CENTRIFUGAL FAN COIL UNIT VCE

Similar documents
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

FCC DUCTABLE AIR TREATMENT UNIT

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Carisma The Ultra Quiet Fan Coil

NFCC Hydronic Terminal. Unit Description. Availale Models

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

FCX TECHNICAL BOOKLET

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units MAJOR 2 CV/CH

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

BRIZA 22 HYBRID HEATING & COOLING

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Highline 260i EC Waterside Fan Coil Unit

Concealed Ducted Split Series R22

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

The World Leading Air-conditioning Company

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

Total cooling capacity kw Total heating capacity kw Features

Fan coils with Inverter Brushless motor (EC) Concealed installation

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

TECHNICAL MANUAL SOFFIO Ducted units

WATER SOURCE HEAT PUMPS

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

AHN 064 to 304 EHN/CHN 064 to 304

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 1.0 kw to 7.6 kw

BASTONE (dual) fancoil Units

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Ductable water unit FWD UNT-PRC002-E4

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

Product Catalogue ARMONIA Providing indoor climate comfort

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

something new in the air Technical Bulletin

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

GUIDE SPECIFICATIONS. ES Series R-410A

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

ZEFIRO. The new dual discharge air cooler AIR HEAT EXCHANGER MANUFACTURER. stefani-online.it

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

CLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

(Thin) (Ultrathin) Suspended Air-handling Unit

VENTILCONVETTORI FAN COIL UNITS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Silent centrifugal air heater hot water supply

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

High Static Pressure Duct Fan Coil Unit

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

CHP

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

CLIMA-ZONE TERMINAL UNIT FOR HEATING AND COOLING MULTIPLE ROOMS. Ductable EC system, by constant pressure zones

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

D M S 760 C01 A A 1 1

Transcription:

CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h

VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical Compact, slim fan coil units. Available in 12 different sizes and 3 versions to satisfy all installation requirements. Wall mounted or floor mounted type with supporting feet, with bottom or front air intake. Horizontal ceiling mounted type, with rear or bottom air intake. Vertical wall recessed type, with top or front air outlet; horizontal ceiling concealed type with front air discharge. version available with feet VCEx8 VCEx5 VCEx4 VCEx9 vertical with cabinet Air intake: bottom vertical vertical with cabinet Air intake: frontal vertical horizontal with cabinet Air intake: frontal horizontal horizontal with cabinet Air intake: rear horizontal Unit with air intake socle Unit with terminal board Unit with terminal board 360 INDOOR CLIMATE SOLUTIONS

VCEx1 VCEx7 VCEx2 VCEx3 horizontal with cabinet Air intake: frontal horizontal Unit with terminal board Unit with air intake socle vertical concealed frontal Unit with terminal board vertical concealed frontal Unit with terminal board horizontal concealed horizontal Unit with terminal board www.aliseogroup.com

VCE STRUCTURE Galvanized steel sheet (8/10 mm thick) insulated in all parts in direct contact with the conditioned air. Insulated condensate tray made of galvanised steel sheet, complete with drain plug for complete drainage. Sides with knock-outs for fast fixing of accessories. Wallanchoring slots for easy fixing and levelling of the unit. BLOWER SECTION Double-inlet centrifugal fans with statically and dynamically balanced horizontally-oriented aluminium impellers. Single-phase asynchronous electric motor with overload cutout. 6 speeds of rotation (3 connected). The motor is directly coupled to the fans and cushioned with flexible mountings to ensure low noise. The unit can be equipped with variable speed EC motor, controlled by a proportional signal 0-10 V. AIR FILTER Filtering honeycomb polypropylene fabric enclosed within a metal frame to facilitate withdrawal and cleaning. Filtering rate of the standard model: EU1. Available with different filtering rate on request. DECORATIVE CABINET Modern design that blends in with any environment. Made in hot-dip galvanized steel sheet pre-coated with PVC to ensure high resistance to rust, corrosion, chemical agents, aliphatic solvents and alcohols. Air grilles made of ABS and the control panel protective flap are inserted in the cabinet top. Standard colour: white. Other RAL colours are available on request. CONTROL PANEL The control panel is integrated into the unit s design, covered by a flap. It s fitted as standard on vertical versions and it is equipped with mode selector (off/summer/winter) and speed selector. On request the unit can come with room thermostat, water low temperature thermostat or control panel with electronic thermostat. HEAT EXCHANGER Coils are made of copper pipe expanded into aluminium fins in continuos block. Brass headers with female fittings (GAS threads) and easily accessible air vents. In the standard version, the water connections are located on the left (when viewing the outlet). They may be supplied on the right on request. The unit can be supplied with: - 2-way valve package; - 3-way valve package with 4 connections. ACCESSORIES A wide range of options and accessories is available for complete requirement satisfaction: - heating coil for 4 pipe system; - cooling coil (4 rows or direct expansion); - temperature control with the 3-way or 2-way valve sets (on/off valves or modulating valves); - electric heaters; - external air intake with automatic or manual fresh air louver motor; - plenum; - lacquered wooden panel or sheet panel for cencealed versions; - Brushless motors with 0-10 V proportional signal. 360 INDOOR CLIMATE SOLUTIONS

10 20 30 40 50 60 70 80 90 100 110 120 Fans n 1 1 2 2 2 2 2 2 2 3 3 3 Standard coil Auxiliary coil External dimensions Internal dimensions Standard coil hydraulic connections Rows n 3 3 3 3 3 3 3 3 3 3 3 3 Fittings Ø 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Rows n 1 1 1 1 1 1 1 1 1 1 1 1 Fittings Ø 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Height H mm 480 480 480 480 480 480 585 585 585 602 602 602 Lenght L mm 660 860 1060 1060 1260 1260 1260 1460 1460 1660 1960 1960 Depth S mm 220 220 220 220 220 220 220 220 220 256 256 256 M mm 420 620 820 820 1020 1020 1020 1220 1220 1380 1680 1680 C mm 370 570 770 770 970 970 970 1170 1170 1330 1630 1630 D mm 395 595 795 795 995 995 995 1195 1195 1356 1656 1656 A mm 274 274 274 274 274 274 268 268 268 333 333 333 B mm 137 137 137 137 137 137 253 253 253 173 173 173 W mm 39 39 39 39 39 39 41 41 41 39 39 39 Z mm 109 109 109 109 109 109 107 107 107 141 141 141 E mm 337 337 337 337 337 337 374 374 374 395 395 395 Auxiliary coil F mm 67 67 67 67 67 67 124 124 124 120 120 120 hydraulic connections X mm 103 103 103 103 103 103 101 101 101 115 115 115 Y mm 53 53 53 53 53 53 52 52 52 62 62 62 Condensate drain fittings G mm 147 147 147 147 147 147 147 147 147 167 167 167 Net weight kg 14 17 22 23 27 28 30 35 36 46 55 57 GENERAL DIMENSIONS VCE 10 60 VCE 70 90 VCE 100 120* W X Z Y H L M D 180 C 110 B E F W X Z Y 3/4" 1/2" Ø 20 Y Z 3/4" 1/2" Ø 20 3/4" 1/2" Ø 20 G A B E F A W X B A E F 200 200 220 220 S S 234 S * Note: dimensions for models 100-120 referred to units with left side water connection www.aliseogroup.com

VCE 10 20 30 40 50 60 70 80 90 100 110 120 2 pipe system (3R coil) Total cooling capacity Sensible cooling capacity W max 860 1280 2170 2390 3110 3530 4100 5590 6900 7970 10000 11000 W med 790 1170 1940 1920 2790 3130 3510 5170 5960 6830 7690 9380 W min 670 1080 1450 1450 2200 2500 3080 4480 4830 6240 6020 6910 W max 740 1020 1760 1940 2180 2820 3150 3960 4820 6060 7910 8470 W med 650 900 1570 1530 1930 2450 2670 3620 4110 5120 5920 7120 W min 510 810 1200 1170 1500 1940 2300 3130 3290 4620 4580 5110 Water flow l/h max 148 219 372 433 534 606 694 959 1185 1367 1716 1888 Water pressure drop kpa max 0,9 2 6,3 8,8 16,1 25,9 37,6 27,9 19,1 26,6 21,5 26 Heating capacity W max 1250 1870 2590 3280 3660 4480 5140 6690 8130 10100 13100 13300 W med 1100 1650 2330 2640 3270 3940 4370 6180 6980 8540 9930 11200 W min 850 1470 1870 2110 2600 3120 3800 5360 5620 7770 7750 8150 Water flow l/h max 148 219 372 433 534 606 694 959 1185 1367 1716 1888 Water pressure drop kpa max 0,7 1,4 4,9 7,5 13,7 22 34,7 23,7 17,6 23,3 18,8 24,2 m 3 /h max 227 288 403 451 576 685 708 1057 1242 1354 2012 2003 Air flow m 3 /h med 189 244 352 344 495 579 577 950 1014 1040 1371 1510 m 3 /h min 136 209 270 263 360 429 489 786 769 969 987 1055 Sound power level Sound pressure level Power input db(a) max 46 45 44 47 47 52 52 60 64 63 67 66 db(a) med 41 41 41 40 43 47 46 56 58 57 58 61 db(a) min 33 39 34 33 37 38 42 51 51 55 50 53 db(a) max 37 36 35 38 38 43 43 51 55 54 58 57 db(a) med 32 32 32 31 34 38 37 47 49 48 49 52 db(a) min 24 30 25 24 28 29 33 42 42 46 41 44 W max 30 32 43 50 59 80 76 150 187 185 265 265 W max 23 27 36 35 48 59 59 130 150 140 215 230 W max 16 22 26 26 33 40 50 115 115 127 160 160 Absorbed current A max 0,18 0,25 0,28 0,28 0,45 0,45 0,44 0,96 0,95 0,97 1,27 1,25 Water content L - 0,59 0,93 1,27 1,27 1,61 1,61 2,42 2,93 2,93 3,28 4,04 4,04 - Standard unit with free outlet: external static pressure = 0 Pa - Sound power level: ISO 23741 - Sound pressure level: 8,6 db(a) lower that the sound power level for a room of 90 m 3 with a reverberation time of 0,5 sec. - Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7 C Outlet water temp.: 12 C Inlet air temp.: 27 C d.b. - 19 C w.b. Inlet water temp.: 50 C Inlet water temp.: 70/60 C 360 INDOOR CLIMATE SOLUTIONS

10 20 30 40 50 60 70 80 90 100 110 120 4 pipe system (3R+1R coil) Total cooling capacity Sensible cooling capacity W max 840 1230 2080 2380 2760 3690 4470 5350 6570 7710 9700 10700 W med 770 1130 1850 1900 2480 3260 3830 4950 5660 6590 7430 9060 W min 650 1040 1380 1440 1960 2610 3350 4280 4580 6050 5790 6650 W max 710 1120 1600 1930 2220 2910 3340 4110 5260 5860 7660 8200 W med 630 990 1430 1520 1960 2540 2830 3760 4470 4940 5720 6890 W min 500 890 1090 1160 1530 2000 2440 3260 3570 4470 4400 4920 Water flow l/h max 144 211 357 407 473 633 771 917 1128 1322 1663 1834 Water pressure drop kpa max 0,61 2 5,7 8,2 10,7 20 49,8 11,6 17 24,9 21,7 25,1 Heating capacity W max 1260 1890 2730 2890 3490 4140 5040 6210 7670 8380 10100 11400 W med 1110 1670 2450 2330 3120 3750 4290 5840 6580 7390 8160 10000 W min 860 1490 1970 1860 2450 3150 3710 5240 5300 6900 6750 9410 Water flow l/h max 111 166 239 253 306 363 442 545 673 735 886 1000 Water pressure drop kpa max 2,1 5,7 13,9 16,4 27,9 35,1 61,5 22 30 48,4 41,3 58,5 m 3 /h max 216 274 383 428 545 650 672 1003 1179 1289 1913 1905 Air flow m 3 /h med 180 231 333 326 469 548 549 901 962 1039 1304 1513 m 3 /h min 128 200 256 249 343 407 463 749 731 923 941 1004 Sound power level Sound pressure level Power input db(a) max 45 47 44 47 46 53 53 59 65 63 67 67 db(a) med 40 43 40 41 42 48 47 57 59 58 58 62 db(a) min 34 39 34 35 35 41 43 51 51 55 51 52 db(a) max 36 38 35 38 37 44 44 50 56 54 58 58 db(a) med 31 34 31 32 33 39 38 48 50 49 49 53 db(a) min 25 30 25 26 26 32 34 42 42 46 42 43 W max 30 32 43 50 59 80 76 150 187 185 265 265 W med 23 27 36 35 48 59 59 130 150 140 215 230 W min 16 22 26 26 33 40 50 115 115 127 160 160 Absorbed current A max 0,18 0,25 0,28 0,28 0,45 0,45 0,44 0,96 0,95 0,97 1,27 1,25 Water content (3R coil) L - 0,59 0,93 1,27 1,27 1,61 1,61 2,42 2,93 2,93 3,28 4,04 4,04 Water content (1R coil) L - 0,19 0,31 0,42 0,42 0,53 0,53 0,53 1,29 1,29 1,09 1,35 1,35 - Standard unit with free outlet: external static pressure = 0 Pa - Sound power level: ISO 23741 - Sound pressure level: 8,6 db(a) lower that the sound power level for a room of 90 m 3 with a reverberation time of 0,5 sec. - Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7 C Outlet water temp.: 12 C Inlet air temp.: 27 C d.b. - 19 C w.b. Inlet water temp.: 50 C Inlet water temp.: 70/60 C www.aliseogroup.com

VCE ECM: NEW SOLUTION New range of fan motors for fan coil application, with a very low power input. These type of motors, designed according to the latest technology and combined with a proper electronic control of stop and go status, allow an energy saving of a 50% compared to a standard motor. Consequently, we can forecast a CO2 emission which is 40/50% less than the one caused by a standard PSC motor whose speeds are given by a transformer and/or given by the winding. GENERAL FEATURES ECM motors are completely interchangeable with those of the already well known motors. Mechanical structure and cradles are in fact the same and the only difference is having replaced the transfomer with the electronic control case. Moreover, these motors have been designed to give a performance similar to the standard ones, but with the possibility of being used with a 0-10V control. TRY THE FUTURE By this type of fan motors, the users can be personalise the speeds according to their request, by means of any control which can easily be designed. This opens a new perspective to room air conditioning. In fact the fan coil manufacturer can program valves, motors and clutches by menas of the same logic, with the result that the final user can get an optimised system of room conditioning with a low CO2 impact. By using these type of motors, it is possible to satisfy the requirements of the ecodesign prescriptions suggested by Eurovent and is also in line with the future requirements, given a lower input power demand. CO2 PSC MOTOR CO2 EMISSION - 40/50 % CO2 WORK ECM MOTORS The basic explanation of a ECM motor s construction is that it is similar to a brushed motor, except everything is inside out and there are no brushes at all. The permanent magnets that would wrap around the armature in a normal motor are instead placed around the motor shaft, and this assembly is called the rotor. The wire coils are around the inside of the motor can, making several different magnetic poles. In a sensored ECM motor, there are sensors on the rotor that send signals back to the electonic speed control. ECM 360 INDOOR CLIMATE SOLUTIONS

10 9 8 Air flow (Fans 2x146x196) External Static Pressure 7 6 5 4 3 2 1 ECM operating range 0 0 100 200 300 400 500 600 700 800 900 Air flow 65% 60% Energy Saved by ECM 110 90 Absorbed power 55% 70 69 75 db(a) %W 50% 45% 40% 35% 30% 300 400 500 600 700 m 3 /h 70 60 50 40 30 20 10 W 50 30 10-10 8 31-58 % 13 44 19-57 % 230 336 454 643 848 ECM operating range 25 35 Noisiness 43 52 39-43 % 58 0 0 100 200 300 400 500 600 700 800 900 m 3 /h www.aliseogroup.com

VCE ECM MOTORS 20 40 60 70 90 100 120 2 pipe system (3R coil) W max 1280 2390 3530 4100 6900 7970 11000 Total cooling capacity W med 1170 1920 3130 3510 5960 6830 9380 W min 1080 1450 2500 3080 4830 6240 6910 W max 1020 1940 2820 3150 4820 6060 8470 Sensible cooling capacity W med 900 1530 2450 2670 4110 5120 7120 W min 810 1170 1940 2300 3290 4620 5110 Water flow l/h max 220 433 606 693 1184 1366 1888 Water pressure drop kpa max 2 8,8 25,9 37,6 19,1 26,6 26 W max 1870 3280 4480 5140 8130 10100 13300 Heating capacity W med 1650 2640 3940 4370 6980 8540 11200 W min 1470 2110 3120 3800 5620 7770 8150 Water flow l/h max 220 433 606 693 1184 1366 1888 Water pressure drop kpa max 1,4 7,5 22 34,7 17,6 23,3 24,2 m 3 /h max 288 450 685 708 1242 1354 2003 Air flow m 3 /h med 243 344 578 578 1014 1040 1510 m 3 /h min 210 263 429 489 769 969 1055 db(a) max 45 47 52 52 64 63 66 Sound power level db(a) med 41 40 47 46 58 57 61 db(a) min 37 33 38 42 51 55 53 db(a) max 36 38 43 43 55 54 57 Sound pressure level db(a) med 32 31 38 37 49 48 52 db(a) min 28 24 29 33 42 46 44 W max 12,5 17 32 42 146 64 200 Power input W med 9,5 11 20 23 66 43 116 W min 8 7 10 16,5 25 33 36 Input control voltage V - 2.5/3.4/4.5 3/4.5/6.4 3.2/5/6.6 4.7/5.8/7.6 4.4/6.8/9.6 4.2/4.7/6 3.5/6/7.5 - Standard unit with free outlet: external static pressure = 0 Pa - Sound power level: ISO 23741 - Sound pressure level: 8,6 db(a) lower that the sound power level for a room of 90 m 3 with a reverberation time of 0,5 sec. - Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7 C Outlet water temp.: 12 C Inlet air temp.: 27 C d.b. - 19 C w.b. Inlet water temp.: 50 C Inlet water temp.: 70/60 C 360 INDOOR CLIMATE SOLUTIONS

ECM MOTORS 20 40 60 70 90 100 120 4 pipe system (3R+1R coil) W max 1230 2380 3690 4470 6570 7710 10700 Total cooling capacity W med 1130 1900 3260 3830 5660 6590 9060 W min 1040 1440 2610 3350 4580 6050 6650 W max 1120 1930 2910 3340 5260 5860 8200 Sensible cooling capacity W med 990 1520 2540 2830 4470 4940 6890 W min 890 1160 2000 2440 3570 4470 4920 Water flow l/h max 211 407 633 771 1128 1322 1834 Water pressure drop kpa max 2 8,2 20 49,8 17 24,9 25,1 W max 1890 2890 4140 5040 7670 8380 11400 Heating capacity W med 1670 2330 3750 4290 6580 7390 10000 W min 1490 1860 3150 3710 5300 6900 9410 Water flow l/h max 166 253 364 442 673 735 1000 Water pressure drop kpa max 5,7 16,4 35,1 61,5 30 48,4 47,3 m 3 /h max 274 428 650 672 1179 1289 1905 Air flow m 3 /h med 231 326 548 549 962 1039 1513 m 3 /h min 199 248 407 462 731 923 1004 db(a) max 47 47 53 53 65 63 67 Sound power level db(a) med 43 41 48 47 59 58 62 db(a) min 39 35 41 43 51 55 52 db(a) max 38 38 44 44 56 54 58 Sound pressure level db(a) med 34 32 39 38 50 49 53 db(a) min 30 26 32 34 42 46 43 W max 12,5 17 32 42 146 64 200 Power input W med 9,5 11 20 23 66 43 116 W min 8 7 10 16,5 25 33 36 Input control voltage V - 2.5/3.4/4.5 3/4.5/6.4 3.2/5/6.6 4.7/5.8/7.6 4.4/6.8/9.6 4.2/4.7/6 3.5/6/7.5 - Standard unit with free outlet: external static pressure = 0 Pa - Sound power level: ISO 23741 - Sound pressure level: 8,6 db(a) lower that the sound power level for a room of 90 m 3 with a reverberation time of 0,5 sec. - Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7 C Outlet water temp.: 12 C Inlet air temp.: 27 C d.b. - 19 C w.b. Inlet water temp.: 50 C Inlet water temp.: 70/60 C www.aliseogroup.com

DP VCE 2014-0 GB A GROUP TAKES PART TO THE EUROVENT PROGRAM OF FAN COIL PERFORMANCE CERTIFICATION IN ORDER TO PROVIDE ITS CUSTOMERS THE RELIABILITY AND ACCURACY OF PERFORMANCES. A GROUP S.p.A. - Via Montegrappa, 67-31020 San Zenone degli Ezzelini (Treviso) - Italy Tel. +39 0423 567774 - Fax +39 0423 567985 - www.aliseogroup.com - info@ventilclima.com