NRG 16-12, NRG 17-12, NRG 19-12

Similar documents
Level Electrode NRG NRG NRG NRG

Compact System NRGS 11-2 NRGS Original Installation Instructions English

GESTRA. GESTRA Steam Systems ZK 313 ASME. Installation Instructions Control Valve ZK 313 ASME

GESTRA. GESTRA Steam Systems MK 25/2 MK 25/2S. Installation Instructions Steam Traps MK 25..., DN 40-50

UNA 23 UNA 25 UNA 26 UNA 27

UNA 23 UNA 25 UNA 26 UNA 27

UNA 26h Stainless Steel Design. Installation Instructions Stainless Steel Steam Trap UNA 26h

NRG Installation Instructions Level Probe Type NRG A Siebe Group Product 1

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME

PRS 9. Installation Instructions Cycling Timer PRS 9. A Siebe Group Product 1

Condensate Drain Valve AK 45. Original Installation Instructions English

Conductivity Switch LRGS Original Installation Instructions English

Steam Trap MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

BB 1... BB 2... Installation and Maintenance Instructions Dual-Plate Check Valves BB 1..., BB 2...

PA 46 PA 47 MPA 46 MPA 47

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

DIAMOND POINT VIBRATING PROBES

Mounting and Operating Instructions EB 5868/5869 EN

M Series Condensate Recovery Unit

Supplementary instructions. Air cooling - FIBERTRAC 31 with Conduit tube connection. Active air cooling system for radiation-based sensors

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Operating Instructions Flexdip CYA112

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

FLENDER ARPEX plate packs with conical bolting. ARP Size Assembly instructions AN 4256 en 07/2016. FLENDER couplings

VE4000 & VE5000 SERIES

FLENDER couplings. FLENDER ARPEX plate packs with conical bolting. ARS-6 sizes to K430 sizes 235 to 820

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Water level controller and limiter

Operation & Maintenance Manual

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

These installation and maintenance instructions must be read in full and completely understood before the installation!

Kämmer Series Corrosive Application Valves

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting and Operating instructions

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

Instruction Manual. Sewage lifting station compli 300

Flameproof Level Sensor (Flameproof F/S FP)

OR 52-5 OR 52-6 Installation Instructions

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

ECHOTEL MODELS 915-P / 915-W

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Actuator size P2 P3 P4 P5 Diaphragm area cm Thrust max. dan Stroke mm

Stem Assembly Supplement

Mechanical seals external, single or double type Crane 58U 58U

Operating Instructions (Translation)

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Type 3320, Service Manual. Serviceanleitung Service Manuel

INSTALLATION AND OPERATING MANUAL Translation of the original manual. Series SCK. Mechanical Seal. double, to DIN EN Keep for future use!

Level Sensor with G1/2" Thread Hygienic

Bicolour level gauge. Type BU green/red. D-04-B EN-1 Edition 05/11

Level Sensor with M12 Thread Hygienic

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

NORI 320. Globe valves PN DN Applications. Standard variants. Operating data. Additional information. Materials.

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Capanivo Series CN 4000

Operating Instruction

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Operating Instructions

Single Phase Electronic Speed Controllers

Installation manual wall-mounted distributor

Worcester 53/54 Series. Reduced Bore Flanged Ball Valves to DIN 3202

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

Angle seat valve with diaphragm actuator VZXA-...-M

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C.

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Installation, Operation, and Maintenance Manual

Spare parts list Return line filter RFM with 2-hole attachment

Capacitive level sensors CLS 23

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

SITRANS P measuring instruments for pressure

High Pressure Valves Series Angle Valves Series Angle Valves

Worcester 18/19 Series. Modular Multi-Way Ball Valves

Spare Parts List Return Line Filter RFM with 4-hole attachment

Heating Cost Allocation Valve with local acquisition of the flow temperature

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

BR 01b Control valve

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Type 6213 EV, 6281 EV

Angle seat valve with piston actuator VZXA-...-K

Installation, Operation, and Maintenance Manual

Transcription:

GESTRA GESTRA Steam Systems NRG 16-12 NRG 17-12 NRG 19-12 Installation Instructions 818626-00 Level Electrode NRG 16-12, NRG 17-12, NRG 19-12

Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 ATEX (Atmosphère Explosible)...4 Explanatory Notes Scope of supply... 4-5 Description...5 Function...5 System components...5 Design...6 Technical Data NRG 16-12, NRG 17-12, NRG 19-12...6 Corrosion resistance...7 Sizing...7 Name plate / marking...7 Dimensions...8 Design NRG 1...-12...9 Key...11 Functional Elements NRG 1...-12...10 Key...11 Installation NRG 1...-12, step 1...12 NRG 1...-12, step 2...12 Attention...12 Important notes...13 Tools...13 Examples of installation...14 Key...15 2

Contents continued Wiring Page NRG 1...-12...15 Wiring diagram...16 Voltage table...17 Note...17 Tools...17 Commissioning Check wiring...17 Apply mains voltage...17 Operation High-level alarm...18 Note...18 Operational Malfunctions Fault-finding list for troubleshooting...18 Decommissioning Danger...19 Disposal...19 3

Important Notes Usage for the intended purpose Use level electrodes NRG 16-12, NRG 17-12 and NRG 19-12 only in conjunction with level switch NRS 1-8 for water-level limiting (high level alarm). Safety note The equipment must only be installed and commissioned by qualified and competent staff. Retrofitting and maintenance work must only be performed by qualified staff who through adequate training have achieved a recognised level of competence. Danger When loosening the electrode steam or hot water might escape. This presents the danger of severe scalds to the whole body. It is essential not to mount or dismantle the electrode unless the boiler pressure is verified to be 0 bar. The electrode becomes hot during operation. Touching the hot equipment presents the risk of severe burns to hands and arms. All installation and maintenance work must only be performed when the equipment is cold. ATEX (Atmosphère Explosible) The equipment constitutes a simple item of electrical equipment as defined in DIN EN 50020 section 5.4. According to the European Directive ATEX 94/9/EC the equipment may only be used in potentially explosive atmospheres if it is provided with approved Zener barriers. Applicable in Ex zones 1, 2 (1999/92/EC). The equipment does not bear an Ex marking. The suitability of the Zener barriers is certified in a separate document. Explanatory Notes Scope of supply NRG 16-12 1 Level electrode NRG 16-12, PN 40 1 Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright-annealed 1 Disk with set screw (measuring surface extension) optional 1 Retaining ring optional 1 Installation manual NRG 17-12 1 Level electrode NRG 17-12, PN 63 1 Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright-annealed 1 Disk with set screw (measuring surface extension) optional 1 Retaining ring optional 1 Installation manual 4

Explanatory Notes continued Scope of supply continued NRG 19-12 1 Level electrode NRG 19-12, PN 160 1 Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright-annealed 1 Disk with set screw (measuring surface extension) optional 1 Retaining ring optional 1 Installation manual Description The level electrode NRG 1...-12 detects the max. liquid level (high level alarm) in a steam boiler. The operation of the electrode is based on the conductivity measuring principle using the electrical conductivity of water for signaling one liquid level: High level alarm The NRG 1...-12 is designed for use in conjunction with level switch NRS 1-8 as a self-monitoring low level limiter with periodic self-checking (SMART) feature. Application in steam and pressurised hot-water plants in accordance with TRD 604, sheet 1 and sheet 2 (24 h/72 h operation) as well as EN 12952 and EN 12953. The electrical equipment meets the requirements of the Regulations on Protection Circuits DIN VDE 0116. Function The water level limiter comprises a level electrode type NRG 1...-12 and a level switch type NRS 1-8. The level electrode NRG 1...-12 consists of a pressure-tight measuring electrode. The electrode is insulated with a plastic sleeve. The high level limiter is based on the conductive measuring principle using the electrical conductivity of water for signaling water level. During normal, trouble-free operation the level electrode tip is not immersed in boiler water and no high level alarm is given. A high level alarm will only be raised if the electrode tip is submerged for more than 3 seconds. A high level alarm will also be activated if the insulating seals placed between the electrodes and the body are no longer pressure tight, allowing water to penetrate into the body. However in this instance the alarm is caused by a malfunction of the electrode, and confirmation should always be done by checking the water level in the gauge glass. The equipment combination NRG 1...-12 and NRS 1-8 provides fail safe protection against a first fault in accordance with TRD 604. System components NRS 1-8 Level switch NRS 1-8. Two channel level limiter (redundancy) with periodic self-checking routine to DIN VDE 0116. 5

Explanatory Notes continued Design NRS 1...-12 Screwed ¾" BSP, ISO 228-1, Fig. 3, Fig. 4, Fig. 5. Technical Data NRG 16-12, NRG 17-12, NRG 19-12 Type approval TÜV 01-02-0112 Service pressure NRG 16-12: 32 bar at 238 C NRG 17-12: 60 bar at 275 C NRG 19-12: 100 bar at 311 C Connection ¾" BSP, ISO 228-1 Materials Stem: 1.4571 X6CrNiMoTi17-12-2 Measuring electrode: 1.4401, X5CrNiMo17-12-2 Electrode insulation: PEEK Terminal box: Polyamide (PA) Lengths available 500 mm 1000 mm 1500 mm Cell constant C 0.13 cm -1 with measuring surface extension 0.3 cm -1 without measuring surface extension Response sensitivity 10 µs/cm at 25 C, cell constant 0.3 cm -1 0.5 µs/cm at 25 C, cell constant 0.13 cm -1 Terminal box Four-pin connector, cable gland M 16 (PG 9) Protection IP 65 to EN 60529 Max. admissible ambient temperature 70 C Weight Approx. 1.1 kg 6

Technical Data continued Corrosion resistance Provided that the equipment is used for its intended purpose, its safety is not impaired by corrosion. Sizing The body must not be subjected to sharp increases in pressure. Welds and flanges of the electrode are designed to withstand dynamic loading (bending and alternating stress). The dimensional allowances for corrosion reflect the latest state of technology. Name plate / marking Equipment designation Fig. 1 Fig. 2 7

Technical Data continued Dimensions 120 85 85 165 272 283 30 30 1500 8 1500 30 1500 Fig. 3 23 NRG 16-12 with measuring surface extension Fig. 4 NRG 17-12 without measuring surface extension Fig. 5 NRG 19-12 without measuring surface extension 8

Design NRG 1...-12 S A B I J C D H G E Fig. 6 F Fig. 7 33 ¾" BSP, ISO 228-1 N 8 N 10 0.5 Fig. 8 Fig. 9 9

Functional Elements NRG 1...-12 K L R M Q N O P Fig. 10 10

Key A Measuring electrode B Bore C Spring D Electrode tip E Disk (measuring surface extension) F Star-lock washer G Set screw H Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright-annealed I Seating surface J Electrode thread K Screw M4 L Lid M Upper part of terminal box N Connecting plate O Sealing element P Contact plate for level electrode Q Cable gland M 16 (PG 9) R Cable clamp S Thermal insulation, provided on site, d = 20 mm (outside of thermal insulation of steam generating unit) 11

Installation NRG 1...-12, step 1 1. Screw electrode tip D into measuring electrode A, Fig. 6 2. Carefully determine required measuring length, taking minimum length into account. 3. Mark length of electrode tip D. 4. Unscrew electrode tip D from measuring electrode A and cut tip. 5. Screw electrode tip D into measuring electrode A and tighten. Slide spring C along electrode tip D, so that its bent end completely enters into small bore B. 6. If a measuring surface extension is required slip disk E onto electrode tip D ensuring that the electrode tip protrudes 2 mm from the bottom of the disk. Fasten disk with set screw G. Push star-lock washer F over electrode tip against disk. NRG 1...-12, step 2 1. Check seating surfaces, Fig. 9 2. Place joint ring H onto seating surface I of electrode, Fig. 7 3. Apply a light smear of silicone grease (e. g. Molykote 111) to electrode thread J. 4. Screw level electrode into threads of flange provided on vessel and tighten with a 36 mm ring spanner. The torque required is 160 Nm when cold. Attention The seating surfaces and threads on the vessel and mounting flange must be accurately machined, Fig. 9 Use GESTRA PN 160 hat flange when applying the equipment in a high-pressure steam boiler. Do not bend the electrode tip when cutting. Use only the supplied ring joint 27 x 32, form D, DIN 7603, 1.4301, bright-annealed. Do not lag the electrode body. Do not insulate the threads with hemp or PTFE tape. Do not apply conductive paste or grease to the electrode thread. Provide a min. spacing of 14 mm between electrode and earth (flange, boiler wall), Fig. 11, Fig. 12, Fig. 13, Fig. 14 Observe the minimum distances for the installation of the electrode, Fig 14 Molykote 111 is a registered trademark of DOW Corning Corp., Midland Michigan, USA 12

Installation continued Important notes For the approval of the boiler standpipe the relevant regulations must be observed. For typical installation examples refer to page 14. When mounting the electrode laterally make sure that the inclination angle does not exceed 45 and that the length of the electrode rod is limited to 1000 mm. Fig. 12 If the electrode is installed outdoor, it must be provided with a weather-proof cover supplied by GESTRA. Tools Open-end spanner A. F. 13 Open-end spanner A. F. 36 Scriber Hacksaw Flat file, cut 2 13

Examples of Installation ¾" BSP DN 50 1 2 45 8 4 20 20 3 5 6 9 14 20 max. 1000 Fig. 11 90 20 0 Fig. 12 ¾" BSP 1 ¾" BSP ¾" BSP 1 2 DN 20 20 4 3 20 20 90 DN 100 24.5 24.5 4 3000 5 7 8 4 9! DN 20 Centre distance 5 9 20 Fig. 13 Fig. 14 DN 20 14

Key 1 Flange PN 40, PN 63, PN 160, DN 50, DIN 2501-1 Flange PN 40, PN 63, PN 160, DN 100, DIN 2501-1 2 For the approval of the boiler standpipe the relevant regulations must be considered. 3 Vent hole Provide bore as close as possible to the boiler wall! 4 High water HW 5 Electrode rod d = 8 mm 6 Protection tube DN 80 7 Protection tube DN 100 8 Electrode distance 14 mm 9 Low water LW 0 Reducer DIN 2616-2, K-88.9 x 3.2 42.4 x 2.6 W Wiring NRG 1...-12 Note that screened four-core cable, e. g. I-Y(St)Y 2 x 2 x 0.8 or LIYCY 4 x 0.5 mm² is required for wiring the electrode. Max. length 100 m with conductivites from 10 µs/cm. Max. length 30 m with conductivites from 0.5 µs/cm. Max. length 15 m with conductivites from 0.5 µs/cm and application of the ancillary unit URN 1 (24 V DC). 1. Unscrew screw K, Fig. 10 2. Take the terminal box off the level electrode, leaving the sealing element O on the contact plate P. 3. Remove lid L. 4. Press connecting plate N out of the upper part of the terminal box M. The upper part of the terminal box can be turned in steps of 90. 5. Detach cable gland Q and cable clamp R from the upper part of the terminal box M. 6. Run cable through cable gland Q and upper terminal box M and connect the terminals of the connecting plate N according to the wiring diagram. 7. Press connecting plate N into the upper part of the terminal box and align the cable. 8. Hold cable with cable clamp R and cable gland Q in position. 9. Mount lid L and insert screw K. 10. Put upper part of the terminal box onto the level electrode and fix it firmly with screw K. 15

Wiring continued Wiring diagram NRS 1-8 U 1-2 Fig. 15 NRS 1-8 U 1-2 Fig. 16 This wiring diagram is only valid for France. 16

Wiring continued Voltage table Use this voltage table as a reference when checking whether the level electrode is submerged or if there is a malfunction. Please take the wiring diagram of the electrode NRS 1-8 into account. Fig. 15, Fig. 16 U 1-2 U 1-2 10 µs/cm 0.5 µs/cm 2 V eff C=0.3 cm -1 10 V eff C=0.13 cm -1 Note The self-checking routine of the amplifier NRS 1-8 reduces U 1-2 every 40 seconds to 0 volt! Tools Screwdriver for cross-recess head screws, size 1 Screwdriver for slotted screws, size 2.5, completely insulated according to DIN VDE 0680-1 Open-end spanner A. F. 18 (19) Commissioning Check wiring Check whether the NRG 1-12 and the associated controller NRS 1-8 are wired in accordance with the wiring diagram. Fig. 15, Fig. 16 Apply mains voltage Apply mains voltage to level switch NRS 1-8. 17

Operation High-level alarm Operation in combination with controller NRS 1-8 in steam and pressurised hot water plants to TRD 401, TRD 602, TRD 604, EN 12952, EN 12953 or other national regulations. Note Should malfunctions occur during the commissioning procedure refer to chapter Operational Malfunctions on page 18 in order to analyse and correct them. Operational Malfunctions Fault-finding list for troubleshooting Level electrode exposed high-level alarm Fault: Mains voltage is not applied to level switch. Remedy: Apply mains voltage. Wire electrode according to wiring diagram. Fault: Remedy: Fault: Remedy: The electrode rods have earth contact. Check and change position of installation. The internal insulation of the electrode rod is damaged. Replace level electrode. High level reached no function Fault: The electrode housing does not have earth connection to the boiler. Remedy: Clean seating surfaces and insert metal joint ring (of stainless steel 1.4301) 27 x 32, form D, DIN 7603, bright-annealed. Do not insulate level electrode with hemp of PTFE tape. Fault: Remedy: Fault: Remedy: The vent hole in the protection tube does not exist, is obstructed or flooded. Check protection tube and, if necessary, provide vent hole. The isolating valves of the external measuring pot (optional extra) are closed. Open isolating valves. If faults occur that are not listed above or cannot be corrected, please contact our Technical Service or authorized agency in your country. 18

Decommissioning Danger Risk of severe burns and scalds to the whole body! Before removing the level electrode make sure that the vessel or measuring pot are depressurised (0 bar) and cooled down to room temperature (20 C). Disposal Remove the level electrode and separate the waste materials in accordance with the material specification. Electronic components (boards) must be disposed of separately. For the disposal of the level electrode observe the pertinent legal regulations concerning waste disposal. 19

GESTRA Agencies all over the world: www.gestra.de España GESTRA ESPAÑOLA S.A. Luis Cabrera, 86-88 E-28002 Madrid Tel. 00 34 91 / 5 15 20 32 Fax 00 34 91 / 4 13 67 47; 5 15 20 36 E-mail: aromero@flowserve.com Polska GESTRA Polonia Spolka z.o.o. Ul. Schuberta 104 PL - 80-172 Gdansk Tel. 00 48 58 / 3 06 10-02 od 10 Fax 00 48 58 / 3 06 33 00 E-mail: gestra@gestra.pl Great Britain Flowserve Flow Control (UK) Ltd. Burrel Road, Haywards Heath West Sussex RH 16 1TL Tel. 00 44 14 44 / 31 44 00 Fax 00 44 14 44 / 31 45 57 E-mail: gestraukinfo@flowserve.com Portugal Flowserve Portuguesa, Lda. Av. Dr. Antunes Guimarães, 1159 Porto 4100-082 Tel. 0 03 51 22 / 6 19 87 70 Fax 0 03 51 22 / 6 10 75 75 E-mail: jtavares@flowserve.com Italia Flowserve S.p.A. Flow Control Division Via Prealpi, 30 l-20032 Cormano (MI) Tel. 00 39 02 / 66 32 51 Fax 00 39 02 / 66 32 55 60 E-mail: infoitaly@flowserve.com USA Flowserve GESTRA U.S. 2341 Ampere Drive Louisville, KY 40299 Tel.: 00 15 02 / 4 95 01 54, 4 95 17 88 Fax: 00 15 02 / 4 95 16 08 E-mail: dgoodwin@flowserve.com GESTRA AG P. O. Box 10 54 60, D-28054 Bremen Münchener Str. 77, D-28215 Bremen Tel. +49 (0) 421 35 03-0 Fax +49 (0) 421 35 03-393 E-Mail gestra.ag@flowserve.com Internet www.gestra.de 818626-00/306cm 2003 GESTRA AG Bremen Printed in Germany 20