Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Similar documents
Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Checking the usage. Slow opening/slow closing damping unit:

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 12.

3 Edition Product brochure GB AGA

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Tightness control TC. Product brochure GB Edition 12.10

Solenoid actuator MB 7 and butterfly valves BVHM

Safety 0 50 Please read and keep in a safe place Operating instructions Solenoid valve for gas VAS 1, double solenoid valve VCS 1

Butterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS For gas, air, hot air and

Solenoid valves for gas VAS, Double solenoid valves VCS AGA

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Solenoid valves for gas VAS Double solenoid valves VCS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Safety. Operating instructions Protective system control FCU 500 Furnace zone control FCU 505 DANGER. Contents WARNING CAUTION

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 6213 EV, 6281 EV

Solenoid valves for gas VAS, Double solenoid valves VCS

Butterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Safety. Operating instructions Protective system control FCU 500 DANGER. Contents WARNING CAUTION. Changes to edition 08.12

Swing Piston Compressors and Vacuum Pumps

Solenoid valves for gas VAS, Double solenoid valves VCS

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Combination controls CG 10

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Angle seat valve with piston actuator VZXA-...-K

Old documentation - Only for your information! Product is not available any more!

HST-BL-2830MS & HST-BL-2830MS-USA

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)

Angle seat valve with diaphragm actuator VZXA-...-M

Oil-free piston compressors KK and piston vacuum pumps KV

Manually operated safety shut-off valve HSAV HSAV/5

SERIES 2000 GAS SAFETY SHUT OFF VALVE

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Declaration of Conformity as per Directive 97/23/EC

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Angle seat valve with piston actuator VZXA-...-K

Gas Pressure Governors

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

OPERATING INSTRUCTIONS

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

Solenoid Operator 0516 / 1216

DSV. Operating Manual. Double Seal Butterfly Valve. Read and understand this manual prior to operating or servicing this product.

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Installation manual portable distributors

Mounting and Operating Instructions EB 5868/5869 EN

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Ex m Solenoid Operator Type 0519

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

B21 Series BASOTROL Gas Valve

Installation manual wall-mounted distributor

Pneumatic grease pump 50:1 and grease supply system

Original Operating Manual CVP High-Pressure Centrifugal Pump

Installation and Operating Instructions Magnetic Vibrator MR 1

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Wilo-Control SC-Fire Jockey

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Proportional controlling element

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

MANUAL. Single charger

Pneumatic Axial Fan Type Tech. Doc. No. 802

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

A408 GB. Pneumatic oil and diesel pumps 1:1

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

BGD278 Series BASOTROL CE Approved Gas Valve

Instruction Manual. Sewage lifting station compli 300

Solenoid valves for gas VAS, Double solenoid valves VCS

Solenoid Operator 0513 / 1213

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

HST -LS Interlocking device (Translation of Original Manual)

Valve monitoring system VDK 200 A S02

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Transcription:

27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety.... Checking the usage...2 Intended use...2 Type code...2 Part designations...2 Type label....2 Installation...2 Wiring...3 Tightness test...3 Replacing the actuator...4-5....4 2-25....4 Maintenance...4-5....4 2-25....5 Assistance in the event of malfunction...6 Technical data...7 Designed lifetime... 7 Logistics...7 Certification...8 Declaration of conformity...8 Approval for Australia...8 Eurasian Customs Union...8 Contact...8 Safety Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator. This unit must be installed and commissioned in accordance with the regulations and standards in force. These instructions can also be found at www.docuthek.com. Explanation of symbols,,,... = Action = Instruction Liability We will not be held liable for damage resulting from non-observance of the instructions and non-compliant use. Safety instructions Information that is relevant for safety is indicated in the instructions as follows: DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. CAUTION Indicates possible material damage. All interventions may only be carried out by qualified gas technicians. Electrical interventions may only be carried out by qualified electricians. Conversion, spare parts All technical changes are prohibited. Only use OEM spare parts. Changes to edition 5. The following chapters have been changed: Installation Certification -

Checking the usage Intended use Gas solenoid valve for safeguarding gas or air on various appliances. This function is only guaranteed when used within the specified limits see page 7 (Technical data). Any other use is considered as non-compliant. Type code Code Description Gas solenoid valve 25 Nominal size R Rp internal thread p e max. 5 mbar 2 p e max. 2 mbar Q Mains voltage: 2 V AC, 5/6 Hz W Mains voltage: 23 V AC, 5/6 Hz 5 Connection via rectifier adapter without standard socket 6 Connection via rectifier adapter and standard socket Part designations 4 3 Installation CAUTION Please observe the following to ensure that the is not damaged during installation and operation: Do not clamp the unit in a vice. Only secure the flange by holding the octagon with a suitable spanner. Risk of external leakage. Continuous operation at high temperatures accelerates the ageing of elastomer materials. Do not install or store the unit in the open air. Dropping the device can cause permanent damage. In this event, replace the entire device and associated modules before use. Check max. ambient temperature see type label. Check max. inlet pressure see type label. Installation position: black solenoid actuator in the vertical upright position or tilted up to the horizontal, not upside down. 6 5 2 The housing must not be in contact with masonry. Minimum clearance 2 mm. > 2 mm Housing 2 Actuator 3 Quick fastener 4 Seals 5 Rectifier adapter 6 Socket Type label Rated voltage, electrical power consumption, installation position, max. inlet pressure p e max., ambient temperature, enclosure and medium: see type label. Sealing material and dirt, e.g. thread cuttings, must not be allowed to get into the valve housing. Install a filter upstream of every system. Use approved sealing material only. Use a suitable spanner. 2 3 D-498 Osnabrück, Germany 4-2

Wiring Tightness test WARNING Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power The solenoid actuator heats up during operation depending on ambient temperature and voltage. > +8 C CAUTION Please observe the following to ensure that the is not damaged during the tightness test: Check max. inlet pressure see type label. Test pressure.5 x max. inlet pressure. Close the solenoid valve. 2 To be able to check the tightness, shut off the downstream pipeline as close as possible to the valve. 3 The rectifier adapter must be installed. Use temperature-resistant cable (> 8 C). Disconnect the system from the electrical power 2 Shut off the gas Wiring to EN 624-. The actuator can be rotated. 3 4 5 N 2,5 x p e max 4 Open the solenoid valve. 5 6 7 8 = N 2 = L 2 3 N 2,5 x p e max 6 Tightness OK: the unit is ready for operation. 7 Open the pipeline again and release the gas leaking: dismantle the unit and return it to the manufacturer. 9 Plug insert can be rotated in 9 steps. 2-3

Replacing the actuator We recommend replacing the entire actuator set when replacing the actuator. Actuator set -5 comprises the actuator, x O ring, x seal and x quick fastener. Actuator set 2-25 comprises the actuator and 2 x O rings. The actuator set is available separately as a spare part. Disconnect the system from the electrical power 2 Shut off the gas 3 4 5-5 6 7 8 Do not remove the grounding spring A. 9 A 4 The unit is ready for operation. 5 Release the gas Maintenance In order to ensure smooth operation: check the tightness and function of the every year, or every six months if operated with biogas. Checking tightness and function In order to determine whether the is tight and closes securely, check the internal and external tightness, see page 3 (Tightness test). Check electrical installations in line with local regulations; pay particular attention to the PE wire, see page 3 (Wiring). We recommend replacing the entire seal set when servicing the solenoid valve. Seal set -5 comprises the valve seal, 2 x O-rings, x seal and x quick fastener. Seal set 2-25 comprises the valve seal and 3 x O-rings. The seal set is available separately as a spare part. Disconnect the system from the electrical power 2 Shut off the gas -5 3 4 5 A 2-25 6 7 8 Do not remove the grounding spring A. 6 7 8 9 Check closing spring for damage. Closing spring damaged: dismantle the unit and return it to the manufacturer. 9 2 3 4 2 3 4-4

5 6 7 7 8 9 2 2 22 23 CAUTION Please observe the following to ensure that the is not damaged during subsequent operation: Install the closing spring in the correct position. Ensure that the catch of the closing spring is positioned in the opening of the valve disc. 2-25 3 4 5 8 9 2 6 7 8 2 22 23 9 23a Check closing spring for damage. Closing spring damaged: dismantle the unit and return it to the manufacturer. 2 3 24 Close the solenoid valve. 25 To be able to check the tightness, shut off the downstream pipeline as close as possible to the valve. 26 4 5 6 N 2,5 x p e max 7-5

27 Tightness OK: the unit is ready for operation. 28 Open the pipeline again and release the gas! Guiding elements bent. Incorrect handling when installing the unit. Assistance in the event of malfunction WARNING Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power Fault-clearance must only be undertaken by authorized trained personnel. Unauthorized repairs or incorrect electrical connections can cause the solenoid valve to become defective. In this case, our warranty will be rendered void.? Fault! Cause Remedy Possible faults and suggested solutions? The solenoid valve does not open, there is no flow downstream of the solenoid valve.! There is no power Check wiring, see page 3 (Wiring).! Rectifier adapter defective. Remove socket and rectifier adapter, see page 4 (Replacing the actuator), steps to 5. Check the ohmic resistance of the rectifier adapter between contacts and 2. Note the inscription on the rectifier adapter. Dismantle the unit and return it to the manufacturer.? The solenoid valve does not close securely, the flow downstream of the solenoid valve does not stop.! Valve seat is dirty. Clean the valve seat, see page 4 (Maintenance). Install a filter upstream of the solenoid valve.! Valve seat is damaged. Dismantle the unit and return it to the manufacturer.! Valve seal is damaged or hardened. Replace the valve seal, see page 4 (Maintenance).! Guiding elements bent. Incorrect handling when installing the unit. 2 Dismantle the unit and return it to the manufacturer. No resistance, replace adapter. The rectifier adapter is available separately as a spare part.! Actuator defective. Remove socket and rectifier adapter, see page 4 (Replacing the actuator), steps to 5. Check the ohmic resistance of the actuator between contacts (N) and 2 (L). Read off the contact assignment from the rectifier adapter. 2 No resistance, change actuator, see page 4 (Replacing the actuator). The actuator set is available separately as a spare part. -6

Technical data Gas types: natural gas, town gas, LPG (gaseous), biogas (max.. %-by-vol. H 2 S) or clean air; other gases on request. The gas must be dry in all temperature conditions and must not contain condensate. Opening time:.5 s. Closing time: < s. Ambient temperature: -2 to +6 C. Long-term use in the upper ambient temperature range accelerates the ageing of the elastomer materials and reduces the service life (please contact manufacturer). Storage temperature: -2 to +4 C. Safety valve: Class A, Group 2 pursuant to EN 6. Mains voltage: 23 V AC, +/-5%, 5/6 Hz, 2 V AC, +/-5%, 5/6 Hz. Electrical connection: plug with socket to EN 753-83. Power consumption: 2/23 V AC Type [W] 26 5 26 2 35 25 35 Enclosure: IP 54. Duty cycle: %. Power factor of the solenoid coil: cos ϕ =. Solenoid coil insulation: class F insulating material. Switching frequency: any. Valve housing: aluminium, valve disc: Perbunan. Internal thread: Rp to ISO 7-. Designed lifetime This information on the designed lifetime is based on using the product in accordance with these operating instructions. Once the designed lifetime has been reached, safety-relevant products must be replaced. Designed lifetime (based on date of manufacture) in accordance with EN 6 for : Designed lifetime Type Switching cycles Time [years] to 5 2, 2 to 25 5, You can find further explanations in the applicable rules and regulations and on the afecor website (www.afecor.org). This procedure applies to heating systems. For thermoprocessing equipment, observe local regulations. Logistics Transport Protect the unit from external forces (blows, shocks, vibration). On receipt of the product, check that the delivery is complete, see page 2 (Part designations). Report any transport damage immediately. Storage Store the product in a dry and clean place. Storage temperature: see page 7 (Technical data). Storage time: 6 months in the original packaging before using for the first time. If stored for longer than this, the overall service life will be reduced by the corresponding amount of extra storage time. Packaging The packaging material is to be disposed of in accordance with local regulations. Disposal Components are to be disposed -7

Certification Approval for Australia Declaration of conformity We, the manufacturer, hereby declare that the product, marked with product ID No. CE 63BL554, complies with the requirements of the listed Directives and Standards. Directives: 29/42/EC GAD (valid until 2 April 28) 24/3/EU 24/35/EU Regulation: (EU) 26/426 GAR (valid from 2 April 28) The relevant product corresponds to the tested type sample. The production is subject to the surveillance procedure pursuant to Directive 29/42/EC Annex II paragraph 3 (valid until 2 April 28) and to Regulation (EU) 26/426 Annex III paragraph 3 (valid from 2 April 28). Elster GmbH AGA Australian Gas Association, Approval No.: 5567 www.aga.asn.au/product_directory Eurasian Customs Union The product meets the technical specifications of the Eurasian Customs Union. Scan of the Declaration of conformity (D, ) see www.docuthek.com Contact If you have any technical questions, please contact your local branch office/agent. The addresses are available on the Internet or from Elster GmbH. We reserve the right to make technical modifications in the interests of progress. -8 Elster GmbH Strotheweg, D-4954 Lotte (Büren) Tel. +49 54 24- Fax +49 54 24-37 hts.lotte@honeywell.com, www.kromschroeder.com