PRODUCT OF FIRE PUMPS SYSTEMS

Similar documents
PRODUCING TRUST IN FIRE AND SAFETY FIRE PUMP SYSTEMS A PRODUCT OF COMPLIANT.

FIRE PUMP SYSTEMS. FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Series 4600F. HSC Fire Pumps & Packaged Systems

Waterfall Pumps Manufacturing

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

FIRE PUMPS & PACKAGED

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

900 Series Split Case Fire Pump Systems

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

AURORA COMPACT FIRE PUMP SYSTEMS

F F F F F F. Foam Systems Deluge Systems Hydrant Systems Sprinkler Systems Hose Reel Systems Hose Rack Systems

SINCE Double Suction Split Case Fire Pump. Series 4800 & (New Generation) 001-cat f

Head - m. Flow - US gpm. Comments. Customer : Contact : Re Cotizacion Metro Linea 4 EDB Project : Quote No. :

Bristol: A History & Future.

F-Series Fire Fighting Pumps

A-C Fire Pump. Fitting and Accessories A-C 100A

FLHC SERIES DATA BOOKLET

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Centrifugal End Suction Fire Pumps

4500C Series Vortex Pumps

SUGGESTED SPECIFICATIONS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

SCE Heavy Duty, Single Stage, Overhung, API 610 Process Pump (OH2)

Contents. Identification

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

Typical Specifications for Horizontal Fire Pumps

Pump Acceptance Test Data

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

University of Houston Master Construction Specifications Insert Project Name

FIRE PROTECTION PUMPS. Table of Contents

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

Reliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Instructions for Installation, Operation, Care and Maintenance

Flow Range Horsepower Best Eff. Discharge Minimum Rotation➀ GPM Range GPM Connection Well Size 5LS " CCW " CCW

PROJ. NO SECTION HYDRONIC PUMPS

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

P40 Series Foam Concentrate Pump

Fire Pump Capabilities N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

PRESSURE LIMITING DRIVERS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

JOCKEY PUMP CONTROLLERS

September 22, 2016 To: All Contractors Re: Boiler Back-Up Fuel Tank System Renovation. Dear Sir:

Weights: Motor... Lb Pump... Lb Extra Column... Lb

One & Two Stage Turbine Type Pumps

Corbrasion resistant, high performance slurry pumps Designed for solids laden waste water to aggressive slurries

900 Series. 2000/2500 GPM High Head. Expanding our line to meet your needs. Model Latest Addition to the Aurora Fire Pump Line

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

Instructions for Installation, Operation, Care and Maintenance

FIRE PROTECTION PRODUCTS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Darley UHP-HV Diesel Specification 1

Elite. KSB Australia Pty Ltd. Centrifugal Pump

VSC /VSCS Pumps Technical Brochure

20EVP-A SERIES. Vertical In-Line Self-Priming Centrifugal Pumps for Petroleums and Solvents. Marlow Pumps. Marlow Pumps.

PATTERSON PUMP COMPANY

VERTICAL IN-LINE PUMP

Electric Submersible Pumps

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

Coro-Flo Sales Catalog

Commercial Pressure Booster Systems

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

Underground Tank Applications Installation Guide

1. Wiring Diagrams: Power, signal, and control wiring.

IDROCHEMICAL CENTRIFUGAL PUMPS FOR CHEMICAL SERVICE ACCORDING TO ISO 2858 STANDARDS

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

MICROPUMP MAG-DRIVE GEAR PUMPS

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

SECTION FACILITY FUEL OIL PIPING

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES

Pressure boosting Single pumps

Pride in Performance

Vertical Pumps for the Oil & Gas Industry

ECLIPSE TURBO BLOWERS SERIES SMJ

BA100K Diesel Driven Dewatering and Sewage Pump Max. 836 US GPM, Max. 73 ft. / 31 PSI

340 Series Double Suction Split Case Pumps

3K111-3K193 3K361-3K393. 3K Series - Single Stage Stainless Steel End-Suction Centrifugal Pumps RPM Models RPM Models FEATURES

Goulds High-Pressure Multi-Stage Pumps

Goulds Small Capacity Double Suction Pump

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

TYPE PC Propeller Condensate Pumps

Sleeve Valves Energy Dissipaters

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

Transcription:

PRODUCT OF FIRE PUMPS SYSTEMS

3 SFFECO FIRE PUMPS SYSTEMS MANUFACTURING The Fire Pumps undergo various processes in our modern well organized manufacturing and assembly line. Before delivering to our customers, each pump undergoes necessary inspection, tests and production control, during the Assembly process, for which all records are maintained. TESTING FACILITY SFFECO has established a fully equipped state of the art, UL/FM and NFPA 2 compliant Pump Testing facility with advance testing and calibration devices that enable to accurately inspect and test the operation of each Centrifugal Stationery Fire Pump to the required level of compliance standard. PERFORMANCE TESTS Each pump produced, undergoes performance testings as follows a) OPERATION TEST Performance curves are plotted showing the Efficiency, Brake-Horsepower (kw), and Total Head developed at shutoff, at rated capacity, at 5 percent of rated capacity, and at selected intermediate capacities between shutoff and maximum capacities exceeding 5% of rated capacity. b) HYDROSTATIC TEST Each pump is tested hydrostatically for not less than 5 minutes. The test pressure is to be upto 2 times the maximum working pressure of the pump, but in no case less than 25 psi (724 kpa) to ensure no rupture or leakage through the castings at the test pressure. c) IMPELLER BALANCING The impellers of each pump are dynamically balanced to the G6.3 balance quality grade in accordance with the requirements for pump impellers in the Standard for Mechanical Vibration Balance Quality

4 CENTRIFUGAL FIRE PUMPS END SUCTION 5/6 Hz % Model Dsg. Rated Capacity (GPM) SFP 5-2 EM 5 32 6-7 6-2 23 SFP 5-2 EH 5 32-2- 23 5 SFP 5-26 EM 5 32 5-4 5-3 2 23 SFP 5-26 EH 5 32 63-26 6-5 23 SFP -2 EH 5 32 x 23 SFP -26 EH 5 32 5-5 x 23 SFP -5 EH 65 5 4-6- 23 SFP -26 EM 65 4-4 x 2 23 SFP -42 EH 65 4 6-43 x 3 23 SFP -4 EH 65 4 62- x 23 SFP 5-26 EM 65 4 4 x 2 23 SFP 5-42 EH 65 4 7-5 x 3 23 5 SFP 5-26 EH 65 4 56- x 23 SFP 5-2 EH 65 5 2-6 4-23 SFP 2-2 EH 65 5 6- -4 23 2 SFP 2-65 EM 65 5-6 5-6 2 23 SFP 25-26 EM 65 3-4 -4 2 23 25 SFP 25-2 EH 65 3-4 5-5 23 SFP 3-26 EM 65-2 - 2 23 3 SFP 3-2 EH 65-3 2-3 23 SFP 4-26 EM -3-3 2 23 SFP 4-26 EH 65-24 4 SFP 4-32 EM 5-2 62-7 2 25 SFP 4- EH 5-5-5 235 SFP 45-26 EM -2 5-2 2 23 SFP 45-26 EH 62-7 24 45 Suction Flange Ø (MM) Size Discharge Flange Ø (MM) UL Listed Rated Net Pressure Range (PSI) FM Approved Rated Net Pressure Range (PSI) Approx Speed (RPM) Max Working Pressure (PSI) SFP 45-32 EM 54-5-5 2 25 SFP 45- EH 2 - -5 235 SFP 5-26 EM - 4-2 23 SFP 5-26 EH 5 6-5 24 SFP 5-32 EM 4-4 56-4 2 25 5 SFP 5- EH - -4 235 SFP 5- EM 5-3 3-2 225 SFP 5- EM 5 2-2 6-26 2 245 SFP 75-26 EM 5 2-7 -6 2 225 75 SFP 75-32 EM 5 2-27 7-24 2 245 UL LISTED & FM APPROVED PUMPS Compliance to NFPA 2 Design & Installation Requirements. applications. horizontal listed/approved example :

5 CENTRIFUGAL FIRE PUMPS HORIZONTAL SPLIT CASE 5/6 Hz Horizontally Split Casing Design Efficiently Designed Shaft % Removable stuffing box Model Dsg. Rated Capacity (GPM) SFP 3-35 SM 5 2-222 2 3 3 SFP 3-35 SM 5-237 3 3 SFP 4-35 SM 5-2 2 3 SFP 4-35 SM 5-234 3 3 4 SFP 4-2 SM 5-55 2 23 SFP 4-2 SM 5 5-66 3 23 SFP 45-2 SM 5 6-55 2 23 45 SFP 45-2 SM 5 4-66 3 23 SFP 5-37 SM 5 4-233 2 2 SFP 5-3 SM 5 7-23 2 22 SFP 5-2 SM 5 4-54 2 23 SFP 5-2 SM 5 2-65 3 23 5 SFP 5-25 SH 5 3-65 253 SFP 5-25 SH 5-74 36 253 SFP 5-32 SM 5-2 2 SFP 5-32 SM 5-2 3 2 SFP 75-3 SM 5-2 2 22 SFP 75-25 SH 5 6-62 253 SFP 75-25 SH 5 3-7 36 253 75 Suction Flange Ø (MM) Size Discharge Flange Ø (MM) UL /FM Rated Net Pressure Range (PSI) Approx Speed (RPM) Max Working Pressure (PSI) SFP 75-32 SM 5-4 2 2 SFP 75-32 SM 5-2 3 2 SFP 75-2 SM 2 5 4-2 26 SFP 75-2 SM 2 5 5-6 3 26 SFP -3 SM 5 4-5 2 22 SFP-2 SM 2 5 43-2 26 SFP -2 SM 2 5 54-4 3 26 SFP -3 SM 2 5-43 2 23 SFP -3 SM 2 5 6-53 3 23 SFP 5-2 SM 2 5 7-77 2 26 SFP 5-2 SM 2 5 4-3 26 5 SFP 5-3 SM 2 5 4-4 2 23 SFP 5-3 SM 2 5-52 3 23 SFP 5-3 SM 2 5-5 2 23 5 SFP 5-3 SM 2 5 5-46 3 23 applications. 7 UL LISTED & FM APPROVED PUMPS Compliance to NFPA 2 Design & Installation Requirements. NEW APPROVALS OLD APPROVALS FM Approvals are under progress horizontal listed/approved example :

6 SFFECO FIRE PUMP SYSTEMS END SUCTION COMPLIANT BARE SHAFT PUMPS MOTOR DRIVEN DETAILS DIESEL DRIVEN DETAILS JOCKEY PUMP Flow (GPM) Model Dsg. APPROX SPEED (RPM) Head Bar (PSI) UL Listing Head Bar (PSI) FM APPROVED POWER RANGE (HP) POWER RANGE (HP) Motor Rating (HP) 4.6 (6) 4.6 (6) SFP 5-2 EM 2 5 5 5-2 5-2 6 (7) 6.7 () GPM 5 GPM 3 GPM 25 GPM 2 GPM 5 GPM SFP 5-2 EH SFP 5-26 EM 2 SFP 5-26 EH SFP -26 EH SFP -5 EH SFP -26 EM SFP -4 EH SFP 5-42 EH SFP 5-26 EH SFP 5-2 EH 2 SFP -42 EH 3 3 SFP 2-2 EH SFP 2-65 EM 2 SFP 25-26 EM SFP 25-2 EH 2 SFP 3-26 EM 2 SFP 3-2 EH 6.7 () 7.3 (2) 7.3 (2) 7.5 7.5. (). () 7.3 (5) 7.3 (5).7 (3).7 (3).66 (4).24 (63).5 (6).5 (6).45 (5).45 (5) 4.2 (26).7 (5).45 (5) 7.7 (4) 7.3(6) 7.3(6).3 ().3 ().6 () 7.52 ().24 (4) (6).6 (43).7 (62).66 6 () 7.3 (7).3 (5).76 (56).7 () 7.3 (2) 7.7 (4) 7.7 (4) 7.5 7.5.6 (6).6 (6). () 6.62 (6) 6.76 () 6.76 () 7 7.2 ().2 ().55 5 (4) 7.3 (5) 7.3 (5).3 (6).3 (6) 7.72() 72 7.7 (3) 7.7 (3).24 (4).24 (4) 7. (3) 7.24(5) 7.24(5).55 (4).55 (4).62 (5) 7.45 () 7.5 () 7.5 ().7 ().7 (). (2) 6.7 () 7.3 (2) 7.3 (2) 7.5 7.5.4 (3).4 (3) 5-2 5-2 2-3 3-4 2-25 2-25 25 2-25 4-5 25-3 5-6 25-3 25-4 3-4 4-5 4-5 4-5 4-5 NOT POSSIBLE WITH DIESEL EL ENGINE R 5-2 NOT POSSIBLE WITH DIESEL ENGINE RA NOT POSSIBLE WITH DIESEL ENGINE NOT POSSIBLE WITH DIESEL ENGINE RAN 2-3 NOT POSSIBLE WITH DIESEL ENGINE E 2-3 NOT POSSIBLE WITH DIESEL ENGINE NE NOT POSSIBLE WITH DIESEL ENGINE R NOT POSSIBLE WITH DIESEL ENGINE 3-57 3-57 NOT POSSIBLE WITH DIESEL EL ENGINE R 3-57 NOT POSSIBLE WITH DIESEL ENGINE NOTES TORNATEC CONTROLLERS ELECTRIC MOTOR - GPx Series (Alternatively GPL for 3 HP and below) DIESEL ENGINE - GPD JOCKEY PUMP - JP3

7 SFFECO FIRE PUMP SYSTEMS END SUCTION COMPLIANT BARE SHAFT PUMPS MOTOR DRIVEN DETAILS DIESEL DRIVEN DETAILS JOCKEY PUMP Flow (GPM) Model Dsg. APPROX SPEED (RPM) Head Bar (PSI) UL Listing Head Bar (PSI) FM APPROVED POWER RANGE (HP) POWER RANGE (HP) Motor Rating (HP) 75 GPM 5 GPM 45 GPM 4 GPM SFP 4-26 EM 2 SFP 4-32 EM SFP 5- EH 2 SFP 4- EH SFP 45-26 EM 2 SFP 45-32 EM 2 SFP 45- EH SFP 5-26 EM 2 SFP 5-32 EM SFP 5- EM SFP 5- EM 2 SFP 75-32 EM 2 2 SFP 75-26 EM 2 2 NOTES TORNATEC CONTROLLERS ELECTRIC MOTOR - GPx Series (Alternatively GPL for 3 HP and below) DIESEL ENGINE - GPD JOCKEY PUMP - JP3 7.45 () 7.5 () 7.5 ().5.5.7 (3).7(3). (5).7 (62).7 (62).5 (7).5 (7).7 (2) 7.24 (5) 7.3 (5) 7.3 (5) 5-75 -5 7-5- NOT POSSIBLE WITH DIESEL ENGINE.3 ().3 ().45 (5) 7.24 (5) 7.52 () 7.52 6-75 57-7.5.5. (2). (2).62 (54).6 (5).6 (5) -5 -..44(5).44(..44(5) 4.66 () 7.3 (2) 7.65 () 7.65 () 6-5 NOT POSSIBLE WITH DIESEL EL ENGINE E. ()..45(5) 7.7(4) 7( 7.45() 7.45() 6-75 57-7.3() 3) () 6.3 () 7.5() 7.5() 6-5 NOT POSSIBLE WITH DIESEL ENGINE E.7 ().7 ().3(4) 3(.2 (4).76(56).76(56) 56 6) -5 7-.3 (4).3(4) 7.66 () 7.7 (3) 7.7 7 (3) 75-7-.7 (3).5() (.4 (2).6(6).6(6) 75-5 - 4.4 (2) 4.4 (2) 4. (26) 7.3 (2) 7.45() 7.45() -5 7-.76 (7).76 (7).3 (6).7 (7).4 (2).4-2 -2 4.2 (27) 4.27 4.76(24) 57-7 3.- 3.-

SFFECO FIRE PUMP SYSTEMS SPLIT CASE MOTOR DRIVEN DETAILS MOTOR DRIVEN DETAILS DIESEL DRIVEN DETAILS JOCKEY PUMP Flow (GPM) Model Dsg. APPROX SPEED (RPM) HEAD Bar- (PSI) UL LISTING HEAD Bar- (PSI) FM APPROVED POWER RANGE (HP) POWER RANGE (HP) POWER RANGE (HP) 3 GPM 4 GPM 45 GPM.4 (2).4 (2) 2 6-5 57-4 4 5.3 (222) 5.3 (222) SFP 3-35 SM.3 ().3 () 3 6-5 7-4 4 5 5 6.34 (237) 6.34 (237) 6.76 6 () 6.76 () 7 7 SFP 4-2 SM 2 5-57-.6 (55).6 (55) 7.24 (5) 7.24 (5) SFP 4-2 SM 3 5-57-.45 (66).45 (66) 6).27 ().27 () SFP 4-35 -35 SM 2 6-5 7-4 4 5. (2) 5. (2). (). () SFP 4-35 SM 3 75-5 7-6 4 4 5 5 6. (234) 6. (234) 6.62 (6) 6.62 (6) 7 7 SFP 45-2 SM 2 5-57-.6 (55).6 (55) 7.7 (4) 7.7 (4) SFP 45-2 SM 3 6-57-.45 (66).45 (66) 6.4 (4) 6.4 (4) 7 7 SFP 5-2 SM 2 6-57-.62 (54).62 (54) 2--5.5 2--5.5 2-7.5 2-7.5 2--5.5 2--5.5 2--5.5 NOTES TORNATEC CONTROLLERS ELECTRIC MOTOR - GPx Series (Alternatively GPL for 3 HP and below) DIESEL ENGINE - GPD JOCKEY PUMP - JP3 FM Approvals are under progress

SFFECO FIRE PUMP SYSTEMS SPLIT CASE MOTOR DRIVEN DETAILS MOTOR DRIVEN DETAILS DIESEL DRIVEN DETAILS JOCKEY PUMP Flow (GPM) 5 GPM 75 GPM Model Dsg. APPROX SPEED (RPM) HEAD Bar- (PSI) HEAD Bar- (PSI) UL LISTING FM APPROVED POWER RANGE (HP) POWER RANGE (HP) POWER RANGE (HP) 7.3 (2) 7.3 (2) SFP 5-2 SM 3 6-57- 2--5.5.3 (65).3 (65).45 (7).45 (7) SFP 5-3 SM 2-5 -6 4 (23) 4 (23).2 ().2 () ) SFP 5-32 SM 2 75-5 7-6 6 2-7.5.65 ().65 ().3 ().3 () SFP 5-32 SM 3-2 -6 6 2-7.5 4 4 4.62 (2) 4.62 (2).24 (4).24 (4) SFP 5-37 -37 SM 2-5 -6 2-7.5 4 4 5 5 6.6 6 (233) 6.6 6 (233) 7.7 7 (3) 7.77 (3) SFP 5-25 SH 75-5.3 (65).3. (65).27 ().27 () SFP 5-25 SH 36 75-5 (74) (74) 7.65 () 7.65 () SFP 75-32 SM 2-2 -2-6 3--.3 (4).3 3 (4).27 ().27 () SFP 75-32 SM 3-2 -66 3-- 4.34 (2) 4.34 (2).3 ().3 () SFP 75-3 SM 2 5-2 -6 3--.6 (2).6 (2).2 (4).2 (4) SFP 75-2 SM 2 5-2 -6 2--.55 ().55 () NOTES TORNATEC CONTROLLERS ELECTRIC MOTOR - GPx Series (Alternatively GPL for 3 HP and below) DIESEL ENGINE - GPD JOCKEY PUMP - JP3 FM Approvals are under progress NOT POSSIBLE WITH DIESEL EL ENGINE E RA EN

SFFECO FIRE PUMP SYSTEMS SPLIT CASE MOTOR DRIVEN DETAILS MOTOR DRIVEN DETAILS DIESEL DRIVEN DETAILS JOCKEY PUMP Flow (GPM) Model Dsg. APPROX SPEED (RPM) HEAD Bar- (PSI) UL LISTING HEAD Bar- (PSI) FM APPROVED POWER RANGE (HP) POWER RANGE (HP) POWER RANGE (HP) GPM 5 GPM 5 GPM.6 (5).6 (5) SFP 75-2 SM 3 5-2 -6.5 (6).5 (6) 7.3 (6) 7.3 (6) SFP 75-25 SH 75-5.7 (62).7 (62) 7.7 (3) 7.7 (3) SFP 75-25 SH 36-5.7 (7).7 (7) 6.76 () 6.76 () 7 7 SFP -3 SM 2 5-2 -6 -.6 (43).6 (43) 7.3 (6) 7.3 (6) SFP -3 SM 3 5-2 -2.55 (53).55 (53).24 (4).24 (4) SFP -3 SM 2 5-2 -2.44 (5).44 (5).6 (43).6 (43) SFP -2-2 SM 2 5-2 6-2.4 ().4 ().62 (54).62 (54) SFP -2 SM 3 5-2 6-2.3 (4).3 3 (4) 6.4 (4) 6.4 (4) 7 7 SFP 5-3 SM 2 5-2 -6.72 (4).72 (4) 6.6 () 6.66 () SFP 5-3 SM 3 5-2 -2 2.4 (52).4 (52).45 (7).45 (7) SFP 5-2 SM 2 2-2525 6-25.2 (77).22 (77).2 (4).2 (4) SFP 5-2 SM 3 2-25 6-25.7 ().7 () 6.7 () 6.7 () SFP 5-3 SM 2 7 7 5-2 -2.3 (5).3 (5) 6.55 (5) 6.55 (5) 7 7 SFP 5-3 SM 3 5-25 -25.7 (46).7 (46) NOTES TORNATEC CONTROLLERS ELECTRIC MOTOR - GPx Series (Alternatively GPL for 3 HP and below) DIESEL ENGINE - GPD JOCKEY PUMP - JP3 FM Approvals are under progress NOT POSSIBLE WITH DIESEL ENGINE R 3-- 4-7.5 4-7.5 3-5.55 3-5.5 3-- 3-- 3-- 4-5.5 4-5.55 5.5-5.5-5.5-5.5-

FIRE PUMP SYSTEM COMPONENTS Jockey pumps are small, motor driven pumps used in conjunction with main fire pumps to compensate for minor leaks in the fire protection system and automatically maintain stand-by pressure. This reduces wear on the main pump and controller caused by unnecessary, frequent operation. Jockey Pump controllers are available for across the-line starting. DIESEL TANKS All Sffeco Steel Aboveground Tanks for flammable and combustible Liquid are assembled and tested to all requirements as follows * ANSI/UL-42 Compliant. * Installation standard compliance to NFPA 3, NFPA 3A and NFPA 3 PRIMARY CONTAINMENT TANKS. Horizontal Cylindrical Construction (Capacity Upto 75 Gallon) 2. Vertical Cylindrical Construction (Capacity Upto 6 Gallon) 3. Rectangular Construction (Capacity Upto 55 Gallon) SECONDARY CONTAINMENT TANKS. Horizontal Cylindrical Construction (Capacity Upto 75 Gallon) 2. Vertical Cylindrical Construction (Capacity Upto 6 Gallon) NOTE : UL LISTED TANKS ARE AVAILABLE UP ON CLIENT REQUEST. All Fire Pump Controllers are factory assembled, wired, tested as a unit and confirmed to all requirements of the latest edition of NFPA-2 (Centrifugal Fire Pumps) and NFPA-7 (National Electrical Code). Controllers are listed by Underwriters Laboratories, Inc., in accordance with UL2, Standard for Fire Pump Controllers, CSA, and Standard for Industrial Control Equipment (CUL) and approved by Factory Mutual (FM). All controllers are Y2K compliant. This component plays a vital role in fire pumps as it controls the entire system. It is selected as per customer choice if any, otherwise it can be either TORNATECH, FIRETROL, HUBBLE LEXINGTON OR JOSLYN CLARKE.

FIRE PUMP SKIDS SFFECO is an established well reputed manufacturer of Premium Custom Engine Driven Centrifugal Fire Pump Skids. We specialized in designing and developing packages in compliance to NFPA 2 requirements with Listed & Approved Drivers. SFFECO offers listed Centrifugal Fire Pump Skids that meet every fire protection need. Driven by Listed & Approved Diesel Engines or Electric Motors. Well aligned and Coupled for Direct Operation. Skid Packages are Pre-Tested and Inspected thoroughly before release to customers. One piece base plate with Anchor Bolt holes. Engineered, coated, hot rolled mild steel to resist corrosion and abrasion. Heavy Fabricated C-Channel Structure constructed to provide proper alignment of Pump with Diesel Engine or Pump with Motor. Compact skid Design with Small Foot-Print for Retrofit. High standard of Quality in material Construction finish and Workmanship. DIESEL DRIVEN SKIDS SFFECO maintains its standard with using it s proudly own listed & approved Black Stallion Diesel Engines and Centrifugal Fire Pumps to package Heavy Duty and High Quality Compact Skids. Our Listed and Approved Fire Pumps can also be coupled with any other Listed Diesel Engine of any specific brand as per customers requirement. SFFECO Diesel Driven Centrifugal Fire Pump Skids are available in combinations of both Listed and Approved Centrifugal End Suction Pumps and Centrifugal Horizontal Split Case Pumps coupled with Listed Diesel Engine Drivers MOTOR DRIVEN SKIDS SFFECO maintains its standard with using WEG which is High Efficiency Fire Pump Motors with our own Listed and Approved Centrifugal Fire Pumps to package Heavy Duty and High Quality Compact Skids. Our Listed and Approved Fire Pumps can also be coupled with any other Listed Fire Pump Motors of any specific brand as per client requirement. Suction Pumps and Horizontal Split Case Pumps coupled with Listed Fire Pumps Motors. SFFECO Motor Driven Centrifugal Fire Pump Skids are available in combinations of both Listed and Approved End

ACCESSORIES AND headers to system to waste JOCKEY CONTROLLER DIESEL CONTROLLER ELECTRIC CONTROLLER JOCKEY PUMP ARRANGEMENT 3 HORIZONTAL SPLIT CASE WITH AUTOMATIC AIR RELEASE VALVE HORIZONTAL SPLIT CASE WITH AUTOMATIC AIR RELEASE VALVE LEGEND OF ACCESSORIES ECCENTRIC REDUCER CONCENTRIC REDUCER The Arrangement Drawing Shown Above is for Visual and Information Purposes only. For detailed information regarding accessories please contact SFFECO Technical Team. All Accessories used should be UL Listed/FM Approved as per NFPA 2. GATE VALVE OS&Y CHECK VALVE FLEXIBLE JOINT ELBOW TEE - COMPOUND PRESSURE GAUGE 3 DISCHARGE PRESSURE GAUGE CASING RELIEF VALVE FLOW METER DRIP BALL VALVE BUTTERFLY VALVE GATE VALVE OS&Y CAN BE USED OPTIONAL GATE VALVE WASTE CONE MAIN RELIEF VALVE HOSE VALVE ELECTRIC CONNECTION RAW WATER COOLANT LINE PIPES SENSING LINE 3 - - water source ABOVE GROUND MOTOR DRIVEN SKID ARRANGEMENT DIESEL DRIVEN SKID ARRANGEMENT VORTEX PLATE

PRODUCT OF