Waveguide Directional Couplers. Cross Guide Couplers CC SERIES

Similar documents
Waveguide Load Terminations

Section 5. Directional Couplers. Introduction

Section 16. Short Slot Hybrids. Theory

Waveguide Flanges. Rectangular Flanges. Double Ridge Flanges F-D SERIES

Section 3. Rotary Joints. Introduction

FERRITE PRODUCTS TABLE OF CONTENTS

Microwave Isolators and Circulators

ABB SpA COMEM Operating Unit Power Grids Division Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

DATA SHEET NTC thermistors, accuracy line. BCcomponents

Oct 25, 2007 DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE

SC0715BL STANDARD BUZZER

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

PAGE# PAGE# PAGE# ADAPTERS * ROTARY JOINTS. * I Style 23 Broadwall 36 * L Style 24 Crossguide 37

PERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Pressure sensor for liquid and gaseous media QBE620-P...

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

GHz Standard Performance Dual Pole Parabolic Reflector Antenna

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

PRODUCT MANUAL BT SERIES

SMA Male Connector Solder Attachment for RG188-DS, RG316-DS

SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC BAND PASS FILTER PART NUMBER: CF RoHS ISSUED CHECKED CHECKED CHECKED APPROVED.

LMF / LMG RANGE ACCESSORIES CONTENTS

VHS... Screw Flow Meter

DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS

DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

CROSS FIELD ARRAY-2 (CFA-2) Long Throw/High Intelligibility All-Weather Loudspeaker System V100/2015

Transformer bushings, type GOA 250. Installation and maintenance guide

DETAIL SPECIFICATION SHEET

Red Thread IIA Primary Fittings (Product Data)

Backed and fully. supported by Fills. more power. 3 Year Warranty REV120815

MAINTENANCE NOTE: ANY LEAK FROM THE MAIN BODY OF THE LOAD IS AN INDICATION THAT THE UNIT SHOULD BE RETURNED TO THE FACTORY FOR REPAIRS.

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

For installation into ductwork

SafeGarment User s Guide SafeGarment

THE FASTEST CABLE TRAY SYSTEM

Air displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225

Mid to High Power FM Antennas

PS Powder Sieve Machine

BESTSELLER. Linear bushings. Product properties:

CAV controllers Type RN

BALL VALVES FILTERS TEST POINTS 8

Pressure Sensors. for liquid and gaseous media

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

High RF (HiRF) EMC Solutions Overview

BRIDGE HARDWARE (WHOLESALE SUPPLIES) Tel: Fax: PRODUCT GUIDE

7000 SERIES ROCKER AND PADDLE SWITCHES Overview

Description & Features: Applications:

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

SILENCERS. Contents. Page No. Features, Description, Sizes and Options. Performance Data. Submittal Data Request Sheet

Steel Hinges. Section 1 Page 1. LIGHT STEEL BUTT HINGES MHL Fixed Pin. MHL Loose Pin. STRONG STEEL BUTT HINGES MHL 15.

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

High Power Directional Coupler

Electrical Stability (ohm-cm, max.) Heat Aging Resistance After

ELAPSED TIME INDICATORS

Catalogue WOW! World of Weller

Nov 7, 2006 DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 9 SPECIFICATION ITEM: DIELECTRIC CERAMIC FILTER PART NUMBER: CF

Differential pressure gauge with reed switch Model: P680 series

TNC Series Series C TN 114

ELAPSED TIME INDICATORS

datasheet TCS-122 TCS-122DP

April Multilayer Directional Coupler. For MHz HHM2220SA3. 1.6x0.8mm [EIA 0603]* * Dimensions Code JIS[EIA]

HB IP65 Hood and Housing Series

Product Range Handbook

June 26, 2006 DIELECTRIC CERAMIC DUPLEX FILTER SPECIFICATION 1 OF 6 SPECIFICATION ITEM: DIELECTRIC CERAMIC DUPLEX FILTER PART NUMBER: CFDM

CCS Zone/Bypass Damper Assembly

CSB Series Broadband Motorized Coaxial Switches

Electric Switchboards

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Series Regulators - Pressure Reducing

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Insulation displacement terminals. OEC Product Catalogue

LMV RANGE CONTENTS. General information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL HS305

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

SERIES TAP-CHANGER

SPECIFICATION FOR APPROVAL

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only.

NTC Accurate Thermistors

Discharge oil capacity cm Discharge oil capacity. Max. stroke volume on retraction Remarks.

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)


SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF DOCUMENT CHECKED 9/28/11 DS 12/01/2011 TFG 12/01/2011 GL

GEZE SLIDING DOOR SYSTEMS

Kulka Military Class (A-A-59125) / (MIL-T-55164*)

R Z18 Series : SMB CARLOCK

DUMMY LOADS INTRODUCTION SPECIAL DESIGN

FAKRA Jack Right Angle Connector Crimp/Solder Attachment for RG174, RG316, RG188,.100 inch, PE-B100, PE-C100, LMR-100, White Color

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

Wide band isolators (Peripheral Mode) 1-3 // // 2-6 // // 2-18 // //4-12// 4-20// 6-21// 8-18

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

Series 7000 Torque Sensor for PTO-shafts

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

continuous use min hours (expected life time curve in addendum)

Insulated Crimp Terminals

Transcription:

Directional Couplers Cross Guide Couplers CC SERIES Broad Wall Couplers Side Wall Couplers DC SERIES SC SERIES

CROSS GUIDE COUPLERS (3PORT) Coupling Values: Nominal Coupling Values Accuracy V.S.W.R. 20 db ±5 db 1.32 max 30 db ±1 db 1.22 max 40 db ±1.5 db 1.06 max 10 db min, 20 db Typical A B C D 2.60 3.95 10 32 284 CC 10 AQB- (***-***)-B-(**) 334 204 36 229 3.30 4.90 11A 40 229 CC 11A AQB- (***-***)-B-(**) 288 153 31 212 3.95 5.85 12 48 187 CC 12 AQB- (***-***)-B-(**) 248 153 24 172 5.85 8.20 14 70 137 CC 14 AQB- (***-***)-B-(**) 192 102 17 141 7.05 10.0 15 84 112 CC 15 AQB- (***-***)-B-(**) 167 102 14 116 8.20 12.40 16 100 90 CC 16 AQB- (***-***)-B-(**) 141 76 12 103 10.0 15.0 17 120 75 CC 17 AQB- (***-***)-B-(**) 121 76 11 82 12.4 18.0 18 140 62 CC 18 AQB- (***-***)-B-(**) 111 76 9 73 18.0 26.5 20 220 42 CC 20 AQB- (***-***)-B-(**) 88 76 5 54 26.5 40.0 22 320 28 CC 22 AQB- (***-***)-B-(**) 79 57 5 54 *** For 3 Digit Rectangular Flange part number, refer to the Flange Catalogue, or consult the factory. Available in 20,30, and 40 db Coupling only. For other Coupling values contact the factory.

CROSS GUIDE COUPLERS (4 PORT) Coupling Values: Nominal Coupling Values Accuracy V.S.W.R. 20 db ±5 db 1.29 max 30 db ±1.5 db 1.17 max 40 db ±1.75 db 1.06 max 10 db min, 20 db Typical A B C 2.60 3.95 10 32 284 CC 10 BQB- (***-***)-B-(**) 204 204 36 3.30 4.90 11A 40 229 CC 11A BQB- (***-***)-B-(**) 153 153 31 3.95 5.85 12 48 187 CC 12 BQB- (***-***)-B-(**) 153 153 24 5.85 8.20 14 70 137 CC 14 BQB- (***-***)-B-(**) 102 102 17 7.05 10.0 15 84 112 CC 15 BQB- (***-***)-B-(**) 102 102 14 8.20 12.40 16 100 90 CC 16 BQB- (***-***)-B-(**) 76 76 12 10.0 15.0 17 120 75 CC 17 BQB- (***-***)-B-(**) 76 76 11 12.4 18.0 18 140 62 CC 18 BQB- (***-***)-B-(**) 76 76 9 18.0 26.5 20 220 42 CC 20 BQB- (***-***)-B-(**) 57 57 5 26.5 40.0 22 320 28 CC 22 BQB- (***-***)-B-(**) 51 51 5 *** For 3 Digit Rectangular Flange part number, refer to the Flange Catalogue, or consult the factory. Available in 20,30, and 40 db Coupling only. For other Coupling values contact the factory.

DIRECTIONAL COUPLERS (3 PORT) BROADWALL Coupling Values: Coupling Values Accuracy WG 10-18 10 db ±1.5 db WG 10-18 20 db ±1.5 db WG 10-18 30 db ±2.0 db WG 10-18 40 db ±2.0 db WG 20-22 As above ±2.0 db Return loss: Secondary Arm 27 db min. Flatness: ±1 db WG10-18 (Full band spec 35 db min over 75% of the bandwidth see table) WG20-22 30 db min over 50% of the bandwidth Directivity Return Minimum Loss (db) (Primary) (2). (db) A B C 2.60 3.95 10 32 284 DC 10 AQB- (***-***)-B-(**) 25 32 826 77 171 3.30 4.90 11A 40 229 DC 11A AQB- (***-***)-B-(**) 25 32 718 57 181 3.95 5.85 12 48 187 DC 12 AQB- (***-***)-B-(**) 25 32 635 51 153 4.90 7.05 13 58 159 DC 13 AQB- (***-***)-B-(**) 25 32 546 32 133 5.85 8.20 14 70 137 DC 14 AQB- (***-***)-B-(**) 25 32 554 43 127 7.05 10.0 15 84 112 DC 15 AQB- (***-***)-B-(**) 25 32 395 28 77 8.20 12.40 16 100 90 DC 16 AQB- (***-***)-B-(**) 25 32 287 33 67 10.0 15.0 17 120 75 DC 17 AQB- (***-***)-B-(**) 25 32 289 22 69 12.4 18.0 18 140 62 DC 18 AQB- (***-***)-B-(**) 25 32 249 19 60 18.0 26.5 20 220 42 DC 20 AQB- (***-***)-B-(**) 15 32 158 19 38 26.5 40.0 22 320 28 DC 22 AQB- (***-***)-B-(**) 15 32 162 19 35 *** For 3 Digit Rectangular Flange part number, refer to the Flange Catalogue, or consult the factory. Available in10, 20, 30 and 40 db Coupling values. Narrow band designs for 3, 6, 10 and 12 db are available, however other electrical and mechanical parameters may change. Please contact factory for details.

DIRECTIONAL COUPLERS (4 PORT) BROADWALL Coupling Values: Coupling Values Accuracy WG 10-18 10 db ±1.5 db WG 10-18 20 db ±1.5 db WG 10-18 30 db ±2.0 db WG 10-18 40 db ±2.0 db WG 20-22 As above ±2.0 db Return loss: (Secondary Arm 22 db) min. Flatness: ±1 db WG10-18 (Full band spec 35 db min over 75% of the bandwidth see table) WG20-22 30 db min over 50% of the bandwidth Directivity Return Minimum Loss (db) (Primary) (2). (db) A B C 2.60 3.95 10 32 284 DC 10 BQB- (***-***)-B-(**) 25 32 718 77 171 3.30 4.90 11A 40 229 DC 11A BQB- (***-***)-B-(**) 25 32 673 57 181 3.95 5.85 12 48 187 DC 12 BQB- (***-***)-B-(**) 25 32 566 51 153 4.90 7.05 13 58 159 DC 13 BQB- (***-***)-B-(**) 25 32 501 33 132 5.85 8.20 14 70 137 DC 14 BQB- (***-***)-B-(**) 25 32 467 43 127 7.05 10.0 15 84 112 DC 15 BQB- (***-***)-B-(**) 25 32 298 28 76 8.20 12.40 16 100 90 DC 16 BQB- (***-***)-B-(**) 25 32 163 33 67 10.0 15.0 17 120 75 DC 17 BQB- (***-***)-B-(**) 25 32 247 22 64 12.4 18.0 18 140 62 DC 18 BQB- (***-***)-B-(**) 25 32 206 22 60 18.0 26.5 20 220 42 DC 20 BQB- (***-***)-B-(**) 15 32 152 22 38 26.5 40.0 22 320 28 DC 22 BQB- (***-***)-B-(**) 15 32 127 16 38 *** For 3 Digit Rectangular Flange part number, refer to the Flange Catalogue, or consult the factory. Available in10, 20, 30 and 40 db Coupling values. Narrow band designs for 3, 6, 10 and 12 db are available, however other electrical and mechanical parameters may change. Please contact factory for details.

DIRECTIONAL COUPLERS (3 PORT) BROAD WALL (High Directivity) Mean Coupling: Coupling Sensitivity: Return loss: Body Material: ±0.5 db over the respective bandwidth for all standard coupling values ±0.75 db about the mean coupling value over the specified frequency band Secondary Arm 27 db min. Brass Directivity Return Minimum Loss (db) (Primary) (2). (db) A B C 2.60 3.95 10 32 284 DC 10 DQB- (***-***)-B-(**) 40 34 1753 76 173 3.30 4.90 11A 40 229 DC 11A DQB- (***-***)-B-(**) 40 34 1613 57 181 3.95 5.85 12 48 187 DC 12 DQB- (***-***)-B-(**) 40 36 1194 51 139 5.85 8.20 14 70 137 DC 14 DQB- (***-***)-B-(**) 40 40 1035 44 127 7.05 10.0 15 84 112 DC 15 DQB- (***-***)-B-(**) 40 33 737 28 76 8.20 12.40 16 100 90 DC 16 DQB- (***-***)-B-(**) 40 34 609 33 67 10.0 15.0 17 120 75 DC 17 DQB- (***-***)-B-(**) 40 35 584 22 63 12.4 18.0 18 140 62 DC 18 DQB- (***-***)-B-(**) 38 35 533 19 60 18.0 26.5 20 220 42 DC 20 DQB- (***-***)-B-(**) 35 30 432 19 38 26.5 40.0 22 320 28 DC 22 DQB- (***-***)-B-(**) 35 30 292 19 38 * Mean Coupling value is defined as the average coupling value (in db s) across the specified frequency range. *** For 3 Digit Rectangular Flange part number, refer to the Flange Catalogue, or consult the factory. High directivity designs shown are available in 10, 20, 30 and40db Please contact factory for further details.

Ordering Information DC16 A Q B 402 402 B 10 TYPE A = STANDARD, 3 PORT B = STANDARD, 4 PORT D = HIGH DIRECTIVITY, 3 PORT COUPLING VALUE 10= 10 db ( for Broadwall coupler) 20= 20 db ( for Broadwall & Cross Coupler) 30= 30 db ( for Broadwall & Cross Coupler) 40= 40 db ( for Broadwall & Cross Coupler) MATERIAL B= BRASS OUTPUT FLANGE SELECT THE REQUIRED FLANGE BY SELECTING THE LAST 3 DIGITS OF THE FLANGE PART No. E.g. 402= UBR FLANGE FLANGE TYPE (INPUT PORTS) SELECT THE REQUIRED FLANGE BY SELECTING THE LAST 3 DIGITS OF THE FLANGE PART No. E.g. 402= UBR FLANGE FINISH Z = UNPLATED (NON-STANDARD OPTIONAL FOR BRASS) A = TIN (OPTIONAL NON-STANDARD) B = SILVER (STANDARD) PAINT Q = BLUE (STANDARD) B = BLACK (OPTIONAL NON-STANDARD) G = GREY (0PTIONAL, NON-STANDARD) WAVEGUIDE SIZE USE THE BRITISH WG SIZE FOR RECTANGULAR WAVEGUIDE E.g. 16= WAVEGUIDE SIZE WG16 PRODUCT CODE DC = DIRECTIONAL COUPLER BROADWALL CC = CROSS GUIDE COUPLER SC = SIDE WALL DIRECTIONAL COUPLER Notes: 1) The flange should match the material of the device to remain standard. 2) Other coupling values between 3 & 60 db available on request. Commercial in Confidence