CENTRAL MARKS DEPARTMENT II (Legal) Our Ref: CMD-II/16: 8034 21 July 2014 Subject: Implementation of Amendment No 3 December 2013 to IS 8034:2002 Submersible Pumpsets - Specification Amendment No 3 December 2013 to IS 8034:2002 Submersible Pumpsets - Specification has been issued (copy enclosed). This amendment does not require any change in the existing Scheme of testing and inspection DOC: STI/8034/5, August 2004. Hence, it has been to implement the said amendment with immediate effect. RO s/bo s are requested to inform all licensees and applicants about the implementation of amendment no. 3 issued to above ISS under their jurisdiction for necessary action and compliance. This is issued with the approval of the Competent Authority.. unil Kumar) (S Sc. F Head CMD-II (Legal) All ROs/BOs/SBOs/BIS Labs
AMENDMENT NO. 3 DECEMBER 2013 TO IS 8034 : 2002 SUBMERSIBLE PUMPSETS SPECIFICATION (Second Revision) (Page 1, clause 6.2.1, Sl No. 2) Insert or Nitrile rubber after IS 318 material of construction (Page 4, clause 7.1, Table 1) Substitute the following Tables 1 to 5 for Table 1: Table 1 Values of Performance Characteristics for 2-Pole, 415 V, 50 Hz Three Phase, Water Filled Submersible s for Bore Size Nominal 100mm and OD of 98 mm in the Operating Head Range for Checking the Nonoverloading Torque(In Terms of Percentage of Full Load Torque) kw A A Percent (1) (2) (3) (4) (5) 1.1 4.0 4.3 125 56 1.5 4.8 5.1 125 60 2.2 6.9 7.4 125 63 3.0 9.0 9.6 125 63 3.7 10.6 11.3 125 64 4.5 12.6 13.5 125 67 5.5 15.5 16.6 125 68 1 current limits specified are for 415 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage. 2 For three phase motors, the value of current shall be taken as average value of the current measured in three phases. 3 Values given in col 3 are 1.07 times of the values given in col 2. 4 Performance values of 4-pole three phase motors and 2-pole three phase motors of less than 1.1 kw and exceeding 5.5 kw rating shall be as declared by the manufacturer. 5 However, for three phase motors above 5.5 kw rating, the declared value of efficiency shall not be lesser than 5.5 kw value. 6 efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum-overall efficiency of the pumpset. Price Group 4 1
Table 2 Values of Performance Characteristics for 2-Pole, 415 Volt, Three Phase, Water Filled Submersible s for Bore Size Minimum 150 mm and OD of 146 mm in the Operating Head Range for Checking the Nonoverloading Torque(In Terms of Percentage of Full Load Torque) kw A A Percent (1) (2) (3) (4) (5) 1.1 3.3 3.5 125 57 1.5 4.5 4.8 125 66 2.2 6.5 6.9 125 67 3.0 8.5 9.1 125 67 3.7 10.0 10.7 125 68 4.5 12.0 12.8 125 70 5.5 14.5 15.5 125 73 7.5 19.5 20.9 125 74 9.3 25.0 26.7 125 75 11.0 29.0 31.0 125 76 13.0 34.0 36.4 125 77 15.0 39.0 41.7 125 78 1 current limits specified are for 415 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage. 2 For three phase motors, the value of current shall be taken as average value of the current measured in three phases. 3 Values given in col 3 are 1.07 times the values given in col. 2. 4 Performance values of 4-pole three phase motors and 2-pole three phase motors of less than 1.1kW and exceeding 15 kw rating shall be as declared by the manufacturer. 5 However, for three phase motors above 15 kw rating, the declared value of efficiency shall not be lesser than 15 kw value. 6 efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum overall efficiency of the pumpset. 2
Table 3 Values of Performance Characteristics for 2-Pole, 415 V, Three Phase, Water Filled Submersible s for Bore Size Minimum 200mm and OD of 196 mm in the Operating Head Range for Checking the Nonoverloading Torque (In Terms of Percentage of Full Load Torque) kw A A Percent (1) (2) (3) (4) (5) 3.0 8.5 9.1 125 69 3.7 10.0 10.7 125 70 4.5 12.0 12.8 125 72 5.5 14.5 15.5 125 75 7.5 19.5 20.9 125 76 9.3 25.0 26.7 125 77 11.0 29.0 31.0 125 78 13.0 34.0 36.4 125 79 15.0 39.0 41.7 125 80 18.5 48.0 51.3 125 80 22.0 57.0 61.0 125 80 26.0 66.0 70.6 125 81 30.0 76.0 81.3 125 81 37.0 85.0 91.0 125 82 45.0 100.0 107.0 125 82 55.0 120.0 128.4 125 83 63.0 135.0 144.5 125 83 67.0 144.0 154.1 125 84 75.0 158.0 169.1 125 84 1 current limits specified are for 415 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage. 2 For three phase motors, the value of current shall be taken as average value of the current measured in three phases. 3 Values given in col. 3 are 1.07 times the values given in col. 2. 4 Performance values of 4-pole three phase motors and 2-pole three phase motors of less than 3.0 kw and exceeding 75 kw rating shall be as declared by the manufacturer. 5 However for three phase motors above 75 kw rating, the declared value of efficiency shall not be lesser than 75 kw value. 6 efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum overall efficiency of the pumpset. 3
Table 4 Values of Performance Characteristics for 2-Pole, 240 V, Single Phase, Capacitor Start and Run (CSR), Capacitor Start and Capacitor Run (CSCR), Water Filled Submersible s for bore Size Minimum 100 mm and OD of 98 mm in the Operating Head Range for Checking the Non-overloading (CSR) Minimum Starting Torque(In terms of percentage of Full Load Torque) Minimum Starting Torque (In Terms of Percentage of Full Load Torque) kw A A percent percent (1) (2) (3) (4) (5) (6) 0.37 5.3 5.7 30 125 40.0 0.55 6.2 6.6 30 125 42.0 0.75 7.5 8.0 30 125 46.0 1.1 10.5 11.2 30 125 49.0 1.5 13.8 14.8 30 125 52.0 2.2 19.8 21.2 30 125 56.0 1 current limits specified are for 240 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage. 2 Values given in col. 3 are 1.07 times the values given in col 2. 3 For s of other ratings below 0.37 kw the performance values shall be declared by the manufacturer. 4 efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum overall efficiency of the pumpset. 4
Table 5 Values of Performance Characteristics for 2-Pole, 240 Volt, Single Phase Capacitor Start and Run (CSR), Capacitor Start and Capacitor Run (CSCR), Oil Filled/or Encapsulated Oil Filled, Submersible s for Bore Size Minimum 100 mm and OD of 98 mm in the Operating Head Range for Checking the Non-overloading (CSR) Torque(In terms of percentage of Full Load Torque) Torque(In Terms of Percentage of Full Load Torque) kw A A Percent Percent (1) (2) (3) (4) (5) (6) 0.37 4.1 4.4 30 125 43.0 0.55 5.0 5.3 30 125 45.0 0.75 6.7 7.1 30 125 50.0 1.1 9.5 10.1 30 125 53.0 1.5 12.5 13.3 30 125 56.0 2.2 16.0 17.1 30 125 62.0 1 current limits specified are for 240 V rated voltage. For other voltages, it shall be in inverse proportion to rated voltage. 2 Values given in col. 3 are 1.07 times the values given in col 2. 3 For motors of other ratings below 0.37 kw the performance values shall be declared by the manufacturer. 4 efficiency factors shall be applied for Fig. 4 and Fig. 5 to arrive the minimum overall efficiency of the pumpset. (Page 4, clause 8, sentence 2) Substitute the following for the existing sentence: The length of the cable shall be minimum 2m unless otherwise specified by the customer. (Page 8, clause 15.2.1, line 4) Substitute 20 m for 30 m. (Page 8, clause 15.2.1, line 5) Substitute whichever is of lesser range for which ever is less. (Page 8, clause 15.2.2) Insert the following new clause after clause 15.2.2: 15.2.3 The pumpset shall be tested at rated conditions and the maximum current consumption of the pumpset at the operating head range shall be verified. The actual verified current shall be more than the permissible limit of maximum current of next lower rating specified in col 3 of the Tables 1 to Table 5. NOTE The above clause is to ensure proper rating of pumpset (Page 8, clause 15.3, line 5) Substitute Tables 1, 2, 3, 4 and 5 for Table 1. [Page 8, clause 16.1 (n)] Delete with variation. [Page 8, clause 16.1 (q)] Insert CSR, CSCR after start/delta. (Page 8, clause 16.1 (t)) Insert the following at the end u) Category of motor. (Page 9, Fig. 4) Substitute the following for the existing figure: 5
5 1 The efficiency in figure represents three or more stages: a) For two stage pump, multiply efficiency given by a factor 0.98. b) For single stage pump, multiply efficiency given by a factor 0.97. 2 The motor efficiency factor of motor ratings not given in the Tables 1, 2, 3, 4 and 5 shall be as declared by the manufacturer. The motor efficiency factor of motors used with pumpsets suitable for bore sizes more than 200 mm shall be as declared by the manufacturer but it shall be not less than the motor efficiency factor of motors of same rating for 200 mm bore size. 3 For overall efficiency of the pumpset, multiply pump efficiency by corresponding motor efficiency factor as given in the Tables 1, 2, 3, 4 and 5. 4 The efficiency chart includes non-return valve losses. 5 of the pumpsets having declared duty points beyond the efficiency lines on either side may be declared by the manufacturer and applicable tolerance applied. Where the point lies in between the efficiency lines, the higher value be taken as minimum efficiency. FIG. 4 MINIMUM EFFICIENCY IN PERCENT FOR (2-POLE) SUBMERSIBLE PUMPSET 6
e (Page 10, Fig. 5) Substitute the following for the existing Fig. 5: (MED 20) S NOTE 1 The efficiency in figure represents three or more st ages: a) For two stage pump, multiply efficiency given by a factor 0.98. b) For single stage pump, multiply efficiency given by a factor 0.97. e 2 The motor efficiency factor of motor ratings not given in the Tables 1, 2, 3, 4 and 5 shall be as declared by the manufacturer. The motor efficiency factor of motors used with pumpsets suitable for bor sizes more than 200 mm shall be as declared by the manufacturer but it shall be not less than the motor efficiency factor of motors of same rating for 200 mm bore size. 3 For overall efficiency of the pumpset, multiply pump efficiency by corresponding motor efficiency factor as given in the Tables 1, 2, 3, 4 and 5. 4 The efficiency chart includes non-return valve losses. 5 of the pumpsets having declared duty points beyond the efficiency lines on either side may be declared by the manufacturer and applicable tolerance applied. Where the point lies in between th efficiency lines, the higher value be taken as minimum efficiency. FIG. 4 MINIMUM EFFICIENCY IN PERCENT FOR (2-POLE) SUBMERSIBLE PUMPSET Publication Unit, BIS, New Delhi, India 7