TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

Similar documents
DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

PeroxiDraw Dispenser

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

Intended Use: Explanation of Signal Word Consequences

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

SAFETY INFORMATION & INSTRUCTION MANUAL

DEMA Pro-Fill I Sink Dispenser

DEMA Pro-Fill II Sink Dispenser

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

Spray Clean 606T-2 Installation Instruction

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

665 Series Dispenser. Metering tip kit

Certo Chemical Dilution System

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

I Button Chemical Dispenser. Overview. Installation Instructions

Spray & Foam Dispenser Item #

SAM SPARTAN ACCURATE MEASURE DISPENSING SYSTEM INSTALLATION INSTRUCTIONS MODEL 681-3SAM 1. PARTS: A. SAM

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Tools Needed for Mounting Cleá Filling Station

DEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Items # and #

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

BLACK SHADOW SERIES DISPENSER. Tools Needed for Mounting SCS Dispenser Hammer Drill with 1/4, 1/8, 9/32 and 5/32 Diameter Bits Pliers

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Trident Laundry Chemical Delivery System

PROMAX INSTRUCTION MANUAL

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

D EMA TWO-STAGE INJECTOR MODELS 233, 234A, 236A, 236-8, 238, AND 2312 INSTALLATION INSTRUCTIONS FIGURE 3 FIGURE 2

DART Ware Wash Speed Control

DEMA SQUIRT DRAIN UNIT

DEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)

Dilution Control Systems. Multi-Task Dispenser Model #421700PL OPERATION SERVICE PARTS CARE. Dema #i GAPDB-MC2

DEMA Nitro for Europe Ware Wash Chemical Dispensing

Trapper Drain Maintenance/Odor Control Chemical Dispensing

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

DEMAMaster TM DM-811 Series Installation Manual

Table of Contents. Introduction. KP1H Components... 2 Installation and Assembly

DEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.

SOLUTION STATION Instruction Manual

Caution! Pg. 1 of 5 I-932

Drain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing

Technical Manual. Table of Contents

(Airgap)

BIOACTIVE SOLUTIONS AC DRAIN STATION

THANK YOU FOR CHOOSING BATHERBOX GETTING STARTED WHAT S IN THE BOX? N. Northview Ave Sioux Falls, SD 57107

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

Reference Manual FM-200 Series

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

Installation Instructions

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

ILCS EDGE System Installation Manual

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

Shower System. Dual Head INSTRUCTION GUIDE

CHEMICALS ONE-WASH ( ) fax (662) HYDROMINDERS HYDROMINDER TIP SELECTOR HYDROMINDERS

HALLMARK INDUSTRIES INC

910 BHF OWNER S MANUAL. Pg. 1 of 9

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

ICS Integrated Cleaning System. Rechargeable Battery

Instruction Manual. This Manual should be made available to persons responsible for Installation, Operation and Maintenance. Pump Model No...

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717

Modular Outdoor Fountain System

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

MAC FAUCETS FA400 WALL MOUNT FAUCETS

Model 8346/8346CRP Shower & Eye/Face Wash

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

PARTS AND INSTALLATION MANUAL

ILCS EDGE Jr EDP Installation Manual

Single shot MODEL EGA700 OWNERS MANUAL

Transcription:

Blend Safe II Dispensing System is a modular, locking dispensing system that allows user to dispense chemicals safely, control dispenser inventory and has the flexibility in the field to meet changing requirements at different accounts. 1. PARTS CHECKLIST A. Blend Safe Assembly B. ¼ ID x 28 Long Vinyl Supply Tubing and Foot Valve C. Ceramic Weight D. Hose Hanger Assembly E. Drip Tray (1 GPM) F. Screw and Anchor Kit G. Label Card H. Metering Tip Kit I. Cabinet Lock Key Set J. Blend Safe Mounting Template (I-792-2) *Quantity varies depending on the model of the Blend Safe. 2. INSTALLATION: Note: All installations must conform to local plumbing codes and use approved backflow preventers. Pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee. WARNING: Water supply should not exceed 125 psi and water temperature must not exceed 150 F. A. MOUNTING AND WATER SUPPLY: Use mounting template enclosed to locate the mounting screw positions. Drill all of the holes into the drywall using a 1/4 diameter bit for use with the included #10 screw and anchor set. (If mounting the Blend Safe to wood and you do not plan to use the included anchors, drill 1/8 diameter holes.) Insert the anchors into drilled holes and hammer them into the wall until they are flush with face of wall. Assemble all of the #10 screws with a Phillips screwdriver into the anchors so the screw heads are sticking out of the wall approximately ½. Mount the Blend Safe by inserting the screw heads through the keyhole slots in the base and tighten the screws. The water inlet is equipped with a female garden hose fitting (with strainer washer) for attaching a water supply hose. The water inlet may be removed to permit direct connection to a 3/8 in. NPT pipe. The unit is designed so water can be supplied to either side by interchanging the pipe plug with the water inlet. Note: Apply pipe dope, hand-tighten, and then turn 1-1/2 times with a wrench. DO NOT OVER TIGHTEN. WARNING: Do not use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause the plastic to crack. Use a non-welding liquid sealant instead. The push button valves in the top of each station are connected using a hose barb and reinforced tubing. The bottoms of each station are connected to each other using box clips. Additional single-station units can be attached using DEMA kit #66-129. Kit #66-130 is used for attaching dual-station units to each other. B. PRESSURE INDICATING TEE INSTALLATION: Screw female quick disconnect to faucet and attach pressure indicating tee to female quick disconnect. Attach female end of reinforced hose to male threads of tee, then attach the male end to the female garden hose fitting at the water inlet of the Blend Safe (See Figure 3). 3. CHEMICAL INJECTION ADJUSTMENT: Warning: use care when handling hazardous chemicals. Chemical feed rates are controlled by metering tips screwed into the proportioner barb. Select a tip using Table 1 or 2 as a guide. 1 cps (centipoise) is equal to the viscosity of water 75 cps is approximately equal to the viscosity of 10 weight motor oil 200 cps is approximately equal to the viscosity of most dishwashing detergents TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color 1 cps 75 cps 200 cps Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Tan 1.03 125-1 0.76 168-1 0.38 333-1 Orange 1.24 103-1 0.98 130-1 0.53 241-1 Turquoise 1.43 89-1 1.07 119-1 0.61 211-1 Pink 2.47 52-1 1.58 81-1 0.92 139-1 Light Blue* 3.05 42-1 2.1 61-1 1.06 121-1 Brown 3.48 37-1 2.31 55-1 1.15 111-1 Red 4.38 29-1 2.83 45-1 1.23 104-1 White 5.33 24-1 3.1 42-1 1.37 93-1 Green 6.38 20-1 3.63 35-1 1.4 91-1 Blue 6.77 19-1 3.78 34-1 1.45 88-1 Yellow 9.90 13-1 5.1 25-1 1.48 86-1 Black 15.00 9-1 6.54 20-1 1.53 84-1 Purple 24.94 5-1 7.28 18-1 1.57 82-1 Gray 35.94 4-1 8.5 15-1 1.64 78-1 No Tip 73.21 2-1 9.35 14-1 1.87 69-1 TABLE 2-4 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING I-792 Pg. 1 of 7

Injection Rates For Viscosities Shown Metering Tip Color 1 cps 75 cps 200 cps Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Tan 0.33 387-1 0.26 500-1 0.12 1090-1 Orange 0.42 307-1 0.32 430-1 0.17 735-1 Turquoise 0.51 251-1 0.34 382-1 0.19 676-1 Pink 0.78 165-1 0.56 230-1 0.3 422-1 Light Blue* 0.87 147-1 0.67 192-1 0.33 391-1 Brown 0.99 129-1 0.74 174-1 0.37 345-1 Red 1.37 93-1 0.91 141-1 0.44 289-1 White 1.52 84-1 1.04 123-1 0.48 264-1 Green 1.72 74-1 1.22 105-1 0.52 244-1 Blue 2.13 60-1 1.27 101-1 0.54 239-1 Yellow 3.05 42-1 1.71 75-1 0.56 229-1 Black 4.50 28-1 1.96 65-1 0.57 224-1 Purple 7.75 17-1 2.4 53-1 0.59 217-1 Gray 9.86 13-1 2.54 50-1 0.63 204-1 No Tip 19.63 7-1 3.16 40-1 0.67 190-1 NOTE: *Metering tip color was formerly clear. All induction rates are base on a water pressure of 40 psi. Leaner dilutions can be achieved by ordering DEMA ultra lean tip kit 100-15KU or capillary tip 44-61P. C. CHEMICAL SUPPLY: Remove Blend Safe cover. Slip a ceramic weight over the chemical supply tube. Install the tubing by pushing tubing over the barb located on the proportioner (Refer to Figure 1). Place the chemical container inside the case. Run tube down back of Blend Safe through the holes in the back of the Blend Safe and insert the foot valve end of the tubing into the chemical container. Repeat for each chemical. Peel-off gummed labels are provided for labeling chemicals. D. DRIP TRAY: (1 GPM ONLY) The Drip Tray is installed inserting the tabs in back of drip tray through slots in door. Push tray down into place. Two-sided tape or Velcro (not included) may be used to secure drip tray to door. Attach tubing hanger to end of tubing, to hang up when not in use (For 4 GPM only). E. OUTLET TUBING: Attach one end of the ½ ID tubing to the proportioner outlet barb and run the other end through the hole located at the bottom of the case. Attach tubing hanger to end of tubing, to hang up when not in use. Do not force outlet tubing onto the larger barbs on the proportioner. 4. OPERATION The Blend Safe is now ready for use. Depressing a push button opens the valve allowing water to flow through the chemical proportioner that mixes a chemical water solution at the desired rate. The buttons are spring loaded to prevent accidental overflow if unattended, but may be converted to locking buttons by cutting off the tab at the notch (See Figure 2). Pushing the button and turning it a 1/4 turn clockwise at the end of its travel allows the valve to lock on. This makes it unnecessary for the attendant to hold the button while filling large containers. Turning the button in a counter-clockwise direction will release it, allowing the valve to shut off. 5. SERVICING Caution: Turn off water supply before servicing. A. Proportioner fails to draw chemical: 1. Pinch outlet tube to create back pressure, which will cause unit to prime. Then foot valve will keep the inlet tube primed. 2. Insufficient water supply pressure. 20 PSI is the minimum allowable. B. Proportioner stops drawing chemical: 1. Inspect foot valve for dried chemical or dirt. Soak in hot water to clean. 2. Proportioner metering tip clogged with dried chemical. Remove tip and try injecting in hot water. If there is no suction, remove proportioner and soak in hot water to clear interior passages. 3. Inspect proportioner to ensure that there are no mineral deposit build-ups on the nozzle. If so, soak proportioner body in de-liming solution. (Remove all parts attached to proportioner before soaking in de-liming solution.) Note: Use care when handling hazardous chemicals. C. Proportioner continues to draw chemical after water valve closes: Chemical supply is higher than bottom of discharge I-792 Pg. 2 of 7

tube creating a natural siphon. Lower the supply vessel or hang up outlet tube after use. D. Valve Malfunction: Check that the button moves freely in & out and that a "click" can be heard when the button is pushed and released, indicating that the magnet is activating the plunger properly. Remove cover. To inspect internal parts, unscrew magnet housing and carefully pull off the enclosing tube so as not to drop the plunger, kick-off spring, and spacer. Check for dirt or damage impending plunger and kick-off spring movement. Inspect the diaphragm, making sure the two small pin holes (bleed hole) in the diaphragm convolution are clear to allow the valve to close. Caution: When servicing unit, be sure that replacement parts have been installed according to the drawing. PRESSURE INDICATING TEE INSTALLATION OUTLET TUBING BLEND CENTER WATER INLET HOSE PRESSURE INDICATING TEE WATER INLET HOSE DETAIL OF PRESSURE I-792 Pg. 3 of 7

Inlet Hose Adapter Thumb Screw Push Button Actuator Action Gap Proportioner Metering Tip Chemical Supply Tube Outlet Tube Cabinet Lock with Keys Box Clip (3) Places Chemical Container Ceramic Weight Foot Valve Removable Drip Tray FIGURE 1 Push Button Utility Knife FIGURE 2 I-792 Pg. 4 of 7

12 14 15 See page 8 for breakdown 13 26 1 (SPECIFY COLOR) 2 (SPECIFY COLOR) 28 29 16 17 See page 8 for breakdown 3 4 18 19 27 5 7 20 23 6 8 9 30 24 10 21 22 (6" Long Tubing) (6' Long Tubing) 11 25 1 66-139 Magnet Housing (Specify Color) 2 66-140 Push Button (Specify Color) 3 63-35 Magnet 4 63-36 Spring 5 41-7-25 Enclosing Tube 6 63-87 Valve Repair Kit 7 63-37 Spacer 8 41-1-8 Kickoff Spring 9 63-38 Plunger 10 41-15-10 Diaphragm 11 63-39 Valve Body 12 100-38 Strainer Washer 13 66-156 Water Inlet Assembly 14 66-153 Pipe Plug & O-Ring Assembly 15 16-30 Action Gap Assembly 16 61-22-3 4 GPM (1/4 Barb) Proportioner (Gray) 17 61-99-2 1 GPM (1/4 Barb) Proportioner (Green) 18 63-78 O-Ring 19 63-79 Inlet Barb (1/4 Barb) 20 100-15K Metering Tip Kit 14 Sizes 21 16-3-6 ½ ID x 6 Lg. Outlet Tube (1 GPM) 22 89-30-5 ½ ID x 6 Lg. Hose Hanger Assy. (4 GPM) 23 100-12-16 ¼ ID x 28 Lg. Vinyl Supply Tube 24 61-107-2 Ceramic Weight 25 100-16E Foot Valve 26 66-64 Drip Tray 27 66-21 Cabinet Lock 28 67-4-1 Box Clip 29 66-63 Thumb Screw ACCESSORIES 30 68-6-QD2 Pressure Indicating Tee I-792 Pg. 5 of 7

1 2 5 1 6 3 4 1 150-6 Rubber Washer 2 61-36 Flow Disk 3 16-3-6 1/2 I.D. x 6 Lg. Vinyl Outlet Tube (1 GPM Only) 4 89-30-5 1/2 I.D. x 6 Lg. Hose Hanger Assy. (4 GPM Only) 5 63-89-1 Rubber Washer (1/32 Thick) 6 16-30 Action Gap Assembly Merchandise Returns No Merchandise will be Returned for Credit Without DEMA S Written Permission. Returned Merchandise Authorization Number is Required in Advance of Return. Product Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a I-792 Pg. 6 of 7

normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as O -rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of returned units for repair or replacement (See Merchandise Returns above). I-792 Pg. 7 of 7