CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Similar documents
SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

DC REGULATED POWER SUPPLY

DC REGULATED POWER SUPPLY

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

DC POWER SUPPLY ALIMENTATION C.C.

Switching DC Power Supply

Model 1900, 1901, 1902 Switching DC Power Supply

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Model 1900, 1901, 1902 Switching DC Power Supply

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Triple Output High Resolution Power Supply. User Manual

Triple Output Power Supply

Model 1672, 1673 Triple Output Power Supply

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Model 1693, 1694 Switching DC Power Supply

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

SBC / 2140 / Stage Battery Charger User Manual

CX-SERIES ADVANCED BATTERY CHARGER

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

230VAC Power Inverter 400W Owner s Manual

3000 Series Operation Manual

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Power Inverter 400 MW Owner s Manual

Dawson DDM190D. Digital Multimeter User s Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Phoenix Inverter

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Video & Power Over Coax Kit

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

RATE CONTROLLED TORQUE WRENCH TESTER

RU BMS Power Supply and Battery Management System Owners Guide

LS200 Series Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

OPERATING INSTRUCTIONS

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

OPERATING INSTRUCTIONS

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

CX Series User s Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Phase Sequence Tester

MOTORTRONICS Solid State AC Motor Control

KEPCO Will Point You In The Right Direction!

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

BROMAN MODEL 210 CONTACT RESISTANCE TEST SET SERIES 5

WARRANTY INFORMATION...

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

PSU-S-12V/L-3A/9/FTA/PTC-TR-MC AWZ v.1.0

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

High Accuracy Series REGULATED DC POWER SUPPLY. User s Manual

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

5.2 PRE-OPERATION PROCEDURE WARRANTY

AC/DC Converter MBP250-2A13D13M

Uninterruptible Power System

OPERATING INSTRUCTIONS

DC POWER SUPPLY (Switching mode)

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

3 Phase Smart Controller

Owner s Manual Currency Counter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

FHC-1D user manual. Features

Boston Gear Ratiotrol DC Motor Speed Control

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

SCR Power Controllers

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

PROwatt 150 DC to AC Power Inverter. Owner s Guide

BRAVER UPS. (Uninterruptible Power System) User s Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

Transcription:

CIRCUIT-TEST Switching Mode Power Supply with Remote Sensing PSC-9800 0-16V 5A / 0-27V 3A / 0-36V 2.2A (80W) OPERATION MANUAL 1

2 PSC-9800 08R14

Contents Safety Precautions...page 4 Introduction... 5 Controls and Indicators... 6 Operations... 8 Stand Alone Operations... 8 Master and Slave Operation... 9 Remote Sensing Operations... 11 Trouble Shooting... 12 Specifications... 13 Warranty... 14 3

Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct use of the power supply. Read through the manual and pay special attention to the markings and labels of this unit and equipment to be connected. Pay special attention to these two types of notices used in this manual WARNING: Failure to observe this warning may cause injury to persons and damage to power supply or connected equipment. CAUTION: Failure to observe this warning may result in damage to equipment and improper functioning of the power supply. Warning 1. Do not use this power supply near water. 2. Do not operate or touch this power supply with wet hands. 3. Do not open the casing of the power supply when it is connected to AC mains. 4. Refer all servicing to qualified service personnel only. 5. Before replacing the AC fuse find out and clear up the cause first. 6. Replace the AC fuse with the same type and rating as the original fuse. Caution 1. Use a grounded 3 pin AC source. 2. This unit is for indoor use only. Do not block any ventilation of the unit. 3. Do not operate or place this unit in a humid, dusty, direct sunlight or near any heat source. 4. Before plugging into AC mains, check the rating label at the back of the unit. 5. This unit must be used within the specified rating; excessive continuous loading will damage the power supply. 6. The gauge size of input power cable must be at least 0.75mm2 and the total length of power cable must not exceed 3m. 7. Input Fuse Recommended: T 2A/250V (2A Time Delay) NOTE: To be serviced by qualified personnel only. Operation Environmental Condition 10-80% R.H. Altitude up to 2000m Installation Category: CAT 2 Pollution degree: 2 Mains supply voltage fluctuation up to ±10% of specified operating voltage. 4

Introduction PSC-9800 is a constant power Switch Mode Power Supply with three different sets of voltage and current range giving the versatility of having three power supplies in one. The modular design with additional output terminals at the rear panel and Master/Slave control allows easy connection of up to 5 units in parallel. The user pre-set upper voltage limit ensures protection to voltage sensitive load. Remote sensing and digital display gives precise voltage reading at the load. 5

Controls and Indicators Front Panel Controls and Indicators 1 ON/OFF Power Switch 2 Front Panel Output Terminals 3 Upper Voltage Limit Adjustment 4 Current Tuning Knob 5 Voltage Tuning Knob 6 UVL/VOLTAGE To set and view Upper Voltage Limit 7 REVIEW To review the set voltage & current limit for pre-set range 8 V I Push Buttons To select Voltage & Current range 9 Output ON/OFF button Front LED Panel 10 UVL Upper Voltage Limit Indicator 11 C.V. Constant Voltage Indicator 12 C.C. Constant Current Indicator 13 ALM Alarm indicates the output voltage is either over the set Upper Voltage Limit or the power supply is in over temperature protection 14 SLAVE Indicates power supply is in Slave Mode 15 4 Digit Ammeter 16 4 Digit Voltmeter 6

Back Panel Terminals & Switch 17 Master/Slave Switch Used in Master/Slave control parallel mode 18 In/Out Terminal Control terminals for use in the Master/Slave control parallel mode 19 RS+ and RS- Remote Sensing Terminal 20 O/P+ and O/P- Alternative Output Terminals 21 INPUT Power Socket NOTE - In normal operation, Master/Slave switch should be set to Master (default) 7

1. Stand Alone Operation Operations Check the power supply is set as Stand Alone operation mode with the Master & Slave switch (17) set to Master position. Switch ON the power supply without any load by pushing (1) and the LED display should light up. There should not be any reading on the Voltmeter and the Ammeter. Press the Output On-Off button (9) and its green LED will light up, the voltmeter should show the set output voltage. Take note of the pre-set range and its LED, turn the voltage knob and check the voltmeter reading at the same time. 2. Selection of Voltage and Current Range When using the Voltage and Current range setting (8), take note of the Voltmeter reading changing to zero voltage and LED of Output On-Off button (9) turning off. The output terminal is off automatically when the VI range is changed, this is to safeguard the connected load. 3. PREVIEW Button Press (7) to check the values of VI when output terminal is off. Press and holding this button will show the output voltage and current limiting values previously set at the selected range with the output terminal off. 4. Setting the Current Limiting Value You can set the current limiting value without connecting to the load or shorting the output terminals. Press and hold the PREVIEW button (7) and turn the current knob (5) to desired value. 5. UVL/VOLTAGE Button (6) and UVL LED (10) Press UVL/VOLTAGE button to see the default value of Upper Voltage Limit. The LED (10) also lights up during this operation. 8

6. Setting the Upper Voltage Limit UVL value Press button (6) and insert a small screw driver (less than 3mm diameter) into (3), slowly turn clockwise to increase and anti-clockwise to decrease the UVL value. The UVL is an added protection for voltage sensitive load, only one UVL value can be set for all three ranges. When the output voltage exceeds the set UVL, the output terminal will be off automatically and the ALM (13) LED will light up. 7. Master & Slave Operation 7.1 Introduction Two or more units of PSC-9800 can be connected in parallel to increase output current to the sum of connected power supplies. In this mode of operation, the designated Master power supply will control all the voltage and current setting of the Slave power supplies. 7.2 Preparing and connecting the Control Terminals (19) Make sure all the power supplies are set to the same UVL by (6) and the same VI Range by (8). Set the voltage and current limit of all the Slave units to maximum values. Switch off all power supplies before any connections. Set the switch (17) to Slave position of all the Slave power supplies. Connect the Master & Slave control circuit as shown in Fig 7.1 and Fig 7.2 7.3 Output terminal Connection and Operation You can either use the Output Terminals at the front (2) or at the back (20) to connect to the load as shown in Fig 7.3 depending on your application and requirement. NOTE: All power cables should be of the same thickness and length. Caution: Double check the maximum voltage and current setting of the Slave units. Switch on the Master unit first and set to desired voltage, then switch on the Slave units. 9

The Slave indicator LED (14) should light up in the Slave units as a confirmation of correct connections. All the output voltages and currents of the Slave units are now controlled by the Master Unit. NOTE: When the output current in the Master & Slave connection drops to zero, the output voltage will no longer be controlled by the Master unit. Make sure to keep a minimum current flowing that is at least several percent of the rated current at all times. This can be done by supplying a small removable load. Fig 7.1 Fig 7.2 Fig 7.3 10

8. Remote Sensing Operation When the output current is high or there is a long connection to load, there is a voltage drop across the connecting cable and the voltage at load point will be less than at the output terminal of the power supply. By making an extra connection from the remote sensing terminal (19) to the load point will make up for the load line voltage drop and make the voltage at the load point and output terminal the same. Caution: Do not reverse the polarity. NOTE: Make sure to disconnect the wiring to remote sensing first before disconnecting the main output connection. 11

Trouble Shooting PROBLEM INDICATIONS POSSIBLE CAUSES SUGGESTED SOLUTIONS Power supply not working No DC output power Panel display LED indicators not ON Voltmeter zero indication AC input power is not connected. AC input fuse blown Output On/Off button not ON Check AC power connection 1. Check output LED (9) is ON, push (9) to ON. ALM (13) Alarm LED ON UVL (10) protection triggered 2. Check UVL set voltage by pushing (6), reset UVL to applicable limit, see section 5 & 6 ALM (13) Alarm LED ON OTP protection triggered 3. Check vent holes are clear, if ambient temperature is too high. CC (12) LED ON Output short circuit 4. Check and undo short circuit of output connection. Voltage meter reading is inaccurate Actual output voltage is different from the meter readouts Voltmeter is not showing the output voltage. 1. Check the UVL LED indicator on Voltmeter, if it lights up then the voltmeter only shows the set UVL value. Push (6) to return to output voltage. Possible misalignment in voltmeter calibration 2. Contact local agent, recalibration may be required. Current meter reading is inaccurate In CV mode, the actual current measured is different from the Ammeter reading Possible misalignment in calibration Contact local agent, recalibration may be required The activated (auto-cross over) Current limiting value is different from the pre-set CC value All indicators and display are normal, only CC mode has the problem For stand-alone unit, Master & Slave Switch (17) in wrong position (Slave). Wrong setting or connection in Master & Slave or set-up procedure Check if the Master & Slave switch (17) is in correct position. Use stand-alone mode to check power supply separately without any connection to slave units. Follow the procedure in section 8 carefully and make sure there is only one Master unit. 12

Specifications Input AC Voltage Range 120VAC No Load Input Current at 120VAC 0.2A Full Load Input Current at 120VAC 1.2A AC Input Frequency 47-63Hz~ Full Load Input Power 144W Efficiency 70% Power Factor 0.9 Constant Voltage and Current Range Selection: 0-16V / 5A selection I 0-16.4V 0-5.1A 0-27V / 3A selection II 0-27.6V 0-3.1A 0-36V / 2.2A selection III 0-36.8V 0-2.3A Constant Voltage Characteristics: Load Regulation (0-100%) 20mV Line Regulation (±10%) 4mV Ripple & Noise (peak to peak) 30mV Constant Current Characteristics: Load Regulation (0-100%) 10mA Line Regulation (±10%) 10mA Meter Accuracy: Voltmeter Accuracy ±1% +2 counts Ammeter Accuracy ±1% +2 counts Protection Adjustable Upper Voltage Limit, Current Limiting Protection, Short Circuit, Overload, Over Temperature Protection Output Terminals Front and Back of housing Additional Function Remote Sensing Cooling Natural Convection Dimensions (WxHxD) 53 x 127 x 330mm / 2 x 5 x 13 in Weight 1.9 kg / 4.2 lb 13

Warranty Circuit-Test Electronics warrants to the original purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase. Any product which has been subjected to misuse or accidental damage is excluded from the warranty. Except as stated above, Circuit-Test Electronics makes no promises or warranties either expressed or implied including warranties of merchantability or the fitness for any particular purpose. 14

Notes: 15

CIRCUIT-TEST ELECTRONICS Division of R.P. Electronic Components Ltd. BURNABY, BC CANADA V5J 5M8 16