Advant OCS controls cryogenic installations of CERN s particle accelerator

Similar documents
Transforming Transforming Advanced transformer control and monitoring with TEC

The ATLAS Detector at the Large Hadron Collider. Peter Krieger IPP/University of Toronto

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

Gazprom s Helium Facility in Orenburg Supply & Start-Up of a Linde Liquefier. Klaus Ohlig Twente, July 9 th, 2014

ABB life cycle services Uninterruptible power supplies

OMAR - Power Generation AUTOMATION

Energy Storage. Part 2. Some case studies Alternatives. Thomas Taylor CERN and AT Scientific LLC

Aswan high dam - Distributed control system AUTOMATION

9-O-3A-4 Cryogenic system for the 43 T Hybrid Magnet at LNCMI Grenoble From the needs to the commissioning

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Modernization of the Rüdersdorfer cement plant a quantum leap in technology

ENERGY EFFICIENT DRIVE FOR COAL GRINDING MILLS

Central Region Group Status and Positron Region

Traction Systems GC01DTR01_C 08/2013. Ingeteam Traction

arxiv: v1 [physics.ins-det] 1 Jul 2014

Guri Dam. Ingenuity and energy

Modernisation of a Bucket-Wheel Excavator at the Welzow-South lignite mine, Lausitzer Braunkohle AG, Germany (1996)

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

Modular Standardized Electrical and Control Solutions for Fast Track Projects

SECONDS CAN COST MILLIONS

ABB in primary aluminium From mine to market

ABB Wind Care Service Offering

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics

ACS Medium Voltage AC Drives for Speed and Torque Control of 3 27 MW Motors

Spectrum PowerCC DM Distribution Management The control system for distribution network operators

ABB Service Benefit from our competence and flexibility

Breaking new ground. A circuit breaker with the capacity to switch 15 large power plants

Life cycle services for protection and control relays Full support from start to finish

Advance Your Company s Success in Technology Development & Commercialization PARTNER WITH ARGONNE NATIONAL LABORATORY

Ultrasonic and Magnetic Particle Testing of New Railway Wheels

A new era in asset protection

PowerTech converter family for industry and energy

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

Power and Distribution Transformers

The fact that SkyToll is able to deliver quality results has been proven by its successful projects.

AN ELECTRICAL FUEL PUMPING AND METERING SYSTEM FOR MORE ELECTRICAL AERO-ENGINES

characteristics, including the ability to turn through 180 degrees for an increase in backing thrust.

Balancing act. Microgrid optimization control stabilizes production in solar and hybrid microgrids

TURBOVAC ix Turbomolecular Pumps 90 l/s l/s

Turbo boost. ACTUS is ABB s new simulation software for large turbocharged combustion engines

STATUS OF THE LARGE HADRON COLLIDER (LHC)

First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series

Draft Working List to be done at CERN for ATLAS Central Solenoid. Originated, Dec. 4, 2001 Revised, Dec.5, 2001 Akira Yamamoto (KEK)

Delomatic 400 (DM 400) based Gas Engine and Combined Heat and Power (CHP) Control and Management System

Five years ahead of the future...

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Synthesis Twin. from 6 to 20 kva

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DC Arc-Free Circuit Breaker for Utility-Grid Battery Storage System

Low and medium voltage service. Power Care Customer Support Agreements

Power Conditioning of Microgrids and Co-Generation Systems

How do we make city buses cleaner and more comfortable?

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Versatile and Powerful. Liduro Wind Frequency Converter System

CHAPER 5 POWER FLOW STUDY IN THE INTEGRATED GRID NETWORK

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

600 A CURRENT LEADS WITH DRY AND COMPACT WARM TERMINALS

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

TECHNICAL WHITE PAPER

Workshop on Accelerator Operations Roger Erickson Accelerator Operations and Safety Division

Proven to be better. Development trends in industrial rolling bearings

Driving Forward. Welcome to the fifth issue of our newsletter. MKE Drive Systems beat 2016 targets. Inside this issue.

Capabilities Brochure

Medium Voltage Drives. ABB Value Provider Program Partnership for growth and profit

THE NEXT GENERATION- YAW AND PITCH POSITION MONITORING

Evolution. The proven solution for perfect production reliability. Innovations for a better world.

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

Carat. The solution with highest value creation for sophisticated parts. Innovations for a better world.

Optimization of Total Operating Costs Using Electric Linear Drives

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

2018 ANSYS, Inc. ANSYS.COM

DURMA THE WINNING FORCE LASER CUTTING MACHINES HDFL HDF HDL HD SMART BETTER PARTS BETTER PROFITS MORE FAST MORE QUALITY MORE EFFICIENCY

Learning paths. The path to higher performance ABB UNIVERSITY. ABB University. Learning paths

TURBOVAC i Turbomolecular Pumps 90 l/s l/s

BMW Group Corporate Communications

Ring-geared mill drives. RMD plus Variable-speed solution with mill application features

Optimizing Drive Systems for Energy Savings

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Experimental Investigation of a 40K Single Stage High Frequency Pulse Tube Cryocooler

Design Considerations for Pressure Sensing Integration

Speech Prof. Dr.-Ing. Ulrich Hackenberg. Audi Press Conference International CES, Las Vegas

VARTA Energy Storage Systems

ACS 1000, ACS 1000i. Medium voltage AC drives for control of induction motors from kw

Status of the Nuclotron-M project

Cross Flow Heat Exchanger H352

PNM/EPRI Smart Grid Demonstration. Photovoltaics through Grid Automation, Energy Storage and Demand Response

JLab. By JLab Cryo Group. Presenter: VenkataRao Ganni January 25, 2011

The electro-mechanical power steering with dual pinion

The SGT5-8000H proven in commercial operation

ABB uses an OPAL-RT real time simulator to validate controls of medium voltage power converters

Design Modeling and Simulation of Supervisor Control for Hybrid Power System

Temperature Calibration Guide

APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection

Status of the ESRF RF System Repeated Ceramic Leaks on the Existing Cavities. 12 th ESLS RF meeting Diamond, 1 st -2 nd October, 2008

APPLICATION GUIDE. ACH580 Managing total cost of ownership of HVAC systems

MNS PDUpro Intelligent power distribution unit

LISTEN TO THE LIFEBLOOD OF YOUR MACHINE

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Transcription:

Advant OCS controls cryogenic installations of CERN s particle accelerator CERN s laboratory for particle physics near Geneva, Switzerland, is among the most innovative R&D centers in the world. This approach to research is also reflected in the way it works with its control system suppliers. ABB s Advant Open Control System (OCS), which makes use of objectoriented programming, was chosen to perform one of the most complex automation tasks ever specified: processing 10,000 signals in order to keep the temperature of the world s largest particle accelerating system close to absolute zero. T he Large Electron-Positron (LEP) Collider at CERN s laboratory for particle physics near Geneva generates an enormous amount of energy in an extremely small space (see box on this page). By the summer of 1999, the collision energy had been raised to almost 200 giga electron volts (GeV). Energy levels of this kind are needed to test the standard model of high-energy physics. As the particles are accelerated by superconducting cavity resonators, very low temperatures play an important role in the experiments. In all, four 12-kW helium liquefiers supply liquid helium at a temperature of minus 269 C to the 72 LEP accelerator modules and their 288 resonators. ABB s process control system, Advant OCS (see box far right), has been installed to control the four liquefiers. Advant OCS is fully compatible with other proven systems, such as ABB Master, thereby preserving customer investment in installed equipment. Process control system retrofit In 1986 CERN selected the integrated process control system ABB Master for the control and supervision of the complex cryogenic installations [1]. This system has been performing the I&C tasks as well as all the logic operations. Hans-Karl Kuhn CERN, Centre Européen pour la Recherche Nucléaire Marco Pellin ABB Power Automation CERN s LEP Collider The Large Electron-Positron (LEP) Collider runs in a roughly circular subterranean ring, 27 km long, that straddles the border between France and Switzerland near Geneva [2]. The tunnel in which the particle accelerator is installed has a diameter of 3.8 m and lies at depths ranging from 50 to 170 m. Installed along the tunnel are 3,300 dipoles, which hold the electrically charged particles on their course, 1,300 focusing magnets and 600 correcting magnets. Spaced around the ring are four caverns, 70 m long and 20 m wide and high. These house the experimental areas in which the four detectors OPAL, L3, ALEPH (Apparatus for LEP Physics) and DELPHI (Detector with Lepton, Photon and Hadron Identification) are located 1, 2. In the LEP, two counter-rotating beams, one of electrons and one of positrons, are accelerated to almost the speed of light. These LEP beams, which are injected by a Super Proton Synchrotron (SPS), consist of precisely synchronized pulses in the ma range. In the experimental areas the beams are focused and made to collide with an energy of, at present, typically 192 GeV. As a result of the collision new particles are created, in particular W and Z bosons, both of which have extremely short lifetimes. Their properties and behaviour are observed in the detectors and investigated with the help of computer analyses. Scientists expect the LEP Collider to provide many new insights into the fundamental laws of nature. The installed power rating of the LEP collider is 75 MW, that of a 12-kW cryogenic installation for the superconducting resonators approximately 2.5 MW, the majority of which is for the helium gas compressors. 18 ABB Review 5/1999

Front of the DELPHI particle detector, one of four detectors at CERN s laboratory for particle physics near Geneva. An ABB Advant Open Control System processes 10,000 signals to keep the temperature of parts of the world s largest particle accelerator close to absolute zero. 1 In recent years the particle energy in the LEP has been increased from 90 to 192 GeV and the range of experiments widened, with the result that the MasterPiece stations, especially those used to control the compressors, have been operating close to their limits. As a result of the more demanding conditions ABB and CERN have upgraded the process control system over the past few years through the addition of 34 Advant Controller nodes (10 400-series Advant Controllers and 24 200-series MasterPiece stations), two Advant IMS stations (for linking the process control system to CERN s Oracle database system), five Advant operator stations, and The four helium liquefiers are not central- Nine local networks ten MasterView stations. ized as they have to follow the geometry Advant OCS with open system architecture With its Advant Open Control System (OCS), ABB offers a standard, state-of-the-art platform with open system architecture for the automation of industrial processes. The system is characterized throughout by an object-oriented and distributed structure, high-performance operator stations, very high availability and ease of maintenance. All process and operator stations are linked by a system bus. The process control stations communicate with the I/O units by means of field buses. Every stage in the industrial process can be controlled and monitored from each of the process operator stations. ABB Review 5/1999 19

of the installations, a larger amount of data is required due to the prototype nature of the equipment and the need to optimize its operation. Partially opened DELPHI particle detector. On the right is the main section with müon calorimeters, on the left the end-plug with some of the cabling for the 1 million data points. of the LEP Collider. This arrangement also dictates the configuration of the controller nodes. Working closely with CERN, ABB constructed nine local networks, each of which can be controlled independently of the others. The four largest and one smaller local network are also united in 2 a central control room with a wide array of displays 3, 4, 5, 6. Each of the four large installations generates about 2,400 to 2,900 I/O signals, which have to be monitored by the ABB system, and records data on 600 trend curves. Although approximately 40 curves would be sufficient to describe normal operation Flexibility is required These technical details underline both the extent and the complexity of the control duties that the ABB system has to perform, the main task being to control the cooling of the cavity resonators a process which can last 24 hours. To avoid the risk of thermal stress in the components, the temperature difference over critical parts of an installation is never allowed to exceed 50 C. Although the thermal inertia of the cooling system is high and the control processes are usually run for long periods of time the control system must be able to respond immediately to a sudden, unexpected malfunction, such as quenching (ie, a loss of superconductivity). In such an event, the cooling circuits have to be interrupted quickly to avoid an excessive build-up of pressure. The response times for the switching Overview of the cryogenics at LEP site 2. At top left is the compressor section, top right the upper (300 to 20 K) and lower (20 to 4 K) cold box, and below the load, consisting of the superconducting accelerating cavities. 3 Cryogenic installation (upper and lower cold box). The helium is liquefied from 20 C at 20 atm to 4.2 K by means of expansion turbines. 4 20 ABB Review 5/1999

stage of the helium liquefier at LEP site 2. Five parallel compressors belonging to the low-pressure section are shown on the left. The inset shows tanks holding helium gas in reserve at normal temperature. 5 Upper cold box, in which turbines expand the helium, thereby cooling it from 300 K to 20 K. 6 operations in the cooling circuits are measured in minutes or seconds, whereas the radio frequency of the particle accelerator has to be switched off within just milliseconds. Less than 2 kw of energy are needed to cool the lines and compensate for the heat losses; 10 kw is necessary to dissipate the heat in the resonators (ie, the heat caused by the radio frequency energy and the particle beam). The quality of the helium also has to be routinely checked. Contamination has to be kept to an absolute minimum no more than a few non-helium atoms per million helium atoms are allowed. The process control system therefore controls the purification of the helium, which has the lowest boiling point of any gas. This function is important since the contamination could crystallize and be deposited on the valves and turbine blades, in which case the turbines, which have gas bearings, would be destroyed. As already mentioned, the overall process control system is so complex that several of the original MasterPiece 200 Lower cold box the helium is cooled from 20 to 4.2 K and liquefied. Valves control the turbine pressure. From here the liquid helium flows (under the effect of the pressure difference) to the resonator cavities. 7 Overview of the lower cold box. An Advant Controller 450 monitors the liquefaction of the helium gas. Three heat-exchangers are shown on the left. The object on the right is the liquefier. 8 ABB Review 5/1999 21

stations [1], for example those that control the compressors, were being run at their limit. In the meantime ABB has developed the Advant Controller 450 with four times the capability of the earlier controllers and which can be nominally expanded for 5,400 analogue and digital I/Os. This new system now replaces the MasterPiece 200 stations at critical nodes in the cooling system. With Advant OCS, the cooling system of the overall plant can be controlled from a central control room, the local control rooms only being used for maintenance work or in the event of failure of the link to the central control room. ABB Cryogenics Controls General Layout Networks, Nodes 23 SC Quads 27 CERN-Ethernet 21 25 OS-520, 1 S800 Purifier 6 IMS-515, 1 7 IMS-515, 2 8 MV850/1 4 24 49 LEP Point 2 Process Section 2 AF100 42 41 22 22 AC450/9.0 E 4 MG230/1 127 124 To Bldg. 36 via Optic Fiber/FDDI E Plant Network MB remote acce SPS-1/3 29 41 43 45 47 51 Object-oriented software The contract awarded to ABB was also the first for a complete process control project ever to have been awarded by CERN to a single industrial concern. Since the process control technology was intended for six similar installations originating from two different suppliers (in each case, two 12-kW cryogenic installations as well as one 6-kW cryogenic plant, primarily for test-rig work 7, 8 ), CERN and ABB decided in favour of object-oriented software. Close collaboration soon produced the hierarchical structures for the software components. At the lowest level, software elements control the least complex objects, such as valves, heating elements and pumps. At the next higher level are the objects formed by joining together the objects at the lowest level. Also here are the first horizontal interlock functions, eg representing a turbine by the three objects gas bearing, input valve and brake valve. Several of these objects can be joined together to form other installation parts, such as a compressor stage. Subfunctions, such as resonator cooling, are initiated at this level by the appropriate commands. Coordination of the sub- 43 63 SC Quads 83 Advant OS-520 (6, future) 69 47 67 87 41 61 81 45 65 85 44 LEP Point 4 Process Section 4 44 43 S800 Purifier 64 42 42 LEP Point 6 Process Section 6 AF100 46 45 84 62 62 AC450/9.0 LEP Point 8 Process Section 8 82 82 system interaction 9 takes place at the ing the further development of its process highest level, eg with commands such as begin cooling. control systems, as evidenced by the Advant controllers: the function-blockoriented graphic programming with the programming language AMPL, which had The benefits of system compatibility ABB s policy of ensuring system compatibility has continued to pay dividends duralready been in use for some time, allows 98 % of the user-programs to be transferred unchanged to the advanced AC400 controller series. Another advan- 48 Configuration of the Advant Open Control System installed in CERN s laboratory for particle of the LEP particle accelerator. 47 E E E 22 ABB Review 5/1999

-300(E) 124» ss 7 5 MG230/1 127 5 3 1 E planned 5 Building 36, RCCR 51 110 9 Fiberoptic Link (E) SPS-1/3, BB-40 21 local access SPS-1/3» 11 12 IMS-515, 3 OS-520, 2 22 Unit 1» CERN-Ethernet (TCP/IP) 24 Unit 3 CERN-Ethernet Building 35/3-007 SPS-1: Process Section 11 SPS-3: Process Section 12 ABB is currently testing the process control and drive systems in connection with the latest Profibus developments. The transfer of know-how between ABB and CERN testifies to the success of the collaboration and is one of the factors that speak for continuing the cooperation beyond the existing contracts and after tendering for the Large Hadron Collider (LHC), which will generate a particle energy of 7 TeV (1 TeV = 1,000 GeV) per beam, compared with 192 GeV for the LEP. SM-18 64 64 Purifier AL 63 Coldbox AL 6kW Linde, Process Section 9 6kW AL, Process Section 10 Li/Linde OS-520, 3 AL/Air Liquide SH-18 71 69 61 5 56 56 73 62 72 AC450/9.0 Coldbox Li AL Li Reference [1] S. Fors: ABB Master controls cryogenic installations for the world s largest particle accelerator. ABB Review 8/9-90, 3 10. [2] CERN Annual Report 1998, vol 1. Hall 163, SC Cable Test Area Process Section 13 Station Colour Identification MV830/1 OS-520, 4 Process Control Station, AC410 Process Control Station, AC450 S800/AF100 Extension 53 33 AC410/7.0 CC 31 39 35 AC410/7.0 CPR/CG 53 32 34 Process Control Station, MP200 Local Supervisory Station IMS/OS Supervisory Station Site Colour Identification Hall 180, ATLAS Components Test Area Process Section 14 MV830/1 OS-520, 5 In regular use SM18 Network, in regular use Test Site, Office Building 35 LHC Test Sites, Upgrades of 200/0 Installations 55 52 MP200/0->1 BOC 51 59 53 MP200/0->1 55 54 55 MP200/0->1 MP200/0->1 physics, where it controls and monitors the cryogenic installations 9 tage was the object-oriented software that ABB had introduced six years earlier and which allows applications to be programmed today for about a third of the cost then. The installation by CERN and ABB of what was virtually a turnkey process control system went smoothly and can be considered a great success. In the meantime ABB can access CERN s local Masternet directly, which makes further development of the software and fault analysis easier. Ongoing system optimization is ensured by holding conferences which are attended by members of the research center in Geneva and ABB personnel. At the suggestion of CERN engineers, Authors Hans-Karl Kuhn CERN, Centre Européen pour la Recherche Nucléaire CH-1211 Geneva Switzerland Telefax: +41 22 767 95 80 E-mail: hans-karl.kuhn@cern.ch Marco Pellin ABB Power Automation AG CH-5401 Baden Switzerland Telefax: +41 56 486 73 73 E-mail: marco.pellin@ch.abb.com ABB Review 5/1999 23