CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

Similar documents
Type IMC Indoor current transformer

Instrument Transformer Reference. Meter and Relay Applications for the Electrical Industry

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Volt Instrument Transformers

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

REFERENCE GUIDE INSTRUMENT TRANSFORMERS INDOOR / OUTDOOR CAST RESIN CONSTRUCTION

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Indoor Linear 50W Driver SI-CU WW

B BASIC HEAT TREATMENT CONSOLE

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

TMC 91H is now TMC 60 C Series

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

Kuhlman Electric Corporation Volt Instrument Transformers

Safety Limit Switch

Kuhlman Electric Corporation Volt Instrument Transformers

A 1.2 kv class externally removable secondary bushing

Manual Reset Limit Switch

3 Phase Power Systems - Designed for Canada

Power Conversion. Battery Chargers. Model

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Kuhlman Electric Corporation. Engineered Designs Instrument Transformers

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Technical information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Product Information Packet L5020 5HP,1725RPM,1PH,60HZ,215,3744LC,XPFC,F1

ches UL File No. E101598

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

Power Distribution Blocks

Wide-Vue Analog Panel Meters

Chapter 06 Accessories ACCESSORIES

Safety switches for hinges

Installation and Construction Notes for EVSE4

Current transformers. Current transformers

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Table of Contents. HCC Contactor Nomenclature

4-Way Mixing Panel Submittal - Page 1 of 6

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

BETA Switching Switches and Light Indicators

Medium Voltage Metal-Enclosed Switches

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

Non-illuminated Push Buttons

Model 10 Electromechanical Totalizer

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

KD45 ±20N. Description

XMC0 Series. Definite Purpose Contactors

Chapter 6 Generator-Voltage System

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

ACCUSTATION SUBMITTAL MATERIALS

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Hinged Safety Door Switch

Switch rated plugs and receptacles with nema 4X protection

Control Transformers

MF4E MF4E

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

General Purpose Buck - Boost Wiring Diagrams... 86

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

HPS EnduraCoil. Cast Resin Transformer

VA9208-xxx-xx Series Electric Spring Return Actuators

Micro Contactor MA Series

30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R

Century Style Analog Panel Meters

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Engineering Excellence Through Expertise

SERIES POWER DISTRIBUTION BLOCKS

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

MODEL 422 Submersible Pump Controller

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

AV-8020 Series Floating Control Actuated Valve

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Magnetic Overcurrent Circuit Breaker

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Product Information Packet PCL1327M 5HP,3450RPM,1PH,60HZ,56HCY,3535LC,ODTF

NFPA 70E 68! & CSA Z462

XMC0 Series DEFINITE PURPOSE CONTACTORS

Single & Three-Phase Soft Starters

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

Current accuracy class. Sensor principles

VA9208-xxx-xx Series Electric Spring-Return Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Transcription:

MODEL N 4." I.D. PAGE No 1-30 TERMINAL OPTION LEAD WIRE OPTION 6.75 SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.75 1.36 1.16 5.75 7.00 0. x 0.50 SLOT (2 PLACES) UL 1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 8-32 BRASS STUD (2 PLACES) Ø0.39 (4 PLACES) POLARITY LABEL (H1) 4. 7.13 OPTIONAL P7 MOUNTING PLATE 5.44 6.75 3.75 OPTIONAL B1 BRACKET SCREW CLAMP FOR SS BAND 5.44 6.75 NOTES 1). ALL DIMENSIONS IN INCHES 2). ALL DIMENSIONS REF ONLY Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for ratios up to, 1.15 @ 30C for ratios of and above Insulation voltage class is 0.6KV BIL 10KV For indoor applications only Reference documents IEEE C57.13, UL1244, and IEC 44-1 Enclosure is glass-filled nylon, color is black Optional bracket is aluminum Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575 2.0, 5.0, and 10 VAC output at F.S. primary amperage. Other non - standard ratings also available. 1, 0.2, and 0.1 A output at F.S. primary amperage. Other nonstandard ratings also available 8-32 Brass Stud Terminals or #16 AWG UL 1015 Lead Wires Custom lead wire lengths and types Thermal ratings above 1.33 for selected ratios. Center tap and custom multi tap winding arrangements

4." I.D. PAGE No 1-31 MODEL N TYPICAL EXCITATION CURVE for MODEL N at 60HZ 00:5A 1 750:5A 10-4 NUMBER * N-500-00-xxx N-750-00-xxx N-1000-00-xxx N-1600-00-xxx N-2000-00-xxx N-00-00-xxx N-3000-00-xxx RATIO 750:5A 1 00:5A ACCURACY @ 60HZ, pf = 0.95 ± % BURDEN (VA) 3.0 7.5 15 40 40 50 NOMINAL WINDING RESISTANCE (ohm) 0.14 0.21 0.28 0.41 0.52 0.81 * "xxx" describes termination: "T" FOR BRASS STUDS, "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

MODEL ND 4." I.D. PAGE No 1-32 SIDE TERMINAL OPTION LEAD WIRE OPTION 5.75 1.19 2.88 3.81 4.88 6.00 5.00 3.50 OPTIONAL B20 MOUNTING BRACKET KIT 8-32 BRASS STUD (2 PLACES) UL 1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 4. 5.00 6.00 0.26 x 0.63 THROUGH SLOT (4 PLACES) POLARITY LABEL (2 PLACES) POLARITY LABEL 1. 0.88 TOP TERMINAL OPTION NOTES 1). ALL DIMENSIONS IN INCHES 2). ALL DIMENSIONS REF ONLY Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for ratios up to 40:5A, 1.15 @ 30C for ratios of 40:5A and above Insulation voltage class is 0.6KV BIL 10KV For indoor applications only Reference documents IEEE C57.13, UL1244, and IEC 44-1 Enclosure is made of glass-filled Nylon, color is black Optional bracket is steel Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575 2.0, 5.0, and 10 VAC output at F.S. primary current. Other non - standard ratings also available 1, 0.2, and 0.1 A output at F.S. primary current. Other non-standard ratings also available 8-32 Brass Stud Terminals or #16 AWG UL 1015 Lead Wires. Choice of stud location Custom lead wire lengths and types Thermal ratings above 1.33 for selected ratios Available with B20 bracket kit. See Bracket Data Section for dimensions Center tap and custom multi tap winding arrangements

4." I.D. PAGE No 1-33 MODEL ND TYPICAL EXCITATION CURVE for MODEL ND at 60HZ 5000:5A 1 2000:5 1200:5 10-4 NUMBER * ND-300-00-xxx ND-500-00-xxx ND-600-00-xxx ND-800-00-xxx ND-1000-00-xxx ND-1200-00-xxx ND-1500-00-xxx ND-1600-00-xxx ND-2000-00-xxx ND-00-00-xxx ND-3000-00-xxx ND-4000-00-xxx ND-5000-00-xxx RATIO 1200:5A 1 1 00:5A 5000:5A ACCURACY @ 60HZ ± % BURDEN (VA) 1.5 2.0 2.5 4.0 8.5 15 20 30 20 30 NOMINAL WINDING RESISTANCE (ohm) 0.07 0.11 0.14 0.18 0.22 0.27 0.33 0.36 0.41 0.52 0.54 0.76 1.2 * "xxx" describes termination: "T" FOR BRASS STUDS, "TT" FOR BRASS STUDS in top terminal configuration, and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

MODEL NDX 4." I.D. PAGE No 1-34 SIDE TERMINAL OPTION LEAD WIRE OPTION 5.75 1.19 2.88 3.81 4.88 6.00 5.00 3.50 OPTIONAL B20 MOUNTING BRACKET KIT 8-32 BRASS STUD (2 PLACES) UL 1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 4. 5.00 6.00 0.26 x 0.63 THROUGH SLOT (4 PLACES) POLARITY LABEL (2 PLACES) POLARITY LABEL 1. 0.88 TOP TERMINAL OPTION NOTES 1). ALL DIMENSIONS IN INCHES 2). ALL DIMENSIONS REF ONLY Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for ratios up to 40:5A, 1.15 @ 30C for ratios of 40:5A and above Insulation voltage class is 0.6KV BIL 10KV For indoor applications only Reference documents IEEE C57.13, UL1244, and IEC 44-1 Enclosure is made of glass-filled Nylon, color is black Optional bracket is steel Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575 2.0, 5.0, and 10 VAC output at F.S. primary current. Other non - standard ratings also available 1, 0.2, and 0.1 A output at F.S. primary current. Other non-standard ratings also available 8-32 Brass Stud Terminals or #16 AWG UL 1015 Lead Wires. Choice of stud location Custom lead wire lengths and types Thermal ratings above 1.33 for selected ratios Available with B20 bracket kit. See Bracket Data Section for dimensions Center tap and custom multi tap winding arrangements

4." I.D. PAGE No 1-35 MODEL NDX TYPICAL EXCITATION CURVE for MODEL NDX at 60HZ 1200:5A 400:5A 200:5A 0:5A 10-4 NUMBER * NDX-300-00-xxx NDX-500-00-xxx NDX-600-00-xxx NDX-800-00-xxx NDX-1000-00-xxx NDX-1200-00-xxx NDX-1500-00-xxx NDX-1600-00-xxx NDX-2000-00-xxx NDX-00-00-xxx NDX-3000-00-xxx NDX-4000-00-xxx RATIO 1200:5A 1 1 00:5A ACCURACY @ 60HZ ± % BURDEN (VA) 6.0 20 50 75 100 80 80 100 65 65 75 NOMINAL WINDING RESISTANCE (ohm) 0.05 0.08 0.12 0.16 0.22 0.31 0.33 0.36 0.44 0.48 0.53 0.76 * "xxx" describes termination: "T" FOR BRASS STUDS, "TT" FOR BRASS STUDS in top terminal configuration, and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

W.I.C.C. Ltd 119 MULLER RD PO Box 2 WASHINGTON IL 61571 (309)-444-41 FAX (309)-444-3313 MODEL NDX 4." I.D. PAGE No 1-36 TYPICAL EXCITATION CURVE for WICC MODEL NDX at 60HZ 1 10-4 TYPICAL EXCITATION CURVE for WICC MODEL NDX at 60HZ 00:5A 10-4