Assessment Report. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str Idstein

Similar documents
General Information. Installation Information Design Information Material Information Ordering Information

Fire Evaluation. From the original report n Date: 09/12/2013

Pure110-PRO. System Components. Grades. General Information. Installation Information

System Components. Grades. General Information Installation Information

T.I. Midwood Co Ltd Green Lane Wardle Nantwich Cheshire CW5 6BJ T: +44 (0) F: +44 (0)

Trutek TCM 385RE - Pure Epoxy 3:1

HSA Carbon steel HSA-F Carbon steel hot-dipped galvanised with DIN 125 washer. HSA-R Stainless steel A4. HSA-BW Carbon steel with DIN 9021 washer

Tested fasteners for passive structural fire prevention

Polyfixer PSF. Features and Benefits Version: 14/04/2015

BUFFALO - XP. A StongFast Product. For more information call Or log on to

EJOT Multifix VSF. EJOT Baubefestigungen GmbH In der Stockwiese BAD LAASPHE Germany

FEATURES APPLICATIONS. Technical data sheet VAS - VAS THREADED ROD. VAS Threaded Rod for use with the VAC Capsule System. UK-DoP-e13/0937, ETA-13/0937

HIGH PERFORMANCE STEEL ANCHORS

fischer Bolt anchor FAZ II The power anchor for highest demands.

Munich Fire Tests on Membrane Action

VF22PRO CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM

fischer Bolt anchor FAZ II

MULTI-MONTI -plus THE NEW MULTI-MONTI WITH THE BIG PLUS

DECLARATION OF PERFORMANCE. No EN

EF500R CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM

Zykon Bolt anchor FZA, zinc-plated steel. Zykon Internallythreaded. FZA-I, zinc-plated steel Zykon Through anchor FZA-D, zinc-plated steel

fischer Highbond FHB II

European Technical Assessment ETA-09/0355 of

Declaration of Performance

European Technical Assessment ETA-13/0900 of 10/04/2014

TECHNICAL DATASHEET SITA ACCIAIO CE 1 steel wedge anchor for cracked and non-cracked concrete

(English language translation, the original version is in French language) Upat Bolt

JF375E JF300E JMN150E. Load Time T load (hrs) Range Data. Maximum Fixture Thickness. Drill Hole Diam.

Blue-Tip Screwbolt BT

fischer Hammerset anchor EA II

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. Zinc-plated steel Stainless steel Hot-dip galvanised steel

Centre Scientifique et Technique du Bâtiment 4, avenue du Recteur Poincaré F PARIS Cedex 16 Tél. : (33) Fax : (33)

Bolt FBN The heavyweight.

VERSIONS. zinc-plated steel stainless steel highly corrosion-resistant steel BUILDING MATERIALS

(English language translation, the original version is in French language) FM 753

EJOT ECOset HTK 2G Cordless Installation System to Secure Roofing Membrane on Flat Roofs. The Quality Connection

(English language translation, the original version is in French language) PFG expansion bolt type LB, ES and SB

Chemical fixing threaded rod

Declaration of Performance DoP MOVISE-en

AZAM TECHINICAL DATASHEET ZA-CA ZA-TO ZA-TL ZA-AR ZA-PR ZA-ES ZA-GA ZA-AF ZA-GF APPLICATION EXAMPLES

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

weinor can hold you the safe, fast way to fix it properly

MITRAS MATERIALS GMBH

H Window Company, LLC Super-insulating Windows and Doors th Avenue West Ashland WI Phone: Fax:

Anchor bolt FAZ II Millionfold proven anchor bolt and the strongest in its class.

WP5 - Computational Mechanics B5 - Temporary Vertical Concrete Safety Barrier MAIN REPORT Volume 1 of 1

fischer bonded anchor systems for cracked concrete Three systems one goal the maximum performance

DICHIARAZIONE DI PRESTAZIONE No. HSL-3, HSL-3-R_B-1109-CPR-0002

LIFTPARKER N4100 S/D. The best solution for. ceiling heights below 3m

Designated according to Article 29 of Regulation (EU) No 305/2011

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

MFPA Leipzig GmbH Test, monitoring and certification point for building materials, products and systems

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

Evidence of performance Reduction of impact sound pressure level by floor coverings

ENERCON GmbH ENERCON E-66. page 1 of 6. Design. Dreekamp 5 Tel.: / Aurich Fax: / Design

fischer Product Range Direct Fastening

Sound-absorbing spacer Sorp10

Industry Best Practices in Reliability Prediction and Assurance for Power Electronics: Part 1 - Reliability of Power Electronics Components

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

TYPE-CERTIFICATE DATA SHEET

Report for CSP Joint Venture Click to edit Master text styles Second level Third level. Fifth level

Construction. High-performance, 2-part epoxy anchoring adhesive. Product Description. Tests. Product Data Sheet Edition _1

FIXING SYSTEMS. TECHNICAL MANUAL Fixing Systems Terwa reserves the right to make changes to the documentation at any time Page 1

TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies. Test Report

Load capacity charts

so increased accessibility

Review Paper on Design and Development of Coupling Torque Endurance Test Machine with Variable Torque and Chamber Adjustment

IZJAVA O SVOJSTVIMA. HECO-DoP_ETA_15/0784_MMS-plus_1804_HR

BEHAVIOR OF TENSILE ANCHORS IN CONCRETE: STATISTICAL ANALYSIS AND DESIGN RECOMMENDATIONS. Mansour Shirvani, B.S. Thesis

New measuring track curve in Wegberg-Wildenrath test and validation centre

Test report no

ANCHORS AND FIXING SYSTEMS EDITION 1

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Test report. About the effect of Lambda System Cleaning Products. No

DFO STATEMENT OF NEED REPORT

VDZ-Service portfolio Concrete and mortar

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

5 Project Planning for Gear Units

Construction. Product description:

Quadro Outdoor T2 S/D

Polymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened

Process Filtration From Pure to Sterile

Comprehensive analysis energy efficiency of large buildings / halls Summary

HYDAC Fluidtechnik: Industrial Valves FLOW CNTROL VALVE COMPENSATED PRESSURE VP-SR X.XXX.0/01.09 E / D E /08.

EXPERIMENTAL STUDY ON EFFECTIVENESS OF SHEAR STRENGTHENING OF RC BEAMS WITH CFRP SHEETS

Hilti HST Submission Folder

Summary of the project SWD th November Project duration June 2015 to December Edited by

A High tech Fibre Material ideal for strong alkali media and steam

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

STOREPARKER SERIES STOREPARKER N2503 THE DEPENDENT PARKING SYSTEM ON 3 LEVELS WITHOUT PIT DEPENDENT PARKING SYSTEMS

Han Q 1/0 Axial Screw Protected. Available February 2017

GROUPCODE NEN : ANSI : STEEL BS : STEEL

Technical information No. 01. IT systems. The basis for reliable power supply

EIPS2 INTERNAL GEAR PUMPS

SOUTH AFRICAN NATIONAL STANDARD

European Technical Approval ETA-10/0198

CERTIFICATE OF ACCREDITATION

Report on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El

ANCHORS AND FIXING SYSTEMS EDITION 1

Unerwünschtes strömungsinduziertes Pfeifen von Ladeluft-Resonatoren von der Theorie über die Messung und Simulation zur Lösung

Transcription:

Assessment Report Project 21827 condensed version Assessment of resistance under fire exposure of the Injection System AC200+ Employer Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str.11 65510 Idstein Date 31.3.2018 Pages 10 Author UNTERER SOMMERWALDWEG 1 66953 PIRMASENS TRAGWERK@INGENIEURBUEROTHIELE.DE TEL. 06331 55470

PAGE 2 ASSESMENT REPORT 21827, 31.3.2018 Table of contents 1 General information... 3 2 Reference documents... 3 3 Product description... 4 4 Scope of evaluation... 4 5 Summary... 5

PAGE 3 ASSESMENT REPORT 21827, 31.3.2018 1 General information Stanley Black & Decker Deutschland GmbH authorized the evaluation of the fire resistance of the Injection System AC200+ for axial tension and shear loads. The evaluation in [1] is based on tests that were conducted by the Technical University Kaiserslautern under fire exposure according to DIN EN 1363-1:2012 [3] and Technical Report 020 [2]. The test results are summarized in test report 17027MR15552 [4]. This evaluation is only valid for one-sided fire exposure. 2 Reference documents [1] Gutachten 21737 vom 1.8.2017, Ingenieurbüro Thiele GmbH, deposited by the signee [2] Evaluation of Anchorages in Concrete Concerning Resistance to Fire, EOTA TR 020, Edition May 2004 [3] Feuerwiderstandsprüfungen Teil 1: Allgemeine Anforderungen, DIN EN 1363-1; Edition Oktober 2012 [4] Test Report 17027MR15552, TU Kaiserslautern, June 2017, deposited by the signee [5] Test Report 15025CT15541, TU Kaiserslautern, December 2016, deposited by the signee [6] Guideline for European technical approval of metal anchors for use in concrete, ETAG ETAG 001, Edition April 2013 [7] European Technical Approval ETA-16/0905: Injection System AC200+, EOTA, DIBt, 20 February 2017 [8] C. Thiele, M. Reichert: Qualifikation von Verbunddübeln im Brandfall, TU Kaiserslautern, DIBt, June 2017

PAGE 4 ASSESMENT REPORT 21827, 31.3.2018 3 Product description The Stanley AC200+ adhesive is a bonded anchor system consisting of a plastic cartridge containing the injection mortar and a steel part. The injection system AC200+ is designed for the use in concrete according to the European Technical Assessment ETA-16/0905[7]. 4 Scope of evaluation The present evaluation of fire resistance for Injection System AC200+ in concrete is assessed with respect to its fire resistance properties for anchor applications in walls and ceilings. The tests which this evaluation refers to, are executed with vertical arranged anchors and axial load application. Furthermore, the anchors were exposed to the standard temperature-time curve (ETK) [3]. In the tests a fixture according to TR020 was used, therefore the following fire resistances cover only anchors protected from fire by attachments similar to the fixture according to TR020 [2]. The assessment of steel failure and concrete cone failure is carried out in dependence on TR020 [2]. Additionally the failure type pullout failure is assessed as explained in below. a. Steel failure: Steel failure is assessed according to TR020 [2]. In some cases several anchor size is assessed together b. Pullout failure: Pullout failure is assessed by the current state of scientific knowledge according to the research report Qualifikation von Verbunddübeln im Brandfall [7]. A combination of thermal simulation and assessment of test results was used. c. Concrete cone failure: Concrete cone failure is assessed according to TR020 [2]. The fire resistances given in chapter 5 covers axial loads and shear loads as well.

PAGE 5 ASSESMENT REPORT 21827, 31.3.2018 5 Summary Table 5-1 to Table 5-4 show the fire resistances for the use of Injection System AC200+ for use in cracked and uncracked concrete. The given fire resistances covers axial and shear loads. The listed fire resistances are valid for single anchors with an edge distance of more than ccr=2 hef and a spacing to the adjacent anchor of s= 2 ccr= 4 hef. Edge distance and spacing distances have to be chosen so that steel or pullout failure is decisive. The values below are valid for the use of carbon steel (minimum grade 5.8 acc. to ISO 898-1), stainless steel (acc. to EN 10088, minimum grade 70 acc. to ISO 3506) or high corrosion resistant steel (HCR acc. to EN 10088, minimum grade 70 acc. to ISO 3506) anchor rods. For the values highlighted in grey steel failure was decisive.

PAGE 6 ASSESMENT REPORT 21827, 31.3.2018 Table 5-1: Summary of the characteristic resistances for uncracked concrete, M8-M16 Anchorage depth h ef Anchor size Maximum tension laod N Rk,fi(t) [kn] depending on the fire resistance time 30 60 90 120 [mm] [mm] [min] [min] [min] [min] 60 0,71 0,56 0,14 0,14 65 0,71 0,56 0,29 0,15 70 0,71 0,56 0,41 0,16 75 M8 0,71 0,56 0,41 0,24 80 0,71 0,56 0,41 0,33 85 0,71 0,56 0,41 0,33 90 0,71 0,56 0,41 0,33 60 1,42 0,58 0,17 0,17 65 1,42 0,95 0,18 0,18 70 1,42 1,11 0,34 0,20 75 1,42 1,11 0,60 0,21 80 M10 1,42 1,11 0,79 0,28 85 1,42 1,11 0,79 0,52 90 1,42 1,11 0,79 0,63 95 1,42 1,11 0,79 0,63 100 1,42 1,11 0,79 0,63 70 3,03 1,15 0,24 0,24 75 3,03 1,71 0,40 0,25 80 3,03 2,28 0,72 0,27 85 3,03 2,28 1,12 0,32 90 M12 3,03 2,28 1,60 0,61 95 3,03 2,28 1,60 0,96 100 3,03 2,28 1,60 1,18 105 3,03 2,28 1,60 1,18 110 3,03 2,28 1,60 1,18 80 5,65 1,66 0,36 0,36 85 5,65 2,41 0,58 0,38 90 5,65 3,34 1,02 0,41 95 5,65 4,24 1,55 0,43 100 5,65 4,24 2,21 0,83 M16 105 5,65 4,24 2,98 1,29 110 5,65 4,24 2,98 1,86 115 5,65 4,24 2,98 2,20 120 5,65 4,24 2,98 2,20 125 5,65 4,24 2,98 2,20

PAGE 7 ASSESMENT REPORT 21827, 31.3.2018 Table 5-2: Summary of the characteristic resistance for uncracked concrete, M20-M30 Anchorage depth h ef Anchor size Maximum tension laod N Rk,fi(t) [kn] depending on the fire resistance time 30 60 90 120 [mm] [mm] [min] [min] [min] [min] 90 8,82 2,45 0,51 0,51 95 8,82 3,42 0,90 0,54 100 8,82 4,60 1,47 0,57 105 8,82 6,01 2,15 0,64 110 8,82 6,62 2,98 1,15 115 M20 8,82 6,62 3,98 1,75 120 8,82 6,62 4,66 2,46 125 8,82 6,62 4,66 3,30 130 8,82 6,62 4,66 3,43 135 8,82 6,62 4,66 3,43 140 8,82 6,62 4,66 3,43 95 12,71 2,52 0,64 0,64 100 12,71 3,54 0,73 0,68 105 12,71 4,76 1,35 0,71 110 12,71 6,23 2,07 0,75 115 12,71 7,97 2,93 0,95 120 12,71 9,53 3,96 1,59 M24 125 12,71 9,53 5,18 2,32 130 12,71 9,53 6,61 3,19 135 12,71 9,53 6,71 4,20 140 12,71 9,53 6,71 4,94 145 12,71 9,53 6,71 4,94 150 12,71 9,53 6,71 4,94 108 16,52 5,27 1,43 0,82 115 16,52 6,85 2,21 0,88 120 16,52 8,72 3,15 0,92 125 16,52 10,87 4,24 1,62 130 16,52 12,39 5,52 2,40 135 M27 16,52 12,39 7,02 3,32 140 16,52 12,39 8,72 4,39 145 16,52 12,39 8,72 5,66 150 16,52 12,39 8,72 6,43 155 16,52 12,39 8,72 6,43 160 16,52 12,39 8,72 6,43 120 20,20 7,62 2,42 1,02 125 20,20 9,62 3,41 1,06 130 20,20 11,91 4,58 1,68 135 20,20 14,53 5,94 2,52 140 20,20 15,15 7,53 3,50 145 M30 20,20 15,15 9,37 4,63 150 20,20 15,15 10,66 5,95 155 20,20 15,15 10,66 7,46 160 20,20 15,15 10,66 7,85 165 20,20 15,15 10,66 7,85 170 20,20 15,15 10,66 7,85

PAGE 8 ASSESMENT REPORT 21827, 31.3.2018 Table 5-3: Summary of the characteristic resistance for cracked concrete, M8-M16 Anchorage depth h ef Anchor size Maximum tension laod N Rk,fi(t), [kn] depending on the fire resistance time 30 60 90 120 [mm] [mm] [min] [min] [min] [min] 60 0,71 0,56 0,10 0,10 65 0,71 0,56 0,22 0,11 70 0,71 0,56 0,37 0,12 75 M8 0,71 0,56 0,41 0,18 80 0,71 0,56 0,41 0,32 85 0,71 0,56 0,41 0,33 90 0,71 0,56 0,41 0,33 60 1,42 0,44 0,13 0,13 65 1,42 0,71 0,14 0,14 70 1,42 1,07 0,25 0,15 75 1,42 1,11 0,45 0,16 80 M10 1,42 1,11 0,70 0,21 85 1,42 1,11 0,79 0,39 90 1,42 1,11 0,79 0,61 95 1,42 1,11 0,79 0,63 100 1,42 1,11 0,79 0,63 70 3,03 0,86 0,18 0,18 75 3,03 1,28 0,30 0,19 80 3,03 1,82 0,54 0,20 85 3,03 2,28 0,84 0,24 90 M12 3,03 2,28 1,22 0,46 95 3,03 2,28 1,60 0,72 100 3,03 2,28 1,60 1,04 105 3,03 2,28 1,60 1,18 110 3,03 2,28 1,60 1,18 80 5,65 1,25 0,27 0,27 85 5,65 1,81 0,44 0,29 90 5,65 2,50 0,76 0,31 95 5,65 3,36 1,16 0,32 100 5,65 4,24 1,65 0,62 M16 105 5,65 4,24 2,26 0,97 110 5,65 4,24 2,98 1,39 115 5,65 4,24 2,98 1,90 120 5,65 4,24 2,98 2,20 125 5,65 4,24 2,98 2,20

PAGE 9 ASSESMENT REPORT 21827, 31.3.2018 Table 5-4: Summary of the characteristic resistance for cracked concrete, M20-M30 Anchorage depth h ef Anchor size Maximum tension laod N Rk,fi(t), [kn] depending on the fire resistance time 30 60 90 120 [mm] [mm] [min] [min] [min] [min] 90 8,82 1,84 0,38 0,38 95 8,82 2,56 0,67 0,40 100 8,82 3,45 1,10 0,42 105 8,82 4,51 1,61 0,48 110 8,82 5,77 2,24 0,86 115 M20 8,82 6,62 2,99 1,31 120 8,82 6,62 3,89 1,84 125 8,82 6,62 4,66 2,47 130 8,82 6,62 4,66 3,23 135 8,82 6,62 4,66 3,43 140 8,82 6,62 4,66 3,43 95 10,16 1,89 0,48 0,48 100 12,48 2,66 0,54 0,51 105 12,71 3,57 1,01 0,53 110 12,71 4,67 1,55 0,56 115 12,71 5,98 2,20 0,71 120 12,71 7,49 2,97 1,19 M24 125 12,71 9,25 3,89 1,74 130 12,71 9,53 4,96 2,39 135 12,71 9,53 6,22 3,15 140 12,71 9,53 6,71 4,05 145 12,71 9,53 6,71 4,94 150 12,71 9,53 6,71 4,94 108 16,52 3,95 1,07 0,62 115 16,52 5,13 1,66 0,66 120 16,52 6,54 2,36 0,69 125 16,52 8,15 3,18 1,22 130 16,52 9,99 4,14 1,80 135 M27 16,52 12,09 5,26 2,49 140 16,52 12,39 6,58 3,29 145 16,52 12,39 8,10 4,24 150 16,52 12,39 8,72 5,32 155 16,52 12,39 8,72 6,43 160 16,52 12,39 8,72 6,43 120 20,20 5,72 1,81 0,76 125 20,20 7,21 2,56 0,80 130 20,20 8,93 3,43 1,26 135 20,20 10,90 4,46 1,89 140 20,20 13,13 5,65 2,62 145 M30 20,20 15,15 7,03 3,47 150 20,20 15,15 8,61 4,46 155 20,20 15,15 10,41 5,59 160 20,20 15,15 10,66 6,90 165 20,20 15,15 10,66 7,85 170 20,20 15,15 10,66 7,85

PAGE 10 ASSESMENT REPORT 21827, 31.3.2018 Pirmasens, 31.3.2018 Jun.-Prof. Dr.-Ing. Catherina Thiele Dipl.-Ing. Marie Reichert