TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER. INSTRUCTION NUMBER: AO of 9

Similar documents
Cleveland-Kidder. Design Features

Cleveland-Kidder Ultra

WEB CONTROL PRODUCTS

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual

A Member of the. Integrated Metering Technologies

Web Tension Technology

A Member of the. Integrated Metering Technologies

Installation Manual Model 3800/3810

II DISTRIBUTION & SUBSTATION TYPE C

SCHMIDT COUPLINGS OPERATIONAL BENEFITS

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

AD-7 THERMAL INDICATING AMMETER

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

TBM Series 3-Way Ball Valve

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

"WHERE TUBING AND FITTINGS COME TOGETHER"

37SCENE 46SCENE 79SCENE

EZ Mount 1. Load Cell Mounting Kit. Installation Guide

Straight-Bore Clutch LSCC-32, 44, 54

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

SPC-PANEL Simplex, Single Phase Pump Control Panel

Installation Instructions Model Geobeam

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Motoweigh Dynamic In-motion Checkweighing System. Installation Manual

CRD400 Fitting Inserter OPERATIONS MANUAL

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

AD-7. Instruction Manual. Thermal Indicating Ammeter HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81)

RL1900 SERIES. Mounting Assembly Kit. Installation Guide

DeZURIK 2 20" BOS BUTTERFLY VALVES

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

ASSEMBLY OF TROLLEY TO HOIST

Installation and Operating Instruction for Complete Freewheels FRS, FRSG, and FRZ. E e Anderson Place Telephone

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Pump Installation and Service Manual HRS Hydromatic Retractable System

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

CD Couplings SERIES A1C. MTY (81) MEX (55) QRO (442) DIST.

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

RV-10 Center Arm Rest Console

Power Series Amplifiers Installation Manual / Quick Start Guide

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

HR-20P Pneumatically Controlled Pressure Regulator

Hose reel. Models and Installation and maintenance guide. Danger

A30 Single Range Tensioncells

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

HIGH VOLTAGE DIGITAL AMMETER

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Using the LCT100 for Load Cell Troubleshooting

Raydot LLC 24 Actuator (115 VOLT)

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

BEAMER Tilt Beam Sensor

LG Alert TM Helping Drivers Operate Safely. LG Alert Oshkosh Truck Corporation User / Installation Manual

G3PE-Single-phase. Solid State Relays for Heaters

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

Advanced Technology Tension Clutches

Manual Transfer Switch

Air Curtain. Installation, Operating and Maintenance Instructions

Guardian Steel Gear Shaft Coupling

High Velocity Series Air Curtains

FK75 / FK95 Quick Installation Guide

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

LG Alert TM Helping Drivers Operate Safely. LG Alert Lateral Acceleration Indicator User / Installation Manual

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

BP1204 INSTALLATION/OWNER'S MANUAL

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

AIR CHAMP PRODUCTS. User Manual. Models DPC-9T and DPC-11T. (i) FORM NO. L C-0501

DAP-625S and DAP-875S

12-1/4 x 3-1/2 Electric Wheel Brake

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Installation Guide. Marine Filter SURT023M SURT024M

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

Web Volume Control Model WV220

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

Push Trolley. Owner s Manual

Environmental Series Air Curtains

1000-LB. ENGINE STAND

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Instruction Manual August milltronics MSI BELT SCALE

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Installation and Operation Instructions Safety Director Arrow

SETRA Operating Instructions Series DPT 230 Pressure Transducers

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

1000 lb. Adjustable Gantry Crane

Transcription:

CLEVELAND-KIDDER SLIM CELL TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER INSTRUCTION NUMBER: AO-70165 1 of 9

1.0 GENERAL INFORMATION 1.1 RECEIVING AND UNPACKING Handle and unpack the equipment carefully. Immediately upon arrival, check the shipment against the packing list. Any damage should be reported immediately to the carrier and to the nearest CMC representative. Equipment that will not be installed immediately should be stored in a clean, dry location. Precautions should be taken to prevent moisture, dust and dirt from accumulating in storage and installation areas 1.2 PRECAUTIONS 1.2.1 Shipping - It is recommended that the sensing roll be removed when the machine is shipped with the transducers mounted. The shock and vibration transmitted to the transducers by the sensing roll during transporting can damage them. 1.2.2 Roll Balance - The sensing roll should be balanced to prevent forces caused by imbalance. These forces cause a noise signal to be superimposed on the tension signal. The centrifugal force (F) caused by imbalance can be calculated using the equation below. F = 28.6 x 10-6 x W x R x (RPM) 2 Lbs. W = Weight of roll in pounds R = Displacement of mass of roll from the axis of rotation in inches RPM = Revolution per minute Critical roll = 4.8 x 10 6 x Shaft O.D. speed in RPM (Shaft Length) 2 Dimensions are in inches. To assure that this problem is avoided, the critical roll speed should at least be 20% above the roll speed attained at maximum web speed. 1.2.4 Overloading - Repetitive overloading above the maximum working force or severe overloading should be avoided because it will damage the transducers. 1.3 SPECIFICATIONS Gage Resistance - End to end resistance 440-480 Ohms Gage Factor Excitation Voltage Output Signal at Rated MWF Output Impedance - 100 nominal -10 VDC or VAC (RMS) maximum - 100 175 mv nominal per Transducer (with 10VDC or VAC rms exitation voltage - Approximately 880 ohms per Transducer Required Input Impedance of Tension Amplifier - 5K ohms per Transducer (1/2 bridge) It is recommended that the force (F) be less than 5% of the resultant web force at the maximum web speed for most applications. 1.2.3 Critical Roll Speed - Even with a balanced roll, a vibration can be set up in a stationary shaft. If this vibration (in cycles per minute) occurs at the harmonic frequency of the shaft, the transducers can be damaged. To determine the critical roll speed, use the following formula: Maximum Voltage, Gage to Beam or Base (Ground) Operating Temperature Range Compliant - 50 VDC - 0 F to +200 F INSTRUCTION NUMBER: AO-70165 2of 9

1.4 DESCRIPTION The Cleveland-Kidder SLIM CELL transducers utilize a sensing twin beam to which semiconductor strain gages are bonded. With these high output signal gages a very small force on the sensing beam will be shown as a change in the tension signal. MACHINE FRAME For many applications SLIM CELL transducers are for use with rotating (live) shaft rolls that are traditionally mounted in Pillow Block Bearings. See Figure 1. For mounting dimensions see Figure 2. But SLIM CELL transducers can also be used with stationary (dead) shaft rollers. SLIM CELL TRANSDUCER Figure 1 M (BOLT DIA) G B H Y S R T A C C W D J N X (BOLT DIA) E K L I F O P U V Q SLIM CELL (ALONE) MOUNTING BRACKET (WITH SLIM CELL) Dimensions in inches, allow 2.5 in clearance for Connector SIZE A B C D E* F G H I J K L M SLIM1 4.50 3.75 2.996-3.000 1.50-0.12 1.31 1.02 0.07 2.30 2.00 0.65 ¼ (3) SLIM2 5.80 4.75 4.196-4.200 2.46-0.14 1.70 1.32 0.10 3.05 2.50 0.65 3/8 (3) N O P Q R S T U V W X Y** 1.02 4.22 4.78 6.00 3.000-3.006 4.50 0.55 0.55 1.60 4.75 3/8 (2) ¼ (3) 1.36 5.50 6.5 8.00 4.200-4.206 5.80 0.65 0.65 2.00 6.2 ½ (2) 3/8 (3) * See Table 3 for permissible Shaft Diameter. Bore Diameter is typically between Nominal Diameter+0.0007 and +0.0017 inch. ** Bolts supplied with bracket Dimensions in mm, allow 64 mm in clearance for Connector SIZE A B C D E* F G H I J K L M SLIM1 114.3 95.3 76.10-76.20 38.1-3.0 33.3 25.9 1.8 58.4 50.8 16.5 6mm (3) SLIM2 174.3 120.7 106.58-106.68 62.5-3.6 43.2 33.5 2.5 77.5 63.5 16.5 8mm (3) N O P Q R S T U V W X Y** 25.9 107.2 121.4 152.4 76.20-76.35 114.3 14.0 14.0 40.6 120.6 10mm (2) ¼ (3) 34.5 139.7 165.1 203.2 106.68-106.83 174.3 16.5 16.5 50.8 157.5 12mm (2) 3/8 (3) * See Table 3 for permissible Shaft Diameter. Bore Diameter is typically between Nominal Diameter+0.018 and +0.043 mm. ** Bolts supplied with bracket Figure 2 INSTRUCTION NUMBER: AO-70165 3of 9

2.0 INSTALLATION 2.1 SELECTION OF TRANSDUCER MOUNTING LOCATION When selecting a transducer mounting location, keep in mind that the tension-sensing roll must NOT be mounted where the web wrap angle can vary. Any change in the wrap angle will be sensed by the transducers as a change in tension, and indicated as such on the tension indicator. location for the transducers where the wrap angle does not vary. The change in indicated tension that will result can be calculated and, if small, may not be significant. 2.2 MOUNTING SURFACE PREPARATION The mounting surfaces for the transducers should be flat and parallel. Prepare the machine frames or mounting surfaces by removing any loose paint, rust, scale, etc. WRAP VARIES WRAP VARIES PROCESS OK FOR TENSION SENSING 2.3 MOUNTING STYLE The SLIM CELL Transducer is very versatile and can be mounted in several mounting styles. If you have not decided which style to use, evaluate which is the most convenient, based on the machine frame, ease of assembly and protection. See Figure 4. Figure 3 In some cases, it may be impossible to find a 62 DEG OF ANGULAR ALIGMENT WITH BOLT IN POSITION INSIDE FRAME OUTSIDE FRAME WITH MOUNTING BRACKET WITH ALIGNMENT PILOT BP WITH ALIGNMENT PILOT BP BLANK BACK PLATE BF FLUSH BF FLUSH BF WITH ALIGNMENT PILOT HP WITH ALIGNMENT PILOT HP BACK PLATE WITH HOLE HF FLUSH HF FLUSH HF Figure 4 INSTRUCTION NUMBER: AO-70165 4of 9

2.4 INSTALLATION OF THE TRANSDUCER The Slim Cell can be mounted directly to the machine frame or to the optional mounting bracket. Mounting the Slim Cell to the Machine Frame Note that the Slim Cell can be mounted on either side of the machine frame (see Figure 4). Determine the arrangement that best suits your application. The load cell is mounted in place with 3 bolts. Before drilling and tapping the mounting holes in the machine frame read the instructions below. (Orientation and Mounting of the Slim Cell) to insure that the Slim Cell is properly aligned. The holes should be located so that load cell can be mounted to achieve proper alignment. Refer to dimension B and M in Figure 2 for the proper bolt hole centers and bolt size. The bolt hole centers are evenly spaced on a circle and are 120 degrees from each other. Mounting the Bracket to the Machine Frame Determine the correct position for the mounting bracket. Note that the Slim Cell can be mounted on either side of the bracket. Refer to Figure 4. Determine the arrangement that best suits your application. Drill and tap two mounting holes in the machine frame for each bracket. Refer to dimension X in Figure 2 for the proper bolt diameter. The Slim Cell is mounted to the bracket with 3 bolts. Before mounting the load cell in place read the instructions below (Orientation and Mounting of the Slim Cell) to insure that it is properly aligned. 2.5 ORIENTATION AND MOUNTING OF THE LOAD CELL Before bolting the load cell in place it must be positioned so that is aligned with the tension force (load direction). The Slim Cell is properly oriented when the load direction arrow (bisector of the wrap angle- see Figure 7) is pointing along a line connecting the + and - signs on the sides of the load cell. Position the Slim Cell so that it can be bolted in place at the position that is the closest to the proper orientation. (see Figure 5). Insert the bolts and partially tighten. To achieve the exact orientation, rotate the Slim Cell outer ring as required so that the load direction is pointing through the +/- axis. The outer ring can be rotated 60 degrees. When the Slim Cell is properly aligned completely tighten the mounting bolts. If the force points to the +, the INSTRUCTION NUMBER: AO-70165 5of 9

output signal of the transducer is positive. If the force points to the - the output is negative. This is importance to know when wiring the transducer to the amplifier, indicator, or controller terminals. Interchanging the B (black wire) and C (red wire) connections may be required in order to provide the proper signal polarity for the device. (see Figure 6). EXCITATION VOLTAGE SHIELD (-) (+) BLK WHT BLK B A C B TENSION GAGE TEMP. COMPENSATION NETWORK COMPRESSION GAGE TENSION GAGE NO. 1 TRANSDUCER TEMP. COMPENSATION 2.6 INSTALLATION PRECAUTIONS OUTPUT SIGNAL (-) (+) WHT RED A C NETWORK COMPRESSION GAGE NO. 2 TRANSDUCER To insure proper installation and operation of the system, the following steps should be performed in sequence. Failure to do so could seriously damaged the Transducers and void the warranty: - For SLIM CELLS that don t have a through hole, make sure that the shaft doesn t go too deep inside the Load Cell and touch the back plate (See Figure 2 letter H). - When mounting a roll with a shaft that comes through the back plate (see Figure 4), push the adapter to the inside of the SLIM CELL before you tighten the set screws to allow for shaft expansion. - SLIM CELL installations having the roll and SLIM CELL mounted on the inside of a machine might require installing the roll and SLIM CELLS as a unit. WIRING DIAGRAM FOR TRANSDUCERS Figure 6 Refer to the installation wiring diagrams supplied with the Cleveland-Kidder tension indicator or controller for making the transducer connections. Make certain that the cables do not interfere with the web path and that they are away from gearing or other moving parts. Figure 6 is for reference only for use with a full bridge transducer configuration. Many of the Cleveland- Kidder indicators and controllers use only half bridge transducer inputs and then sum the two transducers signals internally. See the applicable installation wiring diagrams for the tension indicator or controller. 3.1 MATING CONNECTORS FOR TRANSDUCERS 2.7 SHAFT EXPANSION - The SLIM CELL is design to accommodate shaft expansion. The only precaution, as said in 2.6 INSTALLATION PRECAUTIONS, is that in case of a shaft entering through the back plate of the Load Cell (The two back plates facing each other), you need to push the adapter toward the front of the SLIM SPIN before you tighten the set screws to allow for shaft expansion. 3.0 ELECTRICAL CONNECTION Mating Straight Connector, Boot and Clamp Kit Mating 90 Angle Connector, Boot and Clamp Kit CMC P/N MO-09854 MO-09855 3.2 INTRINSICALLY SAFE TRANSDUCERS These transducers are intrinsically safe only when they are part of a complete intrinsically safe system using the TIX-1 tension indicator or wired per CMC control drawings. Barrier block assemblies and/or the individual barrier blocks may be purchased from CMC. Please contact CMC for part numbers and pricing. INSTRUCTION NUMBER: AO-70165 6of 9

4.0 TEMPERATURE COMPENSATION The transducers are supplied with a temperature compensation network (except size 1 that don t require it) which is in series with the output signal lead. The compensation circuit is designed to be used with a tension amplifier, which has an input impedance of 10K Ohms when a pair of transducers connected as a full bridge is used. If only one transducer is used, the tension amplifier impedance should be 5K Ohms. If other than the input impedances given above are used, drift will occur in the tension amplifier output when the transducer temperature changes. 5.0 SINGLE TRANSDUCER OPERATION For those applications where only one transducer is required, a dummy circuit may or may not be required depending upon the input circuit of the tension amplifier. Consult the factory for this information. The dummy circuit consisting of two resistors is substituted in place of the second transducer. The resistors should have a resistance value between 100 and 150 Ohms and should be matched to within 1%. Dummy circuits are available from the factory for connecting to tension indicators or controllers. 6.0 TROUBLESHOOTING 6.1 EXCESSIVE OUTPUT SIGNAL WITH NO LOAD There may be a high degree of misalignment of the transducers causing a severe pre-load. Or The sensing guide roll assembly may be excessively heavy. The sensing guide roll should not weigh more than ½ the maximum working force of the transducers in most cases. Or The transducer may have too small a maximum working force for the application. Replace with a higher maximum working force transducer or decrease the web wrap angle. 6.2 LOW OUTPUT SIGNAL The transducer may have too large a maximum working force for the application. Replace with a lower maximum working force transducer or increase web wrap angle. 6.3 WRONG POLARITY OF OUTPUT SIGNAL Transducers may have been incorrectly oriented. See Section 2.4 for proper load direction. Alternately, change the transducer excitation voltage by interchanging the B and C connections. 6.4 OUTPUT SIGNAL NOT LINEAR, ZERO SHIFTS DURING OPERATION Check transducer and tension roll mounting. All mounting bolts must be tight. Check that there is no dirt or foreign matter interfering with the transducer mounting. Check that mounting surface is flat and rigid. 6.5 NO OUTPUT SIGNAL Check to see that all connections have been made completely. Check for places where the connecting cables might be crimped or cut. 6.6 VERY HIGH OUTPUT WITH NO LOAD Check cables and connectors for good connections and check continuity of cables with an ohmmeter. Check for proper wiring to transducers. Check transducer gage resistance as given in the following chart at room temperature with no load applied. TRANSDUCER GAGE RESISTANCE CHECK Resistance (ohms) SLIM CELL 1 or 2 Pin C to B 420±20 Pin A to B 900-1100 Pin A to C 900-1100 INSTRUCTION NUMBER: AO-70165 7of 9

7.0 SERVICE ASSISTANCE AND REPAIR For additional service assistance, please obtain the Type, MWF, and Purchase Order Number from the nameplate. Contact the Factory Service Department. Phone: (216) 524-8800 Fax: (216) 642-5155 Disassembly by improperly trained personnel may result in additional damage to these units. Should repairs be required or for warranty repairs, contact the Customer Service Department for a return authorization number before returning the units. 8.0 PRODUCT LITTERATURE A copy of the Specification Sheet SC-C&S-DS is included at the end of this manual. INSTRUCTION NUMBER: AO-70165 8of 9

LIMITED WARRANTY. ALL GOODS ARE SOLD SUBJECT TO THE MUTUAL AGREEMENT THAT THEY ARE WARRANTED BY THE COMPANY TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR ONE YEAR FROM THE DATE OF SHIPMENT. THE COMPANY'S WARRANTY DOES NOT COVER, AND IT MAKES NO WARRANTY WITH RESPECT TO ANY DEFECT, FAILURE, DEFICIENCY OR ERROR WHICH IS: A) NOT REPORTED TO THE COMPANY WITHIN THE APPLICABLE WARRANTY PERIOD; OR B) DUE TO MISAPPLICATION, MODIFICATION, DISASSEMBLY, ABUSE, MISUSE, IMPROPER INSTALLATION, UNAUTHORIZED REPAIR, IMPROPER MAINTENANCE OR ABNORMAL CONDITIONS OF TEMPERATURE, DIRT OR CORROSIVE MATTER; OR C) DUE TO OPERATION, EITHER INTENTIONAL OR OTHERWISE, ABOVE RATED CAPACITIES OR IN AN OTHERWISE IMPROPER MANNER. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES. THE PARTIES AGREE THAT THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARE EXCLUDED FROM THE SALE OF GOODS. LIMITATION OF REMEDY AND LIABILITY. THE REMEDY PROVIDED HEREIN IS BUYER'S SOLE AND EXCLUSIVE REMEDY. THE BUYER'S REMEDY AND THE COMPANY'S LIABILITY (WHETHER UNDER THE THEORIES OF BREACH OF WARRANTY, CONTRACT, TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY) SHALL BE LIMITED EXCLUSIVELY AT THE COMPANY'S OPTION TO REPLACING OR REPAIRING WITHOUT CHARGE AT THE COMPANY'S FACTORY OR ELSEWHERE ANY MATERIAL OR WORKMANSHIP DEFECTS WHICH BECOME APPARENT WITHIN ONE YEAR FROM THE DATE ON WHICH THE GOODS WERE SHIPPED. THE COMPANY SHALL NOT BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF USE, INCOME OR PROFIT, OR LOSSES SUSTAINED AS A RESULT OF INJURY (INCLUDING DEATH) TO ANY PERSON OR DAMAGES TO PROPERTY. THE COMPANY SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND ARISING FROM THE INSTALLATION AND/OR USE OF THE GOODS BY ANYONE. BY THE ACCEPTANCE OF THE GOODS, THE BUYER SHALL ASSUME ALL LIABILITY FOR ANY DAMAGES WHICH MAY RESULT FROM USE OR MISUSE BY THE BUYER, ITS EMPLOYEES OR BY OTHERS. INSTRUCTION NUMBER: AO-70165 9of 9