! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

Similar documents
! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

CAUTION All safety information must be followed as provided in Service Manual

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Cooking Products Fault Code Reference Guide

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SLIDE-IN ELECTRIC RANGE

AS-1535 SH User Guide

Section 7 - Troubleshooting Guide

POLARSTART PS-3025 SH Multi-Channel Remote Starter System for AUTOMATIC Transmissions

ELECTRIC RANGES

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

INSTALLATION GUIDE Table of Contents

PARTS & SERVICE MANUAL

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Flight Systems. Replacement for KASSEC DESCRIPTION

Subject Underhood G System Error Codes and Symptoms System or Parts affected

CONTROLLER DIAGNOSTIC GUIDE

SERVICE NOTEBOOK VCWB300 PROFESSONAL MODEL BUILT-IN FULL HEIGHT WINE COOLER UPDATED

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

Amana Technical Information Manual Clean Gas Range

UPPER OVEN PARTS For Models:JJW2730WB01, JJW2730WS01 (Black) (Stainless)

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

UPPER OVEN PARTS For Models: JJW2830WB00, JJW2830WW00, JJW2830WS00, JJW2830WR00 (Black) (White) (Stainless) (Oiled Bronze)

VEHICLE THEFT/SECURITY SYSTEMS

6900-( )-( ) HIGH SPEED SANDWICH PRESS

SERVICE MANUAL IMPINGER COUNTERTOP OVEN MODEL 1300 SERIES

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

Service Training Manual

Owner s Guide CARS & CA4B5

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

Modulating Furnace Information. Warning on Meter Setting - Read First!

12V PROGRAMMABLE POWER OUT

INSTALL GUIDE IDL-IDS(RS)-BZ2B-[ADS-BZ2]-EN

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Section 55 Chapter 6

Owner s Guide CARS & CA2LCD5

Centrifuge Operator / Service Manual

E Series CE Approved Intermittent Pilot Ignition Control

Order Number MOP C2. Microwave Oven

5. Alignment and Adjustments

SUPPLEMENTAL RESTRAINT SYSTEM(SRS)

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

INSTALLATION GUIDE. FCC ID NOTICE

SMT-150 Installer Manual

INSTALL GUIDE IDL-IDS(RS)-BM1-[ADS-BM1]-EN

User Guide 1 WAY FM MANUAL TRANSMISSION REMOTE STARTER. Table of Contents. Introduction

B-RAD Select USER MANUAL TABLE OF CONTENTS

SST-3 Start-Stop-Throttle

A419ABG-3C Electronic Temperature Control

SECTION Interior Lighting

Deep Sea Electronics Plc

INSTALL GUIDE FLCI-IDS(RS)-BZ4-[FLRSBZ4]-EN

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

GCU-10. Automatic Engine Control Unit Operators Manual

FMV156DBF FMV156DCG FMV156DQF FMV156DSF

install guide COM-IDS(RS)-BM1-[ADS-BM1]-EN

IFD AIR CLEANER SERVICE MANUAL

C-PIM701 (Police Interface Module) 2018 Dodge Charger Pursuit

INSTALL GUIDE AKX-IDS(RS)-BZ1B-[ADS-BZ1]-EN


KEYLESS ENTRY SYSTEM & TIRE PRESSURE MONITOR ACCESSORIES & EQUIPMENT General Motors Corp. - Remote Keyless Entry System

USERS MANUAL MCD REMOTE OPERATOR

ELECTROLUX SERVICE MANUAL

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

5 FEATURES DDEC FOR MBE900 AND MBE4000

Remote Engine Starter

Model 8000XL OPERATOR MANUAL

REMOTE ENGINE STARTER

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

2001 Dodge Durango ACCESSORIES & EQUIPMENT' 'Anti-Theft Systems - Dakota & Durango 2001 ACCESSORIES & EQUIPMENT

INSTALL GUIDE DIR-IDS(RS)-BM1-[FLRSBM1]-EN

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

REMOTE ENGINE STARTER

INSTALL GUIDE COM-HA(RS)-HA6P-[FT-HA6-DC]-EN

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

Alarms & Remote Start

Amana Domestic Washer Technical Information 120 V, 60 Hz Models ALW895SAC PALW895SAC ALW895SAW PALW895SAW

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

ca 5550SST Owner s Guide

FM SECURITY AND REMOTE START SYSTEM

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

GLMV169DBF PLMV169DCG

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

2001 Chevrolet Corvette ACCESSORIES & EQUIPMENT Remote Keyless Entry Systems - Corvette

INSTALL GUIDE AKX-IDS(RS)-BM1-[ADS-BM1]-EN

Transcription:

Electric Freestanding Range Technical Information MER5875RA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual 16025644 for detailed installation, operating, testing, troubleshooting, and disassembly instructions.! CAUTION All safety information must be followed as provided in Service Manual 16025644. To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Model MER5875RA* Power Source @ 240 V (208 V) Electrical rating 11.6 (8.7) Amperage 40 Amp Frequency 60 Hz Element Wattage @ 240 V (208 V*) Ribbon element, left rear 1,200 Ribbon element, right rear 1,200 Ribbon element, left front, double 1,200/1,200 Ribbon element, right front, triple 2,200/1,100/900 Ribbon element, center rear, warming 100 Oven Wattage @ 240 V (208 V) Bake 6 pass 3,600 (2,900) Broil 6 pass 3,600 (2,900) Convection 1,850 (1,500) Oven Interior Dimensions in. (cm) Height 19 (48.26) Width 24 1/4 (61.6) Depth 19 1/2 (49.53) Product Exterior Dimensions in. (cm) Height overall 47 3/8 (120.33) Width 29 7/8 (75.88) Depth (including door) 26 5/8 (67.75) Depth oven door closed with handle 28 1/2 (72.39) Height to cooking surface 36 (91.4) Unit Features 5.3 cubic foot Interior oven light Sabbath mode Child lockout 12 hour automatic shut off Clock and Timer Hidden bake element Triple element Dual element Convection Weight lbs. (kg) Crated 209 (94.80) Uncrated 224 (101.60) *Rating of 208 VAC is approximately 80% of 240 VAC value. June 2006 1 16027229 2006 Maytag Services Replaces 16026900

Component Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless Illustration Component Test Procedure Results Oven light socket (A-15 bulb shape) Measure voltage at oven light... Remove one wire from receptacle and test resistance of terminals... 120 VAC, see wiring diagram for terminal identification. with bulb inserted. If voltage is not present at oven light, check wiring or light switches. Indicator lights Measure voltage at indicator light... If voltage is present and light does not work, replace light. If voltage is not present at indicator light, check wiring. Rocker switch Measure continuity of switch positions: Open... Closed... Infinite.. C COM NO NC NO NC Door lock switch (part of autolatch assembly) Door plunger switch (door position switch) Autolatch assembly with switch Switch connection in the following positions: Door latch locked... Door latch unlocked... Switch connection in following positions: Door open... Door closed... Disconnect wires and test for continuity per wiring diagram... COM-NO=Infinity, COM-NC=. COM-NO=, COM-NC=Infinity. COM-NO=Infinity. COM-NO=. See wiring diagram for schematic layout. Door latch assembly Disconnect wires and test for continuity per wiring diagram... See wiring diagram for schematic layout. Refer to Parts Manual for correct autolatch switch associated with the correct manufacturing number. Broil element Disconnect wire leads to element and measure resistance of terminals... Approximately 15.5 Ω. Bake element Convection element Convection motor Limiter Measure voltage at element... Disconnect wire leads to element and measure resistance of terminals... Measure voltage at element... Disconnect wire leads to element and measure resistance of terminals... Measure voltage at terminals... Verify supply voltage... Disconnect wire leads to motor and measure resistance between terminals (verify terminals are not shorted to chassis)... Normally Closed Verify proper operation. Open... 320 F... Closed... Manual reset... 240 VAC. See wiring diagram for terminal identification. If voltage is not present at element, check wiring. Approximately 18.5 Ω. 240 VAC. See wiring diagram for terminal identification. If voltage is not present at element, check wiring. Approximately 30 Ω - cold. 240 VAC. See wiring diagram for terminal identification. If voltage is not present at element, check wiring. 120 VAC. Approximately 400 Ω. Infinite.. 16027229 2 June 2006 Replaces 16026900 2006 Maytag Services

Component Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless Illustration Component Test Procedure Results Infinite switch Remove wiring from H1 and H2. Connect 5 L1 3 volt/ohms meter to H1 and H2. Approximate L2 Measure the following for voltages at LO, Time On Time Off 4 H2 MED, HI:... 4 H2 5 L2 1 H1 1 H1 P L1 P 2 3 2 Infinite switch Infinite switch, low heat Infinite switch, dual element Voltage between H1 and H2... Remove wiring from 2 and 4. Connect volt/ohms meter to 2 and 4. Measure the following for voltages at LO, MED, HI:... Voltage between 2 and 4... Remove wiring from H1 and H2. Connect volt/ohms meter to H1 and H2. Measure the following for voltages at LO, MED, HI:... Voltage between H1 and H2... Remove wiring from H1 and H2. Connect volt/ohms meter to H1 and H2. Measure the following for voltages at LO, MED, HI:... LO 5% 95% MED (4-5) 35% 65% HI 100% 0% 240 VAC. If not, replace switch. Approximate Time On Time Off LO 5% 95% MED (4-5) 35% 65% HI 100% 0% 240 VAC. If not, replace switch. Approximate Time On Time Off SIMMER 5% 95% MED (5) 55% 45% HI 100% 0% 240 VAC. If not, replace switch. Approximate Time On Time Off LO 8% 92% MED (4-5) 35% 65% HI 100% 0% Ribbon element, 1200 W Voltage between H1 and H2... Disconnect wiring to element and measure cold resistance of terminals... 240 VAC. If not, replace switch. Approx. 44.3 to 48.9 Ω. Measure voltage at element... 240 VAC. If voltage is not present, check wiring. Ribbon element, triple, 3000 W (900 W Inner, 1100 W Middle, 2200 W Outer) Disconnect wiring to element and measure cold resistance of terminals... 2200W (Inner):... Approx. 24 to 28 Ω. 1100W (Middle):.. Approx. 49 to 55 Ω. 900W (Outer):... Approx. 60 to 68 Ω. Measure voltage at element... 240 VAC. If voltage is not present, check wiring. Ribbon element, dual, 2400 W (1200 W Inner, 1200 W Outer) Disconnect wiring to element and measure cold resistance of terminals... 1200W (Inner):... Approx. 44 to 49 Ω. 1200W (Outer):... Approx. 44 to 49 Ω. Measure voltage at element... 240 VAC. If voltage is not present, check wiring. (Series 11) Ribbon element, warming, 100 W Disconnect wiring to element and measure cold resistance of terminals... Measure voltage at element... Approx. 133 to 147 Ω. 240 VAC. If voltage is not present, check wiring. June 2006 3 16027229 2006 Maytag Services Replaces 16026900

Component & Control Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless Illustration Component Test Procedure Results (Series 12) Ribbon element, Disconnect wiring to element and measure warming, 100 W cold resistance of terminals... Approx. 141 to 155 Ω. Measure voltage at element... 240 VAC. If voltage is not present, check wiring. Temperature sensor Disconnect wire leads to sensor and measure resistance... Approximately 1080 Ω at room temperature 80 F. Control Feature Procedure Results H1 Oven temperature adjustment Press BAKE pad. Enter 550 on the digit pad. Immediately press and hold BAKE pad for 3 to 5 seconds. Oven can be adjusted from -35 to +35 degrees in 5-degree increments by pressing AUTOSET pads. To avoid over adjusting the oven, move temperature 5 degrees each time. Wait 4 seconds for the data entry timer to expire to accept the change. Temperature adjustment will be retained even through a power failure. H1 Temperature display Press and hold CANCEL and BAKE pads for 3 to 5 seconds. H1 Clock display Press and hold CANCEL and CLOCK pads for 3 to 5 seconds. H1 24-hour clock Press and hold CANCEL and FAVORITE pads for 3 to 5 seconds. H1 Factory default Press and hold CANCEL and KEEP WARM pads for 3 to 5 seconds. H1 12-hour shutoff Control cancels cooking operations and disables relay drives 12 hours after last pad touch. H1 Sabbath mode Hold CLOCK pad for 3 to 5 seconds to activate Sabbath mode. Hold CLOCK pad for 3 to 5 seconds to disable Sabbath mode. Desired bake function must be initiated before entering Sabbath mode. H1 Child lockout Press and hold CANCEL and COOK & HOLD pads for 3 to 5 seconds. "OFF" displays in temperature display area. "LOCK" flashes while door is locking. To reactivate control, press and hold CANCEL and COOK & HOLD pads for 3 to 5 seconds. H1 Diagnostic code display Press and hold AUTOSET pad when applying power to the range. Cycle through the codes using the number pads 1 through 5. Increasing or decreasing oven temperature does not affect selfcleaning temperature. Allows user to change temperature display between F or C. Allows user to turn clock display on or off. Allows user to toggle clock display between 12-hour or 24-hour format. Allows user to reset clock to factory settings. See Sabbath mode to disable. "SAb" flashes for 5 seconds, then remains on until timed-out or canceled. (Status SAb is not fault code 5A6.) All pad inputs are disabled except CANCEL and CLOCK. 12-hour shutoff is disabled, allowing bake mode operation for 72 hours. The oven light is not disabled. This safety feature prevents children from accidentally programming the oven. The electronic oven control is disabled. Child lockout features must be reset after a power failure. The last 5 diagnostic codes will be stored in the non-volatile memory. See "Description of Error Codes" for explanation. 16027229 4 June 2006 Replaces 16026900 2006 Maytag Services

Control Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless Feature Procedure Results H1 Control Panel Assembly Matrix is indicated as follows: 1000 6600 Ω for Cancel pad. 1000 15000 Ω for All other pads. Bake Broil Keep Warm Clean Convect Roast Cook & Hold Convect Bake Favorite Timer Clock Oven Light CANCEL Delay Autoset 16 9 8 1 Pad 1 2 3 4 5 6 7 8 9 0 Cancel Clock Cook & Hold Broil Bake Convect Bake Convect Roast Clean Keep Warm Favorites Timer Light Trace 13 & 15 12 & 13 12 & 15 4 & 14 4 & 12 4 & 10 5 & 13 5 & 12 5 & 10 10 & 12 1 & 2 or 1 & 3 4 & 5 4 & 7 5 & 7 10 & 11 4 & 13 7 & 14 7 & 15 11 & 12 13 & 14 5 & 14 7 & 13 Measurement H1 Control: Relay Logic COOKING MODE IDLE r r r r BAKE PREHEAT r r r BAKE r r r BROIL PREHEAT r r r BROIL r r r CLEAN PREHEAT r r r CLEAN r r r r KEEP WARM r r r CONVECT BAKE PREHEAT r CONVECT BAKE r BAKE BROIL CONVECT ELEMENT CONVECT FAN OVEN LIGHT KEY INDEX - OFF - ON - ON OR OFF (DETERMINED BY USER INPUT) - TEMPERATURE CONTROLLED June 2006 5 16027229 2006 Maytag Services Replaces 16026900

Control Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless "Quick Test" Mode for H1 Electronic Range Control (ERC) Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the control will exit the quick test mode. NOTE: NOTE: NOTE: 1. Press and hold CANCEL and BROIL pads for 3 to 5 seconds. 2. Once the control has entered the "Quick Test" mode, release both pads. 3. Press each of the following pads indicated in the table below. Press the pad once to activate the response. Press the pad a second time to deactivate the response. This mode must be entered within the first 5 minutes after power up. If the temperature sensor is greater than 400 F or if the temperature sensor reaches 400 F while under test, the Quick Test mode will be disabled. H1 Control: Display Pad Response BAKE... Bake relay activated BROIL... Broil relay activated KEEP WARM... Bake DLB and Broil DLB activated CLEAN... MDL relay activated COOK & HOLD... Displays last diagnostic code FAVORITE... Displays EEPROM version number TIMER... Displays main code version number CLOCK... All display segments illuminated OVEN LIGHT... Oven light activated CANCEL... Exit Quick Test mode 1... Even segments on 2... Odd segments on 3... N\A 4... Bake relay activated 5... Broil relay activated 6... Convection relay activated 7, 8, 9... N/A AUTOSET... Steps through last 5 diagnostic codes H1 Control: Description of Error Codes Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode. Each error code is four digits long and is created based on the following table. Digit Description 1 st Primary System: 1 Local to the control circuit board 3 Sensor or meat probe 4 Control input 9 Door lock 2 nd Measurable: d Diagnostic: measurable parameter c Control related, replace control 3 rd Secondary System: Sequential numbering 4 th Oven Cavity: 1 Upper oven (or single cavity oven) 2 Lower oven c Control specific Diagnostic Code Display Mode can be activated by pressing and holding the AUTOSET pad for 3 to 5 seconds at power-up. Diagnostic Code Display Mode can only be started while powering up the control. 16027229 6 June 2006 Replaces 16026900 2006 Maytag Services

Control Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless H1 Control: Diagnostic Code Checking Code Description When Checked Detection 1c1c Shorted key Always 1 minute 1c2c Keyboard tail disconnected Always 1 minute 1c31 Cancel key circuit problem Always 20 seconds 1c32 Cancel key circuit problem Always 20 seconds 1c6c EEPROM error When accessing EEPROM 3 tries 1c7c Control not calibrated Always 3 tries 1c8c Cooking program error Cook or clean programmed 3 tries 1d11 Runaway temp (650 F), door unlocked Latch unlocked 1 minute 1d12 Runaway temp (650 F), door unlocked Latch unlocked 1 minute 1d21 Runaway temp (950 F), door locked Latch locked 1 minute 1d22 Runaway temp (950 F), door locked Latch locked 1 minute 3d11 Sensor open Cook or clean active 20 seconds 3d12 Sensor open Cook or clean active 20 seconds 3d21 Sensor shorted Cook or clean active 20 seconds 3d22 Sensor shorted Cook or clean active 20 seconds 4d11 Door switch position failure Clean or keyboard Lockout active 1 minute 4d12 Door switch position failure Clean or keyboard Lockout active 1 minute 4d21 No reverse airflow fan rotation (no/low RPM) Clean or Cook programmed 1 minute 4d31 Reverse airflow fan state (on when should be off) Should be OFF 1 minute 4d51 Door switch circuit failure Convect, Clean or Keyboard Lockout programmed 1 minute 4d52 Door switch circuit failure Convect, Clean or Keyboard Lockout programmed 1 minute 9d11 Latch will not lock Latch should be locked See Note 6 9d12 Latch will not lock Latch should be locked See Note 6 9d21 Latch will not unlock Latch should be unlocked See Note 6 9d22 Latch will not unlock Latch should be unlocked See Note 6 9d31 Latch state unknown, both locked and unlocked Latch should be locked or when lock attempted See Note 6 9d32 Latch state unknown, both locked and unlocked Latch should be locked or when lock attempted See Note 6 H1 Control: Diagnostic Code Handling Code Measurable What is Displayed Action Taken By Control Disables audible for affected key depression 1c1c Keypress Nothing Disables all outputs 1, 2 Disables lights and timers 1c2c Keyboard loop improper value Nothing Disables audible for key depression Disables all outputs 1 Disables lights and timers 1c31 Cancel key improper value BAKE flashes 3 Disables all outputs for cavity 1 1c32 Cancel key improper value BAKE flashes 3 Disables all outputs for cavity 1 1c6c No response from EEPROM Nothing Disables all outputs 1 1c7c Calibration value out of range "CAL" in time digits Completely disables oven 4 1c8c CRC invalid Nothing Cancels active cook functions 1d11 Sensor resistance > 2237 Ohms BAKE flashes 3 Disables all cook functions for cavity 1d12 Sensor resistance > 2237 Ohms BAKE flashes 3 Disables all cook functions for cavity 1d21 Sensor resistance > 2787 Ohms BAKE flashes 3 Disables all cook functions for cavity 1d22 Sensor resistance > 2787 Ohms BAKE flashes 3 Disables all cook functions for cavity 3d11 Sensor resistance > Infinite Ohms BAKE flashes 3 Disables all cook functions for cavity 3d12 Sensor resistance > Infinite Ohms BAKE flashes 3 Disables all cook functions for cavity 3d21 Sensor resistance > 0 Ohms BAKE flashes 3 Disables all cook functions for cavity 3d22 Sensor resistance > 0 Ohms BAKE flashes 3 Disables all cook functions for cavity 4d11 Door switch not closed when door is locked Nothing Disables Clean and Lockout functions 5 4d12 Door switch not closed when door is locked Nothing Disables Clean and Lockout functions 5 4d21 No reverse airflow fan rotation (no/low RPM) Nothing Disables all cook functions for cavity 4d31 Reverse airflow fan state (on when should be off) Nothing No action 4d51 Door switch not open or closed Nothing Disables Convect, Clean, and Lockout functions 4, 5 4d52 Door switch not open or closed Nothing Turn off light and disable light from door switch Disables Convect, Clean, and Lockout functions 4, 5 Turn off light and disable light from door switch SaB (5a6) Sabbath Mode active SaB Disables all functions until Sabbath Mode deactivated 9d11 Lock switch not closed LOCK flashes 3 Disables Clean and Lockout functions 4 9d12 Lock switch not closed LOCK flashes 3 Disables Clean and Lockout functions 4 9d21 Unlock switch not closed LOCK flashes 3 Disables Clean and Lockout functions 4 9d22 Unlock switch not closed LOCK flashes 3 Disables Clean and Lockout functions 4 9d31 Latch both locked and unlocked LOCK flashes 3 Disables Clean and Lockout functions 4 9d32 Latch both locked and unlocked LOCK flashes 3 Disables Clean and Lockout functions 4 June 2006 7 16027229 2006 Maytag Services Replaces 16026900

Control Testing Procedures To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless H1 Control: Notes 1 2 3 4 5 6 "Action Taken" applies as long as the condition exists. If the condition clears, the control recovers. If there is a cook function or timer active, the function continues. The user cannot edit the function, and [Cancel] will cancel the cook mode. Flash rate: 0.2 seconds on, 0.1 second off. Pressing any key will clear the display until the fault clears and is re-triggered. "Action Taken" applies until there is a POR (Power On Reset ["hard reset"]). If the control believes the door is locked, it will attempt to unlock it when the function cancels and the cavity temperature cools. Special conditions for latch faults (9dxx): A known good unlock position is defined as when the unlock switch reads closed and lock switch reads open. A known good lock position is defined as when the unlock switch reads open and lock switch reads closed. A faulted switch means the switch input is reading an invalid state, neither open nor closed. Once a latch fault occurs, latch movement is disabled until there is a POR. An error tone will sound if a function requiring a faulted latch is attempted. If at POR, the latch is not at a known good unlock position: If the latch is at a good lock position, it will attempt to unlock when the RTD (Resistance Temperature Device) temperature is below 400 F. If the latch is not at a good lock position, the control will fault. If a latch fault occurs while the RTD is above the lock temperature, the latch will not try to move, but the fault is still logged to EEPROM after the first stage of detection. The Display column for latch faults applies 1) If the latch was moving when the fault occurred; 2) If the latch is already in a known locked state when the fault occurs. LOCK flashes after a fault is detected and until the unlocked position is achieved. The unlock position may be identified by a successful unlock switch closure, or as the result of timing when the unlock switch is not functioning properly. If the last known good position was unlock (e.g. baking, or idle) and a latch fault occurs, the motor is never moved. The fault is logged to EEPROM and is not seen by the user. The detection for latch faults is in two stages. The first stage is to let the control recover without moving the latch. Then: If the latch was previously at a known good unlock position, the latch will not move and the control will fault. If the control was previously in a known good lock position: If the RTD is below 400 F, the latch will attempt to recover to the proper position (up to three revolutions). If it cannot, the control will fault and the latch will move to a calculated unlock position. If the RTD is at or above 400 F, the control will fault. When the RTD cools to below 400 F, the control will attempt to recover to a good unlock position (up to three revolutions). If it cannot, the control faults and the latch moves to a calculated unlock position. NOTE: If the unlock position cannot be found, this may result in a second fault, the first fault occurring when the latch request was locked, and the second when the latch request is unlocked. If the latch is moving when the fault occurs, the control will bypass the first stage of detection and immediately try to find it s proper position. If it cannot, the control will fault and the latch will move to a calculated unlock position. Affected DLBs (Double Line Breaks) and loads are disabled during detection. If the control is in a known good unlock position and the lock switch becomes faulted: The control will not fault. If a function requiring latch movement is attempted while the lock switch is faulted, the control will sound an error tone and the function will be disabled. If the control is in a known good lock position and the unlock switch becomes faulted: The control will not fault. After the function is canceled and unlock attempted, the control attempts to unlock the latch according to the procedures in these notes. 16027229 8 June 2006 Replaces 16026900 2006 Maytag Services

Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Schematic (Control Circuits) MER5875RAS Series 11, MER5875RAF/B Series 12, MER5875RAN Series 13 June 2006 9 16027229 2006 Maytag Services Replaces 16026900

Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Wiring Diagram MER5875RAS Series 11, MER5875RAF/B Series 12, MER5875RAN Series 13 16027229 10 June 2006 Replaces 16026900 2006 Maytag Services

Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Schematic (Control Circuits,) MER5875RAS Series 12, MER5875RAF/B Series 13, MER5875RAN Series 14 June 2006 11 16027229 2006 Maytag Services Replaces 16026900

Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Wiring Diagram MER5875RAS Series 12, MER5875RAF/B Series 13, MER5875RAN Series 14 16027229 12 June 2006 Replaces 16026900 2006 Maytag Services

Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Schematic (Control Circuits) MER5875RAS Series 13, MER5875RAF/B Series 14, MER5875RAN Series 15 June 2006 13 16027229 2006 Maytag Services Replaces 16026900

Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless Wiring Diagram MER5875RAS Series 13, MER5875RAF/B Series 14, MER5875RAN Series 15 16027229 14 June 2006 Replaces 16026900 2006 Maytag Services