AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL

Similar documents
Clamp Earth Tester MET-2. Instruction Manual

DIGITAL CLAMP TESTER MODEL HCL-5000D

ROGOWSKI LEAK METER MODEL RLM-1

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

OPERATING INSTRUCTIONS

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

OPERATING INSTRUCTION

OPERATING INSTRUCTION

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

1.Safe testing IMPORTANT:

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Safety design conforming to the following provisions

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Safety design conforming to the following provisions

Digital Multimeter User's Manual

Ground Resistance Tester Model 3620 & 3620 Kits

EVS RP6020. Instruction Manual

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

DIGITAL MULTIMETER INSTRUCTION MANUAL

Dawson DDM190D. Digital Multimeter User s Manual

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

RP Instruction Manual

Table of Contents Title Page No.

362 Clamp Meter. Users Manual

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

OPERATING INSTRUCTIONS

HL (AZH) LIMIT SWITCHES

OPERATING INSTRUCTION

Portable Instruments. Bulletin 2000-E

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

DIGITAL RCD(ELCB) TESTER

362 Clamp Meter. Users Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

FX2N-2LC SPECIAL FUNCTION BLOCK

323/324/325 Clamp Meter

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

INSTRUCTION MANUAL DM5B Fax: (503)

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

Digital/Analog Megohmmeter Model 1026

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

SafetyPAT Plus A B P/N:

POWER REGULATOR LD -40PSU

HL (AZH) Limit Switches

MANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL

Advanced Test Equipment Rentals ATEC (2832)

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

EPS/ELA-Series User Manual EPS/ELA 250W

302+/303 Clamp Meter. Users Manual

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

7/05 FORM#347 OPERATING INSTRUCTIONS MULTI FUNCTION TESTER MODEL 6030

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Related vacuum products

User Guide. Model Insulation Tester / Megohmmeter

5.2 PRE-OPERATION PROCEDURE WARRANTY

OPERATING MANUAL CMP-200

INSTRUCTION MANUAL M110A Fax: (503)

WR 22SE WR 25SE WR25SE. Handling instructions

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Switching DC Power Supply

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

2-Color Display High-Precision Digital Pressure Switch

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Digital/Analog Megohmmeter Model 1026 USER MANUAL

USER MANUAL. Insulation Tester + DMM. Model MG320

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

LINE CONDITIONERS USER'S GUIDE

Filterpack FR-BFP2-(H)0.4K to (H)15K

MCA-700Ⅱ JAPAN BONKOTE CO.,LTD. Instruction manual. Preparation in April The 1st edition

User Guide. Model Insulation Tester / Megohmmeter

Dawson DAN100. Analog Multimeter User s Manual

365 Detachable Jaw True-rms Clamp Meter

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

ORIGINAL INSTRUCTIONS

COMPONENT-TESTER INSTRUCTION MANUAL

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Electrical Actuator HH-500 REsearch COntrol

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Transcription:

AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL Thank you very much for selecting our digital AC clamp-on tester. This model is complex instrument and employ a very reliable mechanical/electronic design. Before you use your new instrument, read this Instruction Manual completely and familiarize yourself thoroughly with all functions. With proper use and care, your tester will give you years of satisfactory service. MULTI MEASURING INSTRUMENTS CO.,LTD. Akihabara Murai Bldg. 7F, 1-26 Kanda Sakuma-cho, Chiyoda-ku, Tokyo, Japan, 101-0025 TEL : +81-3-3251-7016 FAX : +81-3-3253-4278 Home Page : http://www.mutimic.com/ E-mail : multi@multimic.com

1. FEATURES High accuracy analog display with strong taut band meter. Meter lock function and data output for recorder. 3 years long battery life. Filter circuit for high frequency noise rejection. 2.! WARNING Do not make measurements of power lines carrying more than 250V. IN SOME CASES, POWER LINES MAY CARRY VOLTAGE SPIKES OF SEVERAL TIMES OF THE NORMAL SUPPLY VOLTAGE. THIS INSTRUMENT SHOULD BE USED TO MEASSURE POWER LINES. *The terms of POWER LINE means the electrical circuit providing the power to factories, buildings, etc. Before operating this instrument, familiarize yourself with all instructions outlined in this manual. Always check to make sure that the function switch is set to the proper position. When making measurements, use CAUTION as dangerous voltages may be present in normally safe areas. To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC rms. Such voltages pose a shock hazard. Never make measurements with the case opened. Never fail to keep the maximum tolerable input. Never operate this instrument if it becomes wet, damp or has any liquid condensation build-up on any part of the instrument. Never make measurements for uninsulated conductors or bus bars.

3. SPECIFICATIONS Safety standard : Meets the requirements for double insulation to IEC61010-2-032, IEC61010-1, installation CategoryⅢ600V phase to earth. E.M.C. standard : The instrument meets EN61326 and EN61000. Withstanding voltage : AC 5500V, 1 minute (between outer case and core of CT) Jaw opening capability : 40mmφ Current : AC 10mA/50mA/500mA/1A/5A/50A/500A Accuracy :±3% of F.S.(50/60Hz) Voltage : AC 0~500V Accuracy :±3% of F.S.(50/60Hz) Resistance : 0~1KΩ(50Ω center) Accuracy :±3% of scale length Analog data output for recorder: DC 100mV for full scale Operating temperature : 0 to 40, <80%RH (non-condensing) Strange temperature : 10 to 60, <70%RH (non-condensing) Power supply : 1.5V ( AAA size, R03) x2 Size : 69(W)x210.5(H)x34(D)mm Weight : Approx. 403g Accessories : Carrying case..1 Instruction manual 1 Batteries 2 Test lead 1set 4. DIMENSIONS AND PANEL FUNCTION 1 Current transducer (Jaw) 2 Jaw opening lever 3 Range selector switch 4 Meter lock knob 5 Zero Ω adjustment knob 6 Pointer 7 Pointer zero adjustment screw 8 Input terminal (V) (Ω) 9 COM terminal 10 Terminal for recorder (REC) 11 Battery cover 12 Wrist strap 13 Filter Switch 14 Power/battery check switch 13 14

5. METHOD OF MEASUREMENT 5-1. Preparation and Caution before Measurement Before measurements, be sure the meter lock function is released. Set the range selector switch to ~ma or ~A range and set the power switch to BATT. If the pointer indicates within the BATT mark, the batteries are usable. If the pointer indicates outside the mark, the batteries are exhausted. In this case, replace the batteries with new ones. Set the Zero (0) position of the pointer. If the position is incorrect, adjust it by the pointer zero adjustment screw. 5-2. Reading Method of The Scale No. Function Range Multiplying factor 10mA 1 50mA 1 1 Current 500mA 10 1A 0.1 5A 0.1 50A 1 2 500A 1 3 Voltage ~500V 1 4 Resistance 1KΩ 1

5-3. Measurement of AC Line Current L 2 Set the range selector switch to a range appropriate to the current to be measured. Start the measurement at top range and then work down to lower range. 3 Clamp the conductor of the circuit at the center of CT. 4 Read the current value on the current scale. 5 If you make measurements in a dark place or in a place where it is difficult to see the readings, use the meter lock function. Fig.1 Note : Clamp around only one conductor of the circuit to be measured. (See Fig.1) 5-4. Measurement of AC Leakage Current 5-4-1. Leakage current measurement for the grounding line 2 Set the range selector switch to a range appropriate to the current to be measured. 3 Clamp the conductor of the circuit at the center of CT. 4 Read the current value of the current scale. 5 If you make measurements in a dark place or in a place where it is difficult to see the readings, use the meter lock function 5-4-2. Leakage current measurement for the single-phase or three phase circuit 2 Set the range selector switch to a range appropriate to the current to be measured. 3 To measure a leakage current in a single-phase electric circuit, clamp two conductors together. Or clamp the three conductors together in the case of the three-phase electric circuit. 4 Read the current value of the current scale. 5 If you make measurements in a dark place or in a place where it is difficult to see the readings, use the meter lock function! CAUTION To avoid electrical shock or damage, the measurement is limited to the circuit under 600V AC and 500A AC.

5-5. Measurement of AC Voltage 2 Connect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal. 3 Set the range selector switch to ~600V range. 4 Contact the tips of the test leads to the circuit under test. 5 Read the voltage on the scale. Fig.2 Fig. 2! WARNING Do not make measurements of power lines carrying more than 250V. IN SOME CASES, POWER LINES MAY CARRY VOLTAGE SPIKES OF SEVERAL TIMES OF THE NORMAL SUPPLY VOLTAGE. THIS INSTRUMENT SHOULD NOT BE USED TO MEASURE POWER LINES. * The term of Power Line mean the electrical circuit providing the power to factories, buildings, and etc.! WARNING POSSIBLE ELECTRICAL SHOCK. Do not make measurements if the case is damaged or the rear case is removed. Remove all electrical inputs before removing the rear case.! WARNING POSSIBLE ELECTRICAL SHOCK or FIRE HAZARD. Do not expose this tester to rain or moisture. Do not operate the tester in the presence of flammable gases or fumes.! CAUTION To avoid damage to the tester, disconnect test leads before changing functions. Do not exceed the maximum input limits.

5-6. Measurement of Resistance 2 Connect the plug of red test lead into the Ω terminal and the plug of black test lead into the COM terminal. 3 Set the range selector switch to Ω range. 4 Short the tips of test leads and adjust the pointer to indicate zero with the zeroω adjustment knob. 5 Contact the tips of the test leads to the circuit under test. 6 Read the resistance on theωscale. Fig.3! CAUTION Be sure all voltage is turned OFF in the circuit before making resistance measurement. 5-7. Measurement for External Recorder DC 100mV/full scale analog signal is available for the external recorder. REC and COM terminal can be used for the connection to the external recorder. The input resistance of the recorder to be used should be at least 1MΩ or more. Recorder Input impedance > 1MΩ

6. REPLACEMENT OF BATTERIES AND FUSE (BATTERY REPLACEMENT) 1) Remove the fixing screw of battery cover by + driver on rear case and slide the battery cover to the direction of arrow mark to open battery case. 2) Take out 3 exhausted batteries. 3) Install new batteries (UM-4 or type AAA), observing polarity. 4) Put back the battery cover to the original position and tighten the fixing screw firmly. (FUSE REPLACEMENT) 1) The fuse will be taken off when pressing 1 point from up to down by the sharp object (like thin tip of ballpoint). 2) Take out the spare fuse and insert it to 2 point. Press the metal part at 1 point from down to up by the sharp object. NOTE: It may cause breakage of the fuse glass part. Do not push the glass part by the sharp object at the time of replacement.! WARNING Before changing batteries or fuse, remove all electrical inputs. Do not replace the batteries under the conditions of clamping CT to the conductor and or inputting voltage to the terminals. * Do not use the mixed batteries of new & old ones and or different kinds. ΔCAUTION In case of not using the instrument for a long time, remove the batteries and storage. Leakage of batteries may cause damage of instrument. 7. MAINTENANCE When making requests for repair service, please bring the instrument directly to the dealer. If this is impossible, however, send the instrument directly to our sales office. When mailing this instrument, always pack it in its original or equivalent packing material and pack together with name, address, telephone number and the warranty documentation. To ensure speedy and reliable repair, always include information as the type of failure and cause. If required, always return accessories with the instrument. When contacting us, provide the model number and serial number of your instrument.