UNIMIX EM. Operations Manual. Supplied by:

Similar documents
Table of Contents. Table of Contents. Metalworking Lubricants. Specialty Tools. Metalworking Lubricants. Edge Breakers.

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

Agxcel GX12i Chemical Injection System

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

SINGLE ACTION FLUID PUMP

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Certo Chemical Dilution System

Heavy Duty Sprayer Owners Manual Model MS-O

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

Operating Manual. Model 0.4% Model 1% Model 2.5% Model 5% Model 10% Model 20% Fluid Flow Range: 0.03 gpm to 12 gpm* 7 lph to 2,700 lph*

Industrial Pumping Equipment PowerMaster III

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

Table of Contents. Introduction. KP1H Components... 2 Installation and Assembly

DEMA Pro-Fill I Sink Dispenser

STAINLESS STEEL DETERGENT INJECTOR AW

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

SUPER DUTY, INDEPENDENT DUAL SYSTEM HYDRAULIC POWER UNIT / DIESEL POWERED

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

DEMA Pro-Fill II Sink Dispenser

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

Multi-Tank Submersible Pump Install Manual

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

Spray Clean 606T-2 Installation Instruction

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

MAINTENANCE MANUAL DI 16

POMPE À DIAPHRAGME DIAPHRAGM PUMP ASYBCO

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Tools Needed for Mounting Cleá Filling Station

High Accuracy Mechanical Fuel meter FM-100

AGXCEL GX12i CHEMICAL INJECTOR 2% INJECTOR UNIT - PN# % INJECTOR UNIT - PN# E 6TH ST KEARNEY NE

SOLUTION STATION Instruction Manual

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

12 SERIES. Product Information. Performance & Specs. All 300 Series S.S. construction. Compact, easy to mount 11" x 9" x 3", weighs only 7lb. 2 oz.

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

PeroxiDraw Dispenser

PROMAX INSTRUCTION MANUAL

Spray & Foam Dispenser Item #

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

MMR20. Instruction Manual for Operation & Maintenance. IB International. Ph:

DI GPM Operating Manual

Installation & Design Maintenance for ILBP System

earth safe DEF Systems for Critical Power

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

CONCRETE CONTROLS CORPORATION 1311 N. CONGRESS DRIVE CHANDLER AZ FAX

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

THROUGH TOOL LUBRICATORS

SERVICING INSTRUCTIONS

FRP SystemOne GELCOATER OPERATION MANUAL. MAGNUM VENUS PRODUCTS Operation Manual. Part No. M Revision

PRESSURE WASHERS Davis Road, Suite J Elgin, IL (800) Professional 2018 Price List

M-3025CB-AV Fuel Pump

SPLASH On Tap Installation Guide

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

Warning and Safety Precautions

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

AIR OPERATED OIL PUMPS AND KITS

SV1217-SS SPRAY VALVE O P E R AT I N G M A N U A L

#9040 FUEL TANK SWEEPER

Installation, Operation and Maintenance Instructions

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

LG-60-3PT-WP-309-BL-TSC

OPERATORS MANUAL for Electric Pressure Washers

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS

AUTOGAS 150 SERIES PUMPS INSTALLATION GUIDELINES FOR UNDERGROUND TANK APPLICATIONS

Al- Ameen Engg. College. Fluid Machines. Prepared by: AREEF A AP/ ME AL AMEEN ENGINEERING COLLEGE Shoranur.

Low Profile J Series Power Unit with Vane Pump

Items # and #

Fact File 59 Extinguishing systems

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

Model &

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

1600 PSI ELECTRIC PRESSURE WASHER

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump:

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

OPERATOR S MANUAL SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

AIR OPERATED OIL PUMPS AND KITS

UNIVERSAL, INDEPENDENT DUAL SYSTEM HYDRAULIC TEST STAND

MODEL 872D MODEL 873N MODEL 872B POST-MIX BEVERAGE DISPENSER FOR USE WITH BAG-IN-BOX

Table of Contents WARRANTY

SAM SPARTAN ACCURATE MEASURE DISPENSING SYSTEM INSTALLATION INSTRUCTIONS MODEL 681-3SAM 1. PARTS: A. SAM

Full Range Pressure Compensating Variable Flow Control

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Purging Air From Divider Block Lubrication Systems

Transcription:

UNIMIX EM Operations Manual Supplied by:

UNIMIX OPERATING MANUAL The UNIMIX was developed to meet the needs of all metalworking shops for accurate, automatic coolant metering and mixing: a need not met by the familiar venturi mixers. The UNIMIX enables all shops to obtain the mixing accuracy possible only with a positive displacement proportioning pump. Application: The UNIMIX will provide accurate mixing of all types of coolant concentrates and dispenses coolant on demand at a consistent, user-selected concentration. Actuating Arm Toggle Lever Assembly Cover Water Inlet Outlet Concentration Adjustment Knob Upper Valve Screw Adjustment Locking Knob Chemical Ball Checks Water Motor Lower Valve Screw Chemical Pump Suction Tube

Principle of Operation: Water, under pressure, drives a reciprocating piston in the water motor cylinder. This piston in turn drives a piston in the concentrate metering cylinder which draws concentrate from the drum, meters the concentrate and injects it into the water from the water motor. Specifications & Utility Requirements: Water Temperature: 40 F (4 C) to 150 F (66 C) Note: For best results, most soluble oil coolants require mixing with water warmer than 65 F (18 C) Water Filtration: Water Pressure: Water Flow Rate: 10 Micron filtration required 30psi (2.1kg/cm2) minimum 60psi (4.2kg/cm2) maximum 2.0 US GPM (7.6 LPM) @ minimum pressure 7.0 US GPM (26 LPM) @ maximum pressure 5.0 US GPM (19 LPM) noted average flow Dimensions: 8 oz. E.M. 15-1/4" L* x 5-3/4" W x 7" H (387 mm L x 146mm W x 178mm H) 16 oz. S.S. 16" L* x 5-3/4" W x 7" H (406mm L x 146mm W x 178mm H) 32 oz. X.L. 17 1/2" L x 5 3/4" W x 7" H (445 mm L x 146 mm W x 178 mm H) *Required installation dimensions Mixture Range:** 1% to 3.5% (UNIMIX EM) 1% to 8% (UNIMIX SS) 2% to 15% (UNIMIX XL) ** The list dilution capabilities presume chemicals with the approximate viscosity of water. A substantial increase in viscosity and correspondingly increased friction loss will limit the proportioning abilities of a given model.

Installation Figure 1 1. Mount the proportioner on a bracket or using the four rubber feet provided with the machine (Figure 1). Do not tighten the rubber feet excessively. The rubber feet should be just snug. Over-tightening rubber feet will cause the end plates to crack. NOTE: THE BOTTOM OF THE BRACKET SHOULD BE 42 (1070 mm) FROM THE FLOOR. THIS WILL ALLOW A DRUM OF PRODUCT TO BE PLACED UNDER PROPORTIONER. 2. If deionized water is not used, connect a 10 micron water filter (available as an option) to the inlet fitting of the proportioner (Figure 2). If the inlet water pressure exceeds 60 psi (4.2 kg/cm2), a regulator must be installed in the inlet water line. NOTE: THE PROPORTIONER IS DESIGNED TO BE USED WITH 3/4" GARDEN HOSE CONNECTIONS FOR BOTH THE WATER INLET AND OUTLET. THE UNIT CAN BE CONNECTED WITH RIGID PIPE IF DESIRED. ALL NECESSARY HOSES AND PIPING MUST BE SUPPLIED. Figure 2 The proportioner must be installed in compliance with all local plumbing codes. The proportioner water feed line must be isolated to prevent chemical backflow through the proportioner. 3. Connect the pipe or line that will feed the mixture to a central reservoir or to the mixture use point, to the discharge side of the proportioner. If you are using pipe to make these connections, use a garden hose to NPT adapter. 4. Attach the suction tube to the chemical pump and place the bottom end of the tube into the drum of concentrate. The proportioner must be installed in compliance with all local plumbing codes. The proportioner water feed line must be isolated to prevent chemical backflow through the proportioner.

Machine Start-Up 1. Loosen the adjustment locking knob and turn the concentration adjustment knob to the maximum setting, position 10 (Figure 3). 2. Check all connections and fittings for proper tightness and turn on the water to the machine. NOTE: THE PLASTIC FITTINGS ON THE PROPORTIONER SHOULD ONLY BE HAND- TIGHTENED FOR PROPER SEALING. Figure 3 3. As water flows through the water motor of the proportioner, the actuating arm and piston at the rear of the proportioner will move back and forth. This shaft operates the chemical pump piston. The concentrate will start rising up the suction tube (Figure 4). 4. Once the product leaving the chemical pump reaches the main water stream, take a 1 gallon sample of the mixture for a concentration test using either a titration kit or a refractometer. Adjust the concentration adjustment knob as needed to give the desired product to water ratio. NOTE: The numbers on the graduated guide are reference marks only and do not represent any particular ratio. The #10 is the strongest concentration and the #0 is the weakest. Once the proper ratio is reached, hand-tighten the adjustment locking knob. Figure 4 Complete overhaul kits can be ordered through Eriez Hydroflow.

TROUBLESHOOTING Complaints 1. Water motor will not run. Causes A. Water turned off to unit. B. Water filter clogged. C. Discharge lines shut off or clogged. D. Proportioner stalled; proportioner operates intermittently-then stalls. Sluggish toggle switching action. Corrections A. Turn water on to unit. B. Remove filter element and replace with new filter. C. Check to be sure lines are clear and all system valves are open. D. Manually flip toggle arm. If Proportioner operates and valve assembly is undamaged, replace toggle lever spring. 2. Will not draw chemical. A. Water motor not working. B. Proportioner concentrate adjustment set on minimum. C. Pump head/valves dry. D. Upper or lower valve screws sucking air. E. Foreign material on valve seat. F. Excessive discharge back pressure. A. Check motor per item 1 above. B. Re-adjust. Set on Max. to Prime. C. Remove upper valve screw; fill cavity with water carefully replace and tighten valve screws. D. Tighten fittings-hand tighten only. E. Remove upper and lower valve screws, springs, spring retainers and ball checks. Rinse balls and clean ball seats. Reassemble pump head and tighten upper and lower valve screws. F. Relieve downstream back pressure until unit is primed.