HA/HAB Fiberglass Wall Mount Ventilators

Similar documents
BCFS Belt Driven Centrifugal Filtered Supply Fans

BCRFS Belt Driven Centrifugal Filtered Supply Fans

Backward Inclined Hinged Restaurant Exhaust Fan

Electronically Commutated Motors

Centrifugal Square Inline Fans

Axial Roof Ventilators & Tubeaxial Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

Installation. Check, Test & Start Procedure

Upblast Propeller Roof Fans

INSTALLATION, OPERATION & MAINTENANCE MANUAL. Centrifugal Square Inline Fans

Centrifugal Square Inline Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

INSTALLATION, OPERATION & MAINTENANCE MANUAL Hooded Propeller & Tubeaxial Roof Fans. Models: LHB, LHD, LHBF, LHDF, THB, THD, THBF, THDF

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Propeller Wall Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL

Operating and Installation Instructions

Model C230 Pump Controller

Installation & Operation Manual Chef Base

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Air Curtain. Installation, Operating and Maintenance Instructions

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

APCO CSV-1600 SURGE CHECK VALVE

MODEL 7400 STRUT SPRING COMPRESSOR

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

Electromagnetic Particle Brakes Model: PRB-H

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

MODEL 7600 STRUT SPRING COMPRESSOR

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

INSTALLATION, OPERATION & MAINTENANCE MANUAL Propeller Wall Fans. Models: TCPE, WPB, WPD

Raydot LLC 24 Actuator (115 VOLT)

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

StormPro BA Series Sump Pump

ESE Series Cast Iron Sewage Pumps

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

LED LARGE WALL PACK (CUTOFF & STANDARD)

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

HP190SL Series Slimline Radon Fans

2SHE Series Direct-Drive Shutter Fans

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Kitchen Tech Series Air Curtain

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

Manual Transfer Switch

48" Vanguard Slant Wall and Cone Belt Drive Fans Installation & Operator s Instruction Manual

Owner s Manual & Safety Instructions

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

TSL and QSL Inline Centrifugal and Mixed Flow Fans

60 Series End-Mount Brake Instructions Standard Housing

Integrated Heating System

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Single Post Caliper Brake VC500

II DISTRIBUTION & SUBSTATION TYPE C

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

DeZURIK 2 20" BOS BUTTERFLY VALVES

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

Installation, Operation and Maintenance Manual

Model 90 Twin Control Unit

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

User s Manual and Operating Instructions

430B SERIES HORIZONTAL SPLIT CASE PUMP

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Installation Power Management Unit Battery Cables and Battery Harness

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

Installation Manual for Ecology

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

MityFlex Peristaltic Pump

48 Belt Drive Turbo with Tensioner Cone and Grill Fan Installation and Operators Instruction Manual

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

FADE Series Wall Axial Fans

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Swing Arm Magnifying Lamp

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Extension Boot System

& r"1aintef~ance. Your KENBAK-l computer is a quality instrument which is. should expect months or years of operation without significant

D-Series Blowers and Exhausters

Test Oven. Series 3600 and 3700

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Transcription:

HA/HAB Fiberglass Wall Mount Ventilators INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-3100 August 2015 Throughout this manual, there are a number of HAZARD S that must be read and adhered to in order to prevent possible personal injury and/or damage to equipment. Two signal words "" and "CAUTION" are used to indicate the severity of a hazard and are preceded by the safety alert symbol. Used when serious injury or death MAY result from misuse or failure to follow specific instructions. CAUTION Used when minor or moderate injury or product / equipment damage MAY result from misuse or failure to follow specific instructions. It is the responsibility of all personnel involved in installation, operation and maintenance to fully understand the Warning and Caution procedures by which hazards are to be avoided. Receiving The HA/HAB ventilator is shipped in two parts: 1. Fan housing assembly complete with fiberglass inlet venturi to the wheel and complete motor and drive assembly. 2. Flanged extruded aluminum louver assembly. Duct adapter and companion angles are shipped loose if unit is for inline application. Inspect cartons or crates carefully before signing a delivery receipt for the carrier. If any damage is apparent, note it on the carrier s receipt so that a claim can be filed against the carrier through your usual channels. Handle the units carefully while delivering to installation location. Use ordinary care in unpacking the units. If the units, when unpacked, appear to be damaged in a way that could not be determined at the time of delivery, notify the carrier that concealed damage has been discovered and insist on inspection by the carrier. Obtain a copy of carrier s inspection report showing the concealed damages so that a claim can be filed through your usual channels. Study the attached installation prints carefully. Inspect the units carefully for identification marks, fan rotation symbols, etc. Installation Wall Application 1. Remove wood shipping supports from fan assembly (see Figure 1). 2. Locate and provide hole in the wall 1 2" larger than the fan housing (see Figure 2). This will provide an opening for the electrical wiring into the unit. 3. Anchor the box in the wall, keeping a minimum of 2 3 8" between the outside wall and any part of the box or the power assembly. 4. Fasten the flanged extruded louver to the exterior wall. Inline Application 1. Remove wood shipping supports from fan assembly (see Figure 1). 2. Attach duct adapter and companion angles to unit per Figure 3 with fasteners supplied. 3. Before anchoring the unit to the ductwork, check line voltage and current characteristics outlined in previous section. 4. Fasten the flanged extruded louver to the exterior wall wherever the outlet of the ductwork ends. For easy maintenance of the ventilator inline, provide a drop-out section between ductwork and duct adapter (see Figure 3). 1997 2018 Twin City Fan Companies, Ltd.

Check, Test & Start Procedure Electric shock hazard. Could cause severe injury or death. Failure to bond the frame of this equipment to the building electrical ground by use of the grounding terminal provided or other acceptable means may result in electrical shock. Disconnect electric power before servicing equipment. Service to be performed only by qualified personnel. 1. Check to verify that the wheel is free to rotate. 2. Verify that supply voltage on the line side of disconnect agrees with voltage on unit identification plate and is within the utilization voltage range as indicated in Table 1. 3. On three-phase units check and calculate phase unbalance as follows: % Voltage Unbalance = 100 x max. voltage deviation from avg. voltage avg. voltage Given example: With voltage of 220, 216 and 213 How To Use The Formula: a. Avg. Voltage = 220 + 216 + 213 = 649 3 = 216 b. Max. Voltage Deviation From Avg. Voltage = 220 216 = 4 c. % Voltage Unbalance = 100 x (4 216) = 1.8% Voltage unbalance should not exceed 2%. 5. Electrical Input Check: Perform check of fan ampere draw and verify that motor nameplate amps are not exceeded. Take account of the service factory range if motor is nameplated above a 1.0 service factor. 6. Fan RPM Check: Fan RPM should be checked and verified with a tachometer. Refer to Table 2 for maximum fan RPM values. Running fan at an RPM greater than the maximum RPM value in Table 2 will overload the fan motor and lead to premature motor failure. Table 2. Maximum Fan RPM (Belt Driven Units) MODEL HAB MOTOR HP MAXIMUM FAN RPM 12HA1B, 2B, 3B 1/4 1738 14HA1B, 2B, 3B 1/4 1468 14HA4B 1/3 1615 14HA5B 1/2 1849 18HA1B, 2B 1/4 945 18HA3B 1/3 1040 18HA4B 1/2 1191 18HA5B 3/4 1363 24HA1B 1/4 575 24HA2B 1/3 633 24HA3B 1/2 725 24HA4B 3/4 830 24HA5B 1 913 30HA1B 1/3 436 30HA2B 1/2 500 30HA3B 3/4 572 30HA4B 1 630 30HA5B 1 1 /2 721 30HA5B 2 793 Table 1. Utilization Voltages SYSTEM VOLTAGE/ UTILIZATION VOLTAGE UNIT NAMEPLATE MIN. MAX. 115/60/1 104 127 208-230/60/1 or 208-230/60/3 187 253 230/60/1 or 230/60/3 207 253 277/60/1 249 305 200/60/3 180 220 380/60/3 342 418 460/60/3 414 506 575/60/3 517 633 110/50/1 99 121 220/50/1 198 242 380-415/50/3 342 456 440/50/3 396 484 4. Apply power to unit and check rotation of wheel with the directional arrow on the unit. Especially check three-phase units for rotation. For three-phase, rotation can be changed by interchanging any two of the three line leads. If the unit is checked on temporary wiring, it should be rechecked when permanently installed. Motor burn-out or tripped overload protection devices are usually the result of wrong rotation. Maintenance General Fan shaft bearings on belt drive units are factory lubricated and require no lubrication for the first 3-6 months of operation. Lubricate at intervals shown in Table 3 thereafter. With fan running and with a low pressure grease gun, add grease slowly until a slight bead forms between the seals. Use Sinclair Litholene, Shell Gadus S2 V100 2, Socony Vacuum Armvac 781, Sinclair Oil Stranolith 57 or equal. Table 3. Bearing Lubrication Interval (Belt Drive Model HAB Only) OPERATING CONDITION FAIRLY CLEAN MODERATE TO EXTREMELY DIRTY GREASING INTERVAL 6 to 12 Months 1 Month 1. Frequency or regreasing will vary, depending on the hours of operation, temperature and surrounding conditions. 2. Bearings have been prelubricated from factory with NLGI Grade No. 2 lithium-12 hydroxysterate base grease. Belts on belt-drive units should be readjusted after 24 hours of operation. Loosen motor base bolts and apply 15 lbs. pull per belt for proper belt tensions. Tighten motor base bolts. Check contact surfaces of belt for excessive wear. If belts have a slick, glazed look or are cracked, belts are slipping. Replace belts as required. 2 Twin City Installation and Maintenance Manual IM-3100

Motors require no lubrication for 10 years of normal operation. The inlet venturi is molded shock-resistant, bonded, reinforced fiberglass and will require no maintenance. Wall Application 1. Servicing or inspecting the unit can be accomplished from the exterior by removing the flanged extruded louver and from the interior of the building by removing the fiberglass inlet (see Figure 2). 2. To remove the motor assembly for servicing, unplug the motor from the provided outlet and unfasten the four vibro-isolator bolts. The entire motor assembly, including the wheel and bearing (belt drive units), will slide out of the housing. Figure 1. Removal of Wood Shipping Supports Housing Inline Application For easy maintenance of the inlet unit, provide a dropout section between the ductwork and duct adapter (see Figure 3). Servicing or inspection can then be accomplished by removing the dropout section, then removing the fiberglass inlet. The motor assembly can then be removed by disconnecting the motor from the provided outlet and unfastening the four vibro-isolator bolts. Periodic inspection and cleaning of the fan will insure smooth operation. Instructions: Remove wood shipping supports frame before installing unit. Figure 2. Wall Application Electrical Wiring By Others Hole Provided for Electrical Entrance Into Unit Electrical Junction Box With Outlet Belt Drive Motor Louver Fan Housing Direct Drive Motor Trim Angle Fiberglass Inlet Venturi Access To Power Pack of Ventilator By Removing 4 Fasteners (Interior Side) or Louvers (Exterior Side) Twin City Installation and Maintenance Manual IM-3100 3

Figure 3. Inline Application Louver on Exterior Wall Wiring By Others Ductwork By Others Duct Adaptor (Shipped Loose With Fasteners) Ductwork By Others Companion Angles (Shipped Loose) With Fasteners) Access to Power Pack of Inline Unit By Removing 4 Fasteners Dropout Section of Duct For Easy Maintenance (By Others) 4 Twin City Installation and Maintenance Manual IM-3100

MAINTENANCE Location Serviced by Job Name: Organization: Address: Address: City / State / Zip: City / State / Zip: Telephone: ( ) Telephone: ( ) Contact: Contact: Fan Nameplate Information Motor Nameplate Information Model: HP Rpm Volts Serial #: Phase Hz Amps (FLA) Tag/Mark: Mfr: Model: Location: Frame Enclosure Date Installed: Thermal Protection: Yes No Air Volume: Design CFM Power Supply Volts Fan Rpm: Actual CFM (actual) Drives: Motor Sheave Bushing Turns Open Fan Sheave Bushing Belt Qty Date Done By Notes MAINTENANCE RECORD Refer to page 2 for recommended maintenance. Seller warrants to the original purchaser that the goods sold hereunder shall be free from defects in workmanship and material under normal use and service (except in those cases where the materials are supplied by the buyer) for a period of one year from the date of original installation or eighteen (18) months from the date of shipment, whichever occurs first. The liability of seller under this warranty is limited to replacing, repairing, or issuing credit (at cost, F.O.B. factory and at seller s discretion) for any part or parts which are returned by buyer during such period provided that: a. seller is notified in writing within ten (10) days following discovery of such defects by buyer, or within ten (10) days after such defects should reasonably have been discovered, whichever is less; b. the defective unit is returned to seller, transportation charges prepaid by buyer. c. payment in full has been received by seller or said products; and d. seller s examination of such unit shall disclose to its satisfaction that such defects have not been caused by misuse, neglect, improper installation, repair, alteration, act of God, or accident. Limited Warranty No warranty made hereunder shall extend to any seller product whose serial number is altered, effaced or removed. Seller makes no warranty, express or implied, with respect to motors, switches, controls, or other components of seller s product, where such components are warranted separately by their respective manufacturers. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event shall seller be liable to buyer for indirect, incidental collateral, or consequential damages of any kind. (BUYER S FAILURE TO PAY THE FULL AMOUNT DUE WITHIN SIXTY (60) DAYS OF DATE OF INVOICE SHALL OPERATE TO RELEASE SELLER FROM ANY AND ALL LIABILITY OR OBLIGATION ARISING PURSUANT TO ANY WARRANTY, EXPRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE IN CONNECTION WITH ANY CONTRACT FORMED HEREUNDER. BUYER AGREES THAT SUCH FAILURE TO PAY SHALL CONSTITUTE A VOLUNTARY WAIVER OF ANY AND ALL SUCH WARRANTIES ARISING PURSUANT TO SUCH CONTACT.) Twin City Installation and Maintenance Manual IM-3100 5

TWIN CITY FAN & BLOWER WWW.TCF.COM 5959 Trenton Lane N Minneapolis, MN 55442 Phone: 763-551-7600 Fax: 763-551-7601