H CHAPTER PAGES FISCHER TM SERIES RUGGED COMPACT LIGHTWEIGHT KEY FEATURES IP68 to -0m / IP69 / Hermetic 60 EMC shielding High corrosion resistance 0,000 mating cycles H -
FISCHER TM SERIES Table of contents H- / H-8 PAGES PLUGS CABLE MOUNTED Body styles (UP0-L; UP0-Q)... H - Technical dimensions... H -5 RECEPTACLES PANEL FRONT MOUNTED Body style (UP50)... H-6 Technical dimensions... H -7 CABLE MOUNTED Body style (UR50)... H-8 Technical dimensions... H-9 FOR ALL PANEL REAR MOUNTED Body styles (UR0; UR0)... H-0 Technical dimensions... H - PANEL FRONT MOUNTED Body style (UR0)... H-0 Technical dimensions... H- selection... H - Electrical & contact configurations... H - Options - Mechanical coding... H -8 PCB hole layout... H -9 Part numbering... H - Accessories... H - Tooling... H -6 Technical information... H -7 This catalog covers our standard connector solutions. For specific requests, including hybrid or custom connectors, please contact your local sales representative. H - Technical Specifications
selection FISCHER TM SERIES AVAILABLE SIZES CONNECTOR SIZE VERSUS CABLE DIAMETER Min cable ø Max cable ø Number of contacts 07.7.9-0 08.5 7.5-9 5.7 8.9 8-9 5.7.9 5-7 8 5.7.9 mm 00 50 0 Images of available sizes are on : scale when printed full size on A paper. H -
FISCHER TM SERIES Body styles PLUGS CABLE MOUNTED Body style UP0 References to detailed information Protection Locking system s Housing color Design Cabling Accessories Sealed up to IP68 Hermetic Friction Push-pull Quick-release Lanyard Tamperproof Crimp Solder Anthracite Black Shortened body Straight Right-angle Cable clamp sets Overmoldable Heat shrinkable Cable bend reliefs Protective sleeves Sealing caps 07 08 8 Sealing categories, page A-6 Locking systems, page A-5 Electrical & contact configurations, pages H- to H-7 Part numbering, page H- Body styles, chapter H Accessories, page H- Technical dimensions, page H-5 For more information visit our website www.fischerconnectors.com/technical H - Technical Specifications
Technical dimensions FISCHER TM SERIES PLUGS CABLE MOUNTED UP0 BODY STYLE øc ød ) ød ~B ~A A B øc ød ød max Torque 07 8.0 8.0.0 9.0.5 8.5 Nm 08 9.0 5.0 5.0 0.5.5 0.5 Nm 9.5 6.0 8.5.7 7..0 Nm 50.0.0.7 6.0 8.7 7.5 Nm 8 58.0 8.0 9.0.7.7 6.0 Nm ) Max. cable diameter below shield. All dimensions and images shown are in millimeters and are for reference only. H - 5
FISCHER TM SERIES Body styles PLUGS PANEL FRONT MOUNTED Body style UP50 References to detailed information Protection Locking system s Housing color Design Assembly Accessories Sealed up to IP68 Hermetic Friction Push-pull Quick-release Lanyard Tamperproof Crimp Solder Anthracite Black Shortened body Straight Right-angle Front-mounting Rear-mounting Cable bend reliefs Protective sleeves Sealing caps Sealing categories, page A-6 Locking systems, page A-5 Electrical & contact configurations, pages H- and H-5 Part numbering, page H- Body styles, chapter H Accessories, page H- 07 Technical dimensions, page H-7 For more information visit our website www.fischerconnectors.com/technical H - 6 Technical Specifications
M Technical dimensions FISCHER TM SERIES PLUGS PANEL FRONT MOUNTED UP50 BODY STYLE E max øc B H A A B øc E H M Torque 07 0.0 5..0.5.0 9x0.5 9. Nm. 7.6.8.5.0 6x 7 9.5 Nm Top f øg 07 8.0 9..5 6. +0. f øg 0+0. 0 Panel cut-out PANEL CUT-OUT All dimensions and images shown are in millimeters and are for reference only. H - 7
FISCHER TM SERIES Body styles RECEPTACLES CABLE MOUNTED Body style UR50 References to detailed information Protection s Housing Design Cabling Accessories Sealed up to IP68 Hermetic Crimp Solder Anthracite Black Shortened body Straight Right-angle Cable clamp sets Overmoldable Heat shrinkable Cable bend reliefs Protective sleeves Sealing caps 07 08 Sealing categories, page A-6 Electrical & contact configurations, pages H- to H-6 Part numbering, page H- Body styles, chapter H Accessories, page H- Technical dimensions, page H-9 For more information visit our website www.fischerconnectors.com/technical H - 8 Technical Specifications
Technical dimensions FISCHER TM SERIES RECEPTACLES CABLE MOUNTED UR50 BODY STYLE ød ) ød øc ~L øc ød ø dmax L Torque 07.0 0.0.5 7 8.5 Nm 08 5.0.0.5 9 0.5 Nm 8.5 5.5 7. 9.0 Nm.7 7.9 8.7 50 7.5 Nm ) Max. cable diameter below shield. All dimensions and images shown are in millimeters and are for reference only. H - 9
FISCHER TM SERIES Body styles RECEPTACLES PANEL MOUNTED Body style UR0 UR0 UR0 Protection s Housing color Design Assembly Accessories Sealed up to IP68 Hermetic Crimp Solder PCB Anthracite Black Right-angle Flush Front-projecting Bulkhead feedthrough Front-mounting Rear-mounting Sealing caps Spacers Color-coded washers Grounding washers Locking washers 07 08 8 References to detailed information Electrical & contact configurations, page H- to H-7 Part numbering, page H- Body styles, chapter H Accessories, page H- Technical dimensions, page H- and H- For more information visit our website www.fischerconnectors.com/technical H - 0 Technical Specifications
Technical dimensions FISCHER TM SERIES RECEPTACLES PANEL REAR MOUNTED* UR0 BODY STYLE ø0.7 E max M UR0 BODY STYLE ø0.7 E max M øc øc I H A I ød B H A A øc E H I M Torque 07..0.5.0 0.7 0x0.5 TC00.007.5 Nm 08 8.7 6.9 5.0.0.0 x 5 TF00.00.5 Nm 8.7.8 7.0.0.0 6x 7 TK00.00.5 Nm.5.8 5.5.0.0 8x 0 TP00.0 6.0 Nm 8 9..8 7.5.0.0 5x 7 TQ00.005 0.0 Nm A B øc ød E H I M Torque 07 6.5 0.7.0.0.5.5 0.7 9x0.5 TC00.000. Nm 08 8.0.7 6.9.0.0.0.0 x 5 TF00.00.5 Nm 8.0.7.8 8.8.0.0.0 6x 7 TK00.00.5 Nm 0.5 6.0.8 0.0 5.0.0.0 8x 0 TP00.0 6.0 Nm 8.0..8 6.0 5.0.0.0 5x 7 TQ00.005 0.0 Nm f øg Top f øg Top 07 9. 0. 07 8.0 9. 08 0.9..5 6. +0. f øg 0+0. 0 08 0.9..5 6. +0. f øg 0+0. 0 6.5 8. 8. 5. Panel cut-out PANEL CUT-OUT 6.5 8. 8. 5. Panel cut-out PANEL CUT-OUT * Standard version with PCB contacts and grounding pin. For solder contact version, a special solder ground contact pin is included for AWG[7/0]. All dimensions and images shown are in millimeters and are for reference only. H -
FISCHER TM SERIES Technical dimensions RECEPTACLES PANEL FRONT MOUNTED* UR0 BODY STYLE M E max ØD ØC B ~L H A A B øc ød E H L M Torque 07 7.7 6..0 0.0.5.5 0 9x0.5. Nm 08.7 7.0 6.9.5.0.0 7 x 5.5 Nm. 7.6.8 5.0.6.0 9 6x 7 9.5 Nm f øg Top 07 8.0 9. 08 0.9..5 6. +0. f øg 0+0. 0 Panel cut-out PANEL CUT-OUT * Standard version with solder contacts. H - Technical Specifications
Electrical & contact configurations FISCHER TM SERIES SIZE 07 Pin layout Layout reference Number of contacts diameter [mm] Solder contacts ) Wire size ) Crimp contacts ) PCB contacts Pin diameter [mm] Current rating [A] IEC 605-5--5b ) Rated voltage r.m.s [V] IEC 6066-5) to body Test voltage [kv] in mated position AC r.m.s. IEC 605-- Test a to contact to body DC to contact 00 0.9 00 0.9 max ø0.79mm AWG [] AWG [7/0] max ø0.79mm AWG [] AWG [7/0] 6) max ø0.8mm min ø0.8mm AWG-6 0.6 9. 50..7.8. - 0.6 8. 50...8.6 00 0.7 max ø0.79mm AWG [] AWG [7/0] max ø0.6mm min ø0.8mm AWG-8 0.50 5.5 00...7.8 07 005 5 0.7 max ø0.79mm AWG [] AWG [7/0] max ø0.6mm min ø0.8mm AWG-8 0.50 5. 60 0.8.0..8 007 7 0.5 max ø0.mm AWG6 [] AWG8 [9/0] max ø0.mm min ø0.0mm AWG8-0.0.0 60 0.8.0..8 ) Stranding values are in brackets. 009 9 0.5 00 0 0.5 max ø0.mm AWG6 [] AWG8 [9/0] max ø0.mm AWG6 [] AWG8 [9/0] - 0.0. 60 0.8...8-0.0. 60 0.8 0.9.. ) See dedicated crimping instructions document for further information. ) For a given AWG, the diameter of some stranded cable designs could be larger than the hole diameter of the barrel. Testing may be required. ) Current per contact at 0 C temperature rise measured on the basic curve according to IEC 605-5--5b. For maximum operating current, a reduction factor must be used and limitations due to the size of the wires and the permissible upper temperature limit of the materials employed must be taken into account. See page A for details. 5) Recommended operating voltage at sea level. This rated voltage is a general guideline where no other electrical safety standard applies. In cases where other standards rule a specific use of the connector, the application-specific safety criteria shall be considered first. This must be evaluated in the framework of equipment engineering. 6) Standard polarity only. All dimensions and images shown are in millimeters and are for reference only. H -
FISCHER TM SERIES Electrical & contact configurations SIZE 08 Wire size ) PCB contacts Current rating [A] Rated voltage r.m.s [V] Test voltage [kv] in mated position IEC 605-- Test a Pin layout Layout reference Number of contacts diameter [mm] Solder contacts ) Crimp contacts ) Pin diameter [mm] IEC 605-5--5b ) IEC 6066-5) to body AC r.m.s. to contact to body DC to contact 00 0.9 00 0.9 max ø0.79mm AWG [] AWG [7/0] max ø0.79mm AWG [] AWG [7/0] - 0.70 9. 50..7.8. - 0.70 8. 50...8.6 08 00 0.7 005 5 0.7 max ø0.79mm AWG [] AWG [7/0] max ø0.79mm AWG [] AWG [7/0] max ø0.6mm min ø0.8mm AWG-8 max ø0.6mm min ø0.8mm AWG-8 0.50 5.5 00...7.8 0.50 5. 60 0.8.0..8 ) Stranding values are in brackets. 007 7 0.5 009 9 0.5 max ø0.mm AWG6 [] AWG8 [9/0] max ø0.mm AWG6 [] AWG8 [9/0] - 0.0.0 60 0.8.0..8-0.0. 60 0.8...8 ) See dedicated crimping instructions document for further information. ) For a given AWG, the diameter of some stranded cable designs could be larger than the hole diameter of the barrel. Testing may be required. ) Current per contact at 0 C temperature rise measured on the basic curve according to IEC 605-5--5b. For maximum operating current, a reduction factor must be used and limitations due to the size of the wires and the permissible upper temperature limit of the materials employed must be taken into account. See page A for details. 5) Recommended operating voltage at sea level. This rated voltage is a general guideline where no other electrical safety standard applies. In cases where other standards rule a specific use of the connector, the application-specific safety criteria shall be considered first. This must be evaluated in the framework of equipment engineering. H - Technical Specifications
Electrical & contact configurations FISCHER TM SERIES SIZE Wire size ) PCB contacts Current rating [A] Rated voltage r.m.s [V] Test voltage [kv] in mated position IEC 605-- Test a Pin layout Layout reference Number of contacts diameter [mm] Solder contacts ) Crimp contacts ) Pin ø [mm] IEC 605-5--5b ) IEC 6066-5) to body AC r.m.s. to contact to body DC to contact 008 8 0.7 max ø0.79mm AWG [] AWG [7/0] max ø0.6mm min ø0.8mm AWG-8 0.50. 50.7.8..6 0 0.7 06 6 0.5 max ø0.79mm AWG [] AWG [7/0] max ø0.mm AWG6 [] AWG8 [9/0] 6) 7) max ø0.6mm min ø0.8mm AWG-8 0.50. 50.6.6.6. - 0.0 6).7 50. 0.9.0.5 09 9 0.5 max ø0.mm AWG6 [] AWG8 [9/0] - 0.0 6).5 50. 0.9.0.5 ) Stranding values are in brackets. ) See dedicated wire gauge crimping instructions document for further information. ) For a given AWG, the diameter of some stranded cable designs could be larger than the hole diameter of the barrel. Testing may be required. ) Current per contact at 0 C temperature rise measured on the basic curve according to IEC 605-5--5b. For maximum operating current, a reduction factor must be used and limitations due to the size of the wires and the permissible upper temperature limit of the materials employed must be taken into account. See page A for details. 5) Recommended operating voltage at sea level. This rated voltage is a general guideline where no other electrical safety standard applies. In cases where other standards rule a specific use of the connector, the application-specific safety criteria shall be considered first. This must be evaluated in the framework of equipment engineering. 6) Not valid for UP50. 7) UR0x: standard polarity only. All dimensions and images shown are in millimeters and are for reference only. H - 5
FISCHER TM SERIES Electrical & contact configurations SIZE Wire size ) PCB contacts Current rating [A] Rated voltage r.m.s [V] Test voltage [kv] in mated position IEC 605-- Test a Pin layout Layout reference Number of contacts diameter [mm] Solder contacts ) Crimp contacts ) Pin ø [mm] IEC 605-5--5b ) IEC 6066-5) to body AC r.m.s. to contact to body DC to contact 8). max ø.8mm AWG9 [9/] -.8 6 0..7 0 0.7 max ø0.79mm AWG [] AWG [7/0].7-0.5 0..7. 0 8).6 0.7 max ø.86mm AWG [] AWG [7/] max ø0.79mm AWG [] AWG [7/0] -.5 6 0.6.6.6-0.5 0.6.6. 07 7 0.5 6) max ø0.mm AWG6 [] AWG8 [9/0] 7) max ø0.mm min ø0.0mm AWG8-0.0 6).0 00. 0.5.8 0.5 ) Stranding values are in brackets. ) See dedicated wire gauge crimping instructions document for further information. ) For a given AWG, the diameter of some stranded conductor designs could exceptionally be larger than the hole diameter of the barrel. Testing may be required. ) Current per contact at 0 C temperature rise measured on the basic curve according to IEC 605-5--5b. For the max. operating current a reduction factor must be used and limitations due to the size of the wires and the permissible upper temperature limit of the materials employed must be taken into account. See page A for details. 5) Recommended operating voltage at sea level. This rated voltage is a general purpose guideline where no other electrical safety standard applies. In cases where other standards rule a specific use of the connector, the application-specific safety criteria shall be considered first. This must be evaluated in the framework of equipment engineering. 6) UR0x: standard polarity only. 7) Only valid for UP0, UR50. 8) block with male contacts comes standard with advanced power contacts. H - 6 Technical Specifications
Electrical & contact configurations FISCHER TM SERIES SIZE 8 Wire size ) PCB contacts Current rating [A] Rated voltage r.m.s [V] Test voltage [kv] in mated position IEC 605-- Test a Pin layout Layout reference Number of contacts diameter [mm] Solder contacts ) Crimp contacts ) Pin ø [mm] IEC 605-5--5b ) IEC 6066-5) to body AC r.m.s. to contact to body DC to contact 8 08 6) 0.7 - max ø0.6mm min ø0.8mm AWG-8 0.50.0 50.5.5..5 ) Stranding values are in brackets. ) See dedicated wire gauge crimping instructions document for further information. ) For a given AWG, the diameter of some stranded cable designs could be larger than the hole diameter of the barrel. Testing may be required. ) Current per contact at 0 C temperature rise measured on the basic curve according to IEC 605-5--5b. For maximum operating current, a reduction factor must be used and limitations due to the size of the wires and the permissible upper temperature limit of the materials employed must be taken into account. See page A for details. 5) Recommended operating voltage at sea level. This rated voltage is a general guideline where no other electrical safety standard applies. In cases where other standards rule a specific use of the connector, the application-specific safety criteria shall be considered first. This must be evaluated in the framework of equipment engineering. 6) Standard polarity only. All dimensions and images shown are in millimeters and are for reference only. H - 7
FISCHER TM SERIES Options MECHANICAL CODING Code Code Code Code Code Code Code Code 07 07 PLUGS 08 RECEPTACLES 08 8 8 Visual coding Visual coding H - 8 Technical Specifications
PCB hole layout FISCHER TM SERIES POLARITY BODY STYLES UP0 UP50 UR0 UR0 F F F F POLARITY Standard polarity : male contacts on plug / female contacts on receptacle Inverted polarity : female contacts on plug / male contacts on receptacle. WARNING : for high-current applications, make sure to choose the correct polarity (female contacts on device that is supplying the power) UR0 F F UR50 PCB / PIN LAYOUT View from F ) Polarity Number of contacts (layout reference ) (00) (00) (00) 5 (005) 7 (007) 9 (009) 0 (00) 07 Standard ø. 5.5 ø0.8 0 (x) ø. ø0.8 60 5.5 ø.6 90 (x) 5 ø0.65 5.5 7 (5x) 6 ø.9 5 ø0.65 5.5 60 (6x) 7 0 6 5 ø0.55 ø 5.5 ø. 5 (8x) 9 8 7 6 5 ø0.55 0 5.5 ø.5 ø.8 5 (x) 0 9 5 8 6 7 ø0.55 (6x) 5.5 Inverted 5 7 6 5 9 8 7 6 5 0 9 8 5 7 6 ) Recommended PCB hole dimensions may be adjusted to application. a) For optional ground pin. All dimensions and images shown are in millimeters and are for reference only. H - 9
FISCHER TM SERIES PCB hole layout PCB /PIN LAYOUT View from F ) Polarity Number of contacts (layout reference) (00) (00) (00) 5 (005) 7 (007) 9 (009) Standard ø. 6.0 ø0.85 0 (x) ø. ø0.85 60 6.0 08 ø.6 90 (x) 5 ø0.65 6.0 7 (5x) 6 ø.9 5 ø0.65 6.0 60 (6x) 7 0 6 5 ø0.55 ø 6.0 ø. 5 (8x) 9 8 7 6 5 ø0.55 0 6.0 Inverted 5 7 6 5 9 8 7 6 5 Polarity Number of contacts (layout reference) 8 (008) (0) 6 (06) 9 (09) Standard ø0.65 5 5 8 7 6 ø5. 8. ø. 5 6 7 8 ø0.65 0 60 0 9 0 ø5. 8. ø.9 ø0.55 7 8 9 0 8 7 6 6 6 5 5 ø5.6 8. ø.9 60 5 0 9 9 8 7 8 6 0 7 5 6 5 ø0.55 ø5.6 8. Inverted 7 8 6 5 6 7 9 8 5 5 8 6 8 7 9 7 6 5 0 6 9 6 5 0 7 9 8 0 5 ) Recommended PCB hole dimensions may be adjusted to application. a) For optional ground pin. H - 0 Technical Specifications
PCB hole layout FISCHER TM SERIES PCB /PIN LAYOUT View from F ) Polarity Number of contacts (layout reference) + (0) + (0) 7 (07) Polarity Number of contacts (layout reference) (0) Standard ø6.0 ø.5 0 0 5 ø.9 a) 9.0 ø.95 ø0.65 ø6 ø.5 5 ø.6 a) 60 6 0 9.0 ø.65 ø0.65... ø0.55 9 5 0 7. = =. 5 0 6 5.. 0. 8 9.0 Standard.5.7 0.9 ø0.65 8..6 5 9 6 7 8 5.8.8.6 5..0 Inverted 5 6 5 5 0 6 5 9 5 0 7 Inverted 6 5 9 8 5 8 7 ) Recommended PCB hole dimensions may be adjusted to application. ) For optional ground pin. All dimensions and images shown are in millimeters and are for reference only. H -
FISCHER TM SERIES Part numbering PLUGS & RECEPTACLES Connector Design Block Housing Standard options Example: UP0 L 07 M 00 S BK Z Z B UR0 W F 0 S BK E A A Housing Material A = ALUMINUM B = BRASS (Standard) Body style UltiMate Plug = UP UP0 = Cable mounted UP50 = Panel mounted UltiMate Receptacle = UR UR0 = Panel rear mounted low profile UR0 = Panel rear mounted UR0 = Panel front mounted low profile UR50 = Cable mounted Sealing level Panel mounted : V = Vacuum sealing W (IP68/69) = Water sealing N = Non sealing Cable mounted : Not applicable = Nothing Locking system Grounding Panel mounted : A = Grounding pin (for UR0/UR0) N = None (for UR0/UP50) Insulator Material = PBT, 08///8 O-ring material Receptacle : O-ring at plug interface E = Standard (FVMQ) Keying code Code = Code = Standard keying = Code Housing color BK = Standard (Anthracite) Cable mounted : Z = Not applicable = PEEK. 07 only Plug : Z = Not applicable Code = Code = Standard guide mark = White H - Cable mounted plug : L = Push-pull locking Q = Quick release Cable mounted receptacle : Z = Not applicable Panel mounted : No locking = Nothing Connector size 07 = 07 08 = 08 = = 8 = 8 Technical Specifications Type S = Solder P = PCB C = Crimp Layout references 07 : 00, 00, 00, 005, 007, 009, 00 08 : 00, 00, 00, 005, 007, 009 Polarity of contacts M = Male contacts : 008, 0, 06, 09 : 0, 0, 07 8 : 0 F = Female contacts Standard polarity : Male contacts in plug, female contacts in receptacle
Accessories FISCHER TM SERIES BEND RELIEF Top performance, no hassle No tool required : 5 steps to assemble Clean cut : perfectly adjust the bend relief to your cable diameter with a simple blade CUTTING DIAMETERS Uncut Level Level Level Level Part Number 07 ø.9 ø.9 ø.9 ø.9 - UB07 ABK 08 ø.5 ø.7 ø5.7 ø7.5 - UB08 ABK Long lasting Resists 0,000 flex cycles at a 90 angle Operating temperature -55 C to +5 C ø.9 ø5. ø6.9 ø8.9 - UB ABK ø6.9 ø8.9 ø0.9 ø.9 - UB ABK 8 ø6.9 ø8. ø0. ø.9 ø.9 UB8 ABK UV resistant LEVEL Standard color is black (BK) Also available in grey (GY), blue (BL), yellow (YL), green (GN), violet (VT) upon request. Please contact your Fischer Connectors sales representative. All dimensions and images shown are in millimeters and are for reference only. H -
FISCHER TM SERIES Accessories SOFT CAPS - LANYARD WITH NYLON THIN CORD FIGURE A ø ~L Crimp ferrule and heat shrink tube are included. ød FIGURE A ø ~L Crimp ferrule and heat shrink tube are included. ød FIGURE A ø ~L Crimp ferrule and heat shrink tube are included. ød H - Technical Specifications
Accessories FISCHER TM SERIES SOFT CAPS - LANYARD WITH NYLON THIN CORD FIGURE ~L ød ød ød A 0.5 07 Plug Receptacle A D L d D Part number Fig. UP0 UP50 UR0 UR0 UR0 UR50 8.5.0 00 - - UCP07C A A00 6.0.0 00 - - UCR07C A A00.8.0 00 - - UCP07P A A00 6.0.0 95 0 UCR07P A A095..6 00 - - UCP08C A A00 08 9.9.6 00 - - UCR08C A A00 9.9.6 95 6 UCR08P A A095.0 7.6 00 - - UCPC A A00 9. 7.6 00 - - UCRC A A00 9. 7.6 95 6 UCRP A A095 5.0 0.7 00 - - UCPC A A00.5 0.7 00 - - UCRC A A00.5 0.7 95 8 UCRP A A095 8 9.5 8.7 00 - - UCP8C A A00 5.0 8.7 95 5 9 UCR8P A A095 Recommended for optimal sealing. Compatible but not recommended for optimal sealing. All dimensions and images shown are in millimeters and are for reference only. H - 5
FISCHER TM SERIES Tooling SPANNER & NUT DRIVER DOUBLE-ENDED OPEN SPANNER EXTRA THIN OPEN SPANNER EXTRA THIN NUT DRIVER WITH T-HANDLE AND HEX DRIVE ø D Part number Opening across flats Length Fork thickness TX00.008 8 96. TX00.009 9 0.5 TX00.00 0 0.5 TX00.0.5 TX00.0 0.0 Material Chrome Alloy Steel, Chrome plated, Fork Angles 5 and 75. Part number Opening across flats Length Fork thickness TX00.05 5 5 5. TX00.07 7 60 5.5 TX00.09 9 75 6.0 TX00.00 0 75 6.0 TX00.0 96 6.5 TX00.07 7 0 7. Material Chrome Vanadium Steel, Chrome plated, Fork Angle 5. Part number Thread size Nut outer dia. D Hex drive TC00.000 M9 x 0.5 5 7 TC00.007 M0 x 0.5 6 7 TF00.00 M x 5 8 0 TK00.00 M6 x 0 TP00.0 M8 x 6 TP00.005 M0 x 5 8 Material Hardened Tool Steel, Nickel plated. H - 6 Technical Specifications
Technical information FISCHER TM SERIES MATERIAL & SURFACE TREATMENT Components Spring sleeve (plug), shell (plug), Mounting nut (receptacle) ), bodies (all) Back nut (plug & cable mounted receptacle), Mounting nut (receptacle) ) Ground contact s - Male, ground pin - Female Aluminum AlMgSiSnBi Brass CuZn9Pb Aluminum AlMgSiSnBi Brass CuZn9Pb Brass CuZn9Pb Material Finish Designation ISO Standard Designation Standard Brass ; CuZn9Pb Bronze ; CuSnZnPb EN-AW-60 Anthracite Nickel SAE-AMS-QQ-N-90 SAE-AMS 0 CW6N UNS C 8500 EN-AW-60 Nickel SAE-AMS-QQ-N-90 SAE-AMS 0 CW6N UNS C 8500 CW6N UNS C 8500 CW6N ; UNS C 8500 CW56K ; ASTM B 9 UNS C 500 Nickel SAE-AMS-QQ-N-90 SAE-AMS 0 µm Gold over Nickel MIL-DTL-50D Type I ; ASTM B88 Insulator and sealing International symbol Flammability Insulator - Molded PBT, PEEK ) UL 9 V-0 Inner sleeve - Cable connectors POM UL 9 HB - «V» Vacuum sealed connectors Bi-component Epoxy compound UL 9 HB Sealant materials - «W» Water sealed connectors Silicon compound UL 9 V-0 Bend relief - Cable connectors Santoprene TM TPV 0-6 UL 9 HB Soft caps Material Flammability Cap TPV (Santoprene TM ) UL 9 HB Cord Nylon - Fixing lug Black Chrome plated brass (ISO CuZn7) Crimp ferrule Nickel plated copper - - O-rings International symbol Chemical name General FPM (Viton ) Fluoro elastomer Interface FVMQ Fluorosilicone rubber ) For UR0 & UR0. ) For UR0 & UP50. ) PBT for 08,, and 8 only. PEEK for 07 only. All dimensions and images shown are in millimeters and are for reference only. H - 7
FISCHER TM SERIES Technical information ENVIRONMENTAL & MECHANICAL DATA Characteristic Performance Standard Sealing performance mated and unmated IP68/IP69 m submersion for h ) IEC 6059 "V" sealing level : Hermetic : Tested : <0-8 mbar l/sec. IEC 60068--7 Test Qk, Method Sealing performance soft caps IP68, m submersion for hours; IP69; IEC 6059 Operating temperature range -55 C to +5 C ) IEC 605-6- i+j ; IEC 60068---Nb Corrosion resistance ) Salt mist,,000 hours, 5% salt solution, 5 C ; IEC 60068-- Test Ka; MIL-STD-0 Method 0 ; EIA-6-6 Endurance 0,000 mating cycles IEC 605-9-; EIA-6-09 Vibration, random ( 08,,, 8) 7.80 Grms, MIL-STD-0 Method A Condition I ; EIA-6-8 Condition V Vibration ( 07) 0 to,000 Hz,.5 mm or 5g, sweep cycles per axis, 0 minutes per 0-,000-0 Hz sweep cycle, no discontinuity > us ; MIL-STD-0 Method 0 Condition B Shock 00g amplitude, half sine pulse of ms, no discontinuity > µs MIL-STD-0 Method ; EIA-6-7 ) 0m/h or other depth/duration requirements available on request, please contact your local sales office. ) Temperature range of -0 C to +5 C for cable connectors overmolded with TPU material. Max. temperature of +85 C for soft caps. ) Plug and receptacle in mated position or with cap when unmated. For Brass connectors only. Aluminum version not recommended for Marine use. Preserved mechanical and electrical functionality. Visual aspect might be altered. ELECTRICAL DATA DATA TRANSMISSION Characteristic size Typical values resistance over 0,000 mating cycles Ø 0.5 mm Ø 0.7 mm Ø 0.9 mm Ø.6 mm Ø. mm 5.0 mω 5.0 mω.0 mω.5 mω.5 mω Standard IEC 605---a IEC 605---b Shell resistance ) < 5.0 mω IEC 605--6-f Insulation resistance > 0 0 Ω IEC 605---a Method C Shielding effectiveness 5) > 55 db up to GHz, IEC 605-- ) Measurement points on Figure. 5) 08 connector pair. < 5mΩ < 5 mω Protocol Number of contacts required USB.0 yes USB.0 9 application dependent 6) Ethernet Cat 5e (Gb/s) 8 yes TM 9 yes The data transmission performance of the Fischer UltiMate Series has been tested for most popular protocols that are used in a variety of applications today. 6) Test with your application to confirm acceptable functionality Figure H - 8 Technical Specifications