TRAC-Station BT Installation Instructions

Similar documents
CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

CSI-300 Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

Installation Guide(s)

CSI-100 Installation Instructions

CV41. Vehicle Mounting Kit. Reference Guide

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Security and Keyless Entry Installation Guide ca 1051

CA-110 Installation Instructions

MM1 Installation Instructions

Adjustable Light Kits E-Z-Go TXT All Models Installation Instructions

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ONE TOUCH CONTROL BOX

Paxton. ins us. Paxlock US

2904 Power Supply Installation Instructions I-EA00041

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

Plasma Display Electric Ceiling Lifts

M400 Series Double Locks. Features

LGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions

Elmdene International Ltd

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option

Instruction Manual for the. E-SL 450 Series

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

AccuPower AQU128B Installation Instructions

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Installation Instructions RF4510-EA

Vehicle Security System

Installation Instructions

TC26-B Vehicle Sensor

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN

WirelessONE. Kit INSTALLATION GUIDE. Key Fob Activated Compressor System

TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK INSTALLATION MANUAL SADDLE BOX STARTER KIT. Model: QDSKSA01. Part No.

ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

MAPNET II Transceiver Installation Instructions

Installation Instructions

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

2 Way Security and Keyless Entry Installation Guide ca 1553

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

CA-210 Installation Instructions

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

TruVision HD-TVI Series 4 PTZ Dome Camera Installation Guide

AccuPower AQU126B Installation Instructions

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation Instructions

ME AGS Auto Gen Start System for Coach Generators. Operator s Manual.

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Plasma Display Electric Pop-Up Lift (PUL)

SHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS

CAUTION. Even Brakes with a black cable need second vehicle kit Even Brakes with a blue cable need second vehicle kit 98450

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

Outdoor Enclosure Power System ENC X100MP48F20-AC6

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

MODELS: SPL-12W, SPL-12B, SPL-12C IMPORTANT! READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT.

A-200 Speed Dome. Quick Start Guide UD.6L0201D0127A02

RK Standby Battery Operator s Manual

SPACESAVER EC-300 A ELECTRICS

TS93 EMF T/PT/TDE. Surface applied door closer

CSI-400 Installation Instructions

Model APS-510C Installation Manual Remote Control Vehicle Security System

Installation Instructions For Profile Series v.g1.5 Cylindrical Lock

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

HANDLING MECHANICAL INSTALLATION

ADA EZ Rev. H, 8/23/11

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

Vehicle Security System

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

Installation Instructions

Digital/Analog Amplifiers Installation Instructions

Removable Applied Panel Mounting System

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

AWZ 200. AWZ 13,8V/2A/7Ah/L

L5000 Plus. Installation & Setup Guide

RK Standby Battery Operator s Manual

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Installation Instructions

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Outdoor Enclosure Power System ENC X100MP48F20

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Manual - Inside Front Cover (Blank)

Model APS-101N Installation Manual

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual

Electrical Options Booklet. Table of Contents

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

INSTALLATION INSTRUCTIONS AM rev. A

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

Transcription:

TRAC-Station BT Installation Instructions P/N 10103024P1 November 2011 2011 UTC Fire & Security. All rights reserved. Introduction This is the Supra TRAC-Station BT Installation Instructions. Read these instructions and the lockset installation instructions before installing TRAC-Station BT. If you do not mount TRAC-Station BT accurately, it will not function properly. Supra is not responsible for replacing the TRAC-Station BT if it is damaged or destroyed upon removal. Installation supplies provided Installation instructions Drill template Electronics enclosure with lid Mounting plate (interior) Exterior TRAC-Station BT plate Eight AA batteries Two sets of four #8 flat head screws (Two different screw lengths for the mounting plate) One electrified lockset (no lock core) Four #8 5/16 in. (8 mm) pan head screws and lock washers (for electronics enclosure) Six #4 1/2 in. (13 mm) flat head screws Plastic weather cover assembly CAUTION: The electronics in this package are electrostatic sensitive devices. Before you install the unit, discharge or use a grounding belt. Installation tools required Drill Drill bits File Phillips screwdriver Level or punch Pen or pencil Hardware not provided When a lockset is provided with the TRAC-Station BT, the lockset will not include a lock core. If you install the TRAC-Station BT into a door that has a noncylindrical lock (for example, a mortise lock), you will need additional hardware. Consult a locksmith for the parts you need for the conversion. Figure 1. Standard TRAC-Station BT installation Installation notes The TRAC-Station BT is designed to be installed above, below, or to the side of the lockset (Figure 1). We recommend 6 in. (15 cm) above the lockset, or as far above the lockset as needed to be out of the way of door hardware. To meet ADA requirements, the lockset must be no higher than 48 in. (120 cm) from the ground to center of the device. If you install the TRAC-Station BT in a wood door, align it horizontally with the lockset and latch (Figure 2). When drilling, drill the latch set hole through the backset hole and into the door. You will use this hole to thread the wiring from the lockset to the TRAC-Station BT. Align the TRAC-Station BT drill template (PN: 43336) so that the 5/8 in. (16 mm) wire feed hole intersects with the horizontal hole. Use this channel to feed the wire from the lockset to the TRAC-Station BT. When you install the lockset, allow room for expansion in hot weather. Figure 2. TRAC-Station BT wood door installation

2 Installation To install the TRAC-Station BT: 1. Remove the lid from the electronics enclosure and unplug the four-prong connector. 2. Using the drill template, mark the four mounting holes and the one center wire feed hole on the exterior side of the door. Drill the four mounting holes 9/16 in. (14 mm) and the center wire feed hole 5/8 in. (16 mm) through the door. Note: If you are drilling a metal door, be sure to file the rough edges of the drill holes or use a countersink drill. 3. Remove the existing lockset and install the new lockset using the instructions provided by the manufacturer. Thread the two-wire plug from the lockset through the door and through to the interior using the 5/8 in. (16 mm) wire feed hole. 4. Feed the four-wire plug from the exterior TRAC- Station BT plate through the wire feed hole, and secure the interior mounting plate to the exterior TRAC-Station BT plate (Figure 3). Insert and tighten screws through the interior plate using the recommended screw lengths (Table 1). Note: If the screw does not fully secure the plates to the door when tightened, use a shorter screw. Do not overtighten the long screw. Table 1. Recommended screw length Door thickness Screw length 1.25 to 2.00 in. (32 to 49 mm) 1.00 in. (25 mm) 2.00 to 2.65 in. (50 to 67 mm) 1.75 in. (44 mm) 2.75 to 3.50 in. (68 to 85 mm) 2.50 in. (64 mm) 3.50 to 4.00 in. (85 to 98 mm) 3.00 in. (76 mm) 5. Thread the four-wire plug from the exterior TRAC-Station BT plate, and the two-wire plug from the lockset through the wire feed hole in the electronics enclosure (Figure 4 on page 3). You will attach the wires after securing the enclosure. 6. Use the four #8 5/16 in. (8 mm) pan head screws and lock washers to attach the electronics enclosure to the interior mounting plate. Insert and tighten the screws and lock washers securely. 7. Attach the four-wire plug to the four-wire connector. Snip off the two-wire plug and terminate the two lockset wires on the positive and negative DC output terminals. Polarity is not important when terminating the lockset wires. Figure 3. TRAC-Station BT assembly as example Exterior TRAC-Station BT Plate Lockset 2-wire plug Interior Mounting Plate Electronics Enclosure Electronics Enclosure Lid 4-wire plug

Other wiring options The TRAC-Station BT is designed to interface with a variety of electronic devices. For 12-volt applications, all of the DIP switches need to be closed. For 24-volt applications, all of the DIP switches need to be open. The first two terminals on the circuit board are the input power source. Correct polarity is very important for the TRAC-Station BT to function accurately when wiring for a DC application. The next two terminals marked + and DC output are designated for the output power source. Negative power input must be isolated from negative output. Failure to do so will result in damage to the unit. When wiring, do not short the transformer. Wire the transformer with caution since it is not fuse-protected. The last three terminals are the dry contacts you can use to shunt an alarm or as a trigger to activate a relay or other low voltage device. In order to shunt the alarm circuit when entering a door, wire the TRAC-Station BT dry contacts in parallel at the switch on the field side of the alarm zone. This will ensure the resistor is in the circuit. 3 Figure 4. Electronics enclosure 1 2 3 4 OPEN - INPUT PWR + - DC OUTPUT + NC-RED COM NO-GRN

4 Testing and completing the installation 1. Once the lock is installed, perform an Install function with a valid TRACcess ekey. Refer to the TRACcess ekey user instructions for step by step operation. 2. Test the lock operation using the TRACcess ekey. Refer to the TRACcess ekey user instructions for step by step operation. Test the lock first with the door open and then with the door shut to ensure the lock strike catches the door frame. When you test the lock with your key, the LED at the top of the interface will flash green, indicating the door may be opened. If the TRAC-Station BT is programmed for TIMED mode, the light will remain flashing for a preprogrammed period of time, during which the door may be opened. If the TRAC-Station BT is programmed for LATCHED mode, once the light flashes green, the door may be opened until the TRAC-Station BT is reset. If the TRAC-Station BT is programmed for LATCHED mode, be sure to reset the lock. 3. Once you have tested the lock, place the lid on the back of the electronics enclosure and position the logo directly over the battery pack. Insert the provided six #4 1/2 in. (13mm) flat head screws into the predrilled holes. Hand-tighten the upper right corner screw and continue hand-tightening the remaining screws in a clockwise order. Do not overtighten the screws, as doing so may damage the electronics enclosure and prevent the lid from being securely fastened. 4. Install the plastic weather cover. 5. Record the serial number and installation location. Figure 5. Wiring diagram for continuous unlock option Continuous unlock option (Optional) There is an option in TRAC-Station BT in latched mode to energize the lockset to unlock for long periods of time. Place an 18 AWG jumper between the DC input + and the common relay of the dry contacts (Figure 5). Connect the lockset between DC input + or input - and the normally open relay. When a DisplayKEY or ekey access the TRAC-Station BT, the lockset will energize and be held until the key is used again to relock the lockset. DC output is not used in this application. Battery removal/disposal This product contains eight AA batteries. To remove the batteries, do the following: 1. Remove the lid from the electronics enclosure. 2. Pull the batteries out of the slots. For proper recycling, dispose of all batteries as required by local ordinances or regulations. FCC The device, Assy, Bezel, WTI, part number 10102917G1, complies with part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. 2002/96/EC (WEEE directive). Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. Jumper 1 2 3 4 OPEN - INPUT PWR + - DC OUTPUT + NC-RED COM NO-GRN Supra: 800-547-0252 www.suprasystems.com

5 Introduction TRAC-Lock & TRAC-Station Drill Template P/N 43336-03B November 2011 2011 UTC Fire & Security. All rights reserved. This is the TRAC-Lock & TRAC-Station Drill Template for TRAC-Lock models 001569, 001568, 001570, 001575, and 001576, TRAC-Lock BT models 002074, 002075, 002076, TRAC-Station model 001574 and TRAC-Station BT models 002077, 002078, 002079. 2.65 in. (6.73 cm) 1.07 in. (2.72 cm) 3.25 in. (8.26 cm) 5/8 in. diam. (1.59 cm) 5.85 in. (14.86 cm) 9/16 in. diam. (1.43 cm) 4 holes Supra: 800-547-0252 www.suprasystems.com

6 TRAC-Station BT Wiring Diagram Required FCC ferrite bead For remote mounting: Splice the provided pig-tail connector to the 4-wire plenum cable with the provided gel-filled crimp connectors. Splice the matching colors together. For remote mounting: Route 4-wire plenum cable as required. Bezel (or mortise) key interface For remote mounting: Use the provided gel-filled connectors and splice matching colors together. Use provided tie wrap to ensure stress relief for the wires. Optional alarm shunt schematic Alarm Resistor Zone terminal strip Optional entrance feedback DIP switches: 12 V all closed 24 V all open Door sensor Relay contacts for alarm shunt 24 VDC 1.5 amps Pos output Relay: N/C Relay: Common Relay: N/O 24 VDC, 1.5 amp facility power OR UL approved 35 watt output transformer 110 VAC Splice power wires as required with the provided gel-filled crimp connectors Regulated power output 12 or 24 volt maximum 1 amp Electric locking device Neg output Pos power input Neg power input Detail terminal strip