mm) 33 /6 (839mm) 33 /4 (845mm) 5/6 (557mm) 5/6 (557mm) Pole Height 0 Shown Pole Height 0 Shown Wall Arm Mounting Detail (Conduit and mounting hardware by others). 4 5/6 (mm) 5 5/6 (5mm) 9 /4 (35mm) 9/6 (65mm) Page 5 of
Pole Information Refer to pole specification sheets for construction details, anchorage information and additional options. A35 & S35 Round Straight Aluminum & Round Straight Steel Poles S635 Round Stepped Steel Poles Base Cover Information Refer to pole specification sheets for construction details, anchorage information and additional options. Standard Base Cover (BC5) Supplied with A35 and S35 Two-piece cast aluminum Standard Base Cover (BC6) Supplied with S635 One-piece cast aluminum 3 / (89mm) 65/8 (68mm) Pole Height (8 shown) Ø 7/6 (36mm) 5 /4 (34mm) Ø53/4 (400mm) 45/8 (8mm) Optional Base Cover (BC) For A35 and S35 only One-piece cast aluminum 3/ (89mm) 4 (60mm) 4 (60mm) 44 (8mm) 5/8 (550mm) Shown with standard base covers. Ø 5/8 (30mm) Pole Data Chart Pole Series Bolt Circle EPA Information 70mph 80mph 90mph 00mph 0mph S635 3 / Diameter Stepped Steel Pole Ø9 57.6 44.3 34.6 7.5.8 A35 3 / Diameter Straight Aluminum Pole Ø7 3/4 6.. 9.4 7.3 5.9 S35 3 / Diameter Straight Steel Pole Ø7 3/4 4.8.3 8.6 6.7 5.4 S635 3 / Diameter Stepped Steel Pole Ø9 45.6 35.0 7.3.6 7.8 A35 3 / Diameter Straight Aluminum Pole Ø7 3/4.4 9.3 7. 5.4 4.3 S35 3 / Diameter Straight Steel Pole Ø7 3/4.4 8.6 6.5 4.9 3.9 S635 3 / Diameter Stepped Steel Pole Ø9 37.6 8.7.3 7.5 4.4 A35 3 / Diameter Straight Aluminum Pole Ø7 3/4 9.9 7.3 5.4 4.0 3. S35 3 / Diameter Straight Steel Pole Ø7 3/4 9. 6.7 4.9 3.6.8 S635 3 / Diameter Stepped Steel Pole Ø9 3.7 4. 8.6 4.6.9 A35 3 / Diameter Straight Aluminum Pole Ø7 3/4 8.0 5.8 4. 3.0. S35 3 / Diameter Straight Steel Pole Ø7 3/4 7.3 5.3 3.8.7.9 S635 3 / Diameter Stepped Steel Pole Ø9.7 5.8.3 9.6 7.6 A35 3 / Diameter Straight Aluminum Pole Ø7 3/4 4.9 3...4 N/A S35 3 / Diameter Straight Steel Pole Ø7 3/4 4.4.8.9 N/A N/A **Other pole configurations available, consult factory. Height Finish Options 8 8ft. 0 0 ft. ft. 4 4 ft. 6 6 ft. Effective Projected Area of Single Luminaire = 0.9 ft (0.09m) / Weight of Luminaire = 35.0 lbs (5.9kg) Effective Projected Area of Double Luminaire =.37 ft (0.m) / Weight of Double Luminaire (includes arms) = 94.0 lbs (4.6kg) WH White BK Black BZ SV SP Bronze Silver Specify Premium Color BC REC Decorative Cast Aluminum Base Cover (for A35 & S35 poles only) GFCI Receptacle with weather-proof cover REC GFCI Receptacle with padlockable in-use cover MS Motion Sensor w/ Optional Photocell For PCT option, See page * Weatherproof cover intended for portable tools or other portable equipment connected to the outlet only when attended. For other requirements please consult factory. Page 6 of
Bolt Circle for A35 & S35 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown Anchor Bolt Detail for A35 & S35 A35/S35 POLE ONLY 07 3/4 (97mm) Bolt Circle 3/4 x 7 Galvanized Anchor Bolts 3/4-0 Galvanized Heavy Hex Nut 7 3/4 (97mm) 03 (76mm) Conduit Opening 3 /4 (83mm) 3/4 (9mm) ID Galvanized Flat Washers Hand Hold Location Note: Adequate drainage must be provided in concrete foundation. / (3mm) for leveling 3/4-0 Galvanized Heavy Hex Leveling Nut Concrete footing designed and supplied by others Bolt Circle for S635 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown. Anchor Bolt Detail for S635 Base Cover 3/4 x 7 Galvanized Anchor Bolts 3/4-0 Galvanized Heavy Hex Nut 8 / (6mm) S635 POLE ONLY 09 (9mm) Bolt Circle 3/4 (70mm) 3/4 (9mm) ID Galvanized Flat Washers 06 3/8 (6mm) Conduit Opening Hand Hold Location Note: Adequate drainage must be provided in concrete foundation. /4 (6mm) for leveling 3/4-0 Galvanized Heavy Hex Leveling Nut Concrete footing designed and supplied by others Page 7 of
Wiring Standard Single Wiring Hi-Lo Switching Option (HL) Wiring HL30 & HL50 Only When red is energized, light output will be at Lo level. Specify low level by using one of the levels listed below (i.e. HL50 or HL30). For other combinations, consult factory. HL30 = low output 30% HL50 = low output 50% SURGE PROTECTOR L BLACK SURGE PROTECTOR FROM LINE CORD N WHITE GREEN LIGHT ENGINE FROM LINE CORD L N BLACK WHITE GREEN LIGHT ENGINE L RED RELAY 0-0V Dimming Option (DM) Wiring 0-77V. (347V and 480V available with step-down transformer.) 347/480 V SURGE PROTECTOR SURGE PROTECTOR AUTO TRANSFORMER L BLACK L BLACK FROM LINE CORD N WHITE GREEN LIGHT ENGINE FROM LINE CORD N WHITE GREEN LIGHT ENGINE Dim (+) RED Dim (-) ORANGE Page 8 of
Optional Accessories Photo Cell Tenon (PCT) - Button type photocell mounted in cast aluminum pole top tenon. Tenon has integral cast visor to prevent false start/stop cycle and can be oriented for optimum performance. Refer to luminaire spec sheet to determine if this option is applicable. GFCI Receptacle (REC) - 0V 5A GFCI duplex receptacle with weather-proof, self-closing cover; located 36 (95mm) from base of pole, inline with handhole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel. C) GFCI RECEPTACLE DETAIL (0V) 3/4 (70mm) 5/8 (5mm) 8 5/8 (9mm) 4 / (4mm) 5 5/8 (397mm) Pole (Generic View) 9/6 (4mm) Cover shown in the closed position Single Fusing (FS) - Single inline fuse holder, shipped separately for infield installation behind hand hole (by others). Available up to 77V. GFCI Receptacle (REC) - 0V 5A GFCI duplex receptacle with weather-proof, self-closing, padlockable in-use cover; located 36 (95mm) from base of pole, inline with handhole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel. 3 9/6 (9mm) /4 (58mm) 6 /6 (70mm) Cover shown in the closed position Pole (Generic View) Page 9 of
Optional Accessories House Side Shield Front View Side View NEED NEW DRAWINGS Page 0 of
Photometry TS / 50W LED / 3000K CCT 445 3.. Catalog #: SAL-TS-X-L50-30-XX-UNV Report #: 64853.0 Delivered Lumens: 58 Input Watts: 49.647W Efficacy: 03 CCT: 3K CRI (Ra): 8. Maximum candela of 445.3 at 55 from vertical IES classification: Type VS Mounting Height: 6 (4.9 m) BUG Rating: B-U3-G Power Factor: 0.995 Total Harmonic Distortion: 7.8% 084 73 36 0.75.75 3 4.5 House Side Street Side Maximum Candela = 445.3 Located At Horizontal Angle = 65, Vertical Angle = 55 # - Vertical Plane Through Horizontal Angles (65-345) (Through Max. Cd.) 5 0.53 3.75 45 67 Distance In Units Of Mounting Height Values Based On 6 Foot Mounting Heigh t TA / 50W LED / 3000K CCT 305 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINANCE 3 Catalog #: SAL-TA-X-L50-30-XX-UNV Report #: 459.04 Delivered Lumens:4489 Input Watts: 48.3057W Efficacy: 93 CCT: 3K CRI (Ra): 8. Maximum candela of 304.7 at 5.5 from vertical IES classification: Type IV Mounting Height: 6 (4.9 m) BUG Rating: B-U3-G Power Factor: 0.995 Total Harmonic Distortion: 7.8% 979 65 36 0.75.75 3 4...5 House Side Street Side Maximum Candela = 304.7 Located At Horizontal Angle = 5, Vertical Angle = 5.5 # - Vertical Plane Through Horizontal Angles (5-85) (Through Max. Cd.) 5 0.53 3.75 45 67 Distance In Units Of Mounting Height Values Based On 6 Foot Mounting Heigh t Saturn LED Lumen Matrix Model# Watts Delivered Lumens SAL Toolbox Scale Factor Lumens/Watt Light Engine Multiplier CCT Multiplier Symmetrical Diffuser 6 30 XX UNV 7.66 767.0000 00.0 0.540 50 30 XX UNV 49.65 58.0000 03.3.000 Asymmetrical Diffuser 6 30 XX UNV 4.5 0.0000 9.9 0.495 50 30 XX UNV 48.30 4489.0000 9.9.000 Symmetrical Diffuser 6 40 XX UNV 7.69 837.054 0.5.05 50 40 XX UNV 49.84 558.054 05.5.05 Asymmetrical Diffuser 6 40 XX UNV 4.3 76.054 94.3.05 50 40 XX UNV 48.9 4603.054 95.3.05 3000K CCT Multiplier =.000 4000K CCT Multiplier =.05 Page of