MOULDED CASE CIRCUIT BREAKERS 16A TO 630A

Similar documents
Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2

Molded Case Circuit Breaker

The Ultimate Safety Breaker

OPERATING CHARACTERISTICS

MCCB Connections, mounting and chassis systems

15-I73E CAT REF.

14-I73E CAT REF.

Low voltage circuit breakers

OUR CUSTOMER CARE COMMITMENTS

Compact NR630. NR100F to NR630F

12-I73Eb CAT REF.

MCCB Accessories to suit AF

Low breaking capacity moulded case circuit breakers

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Moulded Case Circuit Breakers

01 Spectra Plus - Introduction

Catalogue No. 10!64E.

3VF3 to 3VF8 Circuit-Breakers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Protection, Monitoring and Control Components for Low Voltage Equipment SELECTION GUIDE: UK EDITION

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Molded Case Circuit Breakers H series General information

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E

Key features. DESIGNS: - Conservator type - Hermetically sealed

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Motor Circuit Breakers C4

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

S: With magnet. Bore x stroke (basic type) Cushion P: pneumatic adjustable

D509E. Manual Motor - Starters

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

NS Feeder pillar up to 3200A

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20EJ

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

Operation and Maintenance Manual

MOULDED CASE CIRCUIT BREAKERS BC160N

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

18-I73E CAT REF.

Moulded case circuit breakers

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Series KTU7 UL489 Molded Case Circuit Breakers

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown

Series KTU7 UL489 Molded Case Circuit Breakers

World Super Series WSS The extensive breaker series from Mitsubishi Electric

C1251N DC and C1251N 1000 V

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Masterpact. Dimensions and connection. Masterpact NT06 to NT16 Fixed 3/4-pole device 54 Drawout 3/4-pole device 58

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

ype UP T Busplugs Low Voltage Switchboard Equipment

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Introduction. Installation. A Series Lighting Control Panelboards. DEH41081 Installation Instructions

GE Consumer & Industrial Power Protection. Record SL. Moulded Case Circuit Breakers Standard Line. GE Imagination at work

ACW Molded-Case Circuit Breaker UL 489 Listed

Memshield - ACB Ratings & Specifications

max pole for t=15 ms

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Intelligent Choice for Prestigious Buildings

3VU13, 3VU16 Circuit-Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Volt- and ammter switches / Position indicators

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Molded Case Circuit Breakers Solid-state trip types

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Low-voltage switchgear MNS Light W. Installation, handling and operation. ABB LV Systems

TECHNICAL SPECIFICATIONS OF PCC PANEL

3VT Kompaktleistungsschalter bis 630A

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Circuit Breakers Ex9M

Terasaki (Europe) Ltd

An innovative technology

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

MCCB Plug-in Chassis Type HBC

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Phase + Neutral, neutral on left side

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

MOULDED CASE CIRCUIT BREAKERS BC160N

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Power Distribution and Protection

Magnetic and Hydraulic-Magnetic Circuit Breaker

Phase + Neutral, neutral on right side

ACW Molded-Case Circuit Breaker UL 489 Listed

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Record SL. Moulded Case Circuit Breaker

Molded Case Circuit Breakers Earth Leakage Circuit Breakers. Mitsubishi Molded Case Circuit Breakers and Earth Leakage Circuit Breakers

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

Magnetic and Hydraulic-Magnetic Circuit Breaker

Motor Circuit Breakers C3

Wall mounted switchgear

LSIS UL MCCB & Accessory

Transcription:

TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions* S125-NF, S160-NF 93 E125-NJ, S125-NJ, S125-GJ 94 S160-NJ, S160-GJ, E250-NJ, S250-NJ, S250-GJ 96 H125-NJ, L125-NJ, H160-NJ, L160-NJ, S250-NE, H250-NJ, H250-NE, L250-NJ 98 E400-NJ, S400-CJ, S400-NJ, S400-GJ, S400-NE, S400-GE 100 H400-NJ, H400-NE, L40-NJ, L400-NE 102 E630-NE, S630-CE, S630-GE 104 Operating Handles 106 Terminal Covers 111 Interpole Barriers 113 Terminal Blocks for Front-Connected and Rear-Connected MCCBs 114 Slide Interlocks 115 Link Interlocks 118 Wire Interlocks 122 Position of Trip Button 126 External Neutral CT, Door Flanges 127 TEMBREAK MOULDED CASE CIRCUIT BREAKERS 630A TO 160A 8. TemBreak Moulded Case Circuit Breakers 9. Order Codes *Not to scale. The Ultimate Safety Breaker page 92

S125-NF, S160-NF. page 93 The Ultimate Safety Breaker

8 DIMENSIONS E125-NJ, S125-NJ, S125-GJ, S125-NN. 3P H L 4P Interpole barrier (removable) H L Mounting hole 134 155 47 Operating knob C L 154 Front panel t2 24 M8 screw Preparation of conductor ø9 17(max.) max.t5 8.5(max.) 3P HL Drilling plan 4P HL 132 17 8.5 Panel hinge position (hatching area) bottom view HL 154±1 60 90 14.5 21.5 90 30 30 30 45 75 10 Connector plug 5.5 45 28(max.) 164.5 106 45 61 8 M4x0.7 Mounting screw 30 30 M4x0.7 Tapped hole 100 200 150100 150 200 Operating knob 155 148 C L 154 Front panel t2 Mounting plate (max. t3.2) 5 15 Conductor overlap max. 134 90 86 HL 61 103.5 C L 3P HL Drilling plan 4P HL 132 134 C L Panel cutout (Front view) 4P 3P HL R1 155 Pad lock Connector plug 5.5 45 28(max.) 164.5 61 106 ø8.5 15 52 102 15 16 30 30 Stud can be turned 45 or 90 30 M4X0.7 Mounting screw 30 30 ø18 60 30 30 30 M4X0.7 Tapped hole 45 90 Panel cutout dimensions shown give an allowance of 1.5mm around the handle escutcheon. The Ultimate Safety Breaker page 94

E125-NJ, S125-NJ, S125-GJ, S125-NN. Plug-in Versions. Termination of Busbar Support or rail Preperation of conductor 10 (max.) 15 (max.) 6.5 5 (max.) Mounting screw M6x14 max. Mounting on a support or rails (shown with optional connection bars oriented for rear access) (rear view) Drilling plan(front view) Detail of connecting part Oriented for rear access 3P 4P 3P 4P Support or rail 8.5 8.5 3.2t 50 37.5 75 3.2t max 105 14.2 14.2 22.2 22.2 4-6 17.5 15 22.5 15 35 70 4-6 Mounting through the backplate (shown with optional connection bars oriented for rear access) Mounting Plate Mounting Screw M5x20a 155 102 45 68.2 60.2 3.2t 3.2t 113 155 3P (rear view) Mounting Plate 4P Drilling plan(front view) 3P 4P 2-6 4-6 168 180 Detail of connecting part Oriented for rear access 8.5 3.2t 14.2 14.2 22.2 22.2 8.5 3.2t 4 (61) 97 101 121 17 17 15 30 30 30 30 30 30 94 60 124 3P (rear view) Mounting Plate Drilling plan(front view) 4P 3P 4P Detail of connecting part Oriented for front access 8 27 22.2 Mounting on the backplate (optional connection bars must be oriented for front access) 3.2t 21.8 Insulating plate Mounting screw M5 NUT 155 102 45 185 152 3.2t 8 125 8.5 21.8 4 (61) 144 148 168 3.2t 21.8 1 Mounting plate Insulating plate 17 17 30 30 30 30 30 8 8.5 2-6 4-6 15 15 30 60 Note that the insulation plate (supplied as standard) must be fitted between the base and the backplate. page 95 The Ultimate Safety Breaker

S160-NJ, S160-GJ, E250-NJ, S250-NJ, S250-GJ, S250-NN. (optional) The Ultimate Safety Breaker page 96

S160-NJ, S160-GJ, E250-NJ, S250-NJ, S250-GJ, S250-NN. Plug-in Versions. Termination of Busbar Support or rail Preperation of conductor 15.5 (max.) 9 Mounting screw M8x18 max. 22 (max.) 6 (max.) Mounting on a support or rails (shown with optional connection bars oriented for rear access) Support or rail Mounting through the backplate (shown with optional connection bars oriented for rear access) Mounting plate 88 76.5 Mounting screw M5x20 165 102 45 4t 4t 116 172 (61) 4 97 101 121 27 42 Mounting on the backplate (optional connection bars must be oriented for front access) 22 Insulating plate 4t Mounting screw M5 NUT 20 165 102 45 160 20 4 (61) 144 148 168 22 1 Mounting plate Insulating plate page 97 The Ultimate Safety Breaker

H125-NJ, L125-NJ, H160-NJ, L160-NJ, S250-NE, S250-GE, S250-PE, H250-NJ, H250-NE, L250-NJ. The Ultimate Safety Breaker page 98

H125-NJ, L125-NJ, H160-NJ, L160-NJ, S250-NE, S250-GE, S250-PE, H250-NJ, H250-NE, L250-NJ. Plug-in Versions. Termination of Busbar Support or rail Preperation of conductor 15.5 (max.) 9 Mounting screw M8x18 max. 22 (max.) 6 (max.) Mounting on a support or rails (shown with optional connection bars oriented for rear access) Support or rail Mounting through the backplate (shown with optional connection bars oriented for rear access) Mounting plate 88 76.5 Mounting screw M5x20 165 102 45 116 172 4t 4t 96 4 132 136 156 27 42 Mounting on the backplate (optional connection bars must be oriented for front access) 4t 22 Insulating plate Mounting screw M5 NUT 20 165 102 45 160 20 4 96 179 183 203 22 1 Mounting plate Insulating plate page 99 The Ultimate Safety Breaker

E400-NJ, S400-CJ, S400-NJ, S400-NE, S400-GJ, S400-GE, S400-NN. The Ultimate Safety Breaker page 100

E400-NJ, S400-CJ, S400-NJ, S400-NE, S400-GJ, S400-GE, S400-NN. Plug-in Versions. Termination of Busbar Support or rail Preperation of conductor 20 (max.) 30 (max.) 11 8 (max.) Mounting screw M10x30 max. Mounting on a support or rails (shown with optional connection bars oriented for rear access) Support or rail Mounting through the backplate (shown with optional connection bars oriented for rear access) Mounting plate Mounting screw M5 x 20 113 102 260 102 90 198 258 276 6t 6t 4 97 138 142 180 65 48 Mounting on the backplate (optional connection bars must be oriented for front access) Mounting screw M6x70 32 1 6t Insulating plate Mounting plate 260 102 90 4 97 204 208 246 32 1 12 Mounting M6 NUT Insulating plate page 101 The Ultimate Safety Breaker

H400-NJ, H400-NE, L400-NJ, L400-NE. The Ultimate Safety Breaker page 102

H400-NJ, H400-NE, L400-NJ, L400-NE. Plug-in Versions. Termination of Busbar Support or rail Preperation of conductor 20 (max.) 11 188 30 (max.) 8 (max.) Mounting screw M10x30 max. Mounting on a support or rails (shown with optional connection bars oriented for rear access) Support or rail 188 Mounting through the backplate (shown with optional connection bars oriented for rear access) Mounting plate Mounting screw M5 x 20 113 102 260 102 90 198 258 276 6t 6t 4 134 175 179 217 65 48 Mounting on the backplate (optional connection bars must be oriented for front access) Mounting screw M6x70 33 32 1 6t Insulating plate Mounting plate 260 102 90 4 134 241 245 283 32 1 12 Insulating plate page 103 The Ultimate Safety Breaker

E630-NE, S630-CE, S630-GE, S630-NN The Ultimate Safety Breaker page 104

E630-NE, S630-CE, S630-GE, S630-NN. Plug-in Versions. Termination of Busbar Support or rail Preperation of conductor 20 (max.) 30 (max.) 11 8 (max.) Mounting screw M10x30 max. Mounting on a support or rails (shown with optional connection bars oriented for rear access) Support or rail Mounting through the backplate (shown with optional connection bars oriented for rear access) Mounting plate Mounting screw M5 x 20 113 102 260 102 90 198 258 276 6t 6t 4 97 138 142 180 65 48 Mounting on the backplate (optional connection bars must be oriented for front access) Mounting screw M6x70 32 1 6t Insulating plate Mounting plate 260 102 90 4 97 204 208 246 32 1 12 Mounting M6 NUT Insulating plate page 105 The Ultimate Safety Breaker

Breaker Mounted Handle Applicable MCCB A S160-NJ, E250-NJ, S250-NJ, S250-GJ, S250-NN 106+2 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 141+2 The Ultimate Safety Breaker page 106

Breaker Mounted Handle page 107 The Ultimate Safety Breaker

Door Mounted Handle The Ultimate Safety Breaker page 108

Door Mounted Handle Applicable MCCB A*1 B C D Shaft support S160-NJ, E250-NJ, S250-NJ, S250-GJ S250-NN 540 max. 370 421 186 With + H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 575 max. 370 421 221 With + page 109 The Ultimate Safety Breaker

Door Mounted Handle The Ultimate Safety Breaker page 110

Terminal Covers MCCB type Connection A B B C D 1P 3P 4P 1P 3P 4P 3P4P 1P 3P 4P 1P 3P 4P E125,S125 Front conn. 30 90 120 40 40 40-48 48 48 46 46 46 Solderless Terminal 30 90 120 2.5 2.5 2.5 6 62.5 61 61 60 59.5 59.5 S160,-NJ, S160NN Front conn. (1) 35 105 140 55 55 55-54 54 54 52 52 52 E250-NJ, S250-NJ, Solderless Terminal 35 105 140 2.5 2.5 2.5 6 63 61 61 49.5 59.5 59.5 S250-GJ, S250-NN H125, L125, H160, L160, Front conn. (1) - 105 140-55 55 - - 89 89-87 87 S250-NE, S250-GE, S250-PE Solderless Terminal - 105 140-2.5 2.5 4.5-96 96-59.5 59.5 H250, L250 E400, S400 Front conn. - 180 240-110 114 - - 97 99-96 98 E630, S630 Solderless Terminal - 140 185-3 3 4.5-97 97-93 93 H400, L400 Front conn. - 180 240-110 114 - - 134 136-96 98 Solderless Terminal - 140 185-3 3 4.5-134 134-93 93 page 111 The Ultimate Safety Breaker

Terminal Covers Terminal covers for rear connections (CR) and plug-in MCCBs(CR) MCCB type A 3 poles 4 poles B B C D E125, S125 90 120 2 6 41.5 40.5 S160, E250, S250-NJ, S250-GJ, S250-NN 105 140 2 6 41.5 39.5 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 105 140 2 6 77.5 39.5 E400, S400, H400, L400, E630, S630 140 185 3 4.5 97 93 The Ultimate Safety Breaker page 112

Interpole Barriers MCCB type A B E125, S125 47 53 S160, E250, S250-NJ, S250-GJ, S250-NN 100 53 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 100 88 E400, S400, E630, S630 110 95 H400, L400 110 95 page 113 The Ultimate Safety Breaker

Terminal Blocks for Front-Connected and Rear-Connected MCCBs 16.2 71 ON OFF OP1 OP2 OS1 OS2 16 151815 16 80 OCR controller terminal screws M3.5 25.2 74 Terminal Block for Preferential Trip Alarm MCCB type A A B C Fig E125, S125-3 0.5 40 2 S160, E250, S250-NJ, S250-EJ, S250-NN 2-0.5 40 1 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 2-35.5 75 1 16.2 71 ON OFF OP1 OP2 OS1 OS2 25.2 16 151815 16 80 OCR controller terminal screws M3.5 Terminal Block for Preferential Trip Alarm 74 MCCB type A B C E400, S400, E630, S630 39.5 30.5 70 H400, L400 39.5 67.5 107 Comments: 1. The tightening torque for the M3.5 terminal screw is 0.9 to 1.2 Nm. 2. Connection wire size is 2.5 mm2 (max). 3. When you specify Ground Fault Trip on electronic MCCBs with 3 poles the terminal block is automatically fitted to connect with the external neutral CT for 3 phases 4 wires system. 4. Terminal block for preferential trip alarm can be installed remote to the breaker. Contact us for details. The Ultimate Safety Breaker page 114

Slide Interlocks page 115 The Ultimate Safety Breaker

Slide Interlocks MCCB type A S160,E250, S250-NJ, S250-GJ, S250-NN 91.7 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 126.7 The Ultimate Safety Breaker page 116

Slide Interlocks page 117 The Ultimate Safety Breaker

Link Interlocks The Ultimate Safety Breaker page 118

Link Interlocks MCCB type A S160, E250, S250-NJ, S250-GJ, S250-NN 81.7 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 116.7 page 119 The Ultimate Safety Breaker

The Ultimate Safety Breaker page 120

page 121 The Ultimate Safety Breaker

The Ultimate Safety Breaker page 122

MCCB type A B Cable length C D S160, E250, S250-NE, S250-GE, S250-NN 81.7 64 1.0m 155min. 480max. 180min. 480max. H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 116.7 99 1.5m 155min. 980max. 180min. 980max. page 123 The Ultimate Safety Breaker

The Ultimate Safety Breaker page 124

page 125 The Ultimate Safety Breaker

Position of Trip Button Positions of Trip Button HL LC D B C A Trip button MCCB type Poles A B C D S125 3, 4 13.8 20.4 3.3 4.3 S160, E250, S250-NJ, S250-GJ, S250-NN 3, 4 17.2 20.4 3.3 4.3 H125, L125, H160, L160, S250-NE, S250-GE, S250-PE, H250, L250 3, 4 17.2 20.4 3.3 4.3 E400, S400, H400, L400, E630, S630 3, 4 21.6 37.2 5.3 6.6` The Ultimate Safety Breaker page 126

External Neutral CT NAME PLATE 2- M4 40 K k l 50 20 110 4- M6 57 4- Ø 8 50 105 75 100 Door Flanges 2- Ø 6.5 2- Ø 3.5 A 0.5 4- R7.5 A 151 ±0.2 24.5 4- R7.5 4- R1 18 92 ±0.2 47 105 106 ±0.2 94 130 ( 18 ) 4- Ø 8.3 4- Ø 4.3 24 A SECTION A-A 2 SECTION A-A 12 ( 20) 160 20 A 200 4- Ø 6.5 50 Door Flange for toggle-operated 125A and 250A frame 4- Ø 3.5 80 ±0.2 A 4- R 7.5 0.5 R7.5 Door Flange for motor-operated 125A and 250A frame ( 18 ) A 4- R1.5 120 ±0.2 93 135 12 156 ±0.2 2 0.5 25 150 ±0.2 164 200 4- Ø 8.3 4- Ø 4.3 18 53 A SECTION A-A 18 144 ( 18) 180 A SECTION A-A 95 Door Flange for toggle-operated 400A and 630A frame Door Flange for motor-operated 400A and 630A frame page 127 The Ultimate Safety Breaker

DIRECT OPENING Under the heading Measures to minimise the risk in the event of failure, IEC 60204-1 Safety of Machinery-Electrical Equipment Machinery includes the following recommendation: -the use of switching devices having positive (or direct) opening operation. 7